Surgical and hardware complications of deep brain stimulation. A seven-year experience and review of the literature
The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2001) · New England Journal of Medicine · doi:10.1056/nejmoa000827 · Cited by 1,514
Subthalamic nucleus deep brain stimulation: Summary and meta-analysis of outcomes
Kleiner-Fisman, G., Herzog, J., Fisman, D. N., Tamma, F., Lyons, K. E., Pahwa, R., Lang, A. E., & Deuschl, G. (2006) · Movement Disorders · doi:10.1002/mds.20962 · Cited by 957
Mallet, L., Schüpbach, M., N'Diaye, K., Remy, P., Bardinet, E., Czernecki, V., Welter, M.-L., Pelissolo, A., Ruberg, M., Agid, Y., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610849104 · Cited by 437 · cited 1×
“Postoperative mental changes may be suggestive with deep placement of the lower contact, close to the SNr [ 36 , 43].”
BackgroundSafety and efficacy of pallidal or subthalamic nucleus stimulation in advanced PD
Volkmann, J., Allert, N., Voges, J., Weiss, P. H., Freund, H.-J., & Sturm, V. (2001) · Neurology · doi:10.1212/wnl.56.4.548 · Cited by 425
Long-term Hardware-related Complications of Deep Brain Stimulation
Oh, M. Y., Abosch, A., Kim, S. H., Lang, A. E., & Lozano, A. M. (2002) · Neurosurgery · doi:10.1097/00006123-200206000-00017 · Cited by 405 · cited 3×
“Our literature review reveals a mean rate of 5% per patient and 1.8% per procedure for postoperative electrode breakage [7, 9, 13, 17, 26, 29, 35, 38 , 51, 54].”
BackgroundInfluentialKleiner-Fisman, G., Fisman, D. N., Sime, E., Saint-Cyr, J. A., Lozano, A. M., & Lang, A. E. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.99.3.0489 · Cited by 351
Intraoperative microrecordings of the subthalamic nucleus in Parkinson's disease
Benazzouz, A., Breit, S., Koudsie, A., Pollak, P., Krack, P., & Benabid, A.-L. (2002) · Movement Disorders · doi:10.1002/mds.10156 · Cited by 338 · cited 1×
“Those in favor of MER suggest that the use of electrophysiological localization methods can improve the accuracy of DBS targeting, thus reducing stimulation-induced complications [ 6 , 52].”
BackgroundNeuropsychological changes between “off” and “on” STN or GPi stimulation in Parkinson’s disease
Pillon, B., Ardouin, C., Damier, P., Krack, P., Houeto, J. L., Klinger, H., Bonnet, A. M., Pollak, P., Benabid, A. L., & Agid, Y. (2000) · Neurology · doi:10.1212/wnl.55.3.411 · Cited by 332
Bilateral stimulation of globus pallidus internus for treatment of cervical dystonia
Krauss, J. (1999) · The Lancet · doi:10.1016/s0140-6736(99)03084-6 · Cited by 321
Complications of Deep Brain Stimulation Surgery
Beric, A., Kelly, P. J., Rezai, A., Sterio, D., Mogilner, A., Zonenshayn, M., & Kopell, B. (2001) · Stereotactic and Functional Neurosurgery · doi:10.1159/000064600 · Cited by 316 · cited 3×
“Occasionally, patients undergoing DBS will encounter seizures [ 7 , 12, 19].”
BackgroundInfluentialSubthalamic DBS replaces levodopa in Parkinson’s disease: Two-year follow-up
Vingerhoets, F. J. G., Villemure, J.-G., Temperli, P., Pollo, C., Pralong, E., & Ghika, J. (2002) · Neurology · doi:10.1212/wnl.58.3.396 · Cited by 314
Binder, D. K., Rau, G. M., & Starr, P. A. (2005) · Neurosurgery · doi:10.1227/01.neu.0000156473.57196.7e · Cited by 296 · cited 3×
“did not find any significant difference in bleeding rate and the number of tracts used [ 8 ].”
BackgroundInfluentialTwo‐year follow‐up of subthalamic deep brain stimulation in Parkinson's disease
Herzog, J., Volkmann, J., Krack, P., Kopper, F., Pötter, M., Lorenz, D., Steinbach, M., Klebe, S., Hamel, W., Schrader, B., et al. (2003) · Movement Disorders · doi:10.1002/mds.10518 · Cited by 296
Isease, S. D., & Roup, S. T. G. (2001) · Cited by 292
Deep brain stimulation for movement disorders: morbidity and mortality in 109 patients
Umemura, A., Jaggi, J. L., Hurtig, H. I., Siderowf, A. D., Colcher, A., Stern, M. B., & Baltuch, G. H. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.98.4.0779 · Cited by 279 · cited 4×
“Previous studies have reported serious surgical complications resulting in persistent neurologic deficit in up to 6% of patients [7, 8, 54 ].”
BackgroundInfluentialNeuroleptic malignant syndrome
Adnet, P., Lestavel, P., & Krivosic-Horber, R. (2000) · British Journal of Anaesthesia · doi:10.1093/bja/85.1.129 · Cited by 278 · cited 1×
“It is a rare but potentially fatal disorder, with a mortality rate between 10% and 30%; it is characterized by fever, severe rigidity, autonomic instability, and altered level of consciousness [ 1 ].”
BackgroundVoges, J. (2006) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2005.081232 · Cited by 273 · cited 1×
“Perioperative infection rates presenting within 6 months of surgery are most likely around 1.5–4.5% [ 58 ].”
BackgroundInfluentialSurgical and hardware complications of subthalamic stimulation: A series of 160 procedures
Lyons, K. E., Wilkinson, S. B., Overman, J., & Pahwa, R. (2004) · Neurology · doi:10.1212/01.wnl.0000134650.91974.1a · Cited by 271
Funkiewiez, A., Ardouin, C., Krack, P., Fraix, V., Van Blercom, N., Xie, J., Moro, E., Benabid, A., & Pollak, P. (2003) · Movement Disorders · doi:10.1002/mds.10441 · Cited by 264 · cited 4×
“Postoperative mood changes, especially agitation and confusion, are expected after DBS, especially when the STN is involved, even in patients with normal preoperative neuropsychological tests [ 16 ].”
BackgroundInfluentialDeep Brain Stimulation for Dystonia
Krauss, J. K., Yianni, J., Loher, T. J., & Aziz, T. Z. (2004) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200401000-00004 · Cited by 256
Pallidal neuronal activity: Implications for models of dystonia
Hutchison, W. D., Lang, A. E., Dostrovsky, J. O., & Lozano, A. M. (2003) · Annals of Neurology · doi:10.1002/ana.10474 · Cited by 240 · cited 1×
“We opted to terminate the procedure at that time rather than intubate the patient; general anesthesia can diminish the electrophysiological activity that can be obtained and in some cases alter the characteristics of microelectrode recordings [ 23 , 39].”
MethodDEEP BRAIN STIMULATOR HARDWARE-RELATED INFECTIONS: INCIDENCE AND MANAGEMENT IN A LARGE SERIES
Sillay, K. A., Larson, P. S., & Starr, P. A. (2008) · Neurosurgery · doi:10.1227/01.neu.0000316002.03765.33 · Cited by 225 · cited 2×
“The reported infection risk varies significantly between the various groups, from 0% to 15% per patient or 0% to 9.7% per electrode [ 46 ].”
BackgroundInfluentialHardware-related complications of deep brain stimulation: a ten year experience
Blomstedt, P., & Hariz, M. I. (2005) · Acta Neurochirurgica · doi:10.1007/s00701-005-0576-5 · Cited by 213 · cited 3×
“Our literature review reveals a mean rate of 5% per patient and 1.8% per procedure for postoperative electrode breakage [7, 9 , 13, 17, 26, 29, 35, 38, 51, 54].”
BackgroundInfluentialSubthalamic nucleus stimulation in Parkinson's disease
Thobois, S., Mertens, P., Guenot, M., Hermier, M., Mollion, H., Bouvard, M., Chazot, G., Broussolle, E., & Sindou, M. (2002) · Journal of Neurology · doi:10.1007/s004150200059 · Cited by 199
Godinho, F., Thobois, S., Magnin, M., Guenot, M., Polo, G., Benatru, I., Xie, J., Salvetti, A., Garcia-Larrea, L., Broussolle, E., et al. (2006) · Journal of Neurology · doi:10.1007/s00415-006-0222-z · Cited by 176
Østergaard, K., & Aa. Sunde, N. (2006) · Movement Disorders · doi:10.1002/mds.20776 · Cited by 171
Hariz, M. I., & Fodstad, H. (1999) · Stereotactic and Functional Neurosurgery · doi:10.1159/000029720 · Cited by 163
Hardware-Related problems of deep brain stimulation
Joint, C., Nandi, D., Parkin, S., Gregory, R., & Aziz, T. (2002) · Movement Disorders · doi:10.1002/mds.10161 · Cited by 152 · cited 3×
“We also prefer compact, low-profile hardware connectors to the larger, first-generation ones that have been associated with increased risk of skin erosion [ 26 ].”
BackgroundInfluentialSimuni, T., Jaggi, J. L., Mulholland, H., Hurtig, H. I., Colcher, A., Siderowf, A. D., Ravina, B., Skolnick, B. E., Goldstein, R., Stern, M. B., et al. (2002) · Journal of Neurosurgery · doi:10.3171/jns.2002.96.4.0666 · Cited by 147
What the future holds for deep brain stimulation
Benabid, A. L. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.6.895 · Cited by 142 · cited 1×
“Deep brain stimulation (DBS) has been established as an efficient, adaptable, and reversible method for the treatment of movement disorders, especially Parkinson’ sd isease (PD), dystonia, and tremor, while an expanding array of indications continues to emerge [ 5 ].”
MethodSafety and Risk of Microelectrode Recording in Surgery for Movement Disorders
Hariz, M. I. (2002) · Stereotactic and Functional Neurosurgery · doi:10.1159/000068960 · Cited by 141 · cited 3×
“For that reason, the use of MER is still controversial; it has been suggested that MER increases the intraoperative morbidity without significantly improving clinical outcome and that the risk of intraoperative hemorrhage is proportional to the number of microelectrode tracts [14, 19 , 20].”
BackgroundMethodInfluentialAntibiotic prophylaxis for cerebrospinal fluid shunts: a metanalysis.
Haines, S. J., & Walters, B. C. (1994) · PubMed · Cited by 141
Reducing Hardware-Related Complications of Deep Brain Stimulation
Constantoyannis, C., Berk, Ç., Honey, C. R., Mendez, I. M., & Brownstone, R. M. (2005) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/s0317167100003966 · Cited by 139
Hardware-Related Complications after Placement of Thalamic Deep Brain Stimulator Systems
Kondziolka, D., Whiting, D., Germanwala, A., & Oh, M. (2002) · Stereotactic and Functional Neurosurgery · doi:10.1159/000070836 · Cited by 137 · cited 2×
“From the literature reviewed, authors report an average lead migration rate of 4.4% per electrode [9, 13, 17, 26, 29 , 35, 38].”
BackgroundInfluentialBilateral subthalamic nucleus stimulation improves health-related quality of life in PD
Lagrange, E., Krack, P., Moro, E., Ardouin, C., Blercom, N. V., Chabardès, S., Benabid, A., & Pollak, P. (2002) · Neurology · doi:10.1212/01.wnl.0000037486.82390.1c · Cited by 126
Goodman, R. R. (2006) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2005.069161 · Cited by 123 · cited 2×
“From the literature reviewed, authors report an average lead migration rate of 4.4% per electrode [9, 13, 17 , 26, 29, 35, 38].”
BackgroundInfluentialValldeoriola, F., Pilleri, M., TOLOSA, E. S., Molinuevo, J. L., Rumià, J., & Ferrer, E. (2002) · Movement Disorders · doi:10.1002/mds.1278 · Cited by 104 · cited 1×
“Procedure-related mortality in DBS is low, with only three cases of perioperative deaths related to the procedure reported in the literature [42, 48, 55 ].”
ResultVesper, J., Klostermann, F., Stockhammer, F., Funk, T., & Brock, M. (2002) · Surgical Neurology · doi:10.1016/s0090-3019(02)00691-2 · Cited by 94
Ford, B. (2004) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.2003.027557 · Cited by 93
Management of hardware infections following deep brain stimulation
van der Linden, C., van de Kar, T., Visser-Vandewalle, V. E. R. M., Temel, Y., Ackermans, L. P. C. M., Celik, H. H., Spincemaille, G. H. J. J., & Walenkamp, G. H. I. M. (2004) · Acta Neurochirurgica · doi:10.1007/s00701-004-0219-2 · Cited by 90 · cited 2×
“Sillay et al. [46] 420 (759) 4.5 NA NA Temel et al. [ 51 ] 106 (178) 3.8 NA NA”
BackgroundInfluentialTemel, Y., Wilbrink, P., Duits, A., Boon, P., Tromp, S. C., Ackermans, L. P. C. M., van Kranen-Mastenbroek, V. H. J. M., Weber, W. E. J., & Visser-Vandewalle, V. E. R. M. (2007) · Operative Neurosurgery · doi:10.1227/01.neu.0000303993.82149.98 · Cited by 84 · cited 1×
“Those in favor of MER suggest that the use of electrophysiological localization methods can improve the accuracy of DBS targeting, thus reducing stimulation-induced complications [6, 52 ].”
BackgroundChronic inhibition of the subthalamic nucleus in Parkinson's disease
Krause, M., Fogel, W., Mayer, P., Kloß, M., & Tronnier, V. M. (2004) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2004.01.004 · Cited by 82
Effects of Sevoflurane on Central Nervous System Electrical Activity in Cats
Osawa, M., Shingu, K., Murakawa, M., Adachi, T., Kurata, J., Seo, N., Murayama, T., Nakao, S., & Mori, K. (1994) · Anesthesia & Analgesia · doi:10.1213/00000539-199407000-00011 · Cited by 68 · cited 1×
“We opted to terminate the procedure at that time rather than intubate the patient; general anesthesia can diminish the electrophysiological activity that can be obtained and in some cases alter the characteristics of microelectrode recordings [23, 39 ].”
MethodJaggi, J. L., Jaggi, J. L., Umemura, A., Umemura, A., Hurtig, H. I., Hurtig, H. I., Siderowf, A. D., Siderowf, A. D., Colcher, A., Colcher, A., et al. (2004) · Stereotactic and Functional Neurosurgery · doi:10.1159/000078145 · Cited by 66
Infected CNS infusion pumps. Is there a chance for treatment without removal?
Boviatsis, E., Kouyialis, A. T., Boutsikakis, I., Korfias, S. I., & Sakas, D. E. (2004) · Acta Neurochirurgica · doi:10.1007/s00701-004-0217-4 · Cited by 64 · cited 1×
“Similar attempts to spare implanted hardware have been previously reported in the literature [ 10 ].”
ResultSelf-citationDeep brain stimulation of the subthalamic nucleus in Parkinson's disease: long-term follow-up
Tavella, A., Bergamasco, B., Bosticco, E., Lanotte, M., Perozzo, P., Rizzone, M. G., Torre, E., & Lopiano, L. (2002) · Neurological Sciences · doi:10.1007/s100720200094 · Cited by 62
Deep brain stimulation of the subthalamic nucleus in Parkinson's disease
Iansek, R., Rosenfeld, J. V., & Huxham, F. E. (2002) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.2002.tb04700.x · Cited by 53
Subthalamic DBS replaces levodopa in Parkinson’s disease: Two-year follow-up
Lang, A. E., Kleiner‐Fisman, G., Saint‐Cyr, J. A., Miyasaki, J. M., & Lozano, A. M. (2003) · Neurology · doi:10.1212/wnl.60.1.154 · Cited by 42
Revision of deep brain stimulator for tremor
Schwalb, J. M., Riina, H. A., Skolnick, B. E., Jaggi, J. L., Simuni, T., & Baltuch, G. H. (2001) · Journal of neurosurgery · doi:10.3171/jns.2001.94.6.1010 · Cited by 37 · cited 1×
“It has been reported that electrode breakage is more likely if the connection is between the lead and the extension behind the ear rather than at the calvarium [9, 45 ].”
BackgroundSurgical and hardware complications in subthalamic nucleus deep brain stimulation
Chou, Y., Lin, S., Hsieh, W. A., Lin, S. H., Lee, C. C., Hsin, Y.-L., Yen, P.-S., Lee, C. W., Chiu, W., & Chen, S.-Y. (2007) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2006.02.016 · Cited by 37 · cited 4×
“Occasionally, patients undergoing DBS will encounter seizures [7, 12 , 19].”
BackgroundInfluentialTamma, F., Rampini, P. M., Egidi, M., Caputo, E., Locatelli, M., Pesenti, A., Chiesa, V., Ardolino, G., Foffani, G., Meda, B., et al. (2003) · Neurological Sciences · doi:10.1007/s100720300038 · Cited by 26
Treatment of early Parkinson's disease.
Pahwa, R., & Lyons, K. (2014) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000113 · Cited by 23
Treatment of Early Parkinson’s Disease
Simuni, T., Lyons, K. E., Pahwa, R., Hauser, R. A., Comella, C. L., Elmer, L. W., & Weintraub, D. A. (2009) · European Neurology · doi:10.1159/000197103 · Cited by 22
Deep brain stimulation as a functional scalpel
Broggi, G., Franzini, A., Tringali, G., Ferroli, P., Marras, C. E., Romito, L. M., & Maccagnano, E. (2007) · Springer eBooks · doi:10.1007/978-3-211-35205-2_2 · Cited by 17
Use of a single semilinear incision in Deep Brain Stimulation for movement disorders
Kouyialis, A. T., Boviatsis, E., Ziaka, D. S., & Sakas, D. E. (2007) · Acta Neurochirurgica · doi:10.1007/s00701-007-1141-1 · Cited by 9
Self-citationEDITORIAL A multidisciplinary approach to tremor
Aziz, T. Z., & Bain, P. G. (1996) · British Journal of Neurosurgery · doi:10.1080/02688699647041 · Cited by 9
Cited by
Fenoy, A. J., & Simpson, R. K. (2014) · Journal of Neurosurgery · doi:10.3171/2013.10.jns131225 · Cited by 449
Electrical brain stimulation for epilepsy
Fisher, R. S., & Velasco, A. L. (2014) · Nature Reviews Neurology · doi:10.1038/nrneurol.2014.59 · Cited by 402
Bullard, A. J., Hutchison, B. C., Lee, J., Chestek, C. A., & Patil, P. G. (2020) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.13069 · Cited by 65
Deep brain stimulation for psychiatric diseases: what are the risks?
Saleh, C., & Fontaine, D. (2015) · Current Psychiatry Reports · doi:10.1007/s11920-015-0565-1 · Cited by 30
Endovascular neuromodulation: safety profile and future directions
Raza, S. A., Opie, N. L., Morokoff, A., Sharma, R. P., Mitchell, P. J., & Oxley, T. J. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00351 · Cited by 29
Metadata
- Authors
- Boviatsis, E. J., Stavrinou, L. C., Themistocleous, M., Kouyialis, A. T., & Sakas, D. E.
- Venue
- Acta Neurochirurgica
- Published
- 2010-07-25
- Volume
- 152
- Issue
- 12
- Pages
- 2053-2062
- ISSN
- 0001-6268 (ISSN-L)
- 0942-0940
- OpenAlex
- W2062040062
- Cited by
- 192
- References
- 56
- FWCI
- 5.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.