CoChat

Effects of increased skin blood flow on muscle oxygenation/deoxygenation: comparison of time-resolved and continuous-wave near-infrared spectroscopy signals

Koga, Shunsaku, Poole, David C., Kondo, Narihiko, Oue, Anna, Ohmae, Etsuko, Barstow, Thomas J. · 2015 · European Journal of Applied Physiology

The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.

Abstract

Purpose We quantified the contribution of skin blood flow (SkBF) to tissue oxygenation/deoxygenation of the flexor digitorum profundus muscle during cutaneous vasodilation. Methods Time-resolved near-infrared spectroscopy (TRS-NIRS) was utilized to measure the potential influence of optical factors [mean optical pathlength (PL) and coefficients of absorption (μa) and reduced scattering ([Formula: see text])] on the NIRS-derived signals of eight male subjects. Results The approximately threefold elevation of SkBF during 1 h whole-body heating (increased internal temperature ~0.9 °C) increased both μa and [Formula: see text] without changing PL. Assuming that the [Formula: see text] coefficient remained constant, i.e., as with continuous-wave (CW) NIRS, resulted in a significant increase in the apparent oxygenation [oxy(Hb + Mb), from 113 ± 13 μM (mean ± SD) for control to 126 ± 13 for the increased SkBF condition, P Conclusions These findings support use of either NIRS method to estimate local muscle fractional O2 extraction, but not oxygenation, when SkBF is increased at rest.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00421-014-3019-2

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 47

Metadata

Authors
Koga, S., Poole, D. C., Kondo, N., Oue, A., Ohmae, E., & Barstow, T. J.
Affiliations
  • Kobe Design University (JP)
  • Kansas State University (US)
  • Kobe University (JP)
  • Toyo University (JP)
  • Hamamatsu Photonics (Japan) (JP)
Corresponding author
Koga, Shunsaku
Venue
European Journal of Applied Physiology
Published
2014-10-14
Volume
115
Issue
2
Pages
335-343
ISSN
  • 0020-9376 (ISSN-L)
  • 1439-6319
  • 1439-6327
OpenAlex
W1997810719
Cited by
39
References
46
Citations by year
2026: 2 · 2025: 1 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 4 · 2019: 4 · 2018: 2 · 2017: 2 · 2016: 10 · 2015: 6
FWCI
4.67
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • European Journal of Applied Physiology (publishedVersion)
  • PubMed (publishedVersion)
Funders
Japan Society for the Promotion of Science (26560362, 26350700)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
Keywords
skin blood flow, muscle oxygenation, muscle deoxygenation, flexor digitorum profundus, cutaneous vasodilation, whole-body heating, time-resolved near-infrared spectroscopy, optical path length, absorption coefficient, reduced scattering coefficient, hemoglobin, myoglobin
MeSH terms
Adult, Humans, Male, Oxygen Consumption, Regional Blood Flow, Skin, Vasodilation, Muscle, Skeletal, Spectroscopy, Near-Infrared

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.