The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Dissolving Microneedle Patch for Transdermal Delivery of Human Growth Hormone
Open accessAbstract
The clinical impact of biotechnology has been constrained by the limitations of traditional hypodermic injection of biopharmaceuticals. Microneedle patches have been proposed as a minimally invasive alternative. In this study, the translation of a dissolving microneedle patch designed for simple, painless self‐administration of biopharmacetucials that generates no sharp biohazardous waste is assessed. To study the pharmacokinetics and safety of this approach, human growth hormone (hGH) was encapsulated in 600 μm‐long dissolving microneedles composed of carboxymethylcellulose and trehalose using an aqueous, moderate‐temperature process that maintained complete hGH activity after encapsulation and retained most activity after storage for up to 15 months at room temperature and humidity. After manual insertion into the skin of hairless rats, hGH pharmacokinetics were similar to conventional subcutaneous injection. After patch removal, the microneedles had almost completely dissolved, leaving behind only blunt stubs. The dissolving microneedle patch was well tolerated, causing only slight, transient erythema. This study suggests that a dissolving microneedle patch can deliver hGH and other biopharmaceuticals in a manner suitable for self‐administration without sharp biohazardous waste.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prausnitz, M. R., & Langer, R. (2008) · Nature Biotechnology · doi:10.1038/nbt.1504 · Cited by 3,517
Self-citationMicroneedles for transdermal drug delivery
Prausnitz, M. R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.10.023 · Cited by 1,521
Self-citationNovel mechanisms and devices to enable successful transdermal drug delivery
Barry, B. W. (2001) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(01)00167-1 · Cited by 1,240
Biodegradable polymer microneedles: Fabrication, mechanics and transdermal drug delivery
Park, J.-H., Allen, M. G., & Prausnitz, M. R. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.02.002 · Cited by 1,026
Self-citationDissolving microneedles for transdermal drug delivery
Lee, J. W., Park, J.-H., & Prausnitz, M. R. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.048 · Cited by 968
Self-citationMcAllister, D. V., Wang, P. M., Davis, S. P., Park, J.-H., Canatella, P. J., Allen, M. G., & Prausnitz, M. R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2331316100 · Cited by 859
Self-citationEffect of Microneedle Design on Pain in Human Volunteers
Gill, H. S., Denson, D. D., Burris, B. A., & Prausnitz, M. R. (2008) · The Clinical Journal of Pain · doi:10.1097/ajp.0b013e31816778f9 · Cited by 701
Self-citationTANAKA, T., SHIU, R. P. C., GOUT, P. W., BEER, C. T., NOBLE, R. L., & FRIESEN, H. G. (1980) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-51-5-1058 · Cited by 571
The global burden of disease attributable to contaminated injections given in health care settings
Hauri, A. M., Armstrong, G. L., & Hutin, Y. J. F. (2004) · International Journal of STD & AIDS · doi:10.1258/095646204322637182 · Cited by 458
Minimally Invasive Protein Delivery with Rapidly Dissolving Polymer Microneedles
Sullivan, S. P., Murthy, N., & Prausnitz, M. R. (2008) · Advanced Materials · doi:10.1002/adma.200701205 · Cited by 391
Self-citationMatriano, J. A., Cormier, M., Johnson, J., Young, W. A., Buttery, M., Nyam, K., & Daddona, P. E. (2002) · Pharmaceutical Research · doi:10.1023/a:1013607400040 · Cited by 373
Biopharmaceutical benchmarks 2006
Walsh, G. (2006) · Nature Biotechnology · doi:10.1038/nbt0706-769 · Cited by 359
Clinical administration of microneedles: skin puncture, pain and sensation
Haq, M. I., Smith, E., John, D. N., Kalavala, M., Edwards, C., Anstey, A., Morrissey, A., & Birchall, J. C. (2009) · Biomedical Microdevices · doi:10.1007/s10544-008-9208-1 · Cited by 329
Prolactin-stimulated growth of cell cultures established from malignant Nb rat lymphomas.
Gout, P. W., Beer, C. T., & NOBLE, R. L. (1980) · PubMed · Cited by 281
The Effects of Formulation Variables on the Stability of Freeze-Dried Human Growth Hormone
Pikal, M. J., Dellerman, K. M., Roy, M. L., & Riggin, R. M. (1991) · Pharmaceutical Research · doi:10.1023/a:1015834724528 · Cited by 277
Sugar Micro Needles as Transdermic Drug Delivery System
Miyano, T., Tobinaga, Y., Kanno, T., Matsuzaki, Y., Takeda, H., Wakui, M., & Hanada, K. (2005) · Biomedical Microdevices · doi:10.1007/s10544-005-3024-7 · Cited by 256
Kim, Y.-C., Quan, F.-S., Compans, R. W., Kang, S.-M., & Prausnitz, M. R. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.10.013 · Cited by 255
Self-citationTransdermal protein delivery by a coadministered peptide identified via phage display
Chen, Y., Shen, Y., Guo, X., Zhang, C., Yang, W., Ma, M., Liu, S., Zhang, M., & Wen, L.-P. (2006) · Nature Biotechnology · doi:10.1038/nbt1193 · Cited by 249
Verbaan, F. J., Bal, S. M., van den Berg, D. J., Groenink, W. H. H., Verpoorten, H., Lüttge, R., & Bouwstra, J. A. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.11.009 · Cited by 227
FDA Drug Approval Summary: Bevacizumab Plus FOLFOX4 as Second-Line Treatment of Colorectal Cancer
Cohen, M. H., Gootenberg, J., Keegan, P., & Pazdur, R. (2007) · The Oncologist · doi:10.1634/theoncologist.12-3-356 · Cited by 217
Transdermal Influenza Immunization with Vaccine-Coated Microneedle Arrays
Koutsonanos, D. G., Martin, M. D. P., Zarnitsyn, V. G., Sullivan, S. P., Compans, R. W., Prausnitz, M. R., & Skountzou, I. (2009) · PLoS ONE · doi:10.1371/journal.pone.0004773 · Cited by 198
Self-citationFear of needles and vasovagal reactions among phlebotomy patients
Deacon, B., & Abramowitz, J. (2006) · Journal of Anxiety Disorders · doi:10.1016/j.janxdis.2006.01.004 · Cited by 196
Park, J.-H., Yoon, Y.-K., Choi, S.-O., Prausnitz, M. R., & Allen, M. G. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889173 · Cited by 172
Self-citationBiopharmaceuticals: recent approvals and likely directions
Walsh, G. (2005) · Trends in biotechnology · doi:10.1016/j.tibtech.2005.07.005 · Cited by 152
Self-dissolving microneedles for the percutaneous absorption of EPO in mice
Ιtο, Y., Yoshimitsu, J., Shiroyama, K., Sugioka, N., & Takada, K. (2006) · Journal of drug targeting · doi:10.1080/10611860600785080 · Cited by 142
Barry, B. W., & Woodford, R. (1974) · British Journal of Dermatology · doi:10.1111/j.1365-2133.1974.tb12903.x · Cited by 100
Compliance with growth hormone treatment--are they getting it?
Smith, S. L., Hindmarsh, P. C., & Brook, C. G. D. (1993) · Archives of Disease in Childhood · doi:10.1136/adc.68.1.91 · Cited by 97
Leitner, V. M., Guggi, D., Krauland, A. H., & Bernkop‐Schnürch, A. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.08.001 · Cited by 84
Reducing injection pain in children and adolescents with diabetes: a review of indwelling catheters
Hanås, R. (2004) · Pediatric Diabetes · doi:10.1111/j.1399-543x.2004.00048.x · Cited by 45
Delivery Technologies for Biopharmaceuticals: Peptides, Proteins, Nucleic Acids and Vaccines
(2009) · Wiley eBooks · doi:10.1002/9780470688397 · Cited by 35
Growth Hormone Therapy for Short Children Born Small for Gestational Age
Chatelain, P., Carrascosa, A., Bona, G., Longás, Á. F., & Sippell, W. G. (2007) · Hormone Research in Paediatrics · doi:10.1159/000107935 · Cited by 32
Twenty Years of Recombinant Human Growth Hormone in Children: Relevance to Pediatric Care Providers
Hardin, D. S., Kemp, S. F., & Allen, D. B. (2007) · Clinical Pediatrics · doi:10.1177/0009922806293924 · Cited by 29
Cited by
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
Self-citationLarrañeta, E., Lutton, R. E. M., Woolfson, A. D., & Donnelly, R. F. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.03.001 · Cited by 964
Aldawood, F. K., Andar, A., & Desai, S. (2021) · Polymers · doi:10.3390/polym13162815 · Cited by 499
Chang, H., Zheng, M., Yu, X., Than, A., Seeni, R. Z., Kang, R., Tian, J., Khanh, D. P., Liu, L., Chen, P., et al. (2017) · Advanced Materials · doi:10.1002/adma.201702243 · Cited by 462
Kinetics of skin resealing after insertion of microneedles in human subjects
Gupta, J., Gill, H. S., Andrews, S. N., & Prausnitz, M. R. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.05.021 · Cited by 342
Self-citation
Metadata
- Authors
- Lee, J. W., Choi, S., Felner, E. I., & Prausnitz, M. R.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2011-01-04
- Volume
- 7
- Issue
- 4
- Pages
- 531-539
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2140666937
- Cited by
- 301
- References
- 32
- FWCI
- 8.80
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.