Cited by 97Gas Sensing Nanomaterials and SensorsAdvanced Sensor and Energy Harvesting MaterialsConducting polymers and applications

Ion‐Conductive Hydrogel‐Based Stretchable, Self‐Healing, and Transparent NO 2 Sensor with High Sensitivity and Selectivity at Room Temperature

Wu, Zixuan, Rong, Limin, Yang, Jinglan, Wei, Yaoming, Tao, Kai, Zhou, Yubin, Yang, Bo‐Ru, Xie, Xi +1 more·2021·Small

Abstract

Here stretchable, self‐healable, and transparent gas sensors based on salt‐infiltrated hydrogels for high‐performance NO 2 sensing in both anaerobic environment and air at room temperature, are reported. The salt‐infiltrated hydrogel displays high sensitivity to NO 2 (119.9%/ppm), short response and recovery time (29.8 and 41.0 s, respectively), good linearity, low theoretical limit of detection (LOD) of 86 ppt, high selectivity, stability, and conductivity. A new gas sensing mechanism based on redox reactions occurring at the electrode–hydrogel interface is proposed to understand the sensing behaviors. The gas sensing performance of hydrogel is greatly improved by incorporating calcium chloride (CaCl 2 ) in the hydrogel via a facile salt‐infiltration strategy, leading to a higher sensitivity (2.32 times) and much lower LOD (0.06 times). Notably, both the gas sensing ability, conductivity, and mechanical deformability of hydrogels are readily self‐healable after cutting off and reconnection. Such large deformations as 100% strain do not deprive the gas sensing capability, but rather shorten the response and recovery time significantly. The CaCl 2 ‐infiltrated hydrogel shows excellent selectivity of NO 2 , with good immunity to the interference gases. These results indicate that the salt‐infiltrated hydrogel has great potential for wearable electronics equipped with gas sensing capability in both anaerobic and aerobic environments.

Integrity signals

Registry

Crossref · 10.1002/smll.202104997

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Addition of CaCl2 to PAM/Carr DN hydrogels enhanced conductivity, inhibited dissolution of NH3 and other gases, and improved NO2 selectivity of the hydrogel.

    “The addition of CaCl2 enhanced the conductivity, inhibited the dissolution of NH3 and other gases, and improved the NO2 selectivity of the hydrogel”
  • Addition of CaCl2 promoted the redox NO2 reaction in the hydrogel and electrode, enhancing the response characteristics of the hydrogel.

    “it promoted the redox NO2 reaction in the hydrogel and electrode, which enhanced the response characteristics of the hydrogel”
  • The sensitive characteristics of the sensor are not affected by tensile deformation, and it can maintain the sensing of NO2 even at 100% strain with shortened response and recovery time.

    “Moreover, the sensitive characteristics of the sensor are not affected by tensile deformation, and it can maintain the sensing of NO2 even at 100% strain with shortened response and recovery time.”
  • In the presence of CaCl2, the PAM/Carr DN hydrogel NO2 sensor exhibited a high sensitivity of 119.9%, short response and recovery time (29.8 and 41.0 s, respectively), good linearity, low theoretical LOD of 86 ppt, high selectivity, stability, and ionic conductivity.

    “In the presence of CaCl2, this hydrogel NO2 sensor exhibited a high sensitivity of 119.9%, short response and recovery time (29.8 and 41.0 s, respectively), good linearity, low theoretical limit of detection (LOD) of 86 ppt, high selectivity, stability, and ionic conductivity.”
  • Under the same temperature and humidity, the NO2 response of the sensor with five turns of the Ag electrode was significantly greater than that with one turn.

    “Under the same temperature and humidity, the NO2 response of the sensor with five turns of the Ag electrode was significantly greater than that with one turn, as depicted in Fig. 6f.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Wu, Z., Rong, L., Yang, J., Wei, Y., Tao, K., Zhou, Y., Yang, B., Xie, X., & Wu, J.
Affiliations
  • Sun Yat-sen University (CN)
  • Northwestern Polytechnical University (CN)
  • Guangdong Medical College (CN)
Corresponding author
Wu, Jin
Venue
Small
Publisher
Wiley
Published
2021-10-20
Volume
17
Issue
52
Pages
e2104997-e2104997
ISSN
  • 1613-6810 (ISSN-L)
  • 1613-6829
OpenAlex
W3207077743
Cited by
97
References
4
Citations by year
2026: 11 · 2025: 20 · 2024: 18 · 2023: 19 · 2022: 27 · 2021: 2
FWCI
4.85
Type
journal article
Language
en
Open access
closed
Locations
  • Small (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Natural Science Foundation of China (61801525)
  • Fundamental Research Funds for the Central Universities (2021qntd09)
  • Natural Science Foundation of Guangdong Province (2018A030313400)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
Keywords
NO2 gas sensor, self-healing hydrogels, salt infiltration, calcium chloride, wearable electronics, room-temperature gas sensing
MeSH terms
Wearable Electronic Devices, Electric Conductivity, Nitrogen Dioxide, Temperature, Hydrogels

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review