Motor unit discharge and force tremor in skill- and strength-trained individuals
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
We examined motor unit (MU) discharge properties (mean interspike interval, ISI, discharge variability, short-term synchronization, common drive) and force tremor in the first dorsal interosseous (FDI) muscle of five musicians (skill-trained), five weight-lifters (strength-trained) and six untrained subjects during low-force isometric abduction of the index finger. Mean MU ISI was slightly shorter in skill-trained subjects than in untrained subjects. Discharge variability of FDI MUs did not differ significantly between groups. The mean strength of MU synchronization (expressed as the frequency of extra synchronous discharges above chance) was different in skill-trained (0.22+/-0.02 s(-1), 162 MU pairs), untrained (0.32+/-0.02 s(-1), 199 MU pairs) and strength-trained subjects (0.44+/-0.03 s(-1), 183 MU pairs). FDI MU synchrony was weak and of equivalent strength in both hands of skill-trained subjects and the dominant (skilled) hand of untrained subjects. The stronger FDI MU synchrony in the non-dominant hand of untrained subjects was equivalent to that found in both hands of strength-trained subjects. The extent of common modulation of firing rates (common drive) was assessed for a subset of MU pairs and was weaker in skill-trained subjects (0.30+/-0.04, n=14) than untrained (0.43+/-0.3, n=14) and strength-trained (0.48+/-0.03, n=21) subjects. Force tremor was quantified for each hand in the same subjects during isometric index finger abduction at target forces of 0.5 N and 3.5 N. Tremor rms amplitude and peak power in the force frequency spectrum were significantly lower in skill-trained subjects than strength-trained subjects with the 3.5-N target force. The peak tremor frequency was similar in the three groups. The relatively more independent discharge of pairs of FDI MUs in skill-trained subjects was not responsible for the reduced tremor amplitudes in these subjects. Correlations between the overall extent of MU synchrony and common drive in FDI muscles and tremor measures obtained during the same experimental session were all non-significant. Differences in the central descending command signals are the most likely explanation for the more independent discharge of FDI MUs in skill-trained hands, while neural or peripheral muscular factors may be responsible for the weaker tremor.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“improvements in rate coding, motor unit recruitment and motor unit synchronisation have been shown to typically occur as a result of high load, or high velocity training [93, 94].”
From Comparison of weightlifting, traditional resistance training and plyometrics on strength, power and speed: a systematic review with meta-analysis. (2022) · cites this paper as [94]
Citations
Cites
The assessment and analysis of handedness: The Edinburgh inventory
Oldfield, R. C. (1971) · Neuropsychologia · doi:10.1016/0028-3932(71)90067-4 · Cited by 35,900 · cited 1×
“The degree of hand dominance was assessed by a 12-point questionnaire (Edinburgh Handedness Inventory; Oldfield 1971).”
MethodCorticospinal Function and Voluntary Movement
Porter, R., & Lemon, R. (1995) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780198523758.001.0001 · Cited by 792 · cited 4×
“The importance of activity in the corticospinal pathway for MU short-term synchrony (Farmer et al. 1990, 1993 a, b; Porter and Lemon 1993; Nordstrom and Semmler 1996) supports the proposal by MilnerBrown et al.”
BackgroundResultInfluentialNoninvasive mapping of muscle representations in human motor cortex
Wassermann, E. M., McShane, L. M., Hallett, M., & Cohen, L. G. (1992) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(92)90094-r · Cited by 593 · cited 2×
“1994), and a larger motor cortical representation (Wassermann et al. 1992).”
BackgroundFarmer, S. F., Bremner, F. D., Halliday, D. M., Rosenberg, J. R., & Stephens, J. A. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019851 · Cited by 514 · cited 5×
“…regression analysis reveals that the extent of MU synchrony and common drive are only weakly related in MU pairs (Semmler et al. 1997), and coherence analysis reveals a weak relationship between MU synchrony and coherence of MU firing rates in the 1- to 12-Hz frequency band (Farmer et al. 1993a).”
BackgroundInfluentialControl scheme governing concurrently active human motor units during voluntary contractions
de Luca, C. J., LeFever, R. S., McCue, M. P., & Xenakis, A. P. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014294 · Cited by 510 · cited 14×
“…synchronization (Sears and Stagg 1976; Datta and Stephens 1990) and common simultaneous fluctuations in mean firing rate (ªcommon driveº; De Luca et al. 1982) are two distinct measures of correlated MU activity that reveal information about the properties of last-order inputs to…”
BackgroundMethodInfluentialThe contractile properties of human motor units during voluntary isometric contractions
Milner‐Brown, H. S., Stein, R. B., & Yemm, R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010087 · Cited by 476 · cited 2×
“Spike-triggered averaging (STA) of twitch forces (Milner-Brown et al. 1973) might provide some evidence that MU mechanical properties are responsible for tremor differences between groups, but interpretation is complicated by the different amounts of MU synchrony in the subject groups, which will introduce systematic…”
BackgroundMethodGalganski, M. E., Fuglevand, A. J., & Enoka, R. M. (1993) · Journal of Neurophysiology · doi:10.1152/jn.1993.69.6.2108 · Cited by 465 · cited 2×
“In human FDI, newly recruited MUs begin firing at between 6±8 Hz (Freund et al. 1975) and this may explain why published force frequency spectra for isometric contractions of FDI have the peak power in this frequency band (Allum et al. 1978; Galganski et al. 1993).”
BackgroundCumulative sum technique and its application to the analysis of peristimulus time histograms
Ellaway, P. H. (1978) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(78)90017-2 · Cited by 451 · cited 1×
“The cumulative sum technique (CUSUM; Ellaway 1978) was used to aid in visually judging the position and duration of the synchronous peak.”
MethodSynchronization of human motor units: Possible roles of exercise and supraspinal reflexes
Milner-Brown, H. S., & Lee, R. G. (1975) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(75)90245-x · Cited by 432 · cited 6×
“Our results are in general agreement with Milner-Brown et al. (1975), who used an indirect method of averaging the surface EMG signal with respect to MU discharge to provide a global estimate of MU synchronization.”
BackgroundMethodResultInfluentialCorticospinal neurons with a special role in precision grip
Muir, R. B., & Lemon, R. N. (1983) · Brain Research · doi:10.1016/0006-8993(83)90635-2 · Cited by 425 · cited 2×
“The degree of corticospinal involvement in muscle activation is flexible depending on the requirements of the task (Muir and Lemon 1983; Datta et al. 1989; Flament et al. 1993), and MU synchrony has also been shown to be task-dependent (Bremner et al.”
Background
Cited by
Spinal and Supraspinal Factors in Human Muscle Fatigue
Gandevia, S. C. (2001) · Physiological Reviews · doi:10.1152/physrev.2001.81.4.1725 · Cited by 3,645
Folland, J. P., & Williams, A. G. (2007) · Sports Medicine · doi:10.2165/00007256-200737020-00004 · Cited by 1,347
The importance of muscular strength: Training considerations
Suchomel, T. J., Nimphius, S., Bellon, C. R., & Stone, M. H. (2018) · Sports Medicine · doi:10.1007/s40279-018-0862-z · Cited by 940
“Previous research indicated that 6 weeks of RT increased MU synchronization [54], while another study indicated that MU synchronization strength was larger in both the dominant and nondominant hands of weightlifters compared to musicians and untrained individuals [55].”
Cormie, P., McGuigan, M. R., & Newton, R. U. (2011) · Sports Medicine · doi:10.2165/11538500-000000000-00000 · Cited by 808
Neural Adaptations to Resistive Exercise: Mechanisms and Recommendations for Training Practices
Gabriel, D. A., Kamen, G., & Frost, G. (2006) · Sports Medicine · doi:10.2165/00007256-200636020-00004 · Cited by 794
“[53] Semmler and Nordstrom [54] ob-als [65-69] as well as training studies to monitor the served differences in motor unit synchronisation actual adaptation.”
BackgroundDeveloping Maximal Neuromuscular Power: Part 1 – Biological Basis of Maximal Power Production
Cormie, P., McGuigan, M. R., & Newton, R. U. (2011) · Sports Medicine · doi:10.2165/11537690-000000000-00000 · Cited by 774
“This observation was corroborated by Semmler and Nordstrom[227] who, using techniques that measured motor unit discharges directly, demonstrated motor unit synchronization to be significantly greater in strength-trained subjects than both musicians and untrained subjects.”
ResultInfluentialSources of Signal-Dependent Noise During Isometric Force Production
Jones, K. E., Hamilton, A. F. D. C., & Wolpert, D. M. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.88.3.1533 · Cited by 562
“The variability in continuous isometric force production is thought to arise from the statistical variability and synchrony in the discharge of motoneurons supplying the muscle (Laidlaw et al. 2000; Semmler and Nordstrom 1998; Semmler et al. 2001; Yao et al. 2000).”
BackgroundContralateral effects of unilateral strength training: evidence and possible mechanisms
Carroll, T. J., Herbert, R. D., Munn, J., Lee, M., & Gandevia, S. C. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00531.2006 · Cited by 499
“There is also evidence that strength training can increase peak firing rates and increase the occurrence of doublets at onset of contraction (84), and it may also alter motor unit synchronization (57, 72, 89).”
BackgroundYao, W., Fuglevand, R. J., & Enoka, R. M. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.1.441 · Cited by 473
“…by such factors as the task that is examined, the motor units and muscles involved in the task, and the type of habitual physical activity performed by the individual (Bremner et al. 1991; Huesler et al. 1998; Schmied et al. 1994, 1998; Semmler and Nordstrom 1995, 1998; Sturm et al. 1997).”
BackgroundInfluentialMoritz, C. T., Barry, B. K., Pascoe, M. A., & Enoka, R. M. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01122.2004 · Cited by 429
Imaging Brain Plasticity: Conceptual and Methodological Issues— A Theoretical Review
Poldrack, R. A. (2000) · NeuroImage · doi:10.1006/nimg.2000.0596 · Cited by 409
“Other studies have demonstrated changes in synchronization related to motor skill acquisition (Andres et al., 1999; Semmler and Nordstrom, 1998 ).”
BackgroundHeckman, C. J., & Enoka, R. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100087 · Cited by 414
Motor unit physiology: Some unresolved issues
Enoka, R. M., & Fuglevand, A. J. (2001) · Muscle & Nerve · doi:10.1002/1097-4598(200101)24:1<4::aid-mus13>3.0.co;2-f · Cited by 390
“Motor unit synchronization is influenced by such factors as learning, handedness, and recovery from a lesion.(56,132,134,138,139) It now appears that synchronization is greater during anisometric contractions compared with isometric contractions, and may be greatest during lengthening contractions.”
BackgroundHigh-yield decomposition of surface EMG signals
Nawab, S. H., Chang, S.-S., & De Luca, C. J. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.11.092 · Cited by 370
“Later recruited motor units tend to have greater variance in inter-pulse interval than earlier recruited motor units, as reported by Tracy et al. (2005) and Contessa et al.”
Training adaptations in the behavior of human motor units
Duchateau, J., Semmler, J. G., & Enoka, R. M. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00543.2006 · Cited by 354
Self-citationNeural Adaptations to Resistance Training: Implications for Movement Control
Carroll, T. J., Riek, S., & Carson, R. G. (2001) · Sports Medicine · doi:10.2165/00007256-200131120-00001 · Cited by 326
“Yue G, Fuglevand AJ, Nordstrom MA, et al. Limitations of the surface electromyography technique for estimating motor unit synchronization.”
BackgroundInfluentialThe potential neural mechanisms of acute indirect vibration.
Cochrane, D. J. (2011) · Europe PMC (PubMed Central) · Cited by 369
The scaling of motor noise with muscle strength and motor unit number in humans
de C. Hamilton, A. F., Jones, K. E., & Wolpert, D. M. (2004) · Experimental Brain Research · doi:10.1007/s00221-004-1856-7 · Cited by 287
“Within the adult, manipulations such as exercise should not be expected to alter the level of noise in a muscle (Keen et al. 1994; Semmler and Nordstrom 1998).”
BackgroundMotor Unit Synchronization and Neuromuscular Performance
Semmler, J. G. (2002) · Exercise and Sport Sciences Reviews · doi:10.1097/00003677-200201000-00003 · Cited by 269
“For example, Semmler and Nordstrom (12) examined 12 Exercise and Sport Sciences Reviews www.acsm-essr.org the effect of habitual physical activity on the association between motor unit synchronization and physiological tremor in the first dorsal interosseus muscle.”
MethodSelf-citationDel Balso, C., & Cafarelli, E. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00477.2006 · Cited by 252
Rodríguez‐Rosell, D., Pareja‐Blanco, F., Aagaard, P., & González‐Badillo, J. J. (2018) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12495 · Cited by 216
“Supporting this notion, previous studies (Milner-Brown et al., 1975; Semmler & Nordstrom, 1998; Semmler, 2002; Folland & Williams, 2007) have reported increased MU synchronization in strength athletes compared to endurance athletes or untrained individuals, which has been accompanied by similar…”
ResultNeural Adaptation to Strength Training
Sale, D. G. (2003) · Strength and Power in Sport · doi:10.1002/9780470757215.ch15 · Cited by 234
Impact of sensorimotor training on the rate of force development and neural activation
Gruber, M., & Gollhofer, A. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1080-y · Cited by 227
“Based on single motor unit recordings, motor unit synchronization has been considered a potential mechanism to modulate force development (Milner-Brown et al. 1975; Semmler and Nordstrom 1998).”
BackgroundLoad-Independent Contributions From Motor-Unit Synchronization to Human Physiological Tremor
Halliday, D. M., Conway, B. A., Farmer, S. F., & Rosenberg, J. R. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.82.2.664 · Cited by 224
“These studies have led to the consensus view that, under normal conditions, motor-unit synchronization does not contribute to physiological tremor (Allum et al. 1978; Dietz et al. 1976; Freund 1983; Logigian et al. 1988; Semmler and Nordstrom 1995, 1998).”
BackgroundMethodCrewther, B. T., Cook, C., Cardinale, M., Weatherby, R. P., & Lowe, T. (2011) · Sports Medicine · doi:10.2165/11539170-000000000-00000 · Cited by 199
Principles of Motor Unit Physiology Evolve With Advances in Technology
Farina, D., Negro, F., Muceli, S., & Enoka, R. M. (2016) · Physiology · doi:10.1152/physiol.00040.2015 · Cited by 212
Carroll, T. J., Selvanayagam, V. S., Riek, S., & Semmler, J. G. (2011) · Acta Physiologica · doi:10.1111/j.1748-1716.2011.02271.x · Cited by 166
“(2 0 0 2 ) P la n ta r fl ex o rs 1 4 tr a in ed (6 5 – 8 5 y ea rs ) H -r efl ex , re st 1 6 w ee k s 4 8 se ss io n s D yn a m ic 5 0 – 8 0 % 1 R M 1 se t o f 1 0 › 1 8 % M V C › 2 4 % 1 R M M H -r efl ex M a ffi u le tt i et al .”
BackgroundSelf-citationCommon Drive in Motor Units of a Synergistic Muscle Pair
De Luca, C. J., & Erim, Z. (2002) · Journal of Neurophysiology · doi:10.1152/jn.00793.2001 · Cited by 173
“…(Adam et al. 1998; Kamen et al. 1992; Semmler and Nordstrom 1995), different proprioceptive conditions (Garland and Miles 1997), exercise (Semmler and Nordstrom 1997), task and disease (Patten et al. 2000), and aging (Erim et al. 1999) on common drive have been studied, the commonality…”
BackgroundChanges in corticospinal drive to spinal motoneurones following visuo‐motor skill learning in humans
Perez, M. A., Lundbye‐Jensen, J., & Nielsen, J. B. (2006) · The Journal of Physiology · doi:10.1113/jphysiol.2006.105361 · Cited by 174
“A more independent discharge of motor units in the hand muscles of musicians has been observed and suggested to indicate adaptations in the central descending command in these subjects (Semmler & Nordstrom, 1998).”
BackgroundMotor unit control and force fluctuation during fatigue
Contessa, P., Adam, A., & De Luca, C. J. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00035.2009 · Cited by 167
The Consequences of Resistance Training for Movement Control in Older Adults
Barry, B. K., & Carson, R. G. (2004) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/59.7.m730 · Cited by 169
“For example, resistance training has also been associated with increased synchronization in the firing of motor units (46,47), which is likely to decrease the ability to steadily produce force (48).”
Endpoint Force Fluctuations Reveal Flexible Rather Than Synergistic Patterns of Muscle Cooperation
Kutch, J. J., Kuo, A. D., Bloch, A. M., & Rymer, W. Z. (2008) · Journal of Neurophysiology · doi:10.1152/jn.90274.2008 · Cited by 136
“Correlation has been observed across muscles (Bremner et al. 1991a,b) and may vary depending on the training of an individual (Semmler 2002; Semmler and Nordstrom 1998b).”
BackgroundSchubert, M., Beck, S., Taube, W., Amtage, F., Faist, M., & Gruber, M. (2008) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2008.06186.x · Cited by 137
“Semmler and Nordstrom (1998) assumed that an increase in precision and automaticity during training is associated with a shifting of neural activation from higher (e.g. cortical) sites to ‘subordinate’ levels with fewer degrees of freedom.”
BackgroundChristakos, C. N., Papadimitriou, N. A., & Erimaki, S. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00051.2005 · Cited by 145
“…MU hypothesis was used in a variety of more recent studies, including studies of sustained contractions, effects of aging or handedness, and attention demanding tasks, (Galganski et al. 1993; Loscher and Gallasch 1993; Schmied et al. 2000; Semmler and Nordstrom 1995, 1998; Semmler et al. 2000a,b).”
MethodMotor unit synchronisation is enhanced during slow lengthening contractions of a hand muscle
Semmler, J. G., Kornatz, K. W., Dinenno, D. V., Zhou, S., & Enoka, R. M. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2002.026948 · Cited by 135
“For example, motor unit discharge is more synchronised in the hand muscles of weight-lifters compared with control subjects (Milner- Brown et al. 1975; Semmler & Nordstrom, 1998), and is less synchronised in the hand muscles of musicians (Semmler & Nordstrom, 1998).”
BackgroundSelf-citationHand kinematics of piano playing
Furuya, S., Flanders, M., & Soechting, J. F. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00378.2011 · Cited by 139
“However, some studies have reported weaker synchronization of motor unit activity within a single hand muscle for musicians than for nonmusicians (Semmler and Nordstrom 1998; Semmler et al. 2004) and a less pronounced difference in cortical activity associated with the index and ring fingers for…”
Transcranial magnetic stimulation during resistance training of the tibialis anterior muscle
Griffin, L., & CAFARELLI, E. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.05.001 · Cited by 149
“There were no significant differences in M-wave amplitudes or in MEP/M ratios for either of the subject groups across training days. training (Semmler and Nordstrom, 1998) could also increase both the amplitude of the MEP and the surface EMG area (Milner-Brown et al., 1975).”
Are age-related increases in force variability due to decrements in strength?
Sosnoff, J. J., & Newell, K. M. (2006) · Experimental Brain Research · doi:10.1007/s00221-006-0422-x · Cited by 131
“It has also been shown that chronic activity can inXuence the amount of motor unit synchronization (Semmler and Nordstrom 1998).”
BackgroundOpar, D. A., Williams, M. D., Timmins, R. G., Dear, N. M., & SHIELD, A. J. (2012) · The American Journal of Sports Medicine · doi:10.1177/0363546512462809 · Cited by 148
“These studies all have focused on mechanisms to explain improved RTD, including increased neural drive, increased motor unit discharge rates, increased motor unit synchronization, and earlier recruitment of motor units.(11,21,38,44) Whether all of these adaptations occur ‘‘in reverse’’ after HSI remains to be seen; ho…”
BackgroundUshiyama, J., Takahashi, Y., & Ushiba, J. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00869.2009 · Cited by 117
“Indeed, recent studies (53, 54) have demonstrated that the motor unit coherence of the finger muscle was smaller in the dominant than in the nondominant hand and was greater in weightlifters than in untrained subjects, but weaker in musicians.”
Motor-Unit Synchronization Is Not Responsible for Larger Motor-Unit Forces in Old Adults
Semmler, J. G., Steege, J. W., Kornatz, K. W., & Enoka, R. M. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.358 · Cited by 112
Self-citationMotor-Unit Coherence and Its Relation With Synchrony Are Influenced by Training
Semmler, J. G., Sale, M. V., Meyer, F. G., & Nordstrom, M. A. (2004) · Journal of Neurophysiology · doi:10.1152/jn.00316.2004 · Cited by 112
“…and coherence (Farmer et al. 1993a) and reduced motor-unit synchronization is observed in skilled hands during a simple isometric contraction (Semmler and Nordstrom 1998), we expect to see reduced coherence in the hand muscles of skill-trained subjects and increased coherence in the hand…”
BackgroundMethodResultSelf-citationNeuromuscular fatigue during dynamic maximal strength and hypertrophic resistance loadings
Walker, S., Davis, L. A., Avela, J., & Häkkinen, K. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2011.12.009 · Cited by 129
Neural Adaptations with Chronic Activity Patterns in Able-Bodied Humans
Duchateau, J., & Enoka, R. M. (2002) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-200211001-00004 · Cited by 109
“Motor unit discharge, for example, is more synchronized in the hand muscles of weight lifters compared with control subjects,(43,44) increases in the hand muscles of sedentary subjects after strength training,(45) and is less synchronized in the hand muscles of musicians.(44) Such findings are presumed to reflect chan…”
BackgroundBalshaw, T. G., Massey, G. J., Maden-Wilkinson, T. M., Morales-Artacho, A. J., McKeown, A., Appleby, C. L., & Folland, J. P. (2017) · European Journal of Applied Physiology · doi:10.1007/s00421-017-3560-x · Cited by 109
“…of additional motor units (Jones et al. 1989; Folland and Williams 2007) and/or increased motor unit synchronization (Milner-Brown et al. 1975; Semmler and Nordstrom 1998) could also enhance EMG amplitude, although it is unclear if the later can contribute to an increase in contractile force…”
Tracy, B. L., Byrnes, W. C., & Enoka, R. M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00861.2003 · Cited by 103
“Furthermore, the discharge properties of motor units in hand muscles will adapt in response to various interventions (7, 22, 31), whereas the adaptive capacity of motor units in quadriceps femoris appears to be reduced (28, 29).”
Morris, S. J., Oliver, J. L., Pedley, J. S., Haff, G. G., & Lloyd, R. S. (2022) · Sports Medicine · doi:10.1007/s40279-021-01627-2 · Cited by 103
“It is likely that neural mechanisms are primarily responsible for high force outputs [92] and improvements in rate coding, motor unit recruitment and motor unit synchronisation have been shown to typically occur as a result of high load, or high velocity training [93, 94].”
BackgroundHoltermann, A., Roeleveld, K., Vereijken, B., & Ettema, G. J. C. (2007) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0380-9 · Cited by 113
“frequently mentioned neural factor that could contribute to increased strength with resistance training is synchronization of motor unit discharges (Behm and Sale 1993b; Enoka 1997; Semmler and Nordstrom 1998).”
BackgroundMaximal motor unit firing rates during isometric resistance training in men.
Pucci, A. R., Griffin, L., & Cafarelli, E. (2006) · Experimental Physiology · doi:10.1113/expphysiol.2005.032094 · Cited by 95
“Such adaptations include changes in the control of the synergistic muscles (Rutherford & Jones, 1986) and motor unit firing rate synchronization (Semmler & Nordstrom, 1998).”
BackgroundPhysiology of the motor neuron and the motor unit
Heckman, C. J., & Enoka, R. M. (2004) · Handbook of clinical neurophysiology · doi:10.1016/s1567-4231(04)04006-7 · Cited by 119
“Although correlated discharges by pairs of motor units appear to enhance the fluctuations in force, this effect can be reduced with physical training (Semmler and Nordstrom, 1998; Taylor et al., 2003).”
BackgroundResistance Training: Cortical, Spinal, and Motor Unit Adaptations
Griffin, L., & CAFARELLI, E. (2005) · Canadian Journal of Applied Physiology · doi:10.1139/h05-125 · Cited by 109
“Motor unit firing rate synchronization is higher in weight lifters than in control subjects (Semmler and Nordstrom, 1998).”
BackgroundKristiansen, M. V., Madeleine, P., Hansen, E. A., & Samani, A. (2013) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.12167 · Cited by 92
“…that neural adaptations such as an increase in neural drive (Häkkinen et al., 2000; Aagaard et al., 2002), motor unit firing rate (Patten et al., 2001; Kamen & Knight, 2004), and motor unit synchronization (Semmler & Nordstrom, 1998) play a role in the force gain following resistance training.”
BackgroundMochizuki, G., Semmler, J. G., Ivanova, T. D., & Garland, S. J. (2006) · Experimental Brain Research · doi:10.1007/s00221-006-0575-7 · Cited by 93
“…surprising considering that in bilateral soleus motor unit pairs, the incidence and strength of motor unit synchrony is low (Mochizuki et al. 2005) and that the strength of synchrony in unilateral soleus motor unit pairs is lower than what has been reported for the FDI (Semmler and Nordstrom 1998).”
BackgroundMethodResultSelf-citationBrouwer, B. J., Sale, M. V., & Nordstrom, M. A. (2001) · Experimental Brain Research · doi:10.1007/s002210100730 · Cited by 83
“Several studies using less direct estimates of corticospinal activity have suggested that strength training may enhance corticospinal involvement in the voluntary drive to FDI (Milner-Brown et al. 1975; Semmler and Nordstrom 1998b ).”
BackgroundResultSelf-citationCastronovo, A. M., Mrachacz‐Kersting, N., Stevenson, A. J. T., Holobar, A., Enoka, R. M., & Farina, D. (2018) · Journal of Neurophysiology · doi:10.1152/jn.00093.2018 · Cited by 82
Neuronal network coherent with hand kinematics during fast repetitive hand movements
Bourguignon, M., Jousmäki, V., Beeck, M. O. D., Bogaert, P. V., Goldman, S., & Tiège, X. D. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.022 · Cited by 78
Holtermann, A., Grönlund, C., Karlsson, J. S., & Roeleveld, K. (2008) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2007.08.008 · Cited by 75
Neuromuscular Adaptations to Isoload versus Isokinetic Eccentric Resistance Training
Guilhem, G., Cornu, C., Maffiuletti, N. A., & Guével, A. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31826e7066 · Cited by 99
“Alternative hypotheses have been suggested to marginally influence EMG amplitude such as the summation of action potentials or the synchronization of activated motor units (10), which have been shown to increase after resistance training (37).”
BackgroundInfluence of proprioceptive feedback on the firing rate and recruitment of motoneurons
Luca, C. J. D., & Kline, J. C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016007 · Cited by 76
Neural adaptations after 4 years vs 12 weeks of resistance training vs untrained
Balshaw, T. G., Massey, G. J., Maden‐Wilkinson, T. M., Lanza, M. B., & Folland, J. P. (2019) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.13331 · Cited by 70
Rearick, M. P., & Santello, M. (2002) · Experimental Brain Research · doi:10.1007/s00221-002-1024-x · Cited by 70
Selective enhancement of motoneurone short-term synchrony during an attention-demanding task
Schmied, A., Pagni, S., Sturm, H., & Vedel, J. (2000) · Experimental Brain Research · doi:10.1007/s002210000421 · Cited by 69
Motor Unit Syncronization Is Reduced in Anterior Knee Pain
Mellor, R., & Hodges, P. W. (2005) · Journal of Pain · doi:10.1016/j.jpain.2005.03.006 · Cited by 75
Motor unit synchronization in young and elderly adults
Kamen, G., & Roy, A. (2000) · European Journal of Applied Physiology · doi:10.1007/s004210050061 · Cited by 65
“It should be noted that the 50% MVC force used during the submaximal contractions in this investigation was considerably greater than the protocol typically implemented in previous studies, which usually involved forces of less than 10%MVC (Bremner et al. 1991; Datta et al. 1991; Semmler and Nordstrom 1998).”
BackgroundResultInfluentialCommon Input to Motor Units of Digit Flexors During Multi-Digit Grasping
Winges, S. A., & Santello, M. (2004) · Journal of Neurophysiology · doi:10.1152/jn.00516.2004 · Cited by 64
“2 in Semmler and Nordstrom 1998; our current data).”
BackgroundInfluentialLinear and nonlinear tremor acceleration characteristics in patients with Parkinson's disease
Meigal, A. Y., Rissanen, S. M., Tarvainen, M. P., Georgiadis, S. D., Karjalainen, P. A., Airaksinen, O., & Kankaanpää, M. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/3/395 · Cited by 63
Motor unit synchronization in FDI and biceps brachii muscles of strength-trained males
Fling, B. W., Christie, A. D., & Kamen, G. (2008) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.06.003 · Cited by 67
The effects of training time, sensory loss and pain on human motor learning
Boudreau, S. A., Hennings, K., Svensson, P. J., Sessle, B. J., & Arendt‐Nielsen, L. (2010) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.2010.02103.x · Cited by 67
Kline, J. C., & Luca, C. J. D. (2015) · Journal of Neurophysiology · doi:10.1152/jn.00452.2015 · Cited by 78
“…Winges et al. 2006); 6) in exercise training (Boonstra et al. 2009; Dartnall et al. 2008, 2011; Griffin et al. 2009; Mochizuki et al. 2005; Schmied and Descarreaux 2010); and 7) during muscle fatigue (Boonstra et al. 2008; Grönlund et al. 2009; Holtermann et al. 2009; Semmler and Nordstrom 1998).”
BackgroundSynchronization of Motor Units in Human Soleus Muscle During Standing Postural Tasks
Mochizuki, G., Ivanova, T. D., & Garland, S. J. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01322.2004 · Cited by 55
Reilly, K. T., Nordstrom, M. A., & Schieber, M. H. (2004) · Journal of Neurophysiology · doi:10.1152/jn.00027.2004 · Cited by 55
“Therefore if no significant synchrony peak was apparent in the CUSUM, a standard window of 11 ms width centered at time 0 was used to assess the strength of synchrony for that pair (Semmler and Nordstrom 1998; Semmler et al. 1997, 2000).”
MethodSelf-citationMotor Unit Recruitment and Proprioceptive Feedback Decrease the Common Drive
De Luca, C. J., Gonzalez-Cueto, J. A., Bonato, P., & Adam, A. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90245.2008 · Cited by 52
Dartnall, T. J., Nordstrom, M. A., & Semmler, J. G. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00854.2010 · Cited by 65
Self-citationEffects of fatigue on synergies in a hierarchical system
Singh, T., Zatsiorsky, V. M., & Latash, M. L. (2012) · Human Movement Science · doi:10.1016/j.humov.2012.06.008 · Cited by 51
“The drop in accuracy of force production could get contribution from the fatigue-induced increase in motor unit synchronization (Bigland & Lippold, 1954; Semmler & Nordstrom, 1998).”
BackgroundDartnall, T. J., Rogasch, N. C., Nordstrom, M. A., & Semmler, J. G. (2009) · Journal of Neurophysiology · doi:10.1152/jn.91285.2008 · Cited by 51
Self-citationForce variability during isometric wrist flexion in highly skilled and sedentary individuals
Salonikidis, K., Amiridis, I. G., Oxyzoglou, N., de Villareal, E. S., Zafeiridis, A., & Kellis, E. (2009) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1184-5 · Cited by 49
“…oe ffi ci en t o f v ar ia tio n (% ) 0 1 2 3 4 5 180° C oe ffi ci en t o f v ar ia tio n (% ) 0 1 2 3 4 5 130° C oe ffi ci en t o f v ar ia tio n (% ) 2005; Laidlaw et al. 2000; Moritz et al. 2005; Semmler and Nordstrom 1998; Taylor et al. 2003; Tracy et al. 2005; Vaillancourt and Newell 2003).”
InfluentialTenan, M. S., Marti, C. N., & Griffin, L. (2014) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2014.08.014 · Cited by 48
Mottram, C. J., Christou, E. A., Meyer, F. G., & Enoka, R. M. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00390.2005 · Cited by 48
Neuromuscular responses to exercise investigated through surface EMG
Felici, F. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.08.002 · Cited by 54
Common Input to Motor Units of Intrinsic and Extrinsic Hand Muscles During Two-Digit Object Hold
Winges, S. A., Kornatz, K. W., & Santello, M. (2008) · Journal of Neurophysiology · doi:10.1152/jn.01059.2007 · Cited by 48
EMG recurrence quantifications in dynamic exercise
Liu, Y., Kankaanpaa, M. J., Zbilut, J. P., & Webber, C. L. (2004) · Biological Cybernetics · doi:10.1007/s00422-004-0474-6 · Cited by 48
“1996), tremor (Amjad et al. 1997; Semmler and Nordstrom 1998), and dystonia (Farmer et al.”
BackgroundHow computational technique and spike train properties affect coherence detection
Terry, K., & Griffin, L. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.09.014 · Cited by 47
“Studies have examined the relationship between motor unit synchrony and force steadiness (Semmler and Nordstrom, 1995; Amjad et al., 1997; Santello and Fuglevand, 2004), task performance (Semmler and Nordstrom, 1998; Maier and Hepp-Reymond, 1995a,b), and strength training (Semmler et al., 2004).”
BackgroundAcquisition of individuated finger movements through musical practice
Furuya, S., Nakamura, A., & Nagata, N. (2014) · Neuroscience · doi:10.1016/j.neuroscience.2014.06.031 · Cited by 52
“Some studies have also reported a weaker synchronization of motor unit activity within a single hand muscle (Semmler and Nordstrom, 1998; Semmler et al., 2004) and a less pronounced difference in the cortical activity associated with the index and ring fingers for musicians compared with non-musicians (Slobounov et al.”
Semmler, J. G., & Nordstrom, M. A. (1999) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00069-2 · Cited by 46
Self-citationVecchio, A. D., Falla, D., Felici, F., & Farina, D. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00139.2019 · Cited by 44
“It has been generally assumed that synchronous discharges of motor units would positively impact the rate of force development of a muscle (2, 23, 29, 38, 39).”
BackgroundEffects of 5 Weeks of Bench Press Training on Muscle Synergies: A Randomized Controlled Study
Kristiansen, M. V., Samani, A., Madeleine, P., & Hansen, E. A. (2015) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001282 · Cited by 47
“Intramuscular neural adaptations encompass increases in motor unit firing rate (22,30), motor unit synchronization (35), and neural drive (1,13,39).”
BackgroundHortobágyi, T., Richardson, S. P., Lomarev, M., Shamim, E. A., Meunier, S., Russmann, H., Dang, N., & Hallett, M. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90701.2008 · Cited by 47
Griffin, L., Painter, P. E., Wadhwa, A., & Spirduso, W. W. (2009) · Experimental Brain Research · doi:10.1007/s00221-009-1920-4 · Cited by 42
“Motor unit synchronization ( Semmler and Nordstrom 1998 ) and coherence (Semmler et al. 2004) are lower in skill-trained compared to untrained individuals.”
BackgroundMotor unit synchronization between medial and lateral vasti muscles
Mellor, R., & Hodges, P. W. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.04.004 · Cited by 41
Effect of fatigue on force fluctuations in knee extensors in young adults
Singh, N. B., Arampatzis, A., Duda, G. N., Heller, M. O. W., & Taylor, W. R. (2010) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2010.0091 · Cited by 47
Signal-dependent wavelets for electromyogram classification
Maitrot, A., Lucas, M. F., Doncarli, C., & Farina, D. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344730 · Cited by 45
Divekar, N., & John, L. R. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.07.019 · Cited by 39
Synchronization of low- and high-threshold motor units
DeFreitas, J. M., Beck, T. W., Ye, X., & Stock, M. S. (2013) · Muscle & Nerve · doi:10.1002/mus.23978 · Cited by 38
Physiological tremor (8–12Hz component) in isometric force control
Novak, T. S., & Newell, K. M. (2017) · Neuroscience Letters · doi:10.1016/j.neulet.2017.01.034 · Cited by 38
Kidgell, D. J., Sale, M. V., & Semmler, J. G. (2006) · Experimental Brain Research · doi:10.1007/s00221-006-0724-z · Cited by 38
“Accordingly, we used our original motor unit sample ( Semmler and Nordstrom 1998 ) and found that motor unit coherence was greatest in the weightlifters (at 3–9 and 21–27 Hz) and least in the musicians (at 21– 27 Hz) compared with untrained subjects, with a strong correlation between motor unit synchronization and hig…”
BackgroundMethodInfluentialSelf-citationMohr, M., Nann, M., von Tscharner, V., Eskofier, B. M., & Nigg, B. M. (2015) · PLoS ONE · doi:10.1371/journal.pone.0142048 · Cited by 37
Lowery, M. M., & Erim, Z. (2005) · Journal of Computational Neuroscience · doi:10.1007/s10827-005-0898-6 · Cited by 36
“A reduction in common firing rate fluctuations has been observed under conditions of reduced proprioceptive feedback (Garland and Miles, 1997) and in skill-trained individuals (Semmler and Nordstrom, 1998).”
BackgroundCorticospinal Responses to Motor Training Revealed by Transcranial Magnetic Stimulation
Carroll, T. J., Riek, S. P., & Carson, R. G. (2001) · Exercise and Sport Sciences Reviews · doi:10.1097/00003677-200104000-00003 · Cited by 35
“Semmler and Nordstrom (13) recently used a combination of TMS and transcranial electrical stimulation (TES) to demonstrate that the excitability of the FDI motor cortical area was greater for the nondominant hand than for the dominant hand during contractions of up to 50% maximum voluntary contractions.”
BackgroundMohr, M., Schön, T., von Tscharner, V., & Nigg, B. M. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00566 · Cited by 35
“Furthermore, musicians who require more individual control of finger muscles showed a lower degree of motor unit synchronization within a finger muscle compared to weight lifters who have trained to use their finger muscles in synergy (Semmler and Nordstrom, 1998).”
BackgroundCharacterization of Electromechanical Delay Based on a Biophysical Multi-Scale Skeletal Muscle Model
Schmid, L., Klotz, T., Siebert, T., & Röhrle, O. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01270 · Cited by 36
“This is particularly interesting since neural control strategies like recruitment strength and synchronization can be modified by physical training, although the mechanisms are still under discussion (cf. e.g., Semmler and Nordstrom, 1998; Van Cutsem et al., 1998; Aagaard, 2003).”
Background
Metadata
- Authors
- Semmler, J. G., & Nordstrom, M. A.
- Affiliations
- The University of Adelaide (AU)
- ORCID
- Semmler, J. G.
- Venue
- Experimental Brain Research
- Published
- 1998-02-09
- Volume
- 119
- Issue
- 1
- Pages
- 27-38
- ISSN
- 0014-4819 (ISSN-L)
- 1432-1106
- OpenAlex
- W2062207193
- Cited by
- 237
- References
- 38
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 16 · 2023: 8 · 2022: 6 · 2021: 8 · 2020: 1 · 2019: 9 · 2018: 9 · 2017: 5 · 2016: 7 · 2015: 11 · 2014: 12 · 2013: 13 · 2012: 12
- FWCI
- 6.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Experimental Brain Research (publishedVersion)
- PubMed (publishedVersion)
- Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
- Funders
- University of Adelaide
- Medical Research Council
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Muscle Physiology and Disorders
- Keywords
- motor unit discharge, motor unit synchronization, common drive, interspike intervals, discharge variability, first dorsal interosseous muscle, skills training, resistance training, musicians, weightlifters, handedness
- MeSH terms
- Adolescent, Adult, Female, Humans, Learning, Male, Motor Neurons, Motor Skills, Physical Fitness, Tremor, Weight Lifting, Muscle, Skeletal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.