Effects of increased skin blood flow on muscle oxygenation/deoxygenation: comparison of time-resolved and continuous-wave near-infrared spectroscopy signals
The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Purpose We quantified the contribution of skin blood flow (SkBF) to tissue oxygenation/deoxygenation of the flexor digitorum profundus muscle during cutaneous vasodilation. Methods Time-resolved near-infrared spectroscopy (TRS-NIRS) was utilized to measure the potential influence of optical factors [mean optical pathlength (PL) and coefficients of absorption (μa) and reduced scattering ([Formula: see text])] on the NIRS-derived signals of eight male subjects. Results The approximately threefold elevation of SkBF during 1 h whole-body heating (increased internal temperature ~0.9 °C) increased both μa and [Formula: see text] without changing PL. Assuming that the [Formula: see text] coefficient remained constant, i.e., as with continuous-wave (CW) NIRS, resulted in a significant increase in the apparent oxygenation [oxy(Hb + Mb), from 113 ± 13 μM (mean ± SD) for control to 126 ± 13 for the increased SkBF condition, P Conclusions These findings support use of either NIRS method to estimate local muscle fractional O2 extraction, but not oxygenation, when SkBF is increased at rest.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Second, the SmO2 signal of the wearable, self-contained Moxy sensor may be more sensitive to changes in blood flow, and changes in tissue properties with small positioning inconsistencies compared to NIRS signals measured with more advanced stationary technologies (21, 47, 54, 55).”
From Comparing the reliability of muscle oxygen saturation with common performance and physiological markers across cycling exercise intensity (2023) · cites this paper as [55]
Citations
Cites
The Technic of Measuring Radiation and Convection
Hardy, J. D., Du Bois, E. F., & Soderstrom, G. F. (1938) · The Journal of Nutrition · doi:10.1093/jn/15.5.461 · Cited by 849
Owen-Reece, H., Smith, M., Elwell, C. E., & Goldstone, J. C. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.3.418 · Cited by 688
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669
Time domain functional NIRS imaging for human brain mapping
Torricelli, A., Contini, D., Pifferi, A., Caffini, M., Re, R., Zucchelli, L., & Spinelli, L. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.106 · Cited by 466
Ferrari, M., Muthalib, M., & Quaresima, V. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0230 · Cited by 450
Van Beekvelt, M. C. P., Colier, W. N. J. M., Wevers, R. A., & Van Engelen, B. G. M. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.511 · Cited by 430
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
DeLorey, D. S., Kowalchuk, J. M., & Paterson, D. H. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00956.2002 · Cited by 369
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Near‐infrared spectroscopy for monitoring muscle oxygenation
Boushel, R., & Piantadosi, C. A. (2000) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2000.00713.x · Cited by 299
Cited by
Understanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Self-citationBailey, S. J., Blackwell, J. R., Lord, T., Vanhatalo, A., Winyard, P. G., & Jones, A. M. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00192.2014 · Cited by 136
Boone, J., Vandekerckhove, K., Coomans, I., Prieur, F., & Bourgois, J. G. (2016) · European Journal of Applied Physiology · doi:10.1007/s00421-016-3468-x · Cited by 68
“…to the right with the breakpoint occurring at a higher intensity and an increased amplitude of the response factors, such as skin blood flow (Koga et al. 2015; Messere and Roatta 2015) and adipose tissue thickness (McCully and Hamaoka 2000; Van Beekvelt et al. 2001; Celie et al. 2016), most…”
BackgroundMcLay, K. M., Gilbertson, J. E., Pogliaghi, S., Paterson, D. H., & Murias, J. M. (2016) · Experimental Physiology · doi:10.1113/ep085843 · Cited by 68
Niemeijer, V. M., Jansen, J. P., van Dijk, T., Spee, R. F., Meijer, E. J., Kemps, H. M. C., & Wijn, P. F. F. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa5dd5 · Cited by 61
“However, recent work by Koga et al (2015b) using NIR-TRS revealed µ ′ s varies during exercise and whole body heating.”
Metadata
- Authors
- Koga, S., Poole, D. C., Kondo, N., Oue, A., Ohmae, E., & Barstow, T. J.
- Affiliations
- Kobe Design University (JP)
- Kansas State University (US)
- Kobe University (JP)
- Toyo University (JP)
- Hamamatsu Photonics (Japan) (JP)
- Corresponding author
- Koga, Shunsaku
- Venue
- European Journal of Applied Physiology
- Published
- 2014-10-14
- Volume
- 115
- Issue
- 2
- Pages
- 335-343
- ISSN
- 0020-9376 (ISSN-L)
- 1439-6319
- 1439-6327
- OpenAlex
- W1997810719
- Cited by
- 39
- References
- 46
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 4 · 2019: 4 · 2018: 2 · 2017: 2 · 2016: 10 · 2015: 6
- FWCI
- 4.67
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- European Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Japan Society for the Promotion of Science (26560362, 26350700)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Keywords
- skin blood flow, muscle oxygenation, muscle deoxygenation, flexor digitorum profundus, cutaneous vasodilation, whole-body heating, time-resolved near-infrared spectroscopy, optical path length, absorption coefficient, reduced scattering coefficient, hemoglobin, myoglobin
- MeSH terms
- Adult, Humans, Male, Oxygen Consumption, Regional Blood Flow, Skin, Vasodilation, Muscle, Skeletal, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.