Validity and reliability of three commercially available breath-by-breath respiratory systems
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validation of the COSMED K4 b2 Portable Metabolic System
McLaughlin, J. E., King, G. A., Howley, E. T., Bassett, Jr., & Ainsworth, B. E. (2001) · International Journal of Sports Medicine · doi:10.1055/s-2001-13816 · Cited by 374 · cited 3×
“1993; Peel and Utsey 1993), the Cosmed K4 metabolic system (McLaughlin et al. 2001) and the Aerosport TEEM 100 portable Eur J Appl Physiol (2002) 86: 435–441 DOI 10.”
BackgroundMethodInfluentialThe Cosmed K4 Telemetry System as an Accurate Device for Oxygen Uptake Measurements during Exercise
Hausswirth, C., Bigard, A., & Le Chevalier, J. (1997) · International Journal of Sports Medicine · doi:10.1055/s-2007-972662 · Cited by 193 · cited 2×
“This consistent discrepancy has been attributed to the K2’s calculation of _VO2, in which it assumes, in the absence of a CO2 electrode, that the RER is always 1.00 (Hausswirth et al. 1997).”
BackgroundInfluentialBiological variability in maximum aerobic power.
KATCH, V. L., SADY, S. S., & FREEDSON, P. (1982) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198201000-00004 · Cited by 187 · cited 2×
“In comparison, the Cosmed K2 telemetry system is consistently found to underestimate _ VO2 during sub-maximal exercise (Kawakami et al. 1992; Lothian et al. 1993; Peel and Utsey 1993). Peel and Utsey (1993) reported a 12.”
MethodInfluentialRietjens, G. J., Kuipers, H., Kester, A. D., & Keizer, H. A. (2001) · International Journal of Sports Medicine · doi:10.1055/s-2001-14342 · Cited by 126 · cited 6×
“These findings are supported by Rietjens et al. (2001), who found no differences for similar respiratory variables throughout an incremental cycle test between the Oxycon Pro and Douglas bag system.”
BackgroundMethodResultInfluentialValidity and Reliability of the Cosmed K2 Instrument
Lucía, A., Fleck, S., Gotshall, R., & Kearney, J. (1993) · International Journal of Sports Medicine · doi:10.1055/s-2007-1021196 · Cited by 95 · cited 2×
“…that does exist concentrates largely upon portable systems, such as the Cosmed K2 telemetry system (Kawakami et al. 1992; Lothian et al. 1993; Lucia et al. 1993; Peel and Utsey 1993), the Cosmed K4 metabolic system (McLaughlin et al. 2001) and the Aerosport TEEM 100 portable J. Carter Æ A.E.…”
MethodDay to Day Variation in Time Trial Cycling Performance
Hickey, M., Costill, D., McConell, G., Widrick, J., & Tanaka, H. (1992) · International Journal of Sports Medicine · doi:10.1055/s-2007-1021299 · Cited by 92 · cited 3×
“Hickey et al. (1992) investigated day-to-day 40-mile time-trial variation and reported the CV for mean _ VO2 as 3.0% and the percent _ VO2max as 3.6%. The values generated for the CV of _ VO2 by our systems (excluding Pulmolab) are slightly higher than these, except for the Douglas bags at 150 W. Jensen and Johansen (…”
MethodResultInfluentialReliability of measurement of oxygen uptake by a portable telemetric system
Kawakami, Y., Nozaki, D., Matsuo, A., & Fukunaga, T. (1992) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00243506 · Cited by 65 · cited 6×
“The literature that does exist concentrates largely upon portable systems, such as the Cosmed K2 telemetry system (Kawakami et al. 1992; Lothian et al. 1993; Lucia et al. 1993; Peel and Utsey 1993), the Cosmed K4 metabolic system (McLaughlin et al. 2001) and the Aerosport TEEM 100 portable Eur J Appl Physiol (2002) 86…”
BackgroundMethodInfluentialAssessment of the Aerosport TEEM 100 Portable Metabolic Measurement System
WIDEMAN, L., STOUDEMIRE, N. M., PASS, K. A., McGINNES, C. L., GAESSER, G. A., & WELTMAN, A. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199604000-00017 · Cited by 56 · cited 2×
“Jeukendrup (&) Human Performance Laboratory, School of Sport and Exercise Sciences, The University of Birmingham, Edgbaston, B15 2TT, Birmingham, UK E-mail: a.e.Jeukendrup@bham.ac.uk Tel.: +44-121-4144124 Fax: +44-121-4144121 metabolic measurement system ( Wideman et al. 1996 ).”
BackgroundVariability of Respiration and Metabolism: Responses to Submaximal Cycling and Running
Armstrong, L. E., & Costill, D. L. (1985) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.1985.10608441 · Cited by 55 · cited 3×
“This is supported by Armstrong and Costill (1985), who reported that the day-to-day variability of _VO2 (4.0”
BackgroundInfluentialOxygen consumption using the K2 telemetry system and a metabolic cart.
Peel, C., & Utsey, C. (1993) · PubMed · Cited by 50
Jensen, K., & Johansen, L. (1998) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/j.1600-0838.1998.tb00221.x · Cited by 36 · cited 5×
“The values generated for the CV of _ V O2 by our systems (excluding Pulmolab) are slightly higher than these, except for the Douglas bags at 150 W. Jensen and Johansen (1998) reported a range of CV values for test-retest parameters over a series of time trials.”
BackgroundMethodResultInfluentialAutomated Systems for Measurement of Oxygen Uptake During Exercise Testing
Versteeg, P. A., & Kippersluis, G. (1989) · International Journal of Sports Medicine · doi:10.1055/s-2007-1024884 · Cited by 29 · cited 3×
“Versteeg and Kippersluis (1989) compared the _ VO2 measured using three automated systems with that”
BackgroundMethodInfluentialVariance of direct and indirect measurements of aerobic power.
Gr, W., Sidney, K., & Rj, S. (1978) · PubMed · Cited by 20
Variability of physiological responses to exercise
Kuipers, H. (1983) · doi:10.26481/dis.19830610hk · Cited by 14
Cited by
Balady, G. J., Arena, R., Sietsema, K., Myers, J., Coke, L., Fletcher, G. F., Forman, D., Franklin, B., Guazzi, M., Gulati, M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181e52e69 · Cited by 1,964
Myers, J., Arena, R., Franklin, B., Pina, I., Kraus, W. E., McInnis, K., & Balady, G. J. (2009) · Circulation · doi:10.1161/circulationaha.109.192520 · Cited by 338
The Role and Development of Sprinting Speed in Soccer
Haugen, T. A., Tønnessen, E., Hisdal, J., & Seiler, S. (2014) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2013-0121 · Cited by 334
Ainslie, P. N., Reilly, T., & Westerterp, K. R. (2003) · Sports Medicine · doi:10.2165/00007256-200333090-00004 · Cited by 309
Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems
Crouter, S. E., Antczak, A., Hudak, J. R., DellaValle, D. M., & Haas, J. D. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0255-0 · Cited by 240
“Carter and Jeukendrup (Carter and Jeukendrup 2002) examined the DB method, Oxycon Alpha metabolic system, Pulmolab, metabolic system, and Oxycon Pro metabolic system for reliability during cycling at 100 and 150 W.”
MethodInfluential
Metadata
- Authors
- Carter, J., & Jeukendrup, A.
- Venue
- European Journal of Applied Physiology
- Published
- 2002-03-01
- Volume
- 86
- Issue
- 5
- Pages
- 435-441
- ISSN
- 0020-9376 (ISSN-L)
- 1439-6319
- 1439-6327
- OpenAlex
- W2055728620
- Cited by
- 169
- References
- 14
- FWCI
- 10.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.