Scanning Transmission Electron Microscopy
The DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
The scanning transmission electron microscope () has become one of the preeminent instruments for high spatial resolution imaging and spectroscopy of materials, most notably at atomic resolution. The principle of STEM is quite straightforward. A beam of electrons is focused by electron optics to form a small illuminating probe that is raster-scanned across a sample. The sample is thinned such that the vast majority of electrons are transmitted, and the scattered electrons detected using some geometry of detector. The intensity as a function of probe position forms an image. It is the wide variety of possible detectors, and therefore imaging and spectroscopy modes, that gives STEM its strength. The purpose of this chapter is to describe what the STEM is, to highlight some of the types of experiment that can be performed using a STEM, to explain the principles behind the common modes of operation, to illustrate the features of typical STEM instrumentation, and to discuss some of the limiting factors in its performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251 · cited 2×
“In optics, the Van Cittert–Zernicke theorem (Born and Wolf, 1980) describes how an extended source gives rise to a coherent envelope that is the Fourier transform of the source intensity function.”
BackgroundMethodGABOR, D. (1948) · Nature · doi:10.1038/161777a0 · Cited by 4,548 · cited 2×
“Finally it is worth noting that an electron shadow image for a weakly scattering sample is actually an in-line hologram (Lin and Cowley, 1986) as fi rst proposed by Gabor (1948) for the correction of lens aberrations.”
BackgroundElectron Microscopy of Thin Crystals
(1963) · Nature · doi:10.1038/197438d0 · Cited by 3,989 · cited 1×
“…in the detector plane, K, is related to the scattering angle, q, by K = θ λ (3.2) A detailed discussion of electron diffraction is in general beyond the scope of this text, but the reader is referred to the many excellent textbooks on this subject (Hirsch et al., 1977; Cowley, 1990, 1992).”
BackgroundInfluentialTransmission Electron Microscopy
Williams, D. B., & Carter, C. B. (2009) · Springer eBooks · doi:10.1007/978-0-387-76501-3 · Cited by 3,963 · cited 1×
“The technique of EDX microanalysis in CTEM and STEM has been extensively covered (Williams and Carter, 1996), and we will review here only the specifi c features of EDX in a STEM.”
MethodElectron Energy-Loss Spectroscopy in the Electron Microscope
Egerton, R. F., & Newbury, D. E. (1987) · Physics Today · doi:10.1063/1.2820276 · Cited by 3,415
Atom-by-atom structural and chemical analysis by annular dark-field electron microscopy
Krivanek, O. L., Chisholm, M. F., Nicolosi, V., Pennycook, T. J., Corbin, G. J., Dellby, N., Murfitt, M. F., Own, C. S., Szilagyi, Z. S., Oxley, M. P., et al. (2010) · Nature · doi:10.1038/nature08879 · Cited by 1,352
Electron microscopy image enhanced
Haider, M., Uhlemann, S., Schwan, E., Rose, H., Kabius, B., & Urban, K. (1998) · Nature · doi:10.1038/33823 · Cited by 1,057
Production and application of electron vortex beams
Verbeeck, J., Tian, H., & Schattschneider, P. (2010) · Nature · doi:10.1038/nature09366 · Cited by 879
Crewe, A. V., Wall, J., & Langmore, J. (1970) · Science · doi:10.1126/science.168.3937.1338 · Cited by 752
Krivanek, O. L., Dellby, N., & Lupini, A. R. (1999) · Ultramicroscopy · doi:10.1016/s0304-3991(99)00013-3 · Cited by 719
Experimental High-Resolution Electron Microscopy
Spence, J. C. H., & Crewe, A. V. (1981) · Physics Today · doi:10.1063/1.2914772 · Cited by 712
High-resolution incoherent imaging of crystals
Pennycook, S. J., & Jesson, D. E. (1990) · Physical Review Letters · doi:10.1103/physrevlett.64.938 · Cited by 688 · cited 2×
“In this approach the intensity of the wavefunction at each site needs to be computed using a dynamic elastic scattering model and then the TDS from each atom summed (Pennycook and Jesson, 1990).”
MethodFree-standing graphene at atomic resolution
Gass, M. H., Bangert, U., Bleloch, A. L., Wang, P., Nair, R. R., & Geim, A. K. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.280 · Cited by 640
Z-contrast stem for materials science
Pennycook, S. J. (1989) · Ultramicroscopy · doi:10.1016/0304-3991(89)90173-3 · Cited by 580 · cited 2×
“Both the Bloch wave (for example, Pennycook, 1989; Amali and Rez, 1997; Mitsuishi et al., 2001; Findlay et al., 2003b) and multislice (for example, Dinges et al., 1995; Allen et al., 2003) methods have been used for simulating the TDS scattering to the ADF detector.”
MethodInfluentialAtomic-resolution chemical analysis using a scanning transmission electron microscope
Browning, N. D., Chisholm, M. F., & Pennycook, S. J. (1993) · Nature · doi:10.1038/366143a0 · Cited by 536
Direct Sub-Angstrom Imaging of a Crystal Lattice
Nellist, P. D., Chisholm, M. F., Dellby, N., Krivanek, O. L., Murfitt, M. F., Szilagyi, Z. S., Lupini, A. R., Borisevich, A., Sides, W. H., & Pennycook, S. J. (2004) · Science · doi:10.1126/science.1100965 · Cited by 533
Self-citationIncoherent imaging using dynamically scattered coherent electrons
Nellist, P. D., & Pennycook, S. J. (1999) · Ultramicroscopy · doi:10.1016/s0304-3991(99)00017-0 · Cited by 495
Self-citationDynamics of annular bright field imaging in scanning transmission electron microscopy
Findlay, S. D., Shibata, N., Sawada, H., Okunishi, E., Kondo, Y., & Ikuhara, Y. (2010) · Ultramicroscopy · doi:10.1016/j.ultramic.2010.04.004 · Cited by 495
Differential phase-contrast microscopy at atomic resolution
Shibata, N., Findlay, S. D., Kohno, Y., Sawada, H., Kondo, Y., & Ikuhara, Y. (2012) · Nature Physics · doi:10.1038/nphys2337 · Cited by 468
Atomic-scale imaging of individual dopant atoms and clusters in highly n-type bulk Si
Voyles, P. M., Muller, D. A., Grazul, J. L., Citrin, P. H., & Gossmann, H.-J. L. (2002) · Nature · doi:10.1038/416826a · Cited by 434
A spherical-aberration-corrected 200kV transmission electron microscope
Haider, M., Rose, H., Uhlemann, S., Schwan, E., Kabius, B., & Urban, K. (1998) · Ultramicroscopy · doi:10.1016/s0304-3991(98)00048-5 · Cited by 426
Conditions and reasons for incoherent imaging in STEM
Hartel, P., Rose, H., & Dinges, C. (1996) · Ultramicroscopy · doi:10.1016/0304-3991(96)00020-4 · Cited by 411
XV. On the theory of optical images, with special reference to the microscope
Rayleigh (1896) · The London Edinburgh and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786449608620902 · Cited by 386 · cited 2×
“The difference between coherent and incoherent imaging was discussed at length by Lord Rayleigh in his classic paper discussing the resolution limit of the microscope (Rayleigh, 1896).”
BackgroundQuantitative Atomic Resolution Scanning Transmission Electron Microscopy
LeBeau, J. M., Findlay, S. D., Allen, L. J., & Stemmer, S. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.206101 · Cited by 382
Simultaneous STEM imaging and electron energy-loss spectroscopy with atomic-column sensitivity
Batson, P. E. (1993) · Nature · doi:10.1038/366727a0 · Cited by 372 · cited 23×
“The collection effi ciency of EELS can reach 50%, compared to around 1% for EDX, because the X-rays are emitted isotropically.”
BackgroundInfluentialSimulation of annular dark field stem images using a modified multislice method
Kirkland, E. J., Loane, R. F., & Silcox, J. (1987) · Ultramicroscopy · doi:10.1016/0304-3991(87)90229-4 · Cited by 349
The principles and interpretation of annular dark-field Z-contrast imaging
Nellist, P. D., & Pennycook, S. J. (2000) · Advances in Imaging and Electron Physics · doi:10.1016/s1076-5670(00)80013-0 · Cited by 339 · cited 3×
“Various methods have been applied to this deconvolution problem (Nellist and Pennycook, 1998a, 2000) including Bayesian methods (McGibbon et al., 1994, 1995).”
BackgroundMethodSelf-citationDirect Imaging of the Atomic Configuration of Ultradispersed Catalysts
Nellist, P. D., & Pennycook, S. J. (1996) · Science · doi:10.1126/science.274.5286.413 · Cited by 322
Self-citationAtomic-resolution imaging of oxidation states in manganites
Varela, M., Oxley, M. P., Luo, W., Tao, J., Watanabe, M., Lupini, A. R., Pantelides, S. T., & Pennycook, S. J. (2009) · Physical Review B · doi:10.1103/physrevb.79.085117 · Cited by 320
Progress in aberration-corrected scanning transmission electron microscopy
Dellby, N., Krivanek, O. L., Nellist, P. D., Batson, P. E., & Lupini, A. R. (2001) · Microscopy · doi:10.1093/jmicro/50.3.177 · Cited by 303 · cited 4×
“This is the method invented by Krivanek et al. (Dellby et al., 2001) for autotuning of a STEM aberration corrector.”
BackgroundMethodInfluentialSelf-citationThe Peak Pairs algorithm for strain mapping from HRTEM images
Galindo, P. L., Kret, S., Sanchez, A. M., Laval, J.-Y., Yáñez, A., Pizarro, J., Guerrero, E., Ben, T., & Molina, S. I. (2007) · Ultramicroscopy · doi:10.1016/j.ultramic.2007.01.019 · Cited by 279
Rossouw, D., Couillard, M., Vickery, J., Kumacheva, E., & Botton, G. A. (2011) · Nano Letters · doi:10.1021/nl200634w · Cited by 271
Practical aspects of atomic resolution imaging and analysis in STEM
James, E. M., & Browning, N. D. (1999) · Ultramicroscopy · doi:10.1016/s0304-3991(99)00018-2 · Cited by 271
Delocalization in inelastic scattering
Muller, D. A., & Silcox, J. (1995) · Ultramicroscopy · doi:10.1016/0304-3991(95)00029-z · Cited by 268
Mapping sp2 and sp3 states of carbon at sub-nanometre spatial resolution
Muller, D. A., Tzou, Y., Raj, R., & Silcox, J. (1993) · Nature · doi:10.1038/366725a0 · Cited by 243 · cited 3×
“An example of this is the mapping of the sp2 and sp3 bonding states of carbon at the interface of chemical vapor deposition diamond grown on a silicon substrate (Muller et al., 1993) (Figure 2–20).”
BackgroundInfluentialIncoherent imaging of crystals using thermally scattered electrons
Jesson, D. E., & Pennycook, S. J. (1995) · Proceedings of the Royal Society of London. Series A: Mathematical and Physical Sciences · doi:10.1098/rspa.1995.0044 · Cited by 222 · cited 1×
“Jesson and Pennycook (1995) have considered the case for a more realistic phonon dispersion, and showed that a coherence envelope parallel to the beam direction can be defi ned.”
BackgroundIncoherent imaging of zone axis crystals with ADF STEM
Loane, R. F., Xu, P., & Silcox, J. (1992) · Ultramicroscopy · doi:10.1016/0304-3991(92)90054-n · Cited by 219
DIFFERENTIAL PHASE CONTRAST IN A STEM.
Dekkers, N. H., & De Lang, H. (1974) · Cited by 179
Composition mapping in InGaN by scanning transmission electron microscopy
Rosenauer, A., Mehrtens, T., Müller‐Caspary, K., Gries, K. I., Schowalter, M., Satyam, P. V., Bley, S., Tessarek, C., Hommel, D., Sebald, K., et al. (2011) · Ultramicroscopy · doi:10.1016/j.ultramic.2011.04.009 · Cited by 178
Bonnet, N., Brun, N., & Colliex, C. (1999) · Ultramicroscopy · doi:10.1016/s0304-3991(99)00042-x · Cited by 176
Imaging elastic strains in high-angle annular dark field scanning transmission electron microscopy
Perovic, D. D., Rossouw, C. J., & Howie, A. (1993) · Ultramicroscopy · doi:10.1016/0304-3991(93)90046-z · Cited by 175
Inelastic scattering probabilities in scanning transmission electron microscopy
Ritchie, R. H., & Howie, A. (1988) · Philosophical magazine. A/Philosophical magazine. A. Physics of condensed matter. Structure, defects and mechanical properties · doi:10.1080/01418618808209951 · Cited by 167
On the Theory of Optical Images, with Special Reference to the Microscope
Rayleigh, L. (1903) · Journal of the Royal Microscopical Society · doi:10.1111/j.1365-2818.1903.tb04830.x · Cited by 157
A brief look at imaging and contrast transfer
Wade, R. H. (1992) · Ultramicroscopy · doi:10.1016/0304-3991(92)90011-8 · Cited by 156
Incoherent imaging of thin specimens using coherently scattered electrons
Jesson, D. E., & Pennycook, S. J. (1993) · Proceedings of the Royal Society of London Series A Mathematical and Physical Sciences · doi:10.1098/rspa.1993.0060 · Cited by 151 · cited 2×
“This is essentially the result derived by Jesson and Pennycook (1993).”
BackgroundMethodStructure determination through Z-contrast microscopy
Pennycook, S. J. (2002) · Advances in Imaging and Electron Physics · doi:10.1016/s1076-5670(02)80063-5 · Cited by 140 · cited 1×
“The use of ADF imaging for structure determination is now widespread (Pennycook, 2002).”
Spence, J. C. H., & COWLEY, J. M. (1978) · Cited by 135
Allen, L. J., Findlay, S. D., Lupini, A. R., Oxley, M. P., & Pennycook, S. J. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.105503 · Cited by 119
Spherical aberration and the information content of optical images
Black, G., & Linfoot, E. H. (1957) · Proceedings of the Royal Society of London A Mathematical and Physical Sciences · doi:10.1098/rspa.1957.0059 · Cited by 106 · cited 1×
“In general it is a positive, monatonically decaying function (see Black and Linfoot (1957) for examples under various conditions), which compares favorably with the phase contrast transfer function for the same lens parameters (Figure 2–12).”
BackgroundAccurate structure determination from image reconstruction in ADF STEM
Nellist, P. D., & Pennycook, S. J. (1998) · Journal of Microscopy · doi:10.1046/j.1365-2818.1998.3260881.x · Cited by 100
Self-citationDepth-Dependent Imaging of Individual Dopant Atoms in Silicon
Voyles, P. M., Muller, D. A., & Kirkland, E. J. (2004) · Microscopy and Microanalysis · doi:10.1017/s1431927604040012 · Cited by 91
Measurement method of aberration from Ronchigram by autocorrelation function
Sawada, H., Sannomiya, T., Hosokawa, F., Nakamichi, T., Kaneyama, T., Tomita, T., Kondo, Y., Tanaka, T., Oshima, Y., Tanishiro, Y., et al. (2008) · Ultramicroscopy · doi:10.1016/j.ultramic.2008.04.095 · Cited by 90
Behan, G., Cosgriff, E. C., Kirkland, A. I., & Nellist, P. D. (2009) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2009.0074 · Cited by 77
Self-citationOrigin of Anomalous Pt–Pt Distances in the Pt/Alumina Catalytic System
Sohlberg, K. W., Rashkeev, S. N., Borisevich, A. Y., Pennycook, S. J., & Pantelides, S. T. (2004) · ChemPhysChem · doi:10.1002/cphc.200400212 · Cited by 76
On the origin of transverse incoherence in Z-contrast STEM
Rafferty, B., Nellist, D., & Pennycook, S. J. (2001) · Microscopy · doi:10.1093/jmicro/50.3.227 · Cited by 76 · cited 1×
“Because these states are highly nondispersive, spreading of the probe wavefunction into neighboring column 1s states is unlikely (Rafferty et al., 2001), although spreading into less bound states on neighboring columns is possible.”
BackgroundAnderson, S. C., Birkeland, C. R., Anstis, G. R., & Cockayne, D. J. H. (1997) · Ultramicroscopy · doi:10.1016/s0304-3991(97)00041-7 · Cited by 70 · cited 2×
“There have been several examples of the application to AlGaAs quantum well structures (see, for example, Anderson et al., 1997).”
BackgroundMethodAdjustment of a STEM instrument by use of shadow images
COWLEY, J. M. (1979) · Ultramicroscopy · doi:10.1016/s0304-3991(79)80018-2 · Cited by 68 · cited 30×
“The coma free axis is immediately obvious in a Ronchigram, and astigmatism and focus can be carefully adjusted by observation of the magnifi cation of the speckle contrast.”
BackgroundMethodInfluentialTheory of Lattice Resolution in High-angle Annular Dark-field Images
Amali, A., & Rez, P. (1997) · Microscopy and Microanalysis · doi:10.1017/s1431927697970021 · Cited by 68
Towards atomic column-by-column spectroscopy
Rafferty, B., & Pennycook, S. J. (1999) · Ultramicroscopy · doi:10.1016/s0304-3991(99)00033-9 · Cited by 64
Localization in elastic and inelastic scattering
Lupini, A. R., & Pennycook, S. J. (2003) · Ultramicroscopy · doi:10.1016/s0304-3991(03)00096-2 · Cited by 63
The physics of the high-resolution scanning microscope
Crewe, A. V. (1980) · Reports on Progress in Physics · doi:10.1088/0034-4885/43/5/002 · Cited by 40 · cited 2×
“Annular dark-fi eld imaging was introduced in the fi rst STEMs built in Crewe’s laboratory (Crewe, 1980).”
BackgroundMethodMitsuishi, K., Takeguchi, M., Yasuda, H., & Furuya, K. (2001) · Microscopy · doi:10.1093/jmicro/50.3.157 · Cited by 15 · cited 2×
“Both the Bloch wave (for example, Pennycook, 1989; Amali and Rez, 1997; Mitsuishi et al., 2001; Findlay et al., 2003b) and multislice (for example, Dinges et al., 1995; Allen et al., 2003) methods have been used for simulating the TDS scattering to the ADF detector.”
BackgroundMethodInfluential
Cited by
Soft X-ray microscopes and their biological applications
Kirz, J., Jacobsen, C., & Howells, M. (1995) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500003139 · Cited by 672
Ziatdinov, M., Dyck, O., Maksov, A., Li, X., Sang, X., Xiao, K., Unocic, R. R., Vasudevan, R., Jesse, S., & Kalinin, S. V. (2017) · ACS Nano · doi:10.1021/acsnano.7b07504 · Cited by 421
Deciphering chemical order/disorder and material properties at the single-atom level
Yang, Y., Chen, C.-C., Scott, M. C., Ophus, C., Xu, R., Pryor, A., Wu, L., Sun, F., Theis, W., Zhou, J., et al. (2017) · Nature · doi:10.1038/nature21042 · Cited by 357
The principles and interpretation of annular dark-field Z-contrast imaging
Nellist, P. D., & Pennycook, S. J. (2000) · Advances in Imaging and Electron Physics · doi:10.1016/s1076-5670(00)80013-0 · Cited by 339
Self-citationObserving crystal nucleation in four dimensions using atomic electron tomography
Zhou, J., Yang, Y., Yang, Y., Kim, D. S., Yuan, A., Tian, X., Ophus, C., Sun, F., Schmid, A. K., Nathanson, M., et al. (2019) · Nature · doi:10.1038/s41586-019-1317-x · Cited by 336
Metadata
- Authors
- Nellist, P. D.
- Venue
- Science of Microscopy
- Publisher
- Springer New York
- Published
- 2008-08-29
- Pages
- 65-132
- OpenAlex
- W234463455
- Cited by
- 217
- References
- 62
- FWCI
- 18.46
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.