Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · cited 1×
“Additionally, agreement between the instruments was graphically displayed with Bland–Altman plots (Bland and Altman 1999).”
MethodMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635 · cited 3×
“This value (typical error) was then divided with the average of the test–retest values and multiplied by 100 (Hopkins 2000).”
MethodEffect of training on circulatory response to exercise.
Ekblom, B., Astrand, P. O., Saltin, B., Stenberg, J., & Wallström, B. (1968) · Journal of Applied Physiology · doi:10.1152/jappl.1968.24.4.518 · Cited by 522 · cited 2×
“3% with untrained subjects (Ekblom 1970; Ekblom et al. 1968) and 1.”
BackgroundMethodInfluentialValidation of the COSMED K4 b2 Portable Metabolic System
McLaughlin, J. E., King, G. A., Howley, E. T., Bassett, Jr., & Ainsworth, B. E. (2001) · International Journal of Sports Medicine · doi:10.1055/s-2001-13816 · Cited by 374 · cited 11×
“…100 W, and 2.12 L min-1 at 150 W; (Åstrand and Rodahl 1986) as well as with data from other research groups: 1.02 L min-1 at 50 W, 1.58 L min-1 at 100 W and 2.23 L min-1 at 150 W (Bassett et al. 2001); 0.94 L min-1 at 50 W, 1.53 L min-1 at 100 W and 2.14 L min-1 at 150 W (McLaughlin et al. 2001).”
BackgroundMethodResultInfluentialEkblom, B., & Hermansen, L. (1968) · Journal of Applied Physiology · doi:10.1152/jappl.1968.25.5.619 · Cited by 354 · cited 2×
“VO2 max to 2.6 and 3.3% with untrained subjects (Ekblom 1970; Ekblom et al. 1968) and 1.1% with athletes ( Ekblom and Hermansen 1968 ).”
BackgroundMethodInfluentialAccuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems
Crouter, S. E., Antczak, A., Hudak, J. R., DellaValle, D. M., & Haas, J. D. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0255-0 · Cited by 240 · cited 14×
“In accordance with those findings, Crouter et al. (2006) reported no differences during exercise at 50, 100 and 150 W with VO2000, while significant differences (*7% high) were found at 200 and 250 W.”
BackgroundMethodResultInfluentialAutomated Metabolic Gas Analysis Systems: A Review
Macfarlane, D. J. (2001) · Sports Medicine · doi:10.2165/00007256-200131120-00002 · Cited by 198
Validity and reliability of three commercially available breath-by-breath respiratory systems
Carter, J., & Jeukendrup, A. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-001-0572-2 · Cited by 169 · cited 5×
“2003), and in scientific studies (Atkinson et al. 2005; Bassett et al. 2001; Brehm et al. 2004; Carter and Jeukendrup 2002; Crouter et al. 2006; Gore et al. 2003; Hodges et al. 2005; Jensen et al. 2002; Larsson et al. 2004; Macfarlane 2001; McLaughlin et al. 2001; Medbø et al. 2002) the DBM was the criterion method fo…”
BackgroundMethodInfluentialEnergy Cost of Physical Activities in Children: Validation of SenseWear Armband
Arvidsson, D., Slinde, F., Larsson, S., & Hulthén, L. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31814fb439 · Cited by 142 · cited 2×
“Further, the Oxycon Mobile metabolic system has been used as the criterion method to measure energy cost in children ( Arvidsson et al. 2007, 2009 ), despite the limited information available as to its validity and reliability.”
Method
Cited by
Comparison of Accelerometer Cut Points for Predicting Activity Intensity in Youth
TROST, S. G., LOPRINZI, P. D., MOORE, R., & PFEIFFER, K. A. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318206476e · Cited by 1,360
Validation and comparison of ActiGraph activity monitors
Sasaki, J. E., John, D., & Freedson, P. S. (2011) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2011.04.003 · Cited by 1,317
Validity of Consumer-Based Physical Activity Monitors
LEE, J.-M., KIM, Y., & WELK, G. J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000287 · Cited by 401
“Mean differences reported in the study were in all cases less than 5% (18).”
BackgroundLyden, K., Kozey, S. L., Staudenmeyer, J. W., & Freedson, P. S. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1639-8 · Cited by 222
“The Oxycon Mobile system is a valid device for measuring VO2 (Perret and Mueller 2006; Rosdahl et al. 2009).”
InfluentialWalking cadence (steps/min) and intensity in 21–40 year olds: CADENCE-adults
Tudor-Locke, C., Aguiar, E. J., Han, H., Ducharme, S. W., Schuna, J. M., Barreira, T. V., Moore, C. C., Busa, M. A., Lim, J., Sirard, J. R., et al. (2019) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-019-0769-6 · Cited by 205
“Physical Activity Intensity (oxygen consumption; VO2 mL/kg/min) was measured using a validated portable indirect calorimeter (Jaeger Oxycon Mobile; CareFusion BD Germany 234 GmbH, Höchberg, Germany) [16].”
MethodAccelerometer output and MET values of common physical activities
KOZEY, S. L., LYDEN, K., HOWE, C. A., STAUDENMAYER, J. W., & FREEDSON, P. S. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181d479f2 · Cited by 174
“Measured METs (measured V̇O2/measured RMR).”
InfluentialSix‐minute walk test: a tool for predicting maximal aerobic power (VO2 max) in healthy adults
Mänttäri, A., Suni, J., Sievänen, H., Husu, P., Vähä‐Ypyä, H., Valkeinen, H., Tokola, K., & Vasankari, T. (2018) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12525 · Cited by 175
“After health screening, participants were equipped with portable heart rate monitor (Polar T31, Kempele, Finland) and breath-by-breath portable metabolic analyser (Oxycon Mobile, Carefusion, Yorba Linda, CA, USA) (Rosdahl et al., 2010).”
MethodValidity and Reliability of the VO2 Master Pro for Oxygen Consumption and Ventilation Assessment
(2020) · International Journal of Exercise Science · doi:10.70252/thjt1177 · Cited by 39
“8%) (26) and MetaMax (coefficients of variation 5.”
BackgroundAccuracy of Consumer Monitors for Estimating Energy Expenditure and Activity Type
WOODMAN, J. A., CROUTER, S. E., BASSETT, D. R., FITZHUGH, E. C., & BOYER, W. R. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001090 · Cited by 29
“This device has been shown to be valid measuring V̇O2 and V̇CO2 compared with the Douglas Bag method (20) and a laboratorybased metabolic cart (19).”
MethodHerkert, C., Kraal, J. J., van Loon, E. M. A., van Hooff, M., & Kemps, H. M. C. (2019) · JMIR mHealth and uHealth · doi:10.2196/15045 · Cited by 19
Towards an understanding of physical activity in people with chronic low back pain
Griffin, D. W. (2013) · University of Limerick · doi:10.34961/7893 · Cited by 1
Metadata
- Authors
- Rosdahl, H., Gullstrand, L., Salier-Eriksson, J., Johansson, P., & Schantz, P.
- Venue
- European Journal of Applied Physiology
- Published
- 2009-12-31
- Volume
- 109
- Issue
- 2
- Pages
- 159-171
- ISSN
- 0020-9376 (ISSN-L)
- 1439-6319
- 1439-6327
- OpenAlex
- W1965577195
- Cited by
- 181
- References
- 27
- FWCI
- 19.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.