Comparisons of local and systemic aerobic fitness parameters between finswimmers with different athlete grade levels
The DOI matches its Crossref record; 56 of the 57 references it cites were found in a registry or an index.
Abstract
To study the relationship between the local and systemic aerobic fitness parameters, and between the muscle oxygenation and aerobic performance, 16 female finswimmers were recruited and divided into high-level (HL) group and low-level group. Cardiorespiratory function, blood lactate concentration and near infrared spectroscopy muscle oxygenation in the vastus lateralis (VL) were monitored simultaneously during a maximal incremental exercise. We found that the break point (Bp) of the oxygenation index (OI) in the VL (BpVL) had significant correlations with lactate threshold (LT) and gas exchange threshold (GET), and the appearance sequence of the three thresholds was BpVL ≈ LT ≤ GET. When considering different levels, the [Formula: see text] at BpVL, LT and GET were higher in the HL group. During intensive exercise, there were significantly faster [Formula: see text] increase and evidently slower OI decrease in the HL group, suggesting that faster [Formula: see text] increase in the HL group slowed down the muscle deoxygenation and facilitated subjects to cycle to higher workloads. In conclusion, multi-modality approaches combining local and systemic physiological monitoring technologies might provide better explanations of the relationship between local and systemic aerobic fitness parameters, and might be a novel way to analyze the difference between groups of different levels.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“At somewhat lower exercise intensities, a breakpoint in Hb difference ([O2HbMb-HHbMb]) occurs during maximal stepwise incremental exercise and shows high correlations with VT1 and the lactate threshold (r>0.88) [17–19].”
From Oxygenation Threshold Derived from Near-Infrared Spectroscopy: Reliability and Its Relationship with the First Ventilatory Threshold (2016) · cites this paper as [18]
In the citing paper
“These calculations showed that differences in the Δ[O2HbMb-HHbMb]-BP and VT1 could be detected with a sample size of 9 subjects for PO (W) and 4–8 subjects for (L/min) [18,19].”
From Oxygenation Threshold Derived from Near-Infrared Spectroscopy: Reliability and Its Relationship with the First Ventilatory Threshold (2016) · cites this paper as [18]
In the citing paper
“Between-subject variation, in Δ[O2HbMb-HHbMb]-BP was higher than reported in previous studies [17–19], which may be due to a more heterogeneous subject group in the present study.”
From Oxygenation Threshold Derived from Near-Infrared Spectroscopy: Reliability and Its Relationship with the First Ventilatory Threshold (2016) · cites this paper as [18]
Citations
Cites
Faul, F., Erdfelder, E., Lang, A.-G., & Buchner, A. (2007) · Behavior Research Methods · doi:10.3758/bf03193146 · Cited by 65,971 · cited 2×
“1 computer software (Faul et al. 2007) with knowing the three determinants (level of significance, sample size, effect size) of statistical power.”
MethodInfluentialCohen, J. (1992) · Psychological Bulletin · doi:10.1037//0033-2909.112.1.155 · Cited by 8,771
Anaerobic threshold and respiratory gas exchange during exercise.
Wasserman, K., Whipp, B. J., Koyl, S. N., & Beaver, W. L. (1973) · Journal of Applied Physiology · doi:10.1152/jappl.1973.35.2.236 · Cited by 2,094 · cited 4×
“tilatory equivalent method: GET was the break point at which there was an increase in the ventilatory equivalents for oxygen ( _ VE= _ VO2) versus time without a simultaneous increase in the ventilatory equivalents for carbon dioxide ( _ VE= _ VCO2) versus time (Legrand et al. 2007; Wasserman et al. 1973) (Fig.”
BackgroundMethodInfluentialPrinciples, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997 · cited 4×
“In recent years, a noninvasive and portable muscle oxygenation monitoring technology, continuous wave (CW) near infrared spectroscopy (NIRS) (Ferrari et al. 2004; Boushel et al. 2001) has been introduced to the exercise physiology detection and has promoted our understanding of the aerobic…”
BackgroundMethodInfluentialThe Effect of Endurance Training on Parameters of Aerobic Fitness
Jones, A. M., & Carter, H. (2000) · Sports Medicine · doi:10.2165/00007256-200029060-00001 · Cited by 935 · cited 2×
“During an incremental exercise test, cardiorespiratory measurement and blood lactate measurement could be combined to obtain systemic parameters of aerobic fitness such as maximal oxygen uptake ( _ VO2 max), anaerobic thresholds [gas exchange threshold (GET), lactate threshold (LT)] and so on (Baquet et al. 2003; Jone…”
BackgroundMethodProgress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600 · cited 2×
“2001) has been introduced to the exercise physiology detection and has promoted our understanding of the aerobic metabolism in local skeletal muscles (Wolf et al. 2007; Hamaoka et al. 2007; Bhambhani 2004; Boushel et al. 2001; Zhang et al. 2010; Sako et al. 2001).”
BackgroundSullivan, M. J., Knight, J. D., Higginbotham, M. B., & Cobb, F. R. (1989) · Circulation · doi:10.1161/01.cir.80.4.769 · Cited by 519 · cited 2×
“There seems no significant difference in maximal C(a-v)O2 in legs between subjects with different exercise levels (Zhou et al. 2001; Sullivan et al. 1989).”
BackgroundMonitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease
Boushel, R., Langberg, H., Olesen, J., Gonzales‐Alonzo, J., Bülow, J., & Kjær, M. (2001) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2001.110404.x · Cited by 469 · cited 18×
“The light intensity before and after absorption and scattering of tis- sue could be recorded by the CW-NIRS muscle oxygena- tion device.”
BackgroundInfluentialImproved detection of lactate threshold during exercise using a log-log transformation
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.59.6.1936 · Cited by 457 · cited 8×
“The V-slope method (Amann et al. 2004; Beaver et al. 1985) was also used to identify the GET automatically with a computer to confirm the GET identified by the ventilatory equivalent method (Zhang et al.”
MethodInfluentialValidity and reliability of combining three methods to determine ventilatory threshold
GASKILL, S. E., RUBY, B. C., WALKER, A. J., SANCHEZ, O. A., SERFASS, R. C., & LEON, A. S. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200111000-00007 · Cited by 444 · cited 4×
“Though the relationships among the three thresholds have been partly reported (Bhambhani et al. 1997; Zhang et al. 2010; Gaskill et al. 2001; Wang et al. 2009), the appearance sequence of them is still controversial (Zhang et al.”
BackgroundInfluentialBentley, D. J., Newell, J., & Bishop, D. (2007) · Sports Medicine · doi:10.2165/00007256-200737070-00002 · Cited by 404 · cited 4×
“The incre- mental cycling exercise started at an initial workload of 40 W, followed by increments of 30 W every 3 min (Bentley et al. 2007) until volitional fatigue or two of the following criteria (Bhambhani et al. 2001; Zhang et al. 2010) were attained: (1) heart rate (HR) C age-predicted maximal…”
MethodInfluentialIntra- and extra-cellular lactate shuttles
BROOKS, G. A. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200004000-00011 · Cited by 383 · cited 2×
“During mild to moderate exercise intensity, although lactic acid was produced in skeletal muscles at any time even under fully aerobic conditions (Brooks 2000), most of the lactic acid could be reoxidized in the skeletal muscle and in other less active muscles (Gladden 2000).”
BackgroundHamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329 · cited 8×
“2001) has been introduced to the exercise physiology detection and has promoted our understanding of the aerobic metabolism in local skeletal muscles (Wolf et al. 2007; Hamaoka et al. 2007; Bhambhani 2004; Boushel et al. 2001; Zhang et al. 2010; Sako et al. 2001).”
BackgroundMethodInfluentialEvaluation of the Lactate Pro blood lactate analyser
Pyne, D. B., Boston, T., Martin, D. T., & Logan, A. (2000) · European Journal of Applied Physiology · doi:10.1007/s004210050659 · Cited by 313 · cited 2×
“Blood lactate concentration was measured using a portable lactate test meter (Lactate Pro, LT-1710, Arkray, Shiga, Japan) (Pyne et al. 2000; Mc Naughton et al. 2002).”
MethodEndurance Training and Aerobic Fitness in Young People
Baquet, G., Van Praagh, E., & Berthoin, S. (2003) · Sports Medicine · doi:10.2165/00007256-200333150-00004 · Cited by 308 · cited 4×
“Aerobic fitness not only determines performance in a wide range of activities, but it is also a health-related parameter (Baquet et al. 2003).”
BackgroundMethodInfluentialCardiac output estimated noninvasively from oxygen uptake during exercise
Stringer, W. W., Hansen, J. E., & Wasserman, K. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.3.908 · Cited by 282
Blood lactate accumulation and muscle deoxygenation during incremental exercise
Grassi, B., Quaresima, V., Marconi, C., Ferrari, M., & Cerretelli, P. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.1.348 · Cited by 248 · cited 15×
“In previous reports, different types of subjects were recruited to participate in incremental exercise tests, and the changes in muscle oxygenation were analyzed to get the break point (Bp) of muscle deoxygenation (Grassi et al. 1999; Wang et al. 2006; Belardinelli et al. 1995).”
BackgroundMethodResultInfluentialDeterminants and detection of anaerobic threshold and consequences of exercise above it.
Wasserman, K. (1987) · PubMed · Cited by 232
Belardinelli, R., Barstow, T. J., Porszasz, J., & Wasserman, K. (1995) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00634377 · Cited by 213 · cited 4×
“It was reported that there were significant correlations between Bp and lactate threshold (Grassi et al. 1999; Wang et al. 2009), and between Bp and gas exchange threshold (Belardinelli et al. 1995).”
BackgroundMethodInfluentialRatings of perceived exertion at the lactate threshold in trained and untrained men and women
DEMELLO, J. J., CURETON, K. J., BOINEAU, R. E., & SINGH, M. M. (1987) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198708000-00006 · Cited by 189 · cited 6×
“…were greater than those for the LL group, consistent with the significant difference in WRmax, _VO2 max between welltrained and less-trained groups (Demello et al. 1987; Boone et al. 2009; Hug et al. 2004), suggesting better aerobic fitness for the HL group, which might account for their better…”
BackgroundResultInfluentialLactic acidosis as a facilitator of oxyhemoglobin dissociation during exercise
Stringer, W., Wasserman, K., Casaburi, R., Porszasz, J., Maehara, K., & French, W. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.4.1462 · Cited by 187
Muscle as a consumer of lactate
GLADDEN, L. B. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200004000-00008 · Cited by 181 · cited 1×
“During mild to moderate exercise intensity, although lactic acid was produced in skeletal muscles at any time even under fully aerobic conditions (Brooks 2000), most of the lactic acid could be reoxidized in the skeletal muscle and in other less active muscles ( Gladden 2000 ).”
BackgroundMogensen, M., Bagger, M., Pedersen, P. K., Fernström, M., & Sahlin, K. (2006) · The Journal of Physiology · doi:10.1113/jphysiol.2005.101691 · Cited by 179 · cited 2×
“It was reported that the _VO2-WR S1 was higher in cyclists than that in less-trained physical active subjects in Bones’ report (Boone et al. 2010), but not influenced by the training status in Mogensen’s report (Mogensen et al. 2006).”
BackgroundDickhuth, H.-H., Yin, L., Niess, A., Röcker, K., Mayer, F., Heitkamp, H.-C., & Horstmann, T. (1999) · International Journal of Sports Medicine · doi:10.1055/s-2007-971105 · Cited by 168
Stroke volume does not plateau during graded exercise in elite male distance runners
ZHOU, B., CONLEE, R. K., JENSEN, R., FELLINGHAM, G. W., GEORGE, J. D., & GARTH FISHER, A. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200111000-00008 · Cited by 160 · cited 2×
“There seems no significant difference in maximal C(a-v)O2 in legs between subjects with different exercise levels (Zhou et al. 2001; Sullivan et al. 1989).”
BackgroundMuscle Oxygenation Trends During Dynamic Exercise Measured by Near Infrared Spectroscopy
Bhambhani, Y. N. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-033 · Cited by 149 · cited 2×
“2001) has been introduced to the exercise physiology detection and has promoted our understanding of the aerobic metabolism in local skeletal muscles (Wolf et al. 2007; Hamaoka et al. 2007; Bhambhani 2004; Boushel et al. 2001; Zhang et al. 2010; Sako et al. 2001).”
BackgroundSako, T., Hamaoka, T., Higuchi, H., Kurosawa, Y., & Katsumura, T. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.1.338 · Cited by 132 · cited 2×
“2001) has been introduced to the exercise physiology detection and has promoted our understanding of the aerobic metabolism in local skeletal muscles (Wolf et al. 2007; Hamaoka et al. 2007; Bhambhani 2004; Boushel et al. 2001; Zhang et al. 2010; Sako et al. 2001).”
BackgroundComparison of computerized methods for detecting the ventilatory thresholds
Santos, E. L., & Giannella‐Neto, A. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1166-6 · Cited by 99 · cited 2×
“The V-slope method (Amann et al. 2004; Beaver et al. 1985) was also used to identify the GET automatically with a computer to confirm the GET iden- tified by the ventilatory equivalent method (Zhang et al. 2010; Santos and Giannella-Neto 2004).”
MethodPattern of deoxy[Hb + Mb] during ramp cycle exercise: influence of aerobic fitness status
Boone, J., Koppo, K., Barstow, T. J., & Bouckaert, J. J. (2009) · European Journal of Applied Physiology · doi:10.1007/s00421-008-0969-2 · Cited by 97 · cited 4×
“VO2 max between welltrained and less-trained groups (Demello et al. 1987; Boone et al. 2009; Hug et al. 2004), suggesting better aerobic fitness for the HL group, which might account for their better P800.”
BackgroundResultInfluentialBarstow, T. J., JONES, A. M., Nguyen, P. H., & Casaburi, R. H. (2000) · Experimental Physiology · doi:10.1111/j.1469-445x.2000.01942.x · Cited by 93 · cited 10×
“The slope of _ VO2 as a function of exercise intensity during exercise was calculated using linear regression analysis before ( _ VO2WR S1) and after ( _ VO2-WR S2) the GET (Scheuermann et al. 2002; Jones and Carter 2004; Barstow et al. 2000) (Fig.”
BackgroundMethodResultInfluentialAn evaluation of the predictive validity and reliability of ventilatory threshold
AMANN, M., SUBUDHI, A. W., WALKER, J., EISENMAN, P., SHULTZ, B., & FOSTER, C. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000142305.18543.34 · Cited by 90 · cited 4×
“The V-slope method (Amann et al. 2004; Beaver et al. 1985) was also used to identify the GET automatically with a computer to confirm the GET identified by the ventilatory equivalent method (Zhang et al.”
MethodInfluentialDetection of ventilatory threshold using near infrared spectroscopy in men and women
BHAMBHANI, Y. N., BUCKLEY, S. M., & SUSAKI, T. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199703000-00017 · Cited by 89 · cited 8×
“2009), the appearance sequence of them is still controversial (Zhang et al. 2010; Bhambhani et al. 1997; Grassi et al. 1999).”
BackgroundMethodInfluentialMc Naughton, L. R., Thompson, D., Philips, G., Backx, K., & Crickmore, L. (2002) · International Journal of Sports Medicine · doi:10.1055/s-2002-20133 · Cited by 86 · cited 2×
“Blood lactate concentration test Blood lactate concentration was measured using a portable lactate test meter (Lactate ProTM, LT-1710, Arkray, Shiga, Japan) (Pyne et al. 2000; Mc Naughton et al. 2002).”
MethodEMG versus oxygen uptake during cycling exercise in trained and untrained subjects
Hug, F., Decherchi, P., Marqueste, T., & Jammes, Y. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(03)00081-6 · Cited by 85 · cited 4×
“2002), and there was significant difference in these parameters between well trained and less trained groups (Demello et al. 1987; Hug et al. 2004).”
BackgroundResultInfluentialPlasma lactate and ventilation thresholds in trained and untrained cyclists
Simon, J., Young, J. L., Blood, D. K., Segal, K. R., Case, R. B., & Gutin, B. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.3.777 · Cited by 80 · cited 2×
“However, in Simon’s report the LT had no significant difference to the GET in trained subjects but the LT appeared significantly later than the GET in untrained subjects (Simon et al. 1986).”
BackgroundRelated Trends in Locomotor and Respiratory Muscle Oxygenation during Exercise
LEGRAND, R., MARLES, A., PRIEUR, F., LAZZARI, S., BLONDEL, N., & MUCCI, P. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000241638.90348.67 · Cited by 70 · cited 8×
“…equivalent method: GET was the break point at which there was an increase in the ventilatory equivalents for oxygen ( _VE= _VO2) versus time without a simultaneous increase in the ventilatory equivalents for carbon dioxide ( _VE= _VCO2) versus time (Legrand et al. 2007; Wasserman et al. 1973) (Fig.”
BackgroundMethodInfluentialLin, Y., Lech, G., Nioka, S., Intes, X., & Chance, B. (2002) · Review of Scientific Instruments · doi:10.1063/1.1485779 · Cited by 61 · cited 2×
“The photon path can be calculated from the known absorption coefficient and reduced scattering coefficient when the distance between the light source and the detector was set (Lin et al. 2002).”
BackgroundEMG and Oxygen Uptake Responses During Slow and Fast Ramp Exercise in Humans
Scheuermann, B. W., McConnell, J. H. T., & Barstow, T. J. (2002) · Experimental Physiology · doi:10.1113/eph8702246 · Cited by 60 · cited 10×
“It is reported that the slope of _ VO2-WR is associated with workload during incremental exercises (Jones et al. 2004; Scheuermann et al. 2002), so, the _ VO2-WR slope was calculated by linear regression separately for mild to moderate exercise intensity ( _ VO2-WR S1) and intensive exercise intensity ( _ VO2-WR S2) i…”
MethodResultInfluentialWhich common NIRS variable reflects muscle estimated lactate threshold most closely?
Wang, L., Yoshikawa, T., Hara, T., Nakao, H., Suzuki, T., & Fujimoto, S. (2006) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h06-069 · Cited by 54 · cited 2×
“In previous reports, different types of subjects were recruited to participate in incremental exercise tests, and the changes in muscle oxygenation were analyzed to get the break point (Bp) of muscle deoxygenation (Grassi et al. 1999; Wang et al. 2006; Belardinelli et al. 1995).”
BackgroundMethodArterial versus venous blood lactate increase in the forearm during incremental bicycle exercise
Yoshida, T., Takeuchi, N., & Suda, Y. (1982) · European Journal of Applied Physiology · doi:10.1007/bf00952247 · Cited by 50 · cited 2×
“When the lactic acid product exceeds the lactic acid removal in the muscles, the blood lactic acid increases nonlinearly (Yoshida et al. 1982) and more blood lactic acid will dissociate, inducing the significant increase in [La]b.”
BackgroundNon-linear cardiac output dynamics during ramp-incremental cycle ergometry
Stringer, W. W., Whipp, B. J., Wasserman, K., Pórszász, J., Christenson, P. D., & French, W. J. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1258-3 · Cited by 48 · cited 2×
“As reported previously, the arterial venous oxygen difference (C(a-v)O2) in legs increased as workload increased ( Stringer et al. 1997, 2005; Vella and Robergs 2005) and reached a maximal value at exhaustion.”
BackgroundComparison of three methods for detection of the lactate threshold
Davis, J. A., Rozenek, R., DeCicco, D. M., Carizzi, M. T., & Pham, P. H. (2007) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2007.00762.x · Cited by 46
Facilitation of Oxygen Consumption by Lactic Acidosis During Exercise
Wasserman, K., Hansen, J., & Sue, D. (1991) · Physiology · doi:10.1152/physiologyonline.1991.6.1.29 · Cited by 46 · cited 2×
“The increase in the concentration of H will accelerate the O2Hb dissociation via the Bohr effect and consequently accelerate the decrease in OI (Stringer et al. 1994; Wasserman et al. 1991).”
BackgroundInfluence of muscle fibre type and pedal rate on the V?O2-work rate slope during ramp exercise
JONES, A. M., Campbell, I. T., & PRINGLE, J. S. M. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0971-7 · Cited by 40 · cited 2×
“It is reported that the slope of _VO2-WR is associated with workload during incremental exercises (Jones et al. 2004; Scheuermann et al. 2002), so, the _VO2-WR slope was calculated by linear regression separately for mild to moderate exercise intensity ( _VO2-WR S1) and intensive exercise intensity…”
MethodBHAMBHANI, Y. N., Maikala, R. V., & Esmail, S. (2001) · European Journal of Applied Physiology · doi:10.1007/s004210000372 · Cited by 36 · cited 3×
“2007) until volitional fatigue or two of the following criteria (Bhambhani et al. 2001; Zhang et al. 2010) were attained: (1) heart rate (HR) C age-predicted maximal HR, which was calculated as 220 (age in years); (2) no further increase in oxygen uptake ( _ VO2) (increase of less than 100 mL/min) with increasing work…”
BackgroundMethodZhang, Z., Wang, B., Gong, H., Xu, G., Nioka, S., & Chance, B. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3309741 · Cited by 34 · cited 8×
“NIRS muscle oxygenation monitoring A CW-NIRS muscle oxygenation device (Zhang et al. 2009, 2010) developed in our lab was used to measure the muscle oxygenation in the right vastus lateralis muscle during the tests.”
BackgroundMethodSelf-citationA kinematic study of finswimming at surface.
Gautier, J., Baly, L., Zanone, P., & Watier, B. (2004) · Europe PMC (PubMed Central) · Cited by 33
Thin, A. G., Linnane, S. J., McKone, E. F., Freaney, R., FitzGerald, M. X., Gallagher, C. G., & McLoughlin, P. (2002) · CHEST Journal · doi:10.1378/chest.121.6.1761 · Cited by 32 · cited 4×
“There were significant correlations among these parameters (Wasserman et al. 1973; Thin et al. 2002), and there was significant difference in these parameters between well trained and less trained groups (Demello et al.”
BackgroundMethodInfluentialMuscle oxygenation trends during constant work rate cycle exercise in men and women
BHAMBHANI, Y., BUCKLEY, S., & SUSAKI, T. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199901000-00015 · Cited by 30 · cited 2×
“OI‐WR slopes, OI was normalized according to the formula (Eq. 3) ( Bhambhani et al. 1997, 1999 ) to compare among subjects.”
MethodVella, C. A., & Robergs, R. A. (2005) · PubMed · Cited by 29
Oxygen Uptake-Work Rate Relationship During Two Consecutive Ramp Exercise Tests
JONES, A. M., & Carter, H. (2004) · International Journal of Sports Medicine · doi:10.1055/s-2004-820960 · Cited by 29 · cited 4×
“The slope of _VO2 as a function of exercise intensity during exercise was calculated using linear regression analysis before ( _VO2WR S1) and after ( _VO2-WR S2) the GET (Scheuermann et al. 2002; Jones and Carter 2004; Barstow et al. 2000) (Fig.”
MethodResultInfluentialAerobic Fitness, Muscle Efficiency, and Motor Unit Recruitment during Ramp Exercise
Boone, J., Koppo, K., Barstow, T. J., & Bouckaert, J. J. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181b0f2e2 · Cited by 22 · cited 2×
“It was reported that the _VO2-WR S1 was higher in cyclists than that in less-trained physical active subjects in Bones’ report (Boone et al. 2010), but not influenced by the training status in Mogensen’s report (Mogensen et al. 2006).”
BackgroundAssessment of Continuous Skeletal Muscle Blood Flow during Exercise in Humans
Sørensen, V. B., Wroblewski, H., Galatius, S., Haunsø, S., & Kastrup, J. (2000) · Microvascular Research · doi:10.1006/mvre.1999.2219 · Cited by 15 · cited 1×
“However, more O2 was transferred into the active vastus lateralis by the increase in blood flow ( Sorensen et al. 2000 ), and so the oxygenation index decreased slightly but not significantly.”
BackgroundPortable muscle oxygenation monitor based on near infrared spectroscopy
Zhang, Z., Wang, B., Qing, N., Luo, Q., & Gong, H. (2009) · Frontiers of Optoelectronics in China · doi:10.1007/s12200-009-0050-8 · Cited by 12 · cited 2×
“The visual determination of the systemic physiological thresholds In this study, gas exchange threshold was evaluated visually by three investigators independently according to the venti- latory equivalent method.”
MethodSelf-citationBHAMBHANI, Y. N., Kennedy, M. D., & Maikala, R. V. (2009) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2009.10.004 · Cited by 6 · cited 2×
“Furthermore, significant higher O2 pulse in the HL group at thresholds and exhaustion indicated higher systemic oxygen uptake per heart beat, and suggested higher stroke volume (Bhambhani et al. 2001, 2010) in the HL group during intensive exercise.”
BackgroundWang, B., Tian, Q., Zhang, Z., & Gong, H. (2009) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.845434 · Cited by 1 · cited 4×
“Though the relationships among the three thresholds have been partly reported (Bhambhani et al. 1997; Zhang et al. 2010; Gaskill et al. 2001; Wang et al. 2009), the appearance sequence of them is still controversial (Zhang et al.”
BackgroundSelf-citation
Research works printed but not linked: 1
- Adam G, Kalaitzoglidis Y, Tsalis G (2005) Developments in Finswimming. Inq Sport Phys Educ 3(1):48–54
Cited by
van der Zwaard, S., Jaspers, R. T., Blokland, I. J., Achterberg, C., Visser, J. M., den Uil, A. R., Hofmijster, M. J., Levels, K., Noordhof, D. A., de Haan, A., et al. (2016) · PLOS ONE · doi:10.1371/journal.pone.0162914 · Cited by 95
“Previous studies have shown that Δ[O2HbMb-HHbMb]-BP preceded VT1 [18,19] and LT1 [18] or that Δ[O2HbMb-HHbMb]-BPwas not different from LT1 [17,19].”
BackgroundResultShang, Y., Gurley, K., Symons, B., Long, D., Srikuea, R., Crofford, L. J., Peterson, C. A., & Yu, G. (2012) · Arthritis Research & Therapy · doi:10.1186/ar4079 · Cited by 64
“On the other hand, following fatiguing exercise and cuff occlusion, extra oxygen is needed to compensate the oxygen loss in hemoglobin during exercise, and to oxidize lactate generated from anaerobic respiration [49].”
BackgroundJones, B., Dat, M., & Cooper, C. E. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.12.127002 · Cited by 37
Vilaça‐Alves, J., Freitas, N. M., Saavedra, F. J. F., Scott, C. B., Reis, V. M., Junior, R. F. S., & Garrido, N. D. (2016) · Journal of Human Kinetics · doi:10.1515/hukin-2016-0021 · Cited by 31
“4 - School of Physical Education and Sports, Rio de Janeiro Federal University, Rio de Janeiro, Brazil.”
(2012) · Europe PMC (PubMed Central) · Cited by 23
Self-citation
Metadata
- Authors
- Wang, B., Tian, Q., Zhang, Z., & Gong, H.
- Affiliations
- Wuhan National Laboratory for Optoelectronics (CN)
- Corresponding author
- Gong, Hui
- Venue
- European Journal of Applied Physiology
- Published
- 2011-05-25
- Volume
- 112
- Issue
- 2
- Pages
- 567-578
- ISSN
- 0020-9376 (ISSN-L)
- 1439-6319
- 1439-6327
- OpenAlex
- W2046830536
- Cited by
- 15
- References
- 57
- Citations by year
- 2024: 2 · 2021: 2 · 2020: 1 · 2018: 1 · 2017: 1 · 2016: 4 · 2015: 1 · 2014: 1 · 2012: 2
- FWCI
- 2.56
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- European Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Natural Science Foundation of China
- Program for Changjiang Scholars and Innovative Research Team in University
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Physiology (medical) › Exercise and Physiological Responses
- Keywords
- cardiorespiratory fitness, muscle oxygenation, near-infrared spectroscopy, vastus lateralis, lactate threshold, gas exchange threshold, blood lactate, oxygenation index, cardiopulmonary function, female athletes, incremental exercise
- MeSH terms
- Female, Humans, Oxygen Consumption, Physical Fitness, Swimming, Anaerobic Threshold, Exercise, Muscle, Skeletal, Lactic Acid, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.