A literature review and novel theoretical approach on the optical properties of whole blood
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Optical property measurements on blood are influenced by a large variety of factors of both physical and methodological origin. The aim of this review is to list these factors of influence and to provide the reader with optical property spectra (250–2,500 nm) for whole blood that can be used in the practice of biomedical optics (tabulated in the appendix). Hereto, we perform a critical examination and selection of the available optical property spectra of blood in literature, from which we compile average spectra for the absorption coefficient (μ(a)), scattering coefficient (μ(s)) and scattering anisotropy (g). From this, we calculate the reduced scattering coefficient (μ(s)′) and the effective attenuation coefficient (μ(eff)). In the compilation of μ(a) and μ(s), we incorporate the influences of absorption flattening and dependent scattering (i.e. spatial correlations between positions of red blood cells), respectively. For the influence of dependent scattering on μ(s), we present a novel, theoretically derived formula that can be used for practical rescaling of μ(s) to other haematocrits. Since the measurement of the scattering properties of blood has been proven to be challenging, we apply an alternative, theoretical approach to calculate spectra for μ(s) and g. Hereto, we combine Kramers–Kronig analysis with analytical scattering theory, extended with Percus–Yevick structure factors that take into account the effect of dependent scattering in whole blood. We argue that our calculated spectra may provide a better estimation for μ(s) and g (and hence μ(s)′ and μ(eff)) than the compiled spectra from literature for wavelengths between 300 and 600 nm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Light Scattering by Small Particles
van de Hulst, H. C. (1981) · CERN Document Server (European Organization for Nuclear Research) · Cited by 7,938
Optical Constants of Water in the 200-nm to 200-μm Wavelength Region
Hale, G. M., & Querry, M. R. (1973) · Applied Optics · doi:10.1364/ao.12.000555 · Cited by 4,468
Analysis of Classical Statistical Mechanics by Means of Collective Coordinates
Percus, J. K., & Yevick, G. J. (1958) · Physical Review · doi:10.1103/physrev.110.1 · Cited by 2,856
Exact Solution of the Percus-Yevick Integral Equation for Hard Spheres
Wertheim, M. S. (1963) · Physical Review Letters · doi:10.1103/physrevlett.10.321 · Cited by 1,783
Classification, Functions, and Clinical Relevance of Extracellular Vesicles
van der Pol, E., Böing, A. N., Harrison, P., Sturk, A., & Nieuwland, R. (2012) · Pharmacological Reviews · doi:10.1124/pr.112.005983 · Cited by 1,754
Optical Properties of Circulating Human Blood in the Wavelength Range 400–2500 nm
Roggan, A., Friebel, M., Dörschel, K., Hahn, A., & Müller, G. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429919 · Cited by 819
The flattering of the absorption spectrum of suspensions, as compared to that of solutions
Duyens, L. N. M. (1956) · Biochimica et Biophysica Acta · doi:10.1016/0006-3002(56)90380-8 · Cited by 718
Handbook of Optical Biomedical Diagnostics
Tuchin, V. V. (2002) · Medical Entomology and Zoology · Cited by 589
Kramers-Kronig Relations in Optical Materials Research
(2005) · Springer Series in Optical Sciences · doi:10.1007/b138913 · Cited by 555
Endovenous therapies of lower extremity varicosities: A meta-analysis
van den Bos, R., Arends, L., Kockaert, M., Neumann, M., & Nijsten, T. (2009) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2008.06.030 · Cited by 530
Cited by
Sommermeyer, D., Hudecek, M., Kosasih, P. L., Gogishvili, T., Maloney, D. G., Turtle, C. J., & Riddell, S. R. (2016) · Leukemia · doi:10.1038/leu.2015.247 · Cited by 867
Yi, J., Liu, W., Chen, S., Backman, V., Sheibani, N., Sorenson, C. M., Fawzi, A. A., Linsenmeier, R. A., & Zhang, H. F. (2015) · Light: Science & Applications · doi:10.1038/lsa.2015.107 · Cited by 177
Visible-light optical coherence tomography: a review
Shu, X., Beckmann, L., & Zhang, H. F. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.12.121707 · Cited by 173
“W relates to hematocrit of blood, H , as 77 ;temp:intralink-;e013;326;463 Both absorption and scattering coefficient spectra are available from the literature 77 and the hematocrit value does not have large variation and can be measured by routine clinical practice.”
BackgroundNew insights into the origin of remote PPG signals in visible light and infrared
Moço, A. V., Stuijk, S., & de Haan, G. (2018) · Scientific Reports · doi:10.1038/s41598-018-26068-2 · Cited by 168
“57 , the diastolic absorption coefficient of the total tissue was given by Systole is modeled as fractional pulsatile increases, p , of arterial blood in pulsating layers.”
Multiphoton fluorescence microscopy for in vivo imaging
Xu, C., Nedergaard, M., Fowell, D. J., Friedl, P., & Ji, N. (2024) · Cell · doi:10.1016/j.cell.2024.07.036 · Cited by 165
Shimojo, Y., Nishimura, T., Hazama, H., Ozawa, T., & Awazu, K. (2020) · Journal of Biomedical Optics · doi:10.1117/1.jbo.25.4.045002 · Cited by 132
Chatterjee, S., & Kyriacou, P. A. (2019) · Sensors · doi:10.3390/s19040789 · Cited by 86
Near‐IR Photochemistry for Biology: Exploiting the Optical Window of Tissue
Alabugin, A. (2019) · Photochemistry and Photobiology · doi:10.1111/php.13068 · Cited by 70
Moço, A., & Verkruysse, W. (2021) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-019-00449-y · Cited by 55
The role of tissue fluorescence in in vivo optical bioimaging
Lifante, J., Shen, Y., Ximendes, E., Martín Rodríguez, E., & Ortgies, D. H. (2020) · Journal of Applied Physics · doi:10.1063/5.0021854 · Cited by 43
An Artist-Friendly Albedo Approximation for Transmissive Materials
Kryzhanovskyi, A. (2026) · Proceedings of the Special Interest Group on Computer Graphics and Interactive Techniques Conference Talks · doi:10.1145/3799818.3812065
Metadata
- Authors
- Bosschaart, N., Edelman, G. J., Aalders, M. C. G., van Leeuwen, T. G., & Faber, D. J.
- Venue
- Lasers in Medical Science
- Published
- 2013-10-12
- Volume
- 29
- Issue
- 2
- Pages
- 453-479
- ISSN
- 0268-8921 (ISSN-L)
- 1435-604X
- OpenAlex
- W2028558873
- Cited by
- 459
- References
- 30
- FWCI
- 13.07
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.