The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Kinematic alignment is a possible alternative to mechanical alignment in total knee arthroplasty
Abstract
PURPOSE: A systematic review was conducted to answer the following questions: (1) Does kinematically aligned (KA) total knee arthroplasty (TKA) achieve clinical outcomes comparable to those of mechanically aligned (MA) TKA? (2) How do the limb, knee, and component alignments differ between KA and MA TKA? (3) How is joint line orientation angle (JLOA) changed from the native knee in KA TKA compared to that in MA TKA? METHODS: Nine full-text articles in English that reported the clinical and radiological outcomes of KA TKA were included. Five studies had a control group of patients who underwent MA TKA. Data on patient demographics, clinical scores, and radiological results were extracted. There were two level I, one level II, three level III, and three level IV studies. Six of the nine studies used patient-specific instrumentation, one study used computer navigation, and two studies used manual instrumentation. RESULTS: The clinical outcomes of KA TKA were comparable or superior to those of MA TKA with a minimum 2-year follow-up. Limb and knee alignment in KA TKA was similar to those in MA TKA, and component alignment showed slightly more varus in the tibial component and slightly more valgus in the femoral component. The JLOA in KA TKA was relatively parallel to the floor compared to that in the native knee and not oblique (medial side up and lateral side down) compared to that in MA TKA. The implant survivorship and complication rate of the KA TKA were similar to those of the MA TKA. CONCLUSION: Similar or better clinical outcomes were produced by using a KA TKA at early-term follow-up and the component alignment differed from that of MA TKA. KA TKA seemed to restore function without catastrophic failure regardless of the alignment category up to midterm follow-up. The JLOA in KA TKA was relatively parallel to the floor similar to the native knee compared to that in MA TKA. The present review of nine published studies suggests that relatively new kinematic alignment is an acceptable and alternative alignment to mechanical alignment, which is better understood. Further validation of these findings requires more randomized clinical trials with longer follow-up. LEVEL OF EVIDENCE: Level II.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grading quality of evidence and strength of recommendations
(2004) · BMJ · doi:10.1136/bmj.328.7454.1490 · Cited by 8,477
The movement of the normal tibio-femoral joint
Freeman, M. A. R., & Pinskerova, V. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.006 · Cited by 532 · cited 1×
“KA TKA strives to satisfy three goals, which are to (1) set the six degrees of freedom of the femoral and tibial components to restore the native tibiofemoral articular surface of the knee [8, 15], (2) restore the native knee and limb alignments [10, 14–16, 18, 33, 34], and (3) restore the native laxities of the knee…”
MethodCalliess, T., Bauer, K., Stukenborg-Colsman, C., Windhagen, H., Budde, S., & Ettinger, M. (2017) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-016-4136-8 · Cited by 245
Cited by
Implant Survival and Function Ten Years After Kinematically Aligned Total Knee Arthroplasty
Howell, S. M., Shelton, T. J., & Hull, M. L. (2018) · The Journal of Arthroplasty · doi:10.1016/j.arth.2018.07.020 · Cited by 302
Self-citationBlakeney, W., Clément, J., Desmeules, F., Hagemeister, N., Rivière, C., & Vendittoli, P. (2019) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-018-5174-1 · Cited by 198
MacDessi, S. J., Griffiths-Jones, W., Harris, I. A., Bellemans, J., & Chen, D. B. (2020) · Bone & Joint Open · doi:10.1302/2633-1462.17.bjo-2020-0037.r1 · Cited by 136
Niki, Y., Nagura, T., Nagai, K., Kobayashi, S., & Harato, K. (2018) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-017-4788-z · Cited by 129
Tarassoli, P., Wood, J. A., Chen, D. B., Griffiths‐Jones, W., Bellemans, J., & MacDessi, S. J. (2022) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-022-07038-8 · Cited by 46
Metadata
- Authors
- Lee, Y. S., Howell, S. M., Won, Y.-Y., Lee, O.-S., Lee, S. H., Vahedi, H., & Teo, S. H.
- Venue
- Knee Surgery, Sports Traumatology, Arthroscopy
- Publisher
- Wiley
- Published
- 2017-04-24
- Volume
- 25
- Issue
- 11
- Pages
- 3467-3479
- ISSN
- 0942-2056 (ISSN-L)
- 1433-7347
- OpenAlex
- W2608944923
- Cited by
- 191
- References
- 3
- FWCI
- 11.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Kinematic alignment is a possible alternative to mechanical alignment in total knee arthroplasty. https://app.cochat.ai/papers/10.1007/s00167-017-4558-y
- The paper
- Lee, Y. S., Howell, S. M., Won, Y.-Y., Lee, O.-S., Lee, S. H., Vahedi, H., & Teo, S. H. (2017). Kinematic alignment is a possible alternative to mechanical alignment in total knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1007/s00167-017-4558-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.