Chamber for indirect calorimetry with accurate measurement and time discrimination of metabolic plateaus of over 20 min

Nguyen, T., de Jonge, L., Smith, S. R., Bray, G. A.·2003·Medical and Biological Engineering and Computing

Abstract

A robust algorithm for pull-calorimeters that provides a rapid response to changes in respiratory gas exchange has been implemented. Metabolic plateaus (over 20 min), such as that generated by steady treadmill exercise, can be measured accurately (< 2.0% error for an energy expenditure level of 16.7 kJ min(-1)). The time resolution for changes between plateaus can be accurately found with 1 min discrimination. Implementation required only software changes but no structural or instrumentation changes to the chamber. The algorithm was based on the one developed for the push-calorimeter at the Sahlgrenska Hospital in Sweden. The method utilises published equations for the rate of O2 consumption and CO2 production in the chamber, along with techniques for suppressing noise and identifying trends. Using the exact solution of the equations for steady state, the O2 concentrations from the preceding 30 min period are fitted to two connected exponential segments, of variable length, using the least-squares method. The smoothed O2 concentration and associated time derivative are then determined for the time point 15 min earlier and substituted into the respiration equations. The CO2 concentrations are subjected to the same analysis. The process is repeated every minute, and the newly computed rates of O2 consumption and CO2 production, as well as metabolic rate, are then presented. Gas injection tests proved that the chamber can respond instantaneously to a change from one steady state of respiration to another and correctly averages repeated changes in respiration with periods less than 15min (< 1.4% error for simulated, alternating O2 consumption levels of 0.81 min (-1) and 0.01 min). The successful integration of the algorithm into the Pennington chambers allows for traditional 24 h energy expenditure measurements and various metabolic experiments requiring rapid responses.

Integrity signals

Registry

Crossref · 10.1007/bf02345320

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Nguyen, T., de Jonge, L., Smith, S. R., & Bray, G. A.
Affiliations
Pennington Biomedical Research Center (US)
Corresponding author
Nguyen, T.
Venue
Medical and Biological Engineering and Computing
Published
2003-09
Volume
41
Issue
5
Pages
572-578
ISSN
  • 0140-0118 (ISSN-L)
  • 1741-0444
OpenAlex
W2025865777
Cited by
47
References
7
Citations by year
2026: 1 · 2025: 2 · 2024: 1 · 2023: 2 · 2020: 3 · 2019: 2 · 2018: 4 · 2017: 4 · 2016: 3 · 2014: 1 · 2013: 4 · 2012: 1
FWCI
4.23
Type
journal article
Language
en
Open access
closed
Locations
  • Medical & Biological Engineering & Computing (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
  • Physical Sciences › Chemistry › Physical and Theoretical Chemistry › thermodynamics and calorimetric analyses
  • Health Sciences › Medicine › Surgery › Biomedical and Chemical Research
Keywords
indirect calorimetry, energy expenditure, oxygen consumption, CO2 emissions, pulmonary gas exchange, exponential fitting, temporal discrimination, metabolic rate measurement, gas injection tests, treadmill exercise
MeSH terms
Algorithms, Calorimetry, Indirect, Energy Metabolism, Humans, Pulmonary Gas Exchange, Reaction Time, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review