Persistent Angular Structure: New Insights from Diffusion MRI Data. Dummy Version
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
Park, G. S. (1975) · Polymer · doi:10.1016/0032-3861(75)90130-5 · Cited by 14,967
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286 · cited 1×
“In diffusion MRI, measurements are commonly made using the Stejskal–Tanner pulsed gradient spin echo (PGSE) method [ 5 ], which samples the Fourier transform of p. Two magnetic field gradient pulses of duration δ and separation ∆ are introduced to the simple spin-echo sequence.”
MethodMR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970 · cited 1×
“Diffusion MRI and, in particular, diffusion tensor magnetic resonance imaging (DT-MRI) [ 1 ] is popular in biomedical imaging because of the insight it provides into the microstructure of biological tissue [2,3].”
BackgroundBasser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Principles of Nuclear Magnetic Resonance Microscopy
Callaghan, P. T. (1991) · doi:10.1093/oso/9780198539445.001.0001 · Cited by 3,599
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Automated Image Registration: I. General Methods and Intrasubject, Intramodality Validation
Woods, R. P., Grafton, S. T., Holmes, C. J., Cherry, S. R., & Mazziotta, J. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199801000-00027 · Cited by 1,707
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403 · cited 1×
“Because of the effects of noise, acquiring more than six A(q) provides a better approximation of D .A common approach [ 10 ] is to acquire M measurements of A � (0) together with measurements A � (qj), 1 ≤ j ≤ N , for which δ, ∆, and |q| are fixed, but each ˆ qj is unique.”
Background(2004) · Kinetic Processes · doi:10.1002/3527603891.ch7 · Cited by 1,010
Cited by
Probabilistic diffusion tractography with multiple fibre orientations: What can we gain?
Behrens, T. E. J., Berg, H. J., Jbabdi, S., Rushworth, M. F. S., & Woolrich, M. W. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.018 · Cited by 3,471
“In each data set, each scan was subsequently aligned to a reference (b = 0) scan using affine registration intended to maximise mutual information (Jenkinson and Smith, 2001).”
MethodDiffusion tensor imaging (DTI)-based white matter mapping in brain research: a review
Assaf, Y., & Pasternak, O. (2008) · Journal of Molecular Neuroscience · doi:10.1007/s12031-007-0029-0 · Cited by 1,537
“Areas of tissue partial volume (where white/gray matter or white matter/CSF reside in the same pixel) or of white matter partial volume (where two fiber systems cross the same pixel often in different orientations) are examples of where the DTI model will fail (Papadakis et al. 2002; Tuch et al. 2002; Jansons and Alex…”
BackgroundMethodInfluentialMapping complex tissue architecture with diffusion spectrum magnetic resonance imaging
Wedeen, V. J., Hagmann, P., Tseng, W. I., Reese, T. G., & Weisskoff, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20642 · Cited by 1,339
Diffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
A hitchhiker's guide to diffusion tensor imaging
Soares, J. M., Marques, P., Alves, V., & Sousa, N. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00031 · Cited by 893
“…Q-Ball Imaging (QBI), Q-Space Imaging (QSI), Spherical Deconvolution Model, and Persistent Angular Structure MRI (PAS-MRI) (Tuch et al., 2002; Jansons and Alexander, 2003; Tuch, 2004; Alexander et al., 2006; Wedeen et al., 2008; Assemlal et al., 2011; Tournier et al., 2011; Landman et al.,…”
MethodHagmann, P., Jonasson, L., Maeder, P., Thiran, J.-P., Wedeen, V. J., & Meuli, R. (2006) · RadioGraphics · doi:10.1148/rg.26si065510 · Cited by 759
White matter fiber tractography: why we need to move beyond DTI: Clinical article
Farquharson, S., Tournier, J.-D., Calamante, F., Fabinyi, G., Schneider-Kolsky, M., Jackson, G. D., & Connelly, A. (2013) · Journal of Neurosurgery · doi:10.3171/2013.2.jns121294 · Cited by 469
Measurement of fiber orientation distributions using high angular resolution diffusion imaging
Anderson, A. W. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20667 · Cited by 463
Powell, H. W. R., Parker, G. J. M., Alexander, D. C., Symms, M. R., Boulby, P. A., Wheeler-Kingshott, C. A. M., Barker, G. J., Noppeney, U., Koepp, M. J., & Duncan, J. S. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.03.011 · Cited by 414
Self-citationProbabilistic fiber tracking using the residual bootstrap with constrained spherical deconvolution
Jeurissen, B., Leemans, A., Jones, D. K., Tournier, J., & Sijbers, J. (2011) · Human Brain Mapping · doi:10.1002/hbm.21032 · Cited by 369
Characterizing brain anatomical connections using diffusion weighted MRI and graph theory
Iturria-Medina, Y., Canales-Rodríguez, E. J., Melie-García, L., Valdés-Hernández, P. A., Martínez-Montes, E., Alemán-Gómez, Y., & Sánchez-Bornot, J. M. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.012 · Cited by 340
Parker, G. J. M., & Alexander, D. C. (2005) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2005.1639 · Cited by 339
Self-citationLambert, C., Zrinzo, L., Nagy, Z., Lutti, A., Hariz, M., Foltynie, T., Draganski, B., Ashburner, J., & Frackowiak, R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.082 · Cited by 336
Hagler, D. J., Ahmadi, M. E., Kuperman, J., Holland, D., McDonald, C. R., Halgren, E., & Dale, A. M. (2009) · Human Brain Mapping · doi:10.1002/hbm.20619 · Cited by 293
White, N. S., Leergaard, T. B., D'Arceuil, H., Bjaalie, J. G., & Dale, A. M. (2013) · Human Brain Mapping · doi:10.1002/hbm.21454 · Cited by 273
Filtered multitensor tractography
Malcolm, J. G., Shenton, M. E., & Rathi, Y. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2048121 · Cited by 247
Behrens, T. E., & Sporns, O. (2012) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2011.08.005 · Cited by 237
“Using diffusion-weighted MRI, we can measure this anisotropy and the peak diffusion orientations in each imaging voxel [9] [10] [11] [12] (Fig.”
Yousaf, T., Dervenoulas, G., & Politis, M. (2018) · International Review of Neurobiology · doi:10.1016/bs.irn.2018.08.008 · Cited by 225
A novel tensor distribution model for the diffusion-weighted MR signal
Jian, B., Vemuri, B. C., Özarslan, E., Carney, P. R., & Mareci, T. H. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.03.074 · Cited by 217
“Biomimetics, LIMB, NICHD, National Institutes of Health, Bethesda, MD, United States, 3Department of Pediatrics, University of Florida, Gainesville, FL, United States, 4Department of Biochemistry and Molecular Biology, University of Florida, Gainesville, FL, United States”
BackgroundIrfanoglu, M. O., Walker, L., Sarlls, J., Marenco, S., & Pierpaoli, C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.02.054 · Cited by 215
“…applied in diffusion MRI tractography for both DTI and other HARDI schemes such as DSI (Tuch, 2002), Q-ball imaging (Tuch, December, 2004), PASMRI (Jansons and Alexander, 2003) Population average SCP tract for RL and AP data for both corrected and uncorrected cases, displayed in three main views.…”
BackgroundMethodInfluentialHistological validation of diffusion MRI fiber orientation distributions and dispersion
Schilling, K. G., Janve, V., Gao, Y., Stepniewska, I., Landman, B. A., & Anderson, A. W. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.10.046 · Cited by 195
“…(PAS): using another function on the unit sphere, PAS MRI attempts to capture the angular structure of the diffusion propagator that persists over the most important range of diffusion displacements, and it is intended to reflect the angular structure of the FOD (Jansons and Alexander, 2003).”
InfluentialVestergaard, M., Madsen, K. S., Baaré, W. F. C., Skimminge, A., Ejersbo, L. R., Ramsøy, T. Z., Gerlach, C., Åkeson, P., Paulson, O. B., & Jernigan, T. L. (2011) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2010.21592 · Cited by 181
Irfanoglu, M. O., Modi, P., Nayak, A., Hutchinson, E. B., Sarlls, J., & Pierpaoli, C. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.11.042 · Cited by 175
“, 1996) and high angular resolution diffusion imaging (HARDi) (Wedeen et al., 2000; Tuch, 2002, 2004; Tuch et al., 1999; Frank, 2002; Jansons and Alexander, 2003) have been extensively used to investigate the architecture of the human brain.”
Wu, Y., Sun, D., Wang, Y., Wang, Y., & Ou, S. (2016) · Frontiers in Neuroanatomy · doi:10.3389/fnana.2016.00084 · Cited by 160
“HARDI has better angular resolution and smaller voxels (Jansons and Alexander, 2003), while DSI is essentially a modelfree imaging approach that has the ability to map complex fiber architecture at the scale of single MRI voxels (Wedeen et al., 2005).”
BackgroundDrakesmith, M., Caeyenberghs, K., Dutt, A., Lewis, G., David, A. S., & Jones, D. K. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.05.011 · Cited by 157
Response inhibition is associated with white matter microstructure in children.
Madsen, K. S., Baaré, W. F. C., Vestergaard, M., Skimminge, A., Ejersbo, L. R., Ramsøy, T. Z., Gerlach, C., Åkeson, P., Paulson, O. B., & Jernigan, T. L. (2010) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2009.11.001 · Cited by 104
“…non-DW images (b = 0) and 61 DW images, encoded along independent collinear diffusion gradient orientations (Cook, Symms, Boulby, & Alexander, 2007; Jansons & Alexander, 2003), were acquired with a b value of 1200 s/mm2 (TR = 8200 ms; TE = 100 ms, FOV = 220 mm × 220 mm, matrix = 96 × 96, GRAPPA:…”
Can increased spatial resolution solve the crossing fiber problem for diffusion MRI?
Schilling, K., Gao, Y., Janve, V., Stepniewska, I., Landman, B. A., & Anderson, A. W. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3787 · Cited by 102
Mayer, A. R., Ling, J. M., Dodd, A. B., Meier, T. B., Hanlon, F. M., & Klimaj, S. D. (2017) · Brain Imaging and Behavior · doi:10.1007/s11682-016-9546-1 · Cited by 45
Metadata
- Authors
- Jansons, K. M., & Alexander, D. C.
- Venue
- Lecture Notes in Computer Science
- Publisher
- Springer Berlin Heidelberg
- Published
- 2003
- Volume
- 18
- Pages
- 672-683
- ISSN
- 0302-9743 (ISSN-L)
- 1611-3349
- OpenAlex
- W2108243930
- Cited by
- 168
- References
- 21
- FWCI
- 13.83
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.