The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
The detection and measurement of interleukin-6 in venous and capillary blood samples, and in sweat collected at rest and during exercise
Open accessAbstract
Purpose This study aimed to quantify the relationship between venous and capillary blood sampling methods for the measurement of plasma interleukin-6 (IL-6). A parallel study was conducted to determine the possibility of measuring IL-6 in sweat using an enzyme-linked immunosorbent assay (ELISA) and investigate the relationship between plasma- and sweat-derived measures of IL-6.Methods Twelve male participants were recruited for the measurement of IL-6 at rest and during exercise (study 1). An additional group of five female participants was recruited for the measurement of IL-6 in venous blood versus sweat at rest and following exercise (study 2). In study 1, venous and capillary blood samples were collected at rest and in response to exercise. In study 2, venous and sweat samples were collected following exercise.Results Mean plasma IL-6 concentration was not different between venous and capillary blood sampling methods either at rest (4.27 ± 5.40 vs. 4.14 ± 4.45 pg ml(-1)), during (5.40 ± 5.17 vs. 5.58 ± 6.34 pg ml(-1)), or in response to exercise (6.95 ± 6.37 vs. 6.99 ± 6.74 pg ml(-1)). There was no IL-6 detectable in sweat either at rest or following exercise.Conclusion There are no differences in the measurement of plasma IL-6 using either venous or capillary blood sampling methods. Capillary measurement represents a minimally invasive way of measuring IL-6 and detecting changes in IL-6, which are linked to fatigue and overtraining.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“although IL-6 and TNF-α are not consistently detected (Dai et al. 2013; Faulkner et al. 2014).”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Faulkner et al. 2014
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Calculation of percentage changes in volumes of blood, plasma, and red cells in dehydration.
Dill, D. B., & Costill, D. L. (1974) · Journal of Applied Physiology · doi:10.1152/jappl.1974.37.2.247 · Cited by 3,384
Cytokines sing the blues: inflammation and the pathogenesis of depression
Raison, C. L., Capuron, L., & Miller, A. H. (2006) · Trends in Immunology · doi:10.1016/j.it.2005.11.006 · Cited by 3,009
Isaacson, P. G., Dogan, A., Price, S. K., & Spencer, J. (1989) · The American Journal of Surgical Pathology · doi:10.1097/00000478-198912000-00004 · Cited by 1,915
Pro‐ and anti‐inflammatory cytokine balance in strenuous exercise in humans
Ostrowski, K., Rohde, T., Asp, S., Schjerling, P., & Pedersen, B. K. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.287ad.x · Cited by 1,014
Muscle‐derived interleukin‐6: mechanisms for activation and possible biological roles
FEBBRAIO, M. A., & PEDERSEN, B. K. (2002) · The FASEB Journal · doi:10.1096/fj.01-0876rev · Cited by 875 · cited 1×
“In response to exercise, IL-6 undergoes the most dramatic increase of any cytokine, with the increase dependent on the duration and intensity of the exercise bout (Febbraio and Pedersen 2002; Fischer 2006), with high intensity exercise resulting in the most pronounced response (Leggate et al. 2010).”
BackgroundInterleukin-6 in acute exercise and training: what is the biological relevance?
Fischer, C. P. (2026) · PubMed · doi:10.22029/eir.2006.1620 · Cited by 825
Inflammatory Markers and Risk of Type 2 Diabetes
Wang, X., Bao, W., Liu, J., OuYang, Y.-Y., Wang, D., Rong, S., Xiao, X., Shan, Z.-L., Zhang, Y., Yao, P., et al. (2013) · Diabetes Care · doi:10.2337/dc12-0702 · Cited by 820
The major inflammatory mediator interleukin-6 and obesity
Eder, K., Baffy, N., Falus, A., & Fulop, A. K. (2009) · Inflammation Research · doi:10.1007/s00011-009-0060-4 · Cited by 433
Research works printed but not linked: 1
- Cohen JW (1988) Statistical power analysis for the behavioural sciences, 2nd edn. Lawrence Erlbaum Associates, Hillside, NJ
Cited by
Physiological mechanisms determining eccrine sweat composition
Baker, L. B., & Wolfe, A. S. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04323-7 · Cited by 367
Wearable sweat sensing for prolonged, semicontinuous, and nonobtrusive health monitoring
Moonen, E. J. M., Haakma, J. R., Peri, E., Pelssers, E., Mischi, M., & den Toonder, J. M. J. (2020) · VIEW · doi:10.1002/viw.20200077 · Cited by 86
Label-free electronic detection of interleukin-6 using horizontally aligned carbon nanotubes
Chen, H., Choo, T. K., Huang, J., Wang, Y., Liu, Y., Platt, M., Palaniappan, A., Liedberg, B., & Tok, A. I. Y. (2015) · Materials & Design · doi:10.1016/j.matdes.2015.11.029 · Cited by 61
Self-citationHighly manufacturable graphene oxide biosensor for sensitive Interleukin-6 detection
Huang, J., Chen, H., Niu, W., Fam, D. W. H., Palaniappan, A., Larisika, M., Faulkner, S. H., Nowak, C., Nimmo, M. A., Liedberg, B., et al. (2015) · RSC Advances · doi:10.1039/c5ra05854f · Cited by 50
Self-citationConformal and Disposable Antenna-Based Sensor for Non-Invasive Sweat Monitoring
Eldamak, A. R., & Fear, E. C. (2018) · Sensors · doi:10.3390/s18124088 · Cited by 50
Metadata
- Authors
- Faulkner, S. H., Spilsbury, K. L., Harvey, J., Jackson, A., Huang, J., Platt, M., Tok, A., & Nimmo, M. A.
- Affiliations
- Loughborough University (GB)
- Nanyang Technological University (SG)
- Corresponding author
- Nimmo, Myra A.
- Venue
- European Journal of Applied Physiology
- Published
- 2014-03-01
- Volume
- 114
- Issue
- 6
- Pages
- 1207-1216
- ISSN
- 0020-9376 (ISSN-L)
- 1439-6319
- 1439-6327
- OpenAlex
- W2073487527
- Cited by
- 37
- References
- 46
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 4 · 2022: 2 · 2021: 1 · 2020: 3 · 2019: 2 · 2018: 7 · 2017: 4 · 2016: 3 · 2015: 6 · 2014: 3
- FWCI
- 5.16
- Type
- journal article
- Language
- en
- Open access
- green
- dspace.lboro.ac.uk
- Licence
- cc-by-nc-nd
- www.springer.com/tdm (tdm)
- Locations
- European Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Loughborough University Institutional Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Loughborough University Research Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Nottingham Trent University's Institutional Repository (Nottingham Trent Repository) (submittedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Exercise and Physiological Responses
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- interleukin-6, capillary blood sampling, venous blood sampling, sweat, physical activity, plasma cytokines, minimally invasive sampling, fatigue, overtraining
- MeSH terms
- Adult, Blood Chemical Analysis, Blood Specimen Collection, Capillaries, Female, Humans, Male, Rest, Sweat, Veins, Exercise, Interleukin-6
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The detection and measurement of interleukin-6 in venous and capillary blood samples, and in sweat collected at rest and during exercise. https://app.cochat.ai/papers/10.1007/s00421-014-2851-8
- The paper
- Faulkner, S. H., Spilsbury, K. L., Harvey, J., Jackson, A., Huang, J., Platt, M., Tok, A., & Nimmo, M. A. (2014). The detection and measurement of interleukin-6 in venous and capillary blood samples, and in sweat collected at rest and during exercise. European Journal of Applied Physiology. https://doi.org/10.1007/s00421-014-2851-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.