Radiation exposure in X-ray-based imaging techniques used in osteoporosis
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Recent advances in medical X-ray imaging have enabled the development of new techniques capable of assessing not only bone quantity but also structure. This article provides (a) a brief review of the current X-ray methods used for quantitative assessment of the skeleton, (b) data on the levels of radiation exposure associated with these methods and (c) information about radiation safety issues. Radiation doses associated with dual-energy X-ray absorptiometry are very low. However, as with any X-ray imaging technique, each particular examination must always be clinically justified. When an examination is justified, the emphasis must be on dose optimisation of imaging protocols. Dose optimisation is more important for paediatric examinations because children are more vulnerable to radiation than adults. Methods based on multi-detector CT (MDCT) are associated with higher radiation doses. New 3D volumetric hip and spine quantitative computed tomography (QCT) techniques and high-resolution MDCT for evaluation of bone structure deliver doses to patients from 1 to 3 mSv. Low-dose protocols are needed to reduce radiation exposure from these methods and minimise associated health risks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
Vertebral fracture assessment using a semiquantitative technique
Genant, H. K., Wu, C. Y., van Kuijk, C., & Nevitt, M. C. (1993) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650080915 · Cited by 3,691
Health Risks from Exposure to Low Levels of Ionizing Radiation:: BEIR VII Phase 2
Earth, D. O. (2006) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,190
Preface, Executive Summary and Glossary
(2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.10.003 · Cited by 2,106
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Mettler, F. A., Huda, W., Yoshizumi, T. T., & Mahesh, M. (2008) · Radiology · doi:10.1148/radiol.2481071451 · Cited by 2,008
Solid Cancer Incidence in Atomic Bomb Survivors: 1958–1998
Preston, D. L., Ron, E., Tokuoka, S., Funamoto, S., Nishi, N., Soda, M., Mabuchi, K., & Kodama, K. (2007) · Radiation Research · doi:10.1667/rr0763.1 · Cited by 1,753
Benefits and costs, an eternal balance
Dixon, A. K. (2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.09.001 · Cited by 1,355
Radiation-Related Cancer Risks at Low Doses among Atomic Bomb Survivors
Pierce, D. A., & Preston, D. L. (2000) · Radiation Research · doi:10.1667/0033-7587(2000)154[0178:rrcral]2.0.co;2 · Cited by 757
Engelke, K., Adams, J. E., Armbrecht, G., Augat, P., Bogado, C. E., Bouxsein, M. L., Felsenberg, D., Ito, M., Prevrhal, S., Hans, D. B., et al. (2008) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2007.12.010 · Cited by 617 · cited 2×
“Using MDCT, 3D volume sets are acquired and from these BMD values and bone geometry can be measured [ 9 , 10].”
BackgroundMethodInfluentialSelf-citation
Cited by
Pitfalls in the measurement of muscle mass: A need for a reference standard
Buckinx, F., Landi, F., Cesari, M., Fielding, R. A., Visser, M., Engelke, K., Maggi, S., Dennison, E., Al‐Daghri, N. M., Allepaerts, S., et al. (2018) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1002/jcsm.12268 · Cited by 765
“calibration study is necessary when comparing in vivo results across manufacturers’.(41)”
Osteoporosis Imaging: State of the Art and Advanced Imaging
Link, T. M. (2012) · Radiology · doi:10.1148/radiol.12110462 · Cited by 453
Self-citationMeasurement of muscle mass in sarcopenia: from imaging to biochemical markers
Tosato, M., Marzetti, E., Cesari, M., Savera, G., Miller, R. R., Bernabei, R., Landi, F., & Calvani, R. (2017) · Aging Clinical and Experimental Research · doi:10.1007/s40520-016-0717-0 · Cited by 320
High-resolution Computed Tomography for Clinical Imaging of Bone Microarchitecture
Burghardt, A. J., Link, T. M., & Majumdar, S. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-010-1766-x · Cited by 296
Self-citationBody composition with dual energy X-ray absorptiometry: from basics to new tools
Messina, C., Albano, D., Gitto, S., Tofanelli, L., Bazzocchi, A., Ulivieri, F. M., Guglielmi, G., & Sconfienza, L. M. (2020) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims.2020.03.02 · Cited by 269
Self-citationAutomatic detection of COVID-19 infection using chest X-ray images through transfer learning
Ohata, E. F., Bezerra, G. M., Chagas, J. V. S. D., Lira Neto, A. V., Albuquerque, A. B., Albuquerque, V. H. C. D., & Reboucas Filho, P. P. (2021) · IEEE/CAA Journal of Automatica Sinica · doi:10.1109/jas.2020.1003393 · Cited by 265
Dual-Energy CT for the Musculoskeletal System
Mallinson, P. I., Coupal, T. M., McLaughlin, P. D., Nicolaou, S., Munk, P. L., & Ouellette, H. A. (2016) · Radiology · doi:10.1148/radiol.2016151109 · Cited by 242
Obesity: A preventable, treatable, but relapsing disease
De Lorenzo, A., Romano, L., Di Renzo, L., Di Lorenzo, N., Cenname, G., & Gualtieri, P. (2020) · Nutrition · doi:10.1016/j.nut.2019.110615 · Cited by 205
Zhang, B., Yu, K., Ning, Z., Wang, K., Dong, Y., Liu, X., Liu, S., Wang, J., Zhu, C., Yu, Q., et al. (2020) · Bone · doi:10.1016/j.bone.2020.115561 · Cited by 187
(2012) · Radiology · doi:10.1148/radiol.2633201203 · Cited by 173
Advances in bone imaging for osteoporosis
Adams, J. E. (2013) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2012.217 · Cited by 165
Self-citationMessina, C., Fusco, S., Gazzotti, S., Albano, D., Bonaccorsi, G., Guglielmi, G., & Bazzocchi, A. (2024) · La radiologia medica · doi:10.1007/s11547-024-01843-6 · Cited by 31
“The effective dose for a whole-body scan is only 4–5 μSv with the newest generation of densitometers, meaning that DXA can be considered a low-dose technique for both patients and operators [49, 50].”
BackgroundInfluentialSelf-citationDXA-equivalent quantification of bone mineral density using dual-layer spectral CT scout scans
Laugerette, A., Schwaiger, B. J., Brown, K., Frerking, L. C., Kopp, F. K., Mei, K., Sellerer, T., Kirschke, J., Baum, T., Gersing, A. S., et al. (2019) · European Radiology · doi:10.1007/s00330-019-6005-6 · Cited by 29
Osteoporosis Imaging in the Geriatric Patient
Heilmeier, U., Youm, J., Torabi, S., & Link, T. M. (2016) · Current Radiology Reports · doi:10.1007/s40134-016-0144-1 · Cited by 21
“However, the effective dose of a lateral radiograph of the lumbar and thoracic spine is approximately 600 lSv [24].”
Self-citationO’Hora, L., Neville, N., Tuffy, J., Craig, A., O’Brien, K., Sugrue, K., McGarry, M., Duggan, B., & Egan, S. (2023) · European Radiology · doi:10.1007/s00330-023-09992-4 · Cited by 8
“Although these doses are considered low and the associated risks from ionising radiation are very small when compared to the benefits [27, 34] there is a dearth of research relating to DXA DRLs.”
BackgroundInfluential
Metadata
- Authors
- Damilakis, J., Adams, J. E., Guglielmi, G., & Link, T. M.
- Venue
- European Radiology
- Published
- 2010-06-18
- Volume
- 20
- Issue
- 11
- Pages
- 2707-2714
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2075079623
- Cited by
- 356
- References
- 48
- FWCI
- 11.09
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.