The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
A Targeted and FRET‐Based Ratiometric Fluorescent Nanoprobe for Imaging Mitochondrial Hydrogen Peroxide in Living Cells
Abstract
Hydrogen peroxide (H 2 O 2) is a prominent member of the reactive oxygen species family and plays crucial roles in living organisms, thus detecting H 2 O 2 and elucidating its biological functions has become an important area of biological and biomedical research. Herein, a multifunctional fluorescent nanoprobe is demonstrated for detecting mitochondrial H 2 O 2. The nanoprobe is prepared by covalently linking a mitochondria‐targeting ligand (triphenylphosphonium, TPP) and a H 2 O 2 recognition element (PFl) onto carbon dots (CDs). For this nanoprobe, the CD serves as the carrier and the FRET donor. In the presence of H 2 O 2, the PFl moieties on a CD undergo structural and spectral conversion, affording the nanoplatform a FRET‐based ratiometric probe for H 2 O 2. The nanoprobe displays excellent water dispersibility, high sensitivity and selectivity, satisfactory cell permeability, and very low cytotoxicity. Following the living cell uptake, this nanoprobe can specifically target and stain the mitochondria; and it can detect the exogenous H 2 O 2 in L929 cells, as well as the endogenously produced mitochondrial H 2 O 2 in Raw 264.7 cells upon stimulation by PMA. This study shows that CDs can serve as promising nano‐carriers for fabricating practical multifunctional fluorescent nanosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mitochondrial Dysfunction and Oxidative Stress in Neurodegenerative Diseases
Lin, M. T., & Beal, M. F. (2006) · Nature · doi:10.1038/nature05292 · Cited by 6,455
Neurodegenerative diseases and oxidative stress
Barnham, K. J., Masters, C. L., & Bush, A. I. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1330 · Cited by 3,683
Calcium, ATP, and ROS: a mitochondrial love-hate triangle
Brookes, P. S., Yoon, Y., Robotham, J. L., Anders, M. W., & Sheu, S.-S. (2004) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00139.2004 · Cited by 2,575
Chemistry and biology of reactive oxygen species in signaling or stress responses
Dickinson, B. C., & Chang, C. J. (2011) · Nature Chemical Biology · doi:10.1038/nchembio.607 · Cited by 1,821
Targeting Antioxidants to Mitochondria by Conjugation to Lipophilic Cations
Murphy, M. P., & Smith, R. A. J. (2007) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev.pharmtox.47.120505.105110 · Cited by 1,173
The common biology of cancer and ageing
Finkel, T., Serrano, M., & Blasco, M. A. (2007) · Nature · doi:10.1038/nature05985 · Cited by 988
Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species
Chen, X., Tian, X., Shin, I., & Yoon, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15037e · Cited by 980
Unraveling the biological roles of reactive oxygen species
Murphy, M. P., Holmgren, A., Larsson, N.-G., Halliwell, B., Chang, C. J., Kalyanaraman, B., Rhee, S. G., Thornalley, P. J., Partridge, L., Gems, D., et al. (2011) · Cell Metabolism · doi:10.1016/j.cmet.2011.03.010 · Cited by 836
Cited by
Carbon quantum dots: synthesis, properties and applications
Wang, Y., & Hu, A. (2014) · Journal of Materials Chemistry C · doi:10.1039/c4tc00988f · Cited by 2,597
Chen, X., Wang, F., Hyun, J. Y., Wei, T., Qiang, J., Ren, X., Shin, I., & Yoon, J. (2016) · Chem. Soc. Rev. · doi:10.1039/c6cs00192k · Cited by 1,166
Ratiometric optical nanoprobes enable accurate molecular detection and imaging
Huang, X., Song, J., Yung, B. C., Huang, X., Xiong, Y., & Chen, X. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00612h · Cited by 820
Discerning the Chemistry in Individual Organelles with Small‐Molecule Fluorescent Probes
Xu, W., Zeng, Z., Jiang, J., Chang, Y., & Yuan, L. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201510721 · Cited by 808
Carbon dots: large-scale synthesis, sensing and bioimaging
Zhang, J., & Yu, S.-H. (2016) · Materials Today · doi:10.1016/j.mattod.2015.11.008 · Cited by 724
Metadata
- Authors
- Du, F., Min, Y., Zeng, F., Yu, C., & Wu, S.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2013-09-23
- Volume
- 10
- Issue
- 5
- Pages
- 964-972
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2088547455
- Cited by
- 161
- References
- 8
- FWCI
- 5.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Targeted and FRET‐Based Ratiometric Fluorescent Nanoprobe for Imaging Mitochondrial Hydrogen Peroxide in Living Cells. https://app.cochat.ai/papers/10.1002/smll.201302036
- The paper
- Du, F., Min, Y., Zeng, F., Yu, C., & Wu, S. (2014). A Targeted and FRET‐Based Ratiometric Fluorescent Nanoprobe for Imaging Mitochondrial Hydrogen Peroxide in Living Cells. Small. https://doi.org/10.1002/smll.201302036
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.