CoChat

Lesion detection at seven Tesla in multiple sclerosis using magnetisation prepared 3D-FLAIR and 3D-DIR

Open access
de Graaf, Wolter L., Zwanenburg, Jaco J. M., Visser, Fredy, Wattjes, Mike P., Pouwels, Petra J. W., Geurts, Jeroen J. G., Polman, Chris H., Barkhof, Frederik, Luijten, Peter R., Castelijns, Jonas A. · 2012 · European Radiology
Cited by 84

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: To examine the feasibility and value of 7 T 3D T2-weighted Fluid Attenuated Inversion Recovery (FLAIR) and Double Inversion Recovery (DIR) MR sequences for lesion detection in multiple sclerosis (MS). METHODS: High-resolution 3D-FLAIR and 3D-DIR MR sequences at 7 T were obtained using magnetisation preparation (MP), and compared with 2D-T2-weighted and 3D-T1-weighted sequences in 10 MS patients and five healthy controls. We determined contrast ratios and counted lesions according to anatomical location. RESULTS: MR imaging at 7 T was safe and allowed multi-contrast imaging within clinically acceptable imaging times. Lesion to white matter (WM) and grey matter (GM) contrast ratios were higher in 3D-MP-FLAIR and 3D-MP-DIR compared with 2D-T2 and 3D-T1. Cortical (mixed+intra-cortical) and total lesion counts were 97/592 on 3D-MP-FLAIR and 100/558 on 3D-MP-DIR compared with 84/384 on 2D-T2 and 42/442 on 3D-T1. More juxta-cortical lesions were seen with 3D-MP-FLAIR (205) and 3D-MP-DIR (133) than with 2D-T2 (125) and 3D-T1 (70). Finally, higher numbers of lesions were found for deep WM lesions: 176 for 3D-MP-FLAIR and 196 for 3D-MP-DIR vs. 155 for 2D-T2 and 131 for 3D-T1. CONCLUSIONS: Near isotropic 3D-MP-FLAIR and 3D-MP-DIR allows high quality T2-weighted MR imaging in MS at 7 T, improving (cortical) lesion detection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00330-011-2242-z

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
de Graaf, W. L., Zwanenburg, J. J. M., Visser, F., Wattjes, M. P., Pouwels, P. J. W., Geurts, J. J. G., Polman, C. H., Barkhof, F., Luijten, P. R., & Castelijns, J. A.
Venue
European Radiology
Published
2011-08-27
Volume
22
Issue
1
Pages
221-231
ISSN
  • 0938-7994 (ISSN-L)
  • 1432-1084
OpenAlex
W2066303428
Cited by
84
References
4
FWCI
6.00
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.