Lesion detection at seven Tesla in multiple sclerosis using magnetisation prepared 3D-FLAIR and 3D-DIR
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To examine the feasibility and value of 7 T 3D T2-weighted Fluid Attenuated Inversion Recovery (FLAIR) and Double Inversion Recovery (DIR) MR sequences for lesion detection in multiple sclerosis (MS). METHODS: High-resolution 3D-FLAIR and 3D-DIR MR sequences at 7 T were obtained using magnetisation preparation (MP), and compared with 2D-T2-weighted and 3D-T1-weighted sequences in 10 MS patients and five healthy controls. We determined contrast ratios and counted lesions according to anatomical location. RESULTS: MR imaging at 7 T was safe and allowed multi-contrast imaging within clinically acceptable imaging times. Lesion to white matter (WM) and grey matter (GM) contrast ratios were higher in 3D-MP-FLAIR and 3D-MP-DIR compared with 2D-T2 and 3D-T1. Cortical (mixed+intra-cortical) and total lesion counts were 97/592 on 3D-MP-FLAIR and 100/558 on 3D-MP-DIR compared with 84/384 on 2D-T2 and 42/442 on 3D-T1. More juxta-cortical lesions were seen with 3D-MP-FLAIR (205) and 3D-MP-DIR (133) than with 2D-T2 (125) and 3D-T1 (70). Finally, higher numbers of lesions were found for deep WM lesions: 176 for 3D-MP-FLAIR and 196 for 3D-MP-DIR vs. 155 for 2D-T2 and 131 for 3D-T1. CONCLUSIONS: Near isotropic 3D-MP-FLAIR and 3D-MP-DIR allows high quality T2-weighted MR imaging in MS at 7 T, improving (cortical) lesion detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnostic criteria for multiple sclerosis: 2005 revisions to the “McDonald Criteria”
Polman, C. H., Reingold, S. C., Edan, G., Filippi, M., Hartung, H., Kappos, L., Lublin, F. D., Metz, L. M., McFarland, H. F., O'Connor, P. W., et al. (2005) · Annals of Neurology · doi:10.1002/ana.20703 · Cited by 5,017 · cited 1×
“Inclusion criteria were clinically definite MS according to the revised ‘McDonald criteria’ of 2005 [20] and age between 18 and 60 years.”
MethodSelf-citationMultiplicity of cerebrospinal fluid functions: new challenges in health and disease
Johanson, C. E., Duncan, J. A., Klinge, P. M., Brinker, T., Stopa, E. G., & Silverberg, G. D. (2008) · Cerebrospinal Fluid Research · doi:10.1186/1743-8454-5-10 · Cited by 861
Evidence for bulk flow of brain interstitial fluid: significance for physiology and pathology
Abbott, N. J. (2004) · Neurochemistry International · doi:10.1016/j.neuint.2003.11.006 · Cited by 786
A Comparison of 3T and 7T in the Detection of Small Parenchymal Veins Within MS Lesions
Tallantyre, E. C., Morgan, P. S., Dixon, J. E., Al-Radaideh, A., Brookes, M. J., Evangelou, N., & Morris, P. G. (2009) · Investigative Radiology · doi:10.1097/rli.0b013e3181b4c144 · Cited by 164 · cited 1×
“To date, most clinical 7 T studies with MS patients have been confined to the T1w, PDT2w, and T2*w protocols [13–16].”
Background
Cited by
on behalf of the MAGNIMS study group, Rovira, À., Wattjes, M. P., Tintoré, M., Tur, C., Yousry, T. A., Sormani, M. P., De Stefano, N., Filippi, M., Auger, C., et al. (2015) · Nature Reviews Neurology · doi:10.1038/nrneurol.2015.106 · Cited by 423
Self-citationOptimized three‐dimensional fast‐spin‐echo MRI
Mugler, J. P. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24542 · Cited by 376
Distinct lesion morphology at 7-T MRI differentiates neuromyelitis optica from multiple sclerosis
Sinnecker, T., Dörr, J., Pfueller, C. F., Harms, L., Ruprecht, K., Jarius, S., Brück, W., Niendorf, T., Wuerfel, J., & Paul, F. (2012) · Neurology · doi:10.1212/wnl.0b013e3182648bc8 · Cited by 214
Harrison, D. M., Roy, S., Oh, J., Izbudak, I., Pham, D., Courtney, S., Caffo, B., Jones, C. K., van Zijl, P., & Calabresi, P. A. (2015) · JAMA Neurology · doi:10.1001/jamaneurol.2015.1241 · Cited by 196
“01 × 10−3]) and in cognitively impaired vs unimpaired individuals (count: 21 [0-99] vs 13 [1-54]; volume: 3.”
BackgroundKey clinical benefits of neuroimaging at 7 T
Trattnig, S., Springer, E., Bogner, W., Hangel, G., Strasser, B., Dymerska, B., Cardoso, P. L., & Robinson, S. D. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2016.11.031 · Cited by 187
“…have shown new insights into the pathology of the cerebral cortex at 7 T, such as, for example, in cortical lesions in cerebrovascular disease (De Reuck et al., 2014) and Multiple Sclerosis (MS) (Yao et al., 2014), or in malformations of cortical development (MCDs), e.g., in Focal Cortical…”
Metadata
- Authors
- de Graaf, W. L., Zwanenburg, J. J. M., Visser, F., Wattjes, M. P., Pouwels, P. J. W., Geurts, J. J. G., Polman, C. H., Barkhof, F., Luijten, P. R., & Castelijns, J. A.
- Venue
- European Radiology
- Published
- 2011-08-27
- Volume
- 22
- Issue
- 1
- Pages
- 221-231
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2066303428
- Cited by
- 84
- References
- 4
- FWCI
- 6.00
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lesion detection at seven Tesla in multiple sclerosis using magnetisation prepared 3D-FLAIR and 3D-DIR. https://app.cochat.ai/papers/10.1007/s00330-011-2242-z
- The paper
- de Graaf, W. L., Zwanenburg, J. J. M., Visser, F., Wattjes, M. P., Pouwels, P. J. W., Geurts, J. J. G., Polman, C. H., Barkhof, F., Luijten, P. R., & Castelijns, J. A. (2012). Lesion detection at seven Tesla in multiple sclerosis using magnetisation prepared 3D-FLAIR and 3D-DIR. European Radiology. https://doi.org/10.1007/s00330-011-2242-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.