The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Radiation exposure in X-ray-based imaging techniques used in osteoporosis
Open accessAbstract
Recent advances in medical X-ray imaging have enabled the development of new techniques capable of assessing not only bone quantity but also structure. This article provides (a) a brief review of the current X-ray methods used for quantitative assessment of the skeleton, (b) data on the levels of radiation exposure associated with these methods and (c) information about radiation safety issues. Radiation doses associated with dual-energy X-ray absorptiometry are very low. However, as with any X-ray imaging technique, each particular examination must always be clinically justified. When an examination is justified, the emphasis must be on dose optimisation of imaging protocols. Dose optimisation is more important for paediatric examinations because children are more vulnerable to radiation than adults. Methods based on multi-detector CT (MDCT) are associated with higher radiation doses. New 3D volumetric hip and spine quantitative computed tomography (QCT) techniques and high-resolution MDCT for evaluation of bone structure deliver doses to patients from 1 to 3 mSv. Low-dose protocols are needed to reduce radiation exposure from these methods and minimise associated health risks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
Vertebral fracture assessment using a semiquantitative technique
Genant, H. K., Wu, C. Y., van Kuijk, C., & Nevitt, M. C. (1993) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650080915 · Cited by 3,691
Health Risks from Exposure to Low Levels of Ionizing Radiation:: BEIR VII Phase 2
Earth, D. O. (2006) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,190
Preface, Executive Summary and Glossary
(2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.10.003 · Cited by 2,106
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Mettler, F. A., Huda, W., Yoshizumi, T. T., & Mahesh, M. (2008) · Radiology · doi:10.1148/radiol.2481071451 · Cited by 2,008
Solid Cancer Incidence in Atomic Bomb Survivors: 1958–1998
Preston, D. L., Ron, E., Tokuoka, S., Funamoto, S., Nishi, N., Soda, M., Mabuchi, K., & Kodama, K. (2007) · Radiation Research · doi:10.1667/rr0763.1 · Cited by 1,753
Benefits and costs, an eternal balance
Dixon, A. K. (2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.09.001 · Cited by 1,355
Radiation-Related Cancer Risks at Low Doses among Atomic Bomb Survivors
Pierce, D. A., & Preston, D. L. (2000) · Radiation Research · doi:10.1667/0033-7587(2000)154[0178:rrcral]2.0.co;2 · Cited by 757
Engelke, K., Adams, J. E., Armbrecht, G., Augat, P., Bogado, C. E., Bouxsein, M. L., Felsenberg, D., Ito, M., Prevrhal, S., Hans, D. B., et al. (2008) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2007.12.010 · Cited by 617
Self-citationRecognition of Vertebral Fracture in a Clinical Setting
Gehlbach, S. H., Bigelow, C., Heimisdottir, M., May, S., Walker, M., & Kirkwood, J. R. (2000) · Osteoporosis International · doi:10.1007/s001980070078 · Cited by 415
Nelson, H. D., Helfand, M., Woolf, S. H., & Allan, J. D. (2002) · Annals of Internal Medicine · doi:10.7326/0003-4819-137-6-200209170-00015 · Cited by 295
Pregnancy and medical radiation
Valentin, J. (2000) · Medical Entomology and Zoology · Cited by 282
Comparison of methods for the visual identification of prevalent vertebral fracture in osteoporosis
Jiang, G., Eastell, R., Barrington, N. A., & Ferrar, L. (2004) · Osteoporosis International · doi:10.1007/s00198-004-1626-1 · Cited by 278
Managing patient dose in Multi-Detector Computed Tomography (MDCT)
Valentin, J. (2007) · Cited by 275
Radiation exposure in bone mineral density assessment
Njeh, C. F., Fuerst, T., Hans, D., Blake, G. M., & Genant, H. K. (1999) · Applied Radiation and Isotopes · doi:10.1016/s0969-8043(98)00026-8 · Cited by 274
Multi-Detector Row CT Imaging of Vertebral Microstructure for Evaluation of Fracture Risk
Ito, M., Ikeda, K., Nishiguchi, M., Shindo, H., Uetani, M., Hosoi, T., & Orimo, H. (2005) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.050610 · Cited by 231
Effective dose values in bone mineral measurements by photon absorptiometry and computed tomography
Kalender, W. A. (1992) · Osteoporosis International · doi:10.1007/bf01623841 · Cited by 210
Application‐ and patient size‐dependent optimization of x‐ray spectra for CT
Kalender, W. A., Deak, P., Kellermeier, M., van Straten, M., & Vollmar, S. V. (2009) · Medical Physics · doi:10.1118/1.3075901 · Cited by 206
Technical approaches to the optimisation of CT
Kalender, W. A., Buchenau, S., Deak, P., Kellermeier, M., Langner, O., van Straten, M., Vollmar, S., & Wilharm, S. (2008) · Physica Medica · doi:10.1016/j.ejmp.2008.01.012 · Cited by 199
Identification of vertebral fractures: An update
Ferrar, L., Jiang, G., Adams, J., & Eastell, R. (2005) · Osteoporosis International · doi:10.1007/s00198-005-1880-x · Cited by 185
Self-citationFaulkner, R. A., Bailey, D. A., Drinkwater, D. T., Wilkinson, A. A., Houston, C. S., & McKay, H. A. (1993) · Calcified Tissue International · doi:10.1007/bf01352007 · Cited by 179
Patient dose in dual x-ray absorptiometry
Lewis, M. K., Blake, G. M., & Fogelman, I. (1994) · Osteoporosis International · doi:10.1007/bf02352255 · Cited by 170
Graeff, C., Timm, W., Nickelsen, T. N., Farrerons, J., Marín, F., Barker, C., & Glüer, C. C. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.070603 · Cited by 159
Comparison of effective dose to children and adults from dual X-ray absorptiometry examinations
Blake, G. M., Naeem, M., & Boutros, M. (2005) · Bone · doi:10.1016/j.bone.2005.11.007 · Cited by 154
Vertebral Fracture Assessment: The 2005 ISCD Official Positions
Vokes, T., Bachman, D. M., Baim, S., Binkley, N., Broy, S. B., Ferrar, L., Lewiecki, E. M., Richmond, B. J., & Schousboe, J. T. (2006) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2006.05.006 · Cited by 151
Longitudinal Trends in Use of Bone Mass Measurement Among Older Americans, 1999–2005
Curtis, J. R., Carbone, L. D., Cheng, H. M., Hayes, B. L., Laster, A. J., Matthews, R., Saag, K. G., Sepanski, R. J., Tanner, S. B., & Delzell, E. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080232 · Cited by 135
Tzedakis, A., Damilakis, J. E., Perisinakis, K., Stratakis, J., & Gourtsoyiannis, N. (2005) · Medical Physics · doi:10.1118/1.1924309 · Cited by 134
Self-citationEngelke, K., Libanati, C. R., Liu, Y., Wang, H., Austin, M., Fuerst, T. P., Stampa, B., Timm, W., & Genant, H. K. (2009) · Bone · doi:10.1016/j.bone.2009.03.669 · Cited by 131
Radiographic methods for evaluating osteoporotic vertebral fractures
Grados, F., Fechtenbaum, J., Flipon, E., Kolta, S., Roux, C., & Fardellone, P. (2009) · Joint Bone Spine · doi:10.1016/j.jbspin.2008.07.017 · Cited by 124
Borggrefe, J., Graeff, C., Nickélsen, T., Marín, F., & Glüer, C. (2009) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.090820 · Cited by 121
Bacchetta, J., Boutroy, S., Vilayphiou, N., Juillard, L., Guebre‐Egziabher, F., Rognant, N., Sornay‐Rendu, E., Szulc, P., Laville, M., Delmas, P. D., et al. (2009) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.090831 · Cited by 120
Vertebral morphometry: current methods and recent advances
Guglielmi, G., Diacinti, D., van Kuijk, C., Aparisi, F., Krestan, C. R., Adams, J. E., & Link, T. M. (2008) · European Radiology · doi:10.1007/s00330-008-0899-8 · Cited by 120
Self-citationPapadakis, A. E., Perisinakis, K., & Damilakis, J. E. (2008) · Medical Physics · doi:10.1118/1.2977535 · Cited by 95
Self-citationNjeh, C. F., Samat, S., Nightingale, A., McNeil, E. A., & Boivin, C. M. (1997) · British Journal of Radiology · doi:10.1259/bjr.70.835.9245884 · Cited by 70
Vertebral morphometry studies using dual-energy X-ray absorptiometry
Blake, G. M., Rea, J. A., & Fogelman, I. (1997) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(97)80029-3 · Cited by 69
Issever, A. S., Link, T. M., Kentenich, M., Rogalla, P., Burghardt, A. J., Kazakia, G. J., Majumdar, S., & Diederichs, G. (2009) · European Radiology · doi:10.1007/s00330-009-1571-7 · Cited by 67
Self-citationDetection of osteoporotic vertebral fractures using multidetector CT
Bauer, J. S., Müller, D., Ambekar, A., Dobritz, M., Matsuura, M., Eckstein, F., Rummeny, E. J., & Link, T. M. (2006) · Osteoporosis International · doi:10.1007/s00198-005-0023-8 · Cited by 66
Self-citationPatient doses in bone mineral densitometry
Huda, W., & Morin, R. L. (1996) · British Journal of Radiology · doi:10.1259/0007-1285-69-821-422 · Cited by 55
Embryo/Fetus Radiation Dose and Risk from Dual X-ray Absorptiometry Examinations
Damilakis, J. E., Perisinakis, K., VRAHORITI, H., Kontakis, G. M., Varveris, H., & Gourtsoyiannis, N. (2002) · Osteoporosis International · doi:10.1007/s001980200098 · Cited by 49
Self-citationKrebs, A., Graeff, C., Frieling, I., Kurz, B., Timm, W., Engelke, K., & Glüer, C. (2008) · Bone · doi:10.1016/j.bone.2008.08.131 · Cited by 41
Guglielmi, G., Palmieri, F., Placentino, M. G., d’Errico, F., & Stoppino, L. P. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2007.12.001 · Cited by 40
Self-citationAbsorbed dose measurements in dual energy X-ray absorptiometry (DXA).
Bezakova, E., Collins, P., & Beddoe, A. H. (1997) · British Journal of Radiology · doi:10.1259/bjr.70.830.9135444 · Cited by 39
Optimized interpretation and reporting of dual X-ray absorptiometry (DXA) scans.
Lenchik, L., Rochmis, P. G., & Sartoris, D. J. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.171.6.9843281 · Cited by 35
Steel, S. A., Baker, A. J., & Saunderson, J. R. (1998) · Physiological Measurement · doi:10.1088/0967-3334/19/1/002 · Cited by 32
Cawte, S. A., Pearson, D., Green, D. J., Maslanka, W., Miller, C. G., & Rogers, A. (1999) · British Journal of Radiology · doi:10.1259/bjr.72.856.10474496 · Cited by 29
The DXL Calscan heel densitometer: evaluation and diagnostic thresholds
Thorpe, J. A., & Steel, S. A. (2006) · British Journal of Radiology · doi:10.1259/bjr/22191429 · Cited by 20
QA/acceptance testing of DEXA X-ray systems used in bone mineral densitometry
Larkin, A. M., Sheahan, N. F., O’Connor, U., Gray, L. H., Dowling, A., Vano, E., Torbica, P., Šalát, D., Schreiner, A., Neofotistou, V., et al. (2008) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncn086 · Cited by 19
Cited by
Pitfalls in the measurement of muscle mass: A need for a reference standard
Buckinx, F., Landi, F., Cesari, M., Fielding, R. A., Visser, M., Engelke, K., Maggi, S., Dennison, E., Al‐Daghri, N. M., Allepaerts, S., et al. (2018) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1002/jcsm.12268 · Cited by 765
Osteoporosis Imaging: State of the Art and Advanced Imaging
Link, T. M. (2012) · Radiology · doi:10.1148/radiol.12110462 · Cited by 453
Self-citationMeasurement of muscle mass in sarcopenia: from imaging to biochemical markers
Tosato, M., Marzetti, E., Cesari, M., Savera, G., Miller, R. R., Bernabei, R., Landi, F., & Calvani, R. (2017) · Aging Clinical and Experimental Research · doi:10.1007/s40520-016-0717-0 · Cited by 320
High-resolution Computed Tomography for Clinical Imaging of Bone Microarchitecture
Burghardt, A. J., Link, T. M., & Majumdar, S. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-010-1766-x · Cited by 296
Self-citationBody composition with dual energy X-ray absorptiometry: from basics to new tools
Messina, C., Albano, D., Gitto, S., Tofanelli, L., Bazzocchi, A., Ulivieri, F. M., Guglielmi, G., & Sconfienza, L. M. (2020) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims.2020.03.02 · Cited by 269
Self-citation
Metadata
- Authors
- Damilakis, J., Adams, J. E., Guglielmi, G., & Link, T. M.
- Venue
- European Radiology
- Published
- 2010-06-18
- Volume
- 20
- Issue
- 11
- Pages
- 2707-2714
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2075079623
- Cited by
- 356
- References
- 48
- FWCI
- 11.09
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.