Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 53 of the 54 references it cites were found in a registry or an index.

Flexible Body-Conformal Ultrasound Patches for Image-Guided Neuromodulation

Pashaei, Vida, Dehghanzadeh, Parisa, Enwia, George, Bayat, Mahdi, Majerus, Steve J. A., Mandal, Soumyajit · 2020 · IEEE Transactions on Biomedical Circuits and Systems

Abstract

The paper presents the design and validation of body-conformal active ultrasound patches with integrated imaging and modulation modalities for image-guided neural therapy. A mechanically-flexible linear 64-element array of piezoelectric transducers with a resonance frequency of 5 MHz was designed for nerve localization. A second 8-element array using larger elements was integrated on the wearable probe for low intensity focused ultrasound neuromodulation at a resonance frequency of 1.3 MHz. Full-wave simulations were used to model the flexible arrays and estimate their generated pressure profiles. A focal depth of 10-20 mm was assumed for beamforming and focusing to support modulation of the vagus, tibial, and other nerves. A strain sensor integrated on the probe provides patient-specific feedback information on array curvature for real-time optimization of focusing and image processing. Each patch also includes high voltage (HV) multiplexers, transmit/receive switches, and pre-amplifiers that simplify connectivity and also improve the signal-to-noise ratio (SNR) of the received echo signals by ∼ 5 dB. Experimental results from a flexible prototype show a sensitivity of 80 kPa/V with ∼ 3 MHz bandwidth for the modulation and 20 kPa/V with ∼ 6 MHz bandwidth for the imaging array. An algorithm for accurate and automatic localization of targeted nerves based on using nearby blood vessels (e.g., the carotid artery) as image markers is also presented.

Overview

Integrity signals

Registry

Crossref · 10.1109/tbcas.2019.2959439

Cites

53 of 53 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 54 references

Research works printed but not linked: 3

  1. aggarwal, 0, Automated positioning of ultrasonic probes, Proc Nat Aerosp Electron Conf, 1
  2. kaczmarek, 1987, et�al
  3. jensen, 0, Field: A program for simulating ultrasound systems, Proc 10th NordicBaltic Conf Biomed Imag, 4, 351

Cited by

See all 79

Metadata

Authors
Pashaei, V., Dehghanzadeh, P., Enwia, G., Bayat, M., Majerus, S. J. A., & Mandal, S.
Affiliations
  • Case Western Reserve University (US)
  • Louis Stokes Cleveland VA Medical Center (US)
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2020-04
Volume
14
Issue
2
Pages
305-318
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2995958784
Cited by
79
References
54
Citations by year
2026: 6 · 2025: 10 · 2024: 16 · 2023: 25 · 2022: 10 · 2021: 10 · 2020: 2
FWCI
1.94
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Ultrasound and Hyperthermia Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
  • Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
Keywords
low-intensity focused ultrasound, piezoelectric transducer array, nerve localization, strain sensors, beamforming, multiplexer, vagus nerve, tibial nerve
MeSH terms
Algorithms, Transcutaneous Electric Nerve Stimulation, Humans, Image Processing, Computer-Assisted, Neck, Signal Processing, Computer-Assisted, Ultrasonography, Ultrasonic Therapy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Flexible Body-Conformal Ultrasound Patches for Image-Guided Neuromodulation. https://app.cochat.ai/papers/10.1109/tbcas.2019.2959439
The paper
Pashaei, V., Dehghanzadeh, P., Enwia, G., Bayat, M., Majerus, S. J. A., & Mandal, S. (2020). Flexible Body-Conformal Ultrasound Patches for Image-Guided Neuromodulation. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2019.2959439

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.