Flexible piezoelectric micromachined ultrasonic transducer (pMUT) for application in brain stimulation
The DOI matches its Crossref record; 21 of the 22 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In recent years, profiting from the academic interest and deep exploration in neuroscience, flexible implantable stimulators with various mechanisms (electrical,[521–523] optogenetic,[524,525] ultrasonic,[526,527] magnetic[528]) are being developed as non-pharmacological treatment options.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [525]
Citations
Cites
Kinsler, L. E., Frey, A. R., & Bennett, G. S. (1951) · American Journal of Physics · doi:10.1119/1.1932798 · Cited by 3,375
Targeting abnormal neural circuits in mood and anxiety disorders: from the laboratory to the clinic
Ressler, K. J., & Mayberg, H. S. (2007) · Nature Neuroscience · doi:10.1038/nn1944 · Cited by 1,007
Transcranial Pulsed Ultrasound Stimulates Intact Brain Circuits
Tufail, Y., Matyushov, A., Baldwin, N., Tauchmann, M. L., Georges, J., Yoshihiro, A., Tillery, S. I. H., & Tyler, W. J. (2010) · Neuron · doi:10.1016/j.neuron.2010.05.008 · Cited by 977
Noninvasive Human Brain Stimulation
Wagner, T., Valero-Cabre, A., & Pascual-Leone, A. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.061206.133100 · Cited by 873
Surface micromachined capacitive ultrasonic transducers
Ladabaum, I., Jin, X., Soh, H. T., Atalar, A., & Khuri-Yakub, B. T. (1998) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.677612 · Cited by 581
Effective Parameters for Ultrasound-Induced In Vivo Neurostimulation
King, R. L., Brown, J. R., Newsome, W. T., & Pauly, K. B. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.09.009 · Cited by 491
Ultrasonic neuromodulation by brain stimulation with transcranial ultrasound
Tufail, Y., Yoshihiro, A., Pati, S., Li, M. M., & Tyler, W. J. (2011) · Nature Protocols · doi:10.1038/nprot.2011.371 · Cited by 473
A review of low-intensity focused ultrasound pulsation
Bystritsky, A., Korb, A. S., Douglas, P. K., Cohen, M. S., Melega, W. P., Mulgaonkar, A. P., DeSalles, A., Min, B.-K., & Yoo, S.-S. (2011) · Brain Stimulation · doi:10.1016/j.brs.2011.03.007 · Cited by 409
Remote Control of Neuronal Activity with a Light-Gated Glutamate Receptor
Szobota, S., Gorostiza, P., Del Bene, F., Wyart, C., Fortin, D. L., Kolstad, K. D., Tulyathan, O., Volgraf, M., Numano, R., Aaron, H. L., et al. (2007) · Neuron · doi:10.1016/j.neuron.2007.05.010 · Cited by 333
Biological effects of ultrasound: Development of safety guidelines. Part II: General review
Nyborg, W. L. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00333-1 · Cited by 306
Cited by
Flexible Hybrid Electronics for Digital Healthcare
Ma, Y., Zhang, Y., Cai, S., Han, Z., Liu, X., Wang, F., Cao, Y., Wang, Z., Li, H., Chen, Y., et al. (2020) · Advanced Materials · doi:10.1002/adma.201902062 · Cited by 620
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Soft wearable devices for deep-tissue sensing
Lin, M., Hu, H., Zhou, S., & Xu, S. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00427-y · Cited by 334
La, T., & Le, L. H. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202100798 · Cited by 150
Le, X., Shi, Q., Vachon, P., Ng, E. J., & Lee, C. (2021) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ac3ab9 · Cited by 139
Flexible electronics for cardiovascular healthcare monitoring
Zhang, T., Liu, N., Xu, J., Liu, Z., Zhou, Y., Yang, Y., Li, S., Huang, Y., & Jiang, S. (2023) · The Innovation · doi:10.1016/j.xinn.2023.100485 · Cited by 169
Towards controlled drug delivery in brain tumors with microbubble-enhanced focused ultrasound
Schoen, S. J., Kilinc, M. S., Lee, H., Guo, Y., Degertekin, F. L., Woodworth, G. F., & Arvanitis, C. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.114043 · Cited by 126
Piezoelectric Micromachined Ultrasound Transducer Technology: Recent Advances and Applications
He, Y., Wan, H., Jiang, X., & Peng, C. (2022) · Biosensors · doi:10.3390/bios13010055 · Cited by 108
An Emerging Era: Conformable Ultrasound Electronics
Zhang, L., Du, W., Kim, J., Yu, C., & Dağdeviren, C. (2023) · Advanced Materials · doi:10.1002/adma.202307664 · Cited by 108
de Marzo, G., Mastronardi, V., Algieri, L., Vergari, F., Pisano, F., Fachechi, L., Marras, S., Natta, L., Spagnolo, B., Brunetti, V., et al. (2022) · Advanced Electronic Materials · doi:10.1002/aelm.202200069 · Cited by 91
Flexible Body-Conformal Ultrasound Patches for Image-Guided Neuromodulation
Pashaei, V., Dehghanzadeh, P., Enwia, G., Bayat, M., Majerus, S. J. A., & Mandal, S. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2959439 · Cited by 79
“[15], the function of regional brain tissue in lagomorphs [16], [17] and rodents [18], [19], high-level cognitive behavior in monkeys [20], and the sciatic nerves of bullfrogs [21].”
BackgroundXue, X., Wu, H., Cai, Q., Chen, M., Moon, S., Huang, Z., Kim, T., Peng, C., Feng, W., Sharma, N., et al. (2023) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2023.3333318 · Cited by 77
Self-citationPiezoelectric thin films and their applications in MEMS: A review
Liu, J., Tan, H., Zhou, X. Y., Ma, W., Wang, C., An, T. N. M., Lu, W., Chen, F., Wang, J., & Zhang, H. (2025) · Journal of Applied Physics · doi:10.1063/5.0244749 · Cited by 74
Review of flexible microelectromechanical system sensors and devices
Yang, X., & Zhang, M. (2021) · Nanotechnology and Precision Engineering · doi:10.1063/10.0004301 · Cited by 67
Emerging ultrasonic bioelectronics for personalized healthcare
Jiang, L., & Wu, J. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2023.101110 · Cited by 67
Chen, W., Liu, J., Lei, S., Yang, Z., Zhang, Q., Li, Y., Huang, J., Dong, Y., Zheng, H., Wu, D., et al. (2023) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2023.3266367 · Cited by 61
Wearable ultrasound technology
Zhou, S., Park, G., Lin, M., Yang, X., & Xu, S. H. (2025) · Nature Reviews Bioengineering · doi:10.1038/s44222-025-00329-y · Cited by 79
Flexible Ultrasonic Transducer Array with Bulk PZT for Adjuvant Treatment of Bone Injury
Liu, H., Geng, J., Zhu, Q., Zhang, L., Wang, F., Chen, T., & Sun, L. (2019) · Sensors · doi:10.3390/s20010086 · Cited by 51
Organic Flexible Electronics for Innovative Applications in Electronic Skin
Liu, X., Li, H., Tao, M., Yu, Y., Zhu, Z., Wu, D., Hu, X., & Chen, Y. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202400661 · Cited by 62
Xue, X., Zhang, B., Moon, S., Xu, G., Huang, C., Sharma, N., & Jiang, X. (2023) · Biosensors · doi:10.3390/bios13010134 · Cited by 51
Flexible and Stretchable Ultrasonic Transducer Array Conformed to Complex Surfaces
Liu, W., Zhu, C., & Wu, D. (2020) · IEEE Electron Device Letters · doi:10.1109/led.2020.3045037 · Cited by 47
Lee, J., Ko, K., Shin, H., Oh, S.-J., Lee, C. J., Chou, N., Choi, N., Tack Oh, M., Chul Lee, B., Chan Jun, S., et al. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0070-5 · Cited by 44
Self-citationWearable ultrasound devices: An emerging era for biomedicine and clinical translation
Hu, H., Hu, C., Guo, W., Zhu, B., & Wang, S. (2024) · Ultrasonics · doi:10.1016/j.ultras.2024.107401 · Cited by 53
Ren, D., Yin, Y., Li, C., Chen, R., & Shi, J. (2023) · Micromachines · doi:10.3390/mi14010126 · Cited by 41
Thin-Film Piezoelectric Micromachined Ultrasound Transducers in Biomedical Applications: A Review
Wong, S., Roy, K., Lee, C., & Zhu, Y. H. (2024) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2024.3390807 · Cited by 43
Yuan, J., Li, Z., Zhao, Y., Luo, R., Qin, S., Li, J., Li, M., Han, G., Li, Z., Zhao, Z., et al. (2025) · Science Advances · doi:10.1126/sciadv.adw7632 · Cited by 49
Flexible micromachined ultrasound transducers (MUTs) for biomedical applications
Joshi, S. V., Sadeghpour, S., Kuznetsova, N., Wang, C., & Kraft, M. D. (2025) · Microsystems & Nanoengineering · doi:10.1038/s41378-024-00783-5 · Cited by 45
Ultra‐Broadband Flexible Thin‐Film Sensor for Sound Monitoring and Ultrasonic Diagnosis
Xia, Y., Sun, C., Liu, W., Wang, X., Wen, K., Feng, Z., Zhang, G., Fan, E., He, Q., Lin, Z., et al. (2023) · Small · doi:10.1002/smll.202305678 · Cited by 35
Omidvar, A., Cretu, E., Rohling, R. N., Cresswell, M., & Hodgson, A. J. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202201316 · Cited by 33
Liu, W., & Wu, D. (2020) · Sensors · doi:10.3390/s20113333 · Cited by 30
Body Conformal Linear Ultrasound Array for Combined Ultrasound and Photoacoustic Imaging
Roy, K., Agrawal, S., Dangi, A., Liu, T., Chen, H., Jackson, T. N., Pratap, R., & Kothapalli, S. (2020) · IEEE International Ultrasonics Symposium · doi:10.1109/ius46767.2020.9251458 · Cited by 30
Sadeghpour, S., Lips, B., Kraft, M. D., & Puers, R. (2020) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2020.2972729 · Cited by 26
Integrated Piezoelectric AlN Thin Film with SU-8/PDMS Supporting Layer for Flexible Sensor Array
Yeo, H. G., Jung, J., Sim, M., Jang, J. E., & Choi, H. (2020) · Sensors · doi:10.3390/s20010315 · Cited by 25
Liu, H., Fan, J., Lin, X., Lin, K., Wang, S., Liu, S., Wang, F., & Song, J. (2024) · npj Flexible Electronics · doi:10.1038/s41528-024-00354-8 · Cited by 23
Fully Flexible PMUT Based on Polymer Materials and Stress Compensation by Adaptive Frequency Driving
Jeong, Y., Genoe, J., Gijsenbergh, P., Segers, J., Heremans, P. L., & Cheyns, D. (2020) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2020.3043052 · Cited by 21
Electromechanical Equivalent Circuit Model for Axisymmetric PMUTs With Elastic Boundary Conditions
Chare, C., Gijsenbergh, P., Jeong, Y., Heremans, P. L., Cheyns, D., & Genoe, J. (2022) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2022.3151245 · Cited by 19
Bendable Phased-Array Ultrasound Transducer for Imaging on Curved Surfaces
Yin, S., Zhang, H., Shi, F., Chen, Y., Zhong, C., Li, R., & Su, Y. (2025) · ACS Nano · doi:10.1021/acsnano.4c16028 · Cited by 17
Bone Fracture Healing under the Intervention of a Stretchable Ultrasound Array
Liu, H., Ding, S., Lin, X., Wang, S., Wang, Y., Feng, Z., & Song, J. (2024) · ACS Nano · doi:10.1021/acsnano.4c02426 · Cited by 16
Shape estimation of flexible ultrasound arrays using spatial coherence: A preliminary study
Omidvar, A., Rohling, R. N., Cretu, E., Cresswell, M., & Hodgson, A. J. (2023) · Ultrasonics · doi:10.1016/j.ultras.2023.107171 · Cited by 15
Ultrasound brain stimulation technologies for targeted therapeutics
Jo, Y., Kim, S., Jeong, J., & Lee, H. J. (2025) · Nature Electronics · doi:10.1038/s41928-025-01420-3 · Cited by 27
Wearable Ultrasound Devices for Biomedical Applications
Wang, M., Jia, L., Li, H., & Feng, X. (2025) · FlexTech · doi:10.1002/fle2.70001 · Cited by 17
A 3D Printed Device for Low Cost Neural Stimulation in Mice
Morrison, T., Sefton, E., Marquez-Chin, M., Popović, M. R., Morshead, C. M., & Naguib, H. E. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00784 · Cited by 15
Conformal Ultrasound Transducer Array for Image-Guided Neural Therapy
Pashaei, V., Roman, A., & Mandal, S. (2018) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2018.8584727 · Cited by 12
Flexible PZT-Based Row-Column Addressed 2-D PMUT Array
Joshi, S. V., Sadeghpour, S., & Kraft, M. D. (2024) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2024.3465589 · Cited by 11
Fabrication of High-Frequency 2D Flexible pMUT Array
Joshi, S. V., Sadeghpour, S., & Kraft, M. D. (2023) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems49605.2023.10052246 · Cited by 10
Design and micromachining of a stretchable two-dimensional ultrasonic array
Liu, W., Chen, W., Zhu, C., & Wu, D. (2021) · Micro and Nano Engineering · doi:10.1016/j.mne.2021.100096 · Cited by 10
Liu, W., Li, X., Wu, D., & Yu, T. (2019) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2019.8925776 · Cited by 8
Wearable flexible ultrasonic transducers: materials, applications, and challenges
Guo, L., Liu, J., Li, Y., Xu, R., Song, G., Wu, J., Qian, Z., Ren, L., Ren, L., & Zhou, Q. (2025) · Ultrasonics · doi:10.1016/j.ultras.2025.107872 · Cited by 11
Sun, C., Su, W., & Liu, Y. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114289 · Cited by 5
PMUT Package Design Optimization via Machine Learning
Teng, M., Yue, W., Peng, Y., Tsao, P.-C., Deng, H., Fan, X., & Lin, L. (2024) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems58180.2024.10439496 · Cited by 5
Preliminary Demonstration of Pulse-Echo Imaging With a Long Monolithic Flexible CMUT Array
Omidvar, A., Rohling, R. N., Cretu, E., Cresswell, M., & Hodgson, A. J. (2024) · IEEE Open Journal of Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/ojuffc.2024.3506532 · Cited by 4
Lu, J., Yan, Y., Xu, J., & Gao, Y. (2024) · Sensors · doi:10.3390/s24175635 · Cited by 3
Yan, M., Wang, Z., Li, Z. K., Wang, P., Wu, P., Chen, X., Chen, X., Du, L., Wang, Y., Song, J., et al. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01158-8 · Cited by 7
Green and flexible pMUT based on transparent piezoelectric chitosan thin film
de Marzo, G., Mastronardi, V., Algieri, L., Vergari, F., Pisano, F., Fachechi, L., Natta, L., Ascanio, G., Rizzi, F., Pisanello, F., et al. (2022) · IEEE International Conference on Nanotechnology (IEEE-NANO) · doi:10.1109/nano54668.2022.9928608 · Cited by 2
Stretchable Ultrasonic Linear Array Based On Laser Processing
Liu, W., Wang, H., Zhu, C., & Wu, D. (2021) · Symposium on Piezoelectricity, Acoustic Waves and Device Applications · doi:10.1109/spawda51471.2021.9445552 · Cited by 2
Ferroelectrics for Biomedical Applications
Chen, D. (2017) · Global Journal of Nanomedicine · doi:10.19080/gjn.2017.02.555599 · Cited by 2
Round-Trip Sensitivity-Bandwidth Optimization and Characterization of High-Frequency PMUTs
He, L., Lv, N., Xü, W.-J., Wang, Y., & Ren, J. (2023) · IEEE International Symposium on Applications of Ferroelectrics (ISAF) · doi:10.1109/isaf53668.2023.10265321 · Cited by 1
Design and Modeling of a Dual-Driving PMUT with Increased Round-Trip Sensitivity
He, L., Lv, N., Wang, Y., Xü, W.-J., & Ren, J. (2023) · IEEE International Symposium on Applications of Ferroelectrics (ISAF) · doi:10.1109/isaf53668.2023.10265682 · Cited by 1
Chen, B., Yu, J., Fan, J., Ma, Y., Gečevska, V., & Zhang, X. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116954 · Cited by 2
PiezoMEMS Fabrication on Flexible Stainless-Steel Substrates
Nakamura, K., Huang, C.-L., Akhyari, A. H., Argüelles, A. P., Jackson, T. N., & Trolier-McKinstry, S. E. (2026) · Sensors · doi:10.3390/s26072246 · Cited by 1
Defect Detection of Complex-Shaped Structure Based on Flexible PMUT Linear Array
Sun, C., Xing, Z., Sun, X., & Ji, W. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3686380 · Cited by 1
Goepfert, V., Boulmé, A., Levassort, F., Merrien, T., Rouffaud, R., & Certon, D. (2023) · Micromachines · doi:10.3390/mi14112089 · Cited by 1
Shape Estimation of Ultrasound Arrays Using Spatial Coherence: A Preliminary StudyPreprint
Omidvar, A., Rohling, R. N., Cretu, E., Cresswell, M., & Hodgson, A. J. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4509572
Zhang, X., Wang, J., Bao, A., Yang, C., Xia, J., Sheng, B., Wang, W., & Lu, Y. (2025) · IEEE International Ultrasonics Symposium · doi:10.1109/ius62464.2025.11201354
Differential 3-Ring Electrode PMUTS with High Acoustic Pressure for Glaucoma Optic Neuroprotection
Yang, K., Wang, Z., Wang, J., Yang, C., Gao, Y., Xia, J., Yang, F., Sheng, B., Wu, H., & Lu, Y. (2026) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems64181.2026.11419537
Design and Fabrication of Flexible Lead-Free PMUTs via KNN-on-SU-8 Heterogeneous Integration
Zhang, Z., Qin, S., Yuan, J., Li, Z., Wang, Y., An, D., Li, M., Lin, Z., Zhao, Y., Li, Z., et al. (2026) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems69704.2026.11633778
Lv, N., Gao, Y., Ye, F., & Ren, J. (2026) · Measurement · doi:10.1016/j.measurement.2026.123044
Xu, J., Schrag, G., Da, Z., Wang, Y., Shatalov, A., Savoia, A. S., & Xu, T. (2026) · IEEE Open Journal of Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/ojuffc.2026.3734815
Metadata
- Authors
- Lee, J.-H., Cho, I.-J., Ko, K., Yoon, E.-S., Park, H.-H., & Kim, T. S.
- Affiliations
- Yonsei University (KR)
- Korea Institute of Science and Technology (KR)
- Corresponding author
- Kim, Tae Song
- Venue
- Microsystem Technologies
- Published
- 2016-04-29
- Volume
- 23
- Issue
- 7
- Pages
- 2321-2328
- ISSN
- 0946-7076 (ISSN-L)
- 1432-1858
- OpenAlex
- W2343330309
- Semantic Scholar
- 580bb57dd6e1f4d3eae95c562a74c0684e985618
- Cited by
- 68
- References
- 22
- Citations by year
- 2026: 7 · 2025: 10 · 2024: 9 · 2023: 15 · 2022: 6 · 2021: 7 · 2020: 6 · 2019: 6 · 2018: 1 · 2017: 1
- FWCI
- 2.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Microsystem Technologies (publishedVersion)
- Funders
- The KIST Institutional Program (2E25590)
- Topics
- Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
- Physical Sciences › Materials Science › Materials Chemistry › Ferroelectric and Piezoelectric Materials
- Physical Sciences › Engineering › Control and Systems Engineering › Piezoelectric Actuators and Control
- Keywords
- piezoelectric micromachined ultrasonic transducers, PMUT array, brain stimulation, low-intensity ultrasound, polydimethylsiloxane substrate, lead zirconate titanate thin films, oxygen plasma surface treatment, resonant frequency, sound pressure level, mouse brain
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).