Shear wave elastography for breast masses is highly reproducible
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To evaluate intra- and interobserver reproducibility of shear wave elastography (SWE) for breast masses. METHODS: For intraobserver reproducibility, each observer obtained three consecutive SWE images of 758 masses that were visible on ultrasound. 144 (19%) were malignant. Weighted kappa was used to assess the agreement of qualitative elastographic features; the reliability of quantitative measurements was assessed by intraclass correlation coefficients (ICC). For the interobserver reproducibility, a blinded observer reviewed images and agreement on features was determined. RESULTS: Mean age was 50 years; mean mass size was 13 mm. Qualitatively, SWE images were at least reasonably similar for 666/758 (87.9%). Intraclass correlation for SWE diameter, area and perimeter was almost perfect (ICC ≥ 0.94). Intraobserver reliability for maximum and mean elasticity was almost perfect (ICC = 0.84 and 0.87) and was substantial for the ratio of mass-to-fat elasticity (ICC = 0.77). Interobserver agreement was moderate for SWE homogeneity (κ = 0.57), substantial for qualitative colour assessment of maximum elasticity (κ = 0.66), fair for SWE shape (κ = 0.40), fair for B-mode mass margins (κ = 0.38), and moderate for B-mode mass shape (κ = 0.58), orientation (κ = 0.53) and BI-RADS assessment (κ = 0.59). CONCLUSIONS: SWE is highly reproducible for assessing elastographic features of breast masses within and across observers. SWE interpretation is at least as consistent as that of BI-RADS ultrasound B-mode features. KEY POINTS: • Shear wave ultrasound elastography can measure the stiffness of breast tissue • It provides a qualitatively and quantitatively interpretable colour-coded map of tissue stiffness • Intraobserver reproducibility of SWE is almost perfect while intraobserver reproducibility of SWE proved to be moderate to substantial • The most reproducible SWE features between observers were SWE image homogeneity and maximum elasticity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529786 · Cited by 4,332
Fleiss, J. L., & Cohen, J. (1973) · Educational and Psychological Measurement · doi:10.1177/001316447303300309 · Cited by 3,354
Elastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703
Breast Disease: Clinical Application of US Elastography for Diagnosis
Itoh, A., Ueno, E., Tohno, E., Kamma, H., Takahashi, H., Shiina, T., Yamakawa, M., & Matsumura, T. (2006) · Radiology · doi:10.1148/radiol.2391041676 · Cited by 1,640
Elastography of breast lesions: initial clinical results.
Garra, B. S., Cespedes, E. I., Ophir, J., Spratt, S. R., Zuurbier, R. A., Magnant, C. M., & Pennanen, M. F. (1997) · Radiology · doi:10.1148/radiology.202.1.8988195 · Cited by 940
Berg, W. A., Cosgrove, D. O., Doré, C. J., Schäfer, F. K. W., Svensson, W. E., Hooley, R. J., Ohlinger, R., Mendelson, E. B., Balu-Maestro, C., Locatelli, M., et al. (2012) · Radiology · doi:10.1148/radiol.11110640 · Cited by 845
Self-citationBreast Lesions: Quantitative Elastography with Supersonic Shear Imaging—Preliminary Results
Athanasiou, A., Tardivon, A., Tanter, M., Sigal-Zafrani, B., Bercoff, J., Deffieux, T., Gennisson, J.-L., Fink, M., & Neuenschwander, S. (2010) · Radiology · doi:10.1148/radiol.10090385 · Cited by 519
BI-RADS Lexicon for US and Mammography: Interobserver Variability and Positive Predictive Value
Lazarus, E., Mainiero, M. B., Schepps, B., Koelliker, S. L., & Livingston, L. S. (2006) · Radiology · doi:10.1148/radiol.2392042127 · Cited by 511
Quantitative shear wave ultrasound elastography: initial experience in solid breast masses
Evans, A., Whelehan, P., Thomson, K., McLean, D., Brauer, K., Purdie, C., Jordan, L., Baker, L., & Thompson, A. (2010) · Breast Cancer Research · doi:10.1186/bcr2787 · Cited by 450
Differentiating Benign from Malignant Solid Breast Masses with US Strain Imaging
Burnside, E. S., Hall, T. J., Sommer, A. M., Hesley, G. K., Sisney, G. A., Svensson, W. E., Fine, J. P., Jiang, J., & Hangiandreou, N. J. (2007) · Radiology · doi:10.1148/radiol.2452061805 · Cited by 296
Thomas, A., Fischer, T., Frey, H., Ohlinger, R., Grunwald, S., Blohmer, J. ‐., Winzer, K. ‐., Weber, S., Kristiansen, G., Ebert, B., et al. (2006) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.2823 · Cited by 229
Abdullah, N., Mesurolle, B., El-Khoury, M., & Kao, E. (2009) · Radiology · doi:10.1148/radiol.2523080670 · Cited by 205
Observer variability of Breast Imaging Reporting and Data System (BI-RADS) for breast ultrasound
Lee, H.-J., Kim, E.-K., Kim, M. J., Youk, J. H., Lee, J. Y., Kang, D. R., & Oh, K. K. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2007.04.008 · Cited by 181
Supplemental screening sonography in dense breasts
Berg, W. A. (2004) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2004.04.003 · Cited by 149
Self-citation
Cited by
Ultrasound elastography: Principles and techniques
Gennisson, J.-L., Deffieux, T., Fink, M., & Tanter, M. (2013) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2013.01.022 · Cited by 1,052
Cosgrove, D., Piscaglia, F., Bamber, J., Bojunga, J., Correas, J.-M., Gilja, O., Klauser, A., Sporea, I., Calliada, F., Cantisani, V., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335375 · Cited by 955
Self-citationWFUMB Guidelines and Recommendations for Clinical Use of Ultrasound Elastography: Part 3: Liver
Ferraioli, G., Filice, C., Castera, L., Choi, B. I., Sporea, I., Wilson, S. R., Cosgrove, D., Dietrich, C. F., Amy, D., Bamber, J. C., et al. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.03.007 · Cited by 879
Self-citationWFUMB Guidelines and Recommendations for Clinical Use of Ultrasound Elastography: Part 2: Breast
Barr, R. G., Nakashima, K., Amy, D., Cosgrove, D., Farrokh, A., Schafer, F., Bamber, J. C., Castera, L., Choi, B. I., Chou, Y.-H., et al. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.03.008 · Cited by 474
Self-citationBreast Ultrasonography: State of the Art
Hooley, R. J., Scoutt, L. M., & Philpotts, L. E. (2013) · Radiology · doi:10.1148/radiol.13121606 · Cited by 324
Metadata
- Authors
- the BE1 Study Group, Cosgrove, D. O., Berg, W. A., Doré, C. J., Skyba, D. M., Henry, J.-P., Gay, J., & Cohen-Bacrie, C.
- Venue
- European Radiology
- Published
- 2011-12-31
- Volume
- 22
- Issue
- 5
- Pages
- 1023-1032
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2070897578
- Cited by
- 406
- References
- 14
- FWCI
- 20.68
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.