Probeless non-invasive near-infrared spectroscopic bioprocess monitoring using microspectrometer technology
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Real-time measurements and adjustments of critical process parameters are essential for the precise control of fermentation processes and thus for increasing both quality and yield of the desired product. However, the measurement of some crucial process parameters such as biomass, product, and product precursor concentrations usually requires time-consuming offline laboratory analysis. In this work, we demonstrate the in-line monitoring of biomass, penicillin (PEN), and phenoxyacetic acid (POX) in a Penicillium chrysogenum fed-batch fermentation process using low-cost microspectrometer technology operating in the near-infrared (NIR). In particular, NIR reflection spectra were taken directly through the glass wall of the bioreactor, which eliminates the need for an expensive NIR immersion probe. Furthermore, the risk of contaminations in the reactor is significantly reduced, as no direct contact with the investigated medium is required. NIR spectra were acquired using two sensor modules covering the spectral ranges 1350–1650 nm and 1550–1950 nm. Based on offline reference analytics, partial least squares (PLS) regression models were established for biomass, PEN, and POX either using data from both sensors separately or jointly. The established PLS models were tested on an independent validation fed-batch experiment. Root mean squared errors of prediction (RMSEP) were 1.61 g/L, 1.66 g/L, and 0.67 g/L for biomass, PEN, and POX, respectively, which can be considered an acceptable accuracy comparable with previously published results using standard process spectrometers with immersion probes. Altogether, the presented results underpin the potential of low-cost microspectrometer technology in real-time bioprocess monitoring applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In [54], the authors demonstrated the use of NIR spectroscopy for in-line monitoring of biomass, penicillin (PEN), and phenoxyacetic acid (POX) in a Penicillium chrysogenum fed-batch fermentation process.”
From Spectroscopic Advances in Real Time Monitoring of Pharmaceutical Bioprocesses: A Review of Vibrational and Fluorescence Techniques (2025) · cites this paper as [54]
In the citing paper
“Biomass predictions were highly accurate, with an RMSE of 9.8% of full scale, while penicillin (PEN) and phenoxyacetic acid (POX) showed errors of 18.0% and 15.9% of full scale, respectively.”
From Spectroscopic Advances in Real Time Monitoring of Pharmaceutical Bioprocesses: A Review of Vibrational and Fluorescence Techniques (2025) · cites this paper as [54]
In the citing paper
“A key drawback of MIR is that the background solvent must be transparent within the spectral region of interest [54].”
From Spectroscopic Advances in Real Time Monitoring of Pharmaceutical Bioprocesses: A Review of Vibrational and Fluorescence Techniques (2025) · cites this paper as [54]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bioreactor monitoring with spectroscopy and chemometrics: a review
Lourenço, N. D., Lopes, J. A., Almeida, C. F., Sarraguça, M. C., & Pinheiro, H. M. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6073-9 · Cited by 275
Sensor systems for bioprocess monitoring
Biechele, P., Busse, C., Solle, D., Scheper, T., & Reardon, K. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201500014 · Cited by 224
Claßen, J., Aupert, F., Reardon, K. F., Solle, D., & Scheper, T. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-0068-x · Cited by 176
Optical sensor systems for bioprocess monitoring
Ulber, R., Frerichs, J.-G., & Beutel, S. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-1930-1 · Cited by 151
Fluorescence Spectroscopy and Chemometric Modeling for Bioprocess Monitoring
Faassen, S., & Hitzmann, B. (2015) · Sensors · doi:10.3390/s150510271 · Cited by 120
Research works printed but not linked: 20
- Vaidyanathan S, Macaloney G, Vaughan J, et al. Monitoring of submerged bioprocesses. Crit Rev Biotechnol. 1999;19:277–316. https://doi.org/10.1080/0738-859991229161. · DOI · Paper page
- Kiviharju K, Salonen K, Moilanen U, et al. On-line biomass measurements in bioreactor cultivations: comparison study of two on-line probes. J Ind Microbiol Biotechnol. 2007;34:561–6. https://doi.org/10.1007/s10295-007-0233-5. · DOI · Paper page
- November EJ, Van Impe JF. Evaluation of on-line viable biomass measurements during fermentations of Candida utilis. Bioprocess Eng. 2000;23:473–7. https://doi.org/10.1007/s004499900179. · DOI
- Resa P, Elvira L, De Espinosa FM. Concentration control in alcoholic fermentation processes from ultrasonic velocity measurements. Food Res Int. 2004;37:587–94. https://doi.org/10.1016/j.foodres.2003.12.012. · doi:10.1016/j.foodres.2003.12.012
- Brecker L, Weber H, Griengl H, Ribbons DW. In situ proton-NMR analyses of Escherichia coli HB101 fermentations in 1H2O and in D2O. Microbiology. 1999;145:3389–97. https://doi.org/10.1099/00221287-145-12-3389. · DOI
- Noui L, Hill J, Keay PJ, et al. Development of a high resolution UV spectrophotometer for at-line monitoring of bioprocesses. Chem Eng Process. 2002;41:107–14. https://doi.org/10.1016/S0255-2701(01)00122-2. · DOI
- Ávila TC, Poppi RJ, Lunardi I, et al. Raman spectroscopy and chemometrics for on-line control of glucose fermentation by Saccharomyces cerevisiae. Biotechnol Prog. 2012;28:1598–604. https://doi.org/10.1002/btpr.1615. · DOI · Paper page
- Koch C, Posch AE, Goicoechea HC, et al. Multi-analyte quantification in bioprocesses by Fourier-transform-infrared spectroscopy by partial least squares regression and multivariate curve resolution. Anal Chim Acta. 2014;807:103–10. https://doi.org/10.1016/J.ACA.2013.10.042. · DOI
- Arnold SA, Gaensakoo R, Harvey LM, McNeil B. Use of at-line and in-situ near-infrared spectroscopy to monitor biomass in an industrial fed-batch Escherichia coli process. Biotechnol Bioeng. 2002;80:405–13. https://doi.org/10.1002/bit.10383. · DOI · Paper page
- Ebermann M, Neumann N, Hiller K, et al (2016) Tunable MEMS Fabry-Pérot filters for infrared microspectrometers: a review. In: Piyawattanametha W, Park Y-H (eds). International Society for Optics and Photonics, p 97600H. · DOI
- Antila J, Tuohiniemi M, Rissanen A, et al. MEMS- and MOEMS-based near-infrared spectrometers. In: Encyclopedia of analytical chemistry. Chichester: John Wiley & Sons, Ltd; 2014. p. 1–36.
- Erfan M, Sabry YM, Sakr M, et al. On-chip micro–electro–mechanical system Fourier transform infrared (MEMS FT-IR) spectrometer-based gas sensing. Appl Spectrosc. 2016;70:897–904. https://doi.org/10.1177/0003702816638295. · DOI
- Wiedemair V, Mair D, Held C, Huck CW. Investigations into the use of handheld near-infrared spectrometer and novel semi-automated data analysis for the determination of protein content in different cultivars of Panicum miliaceum L. Talanta. 2019;205:546–53. · DOI
- Kilgus J, Langer G, Duswald K, et al. Diffraction limited mid-infrared reflectance microspectroscopy with a supercontinuum laser. Opt Express. 2018;26:30644. https://doi.org/10.1364/OE.26.030644. · doi:10.1364/oe.26.030644
- Gattinger P, Kilgus J, Zorin I, et al. Broadband near-infrared hyperspectral single pixel imaging for chemical characterization. Opt Express. 2019;27:12666. https://doi.org/10.1364/OE.27.012666. · DOI
- Posch AE, Herwig C. Physiological description of multivariate interdependencies between process parameters, morphology and physiology during fed-batch penicillin production. Biotechnol Prog. 2014;30:689–99. https://doi.org/10.1002/btpr.1901. · DOI
- Luoma P, Golabgir A, Brandstetter M, et al. Workflow for multi-analyte bioprocess monitoring demonstrated on inline NIR spectroscopy of P. chrysogenum fermentation. Anal Bioanal Chem. 2017;409:797–805. https://doi.org/10.1007/s00216-016-9918-9. · DOI
- Burns DA, Ciurczak EW. Handbook of near-infrared analysis: CRC Press; 2008. · DOI · Paper page
- Luoma P, Natschläger T, Malli B, et al. Additive partial least squares for efficient modelling of independent variance sources demonstrated on practical case studies. Anal Chim Acta. 2018;1007:10–5. · doi:10.1016/j.aca.2017.12.027
- Nikzad-Langerodi R, Zellinger W, Lughofer E, Saminger-Platz S. Domain-invariant partial least squares regression. Anal Chem. 2018;90:6693–701. https://doi.org/10.1021/acs.analchem.8b00498. · DOI
Cited by
Sensors and Techniques for On-Line Determination of Cell Viability in Bioprocess Monitoring
Rösner, L., Walter, F., Ude, C., John, G., & Beutel, S. (2022) · Bioengineering · doi:10.3390/bioengineering9120762 · Cited by 42
“Since flow-through cells often do not fulfill the short path length, IR spectra are mostly acquired using spectrometers combined with an immersed fiber-optic probe [82,83].”
MethodMishra, A., Aghaee, M., Tamer, I. M., & Budman, H. (2025) · Spectroscopy Journal · doi:10.3390/spectroscj3020012 · Cited by 19
“A key drawback of MIR is that the background solvent must be transparent within the spectral region of interest [54].”
Metadata
- Authors
- Zimmerleiter, R., Kager, J., Nikzad-Langerodi, R., Berezhinskiy, V., Westad, F., Herwig, C., & Brandstetter, M.
- ORCID
- Brandstetter, Markus
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2019-12-04
- Volume
- 412
- Issue
- 9
- Pages
- 2103-2109
- ISSN
- 1618-2642
- 1618-2650
- Cited by
- 33
- References
- 5
- Language
- en
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Funders
- Österreichische Forschungsförderungsgesellschaft (871974)
- Austrian Competence Centre for Feed and Food Quality, Safety and Innovation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.