Pulse oximetry based on photoplethysmography imaging with red and green light: Calibratability and challenges
Abstract
Remotely measuring the arterial blood oxygen saturation (SpO 2) in visible light (Vis) involves different probing depths, which may compromise calibratibility. This paper assesses the feasibility of calibrating camera-based SpO 2 (SpO 2,cam) using red and green light. Camera-based photoplethysmographic (PPG) signals were measured at 46 healthy adults at center wavelengths of 580 nm (green), 675 nm (red), and 840 nm (near-infrared; NIR). Subjects had their faces recorded during normoxia and hypoxia and under gradual cooling. SpO 2,cam estimates in Vis were based on the normalized ratio of camera-based PPG amplitudes in red over green light (RoG). SpO 2,cam in Vis was validated against contact SpO 2 (reference) and compared with SpO 2,cam estimated using red-NIR wavelengths. An RoG-based calibration curve for SpO 2 was determined based on data with a SpO 2 range of 85-100%. We found an [Formula: see text] error of 2.9% (higher than the [Formula: see text] for SpO 2,cam in red-NIR). Additional measurements on normoxic subjects under temperature cooling (from [Formula: see text] to [Formula: see text]) evidenced a significant bias of - 1.7, CI [- 2.7, - 0.7]%. It was also noted that SpO[Formula: see text] estimated at the cheeks was significantly biased (- 3.6, CI [- 5.7, - 1.5]%) with respect to forehead estimations. Under controlled conditions, SpO[Formula: see text] can be calibrated with red and green light but the accuracy is less than that of SpO[Formula: see text] estimated in the usual red-NIR window.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Other subjective scales were employed in 13 studies (35.14%).
“and other subjective scales were employed in 13 studies (35.14%) [30,42,43,44,45,50,52,56,72,78,80,87,88].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [72]
A recent study on 46 subjects at center wavelengths of 840 nm, 675 nm, and 580 nm found significant bias at lower temperatures when calibrating a camera-based SpO2 oximeter using red and green light under normoxic and hypoxic conditions.
“A recent study was performed on 46 subjects at center wavelengths of 840 nm (near-infrared), 675 nm (red), and 580 nm (green) to evaluate the feasibility of calibrating a camera-based SpO2 oximeter using red and green light on data under normoxic and hypoxic conditions found significant bias at lower temperatures [72].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [72]
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · see citing works
Robust regression using iteratively reweighted least-squares.
Holland, P. W., & Welsch, R. E. (1977) · Communications in Statistics - Theory and Methods · doi:10.1080/03610927708827533 · Cited by 2,115 · see citing works
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,728 · see citing works
Robust pulse rate from chrominance-based rPPG
de Haan, G., & Jeanne, V. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2266196 · Cited by 1,378 · see citing works
The enigma of Mayer waves: facts and models.
JULIEN, C. (2006) · Cardiovascular Research · doi:10.1016/j.cardiores.2005.11.008 · Cited by 670 · see citing works
Retinopathy of prematurity: a review of risk factors and their clinical significance
Kim, S. J., Port, A. D., Swan, R., Campbell, J. P., Chan, R. V. P., & Chiang, M. F. (2018) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2018.04.002 · Cited by 582 · see citing works
A literature review and novel theoretical approach on the optical properties of whole blood
Bosschaart, N., Edelman, G. J., Aalders, M. C. G., van Leeuwen, T. G. J. M., & Faber, D. J. (2013) · Lasers in Medical Science · doi:10.1007/s10103-013-1446-7 · Cited by 463 · see citing works
Pulse oximetry: Analysis of theory, technology, and practice
Wukitsch, M. W., Petterson, M. T., Tobler, D. R., & Pologe, J. A. (1988) · Journal of Clinical Monitoring and Computing · doi:10.1007/bf01617328 · Cited by 305 · see citing works
Wieringa, F. P., Mastik, F., & van der Steen, A. F. W. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-5763-2 · Cited by 284 · see citing works
Pulse oximetry: its invention, theory, and future
Aoyagi, T. (2003) · Journal of Anesthesia · doi:10.1007/s00540-003-0192-6 · Cited by 263 · see citing works
New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoring
van Gastel, M., Stuijk, S., & de Haan, G. (2016) · Scientific Reports · doi:10.1038/srep38609 · Cited by 253 · see citing works
Photoelectric Plethysmography of the Fingers and Toes in Man
Hertzman, A. B. (1937) · Experimental Biology and Medicine · doi:10.3181/00379727-37-9630 · Cited by 217 · see citing works
Integrating a Robust Option into a Multiple Regression Computing Environment
DuMouchel, W., & O’Brien, F. (1991) · The IMA volumes in mathematics and its applications · doi:10.1007/978-1-4613-9154-8_3 · Cited by 185 · see citing works
New insights into the origin of remote PPG signals in visible light and infrared
Moço, A., Stuijk, S., & de Haan, G. (2018) · Scientific Reports · doi:10.1038/s41598-018-26068-2 · Cited by 170 · see citing works
Non-contact measurement of oxygen saturation with an RGB camera
Guazzi, A., Villarroel, M., Jorge, J., Daly, J., Frise, M. C., Robbins, P. A., & Tarassenko, L. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.003320 · Cited by 151 · see citing works
Photoplethysmographic imaging of high spatial resolution
Kamshilin, A. A., Miridonov, S. V., Teplov, V., Saarenheimo, R., & Nippolainen, E. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.000996 · Cited by 142 · see citing works
Unobtrusive Vital Sign Monitoring in Automotive Environments—A Review
Leonhardt, S. K., Leicht, L., & Teichmann, D. (2018) · Sensors · doi:10.3390/s18093080 · Cited by 135 · see citing works
Calibration of Contactless Pulse Oximetry
Verkruysse, W., Bartula, M., Bresch, E., Rocque, M., Meftah, M., & Kirenko, I. O. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001381 · Cited by 92 · see citing works
Stroke volume response during exercise measured by acetylene uptake and MRI
Groepenhoff, H., Holverda, S., Marcus, J. T., Postmus, P. E., Boonstra, A., & Noordegraaf, A. V. (2006) · Physiological Measurement · doi:10.1088/0967-3334/28/1/001 · Cited by 88 · see citing works
Design and Development of a Modular, Multichannel Photoplethysmography System
Budidha, K., Rybynok, V., & Kyriacou, P. A. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2810643 · Cited by 49 · see citing works
Hu, S., Azorin-Peris, V., Echiadis, A., Zheng, J., & Shi, P. A. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5334505 · Cited by 40 · see citing works
Design and development of a novel multi-channel photoplethysmographic research system
Rybynok, V. O., May, J. M., Budidha, K., & Kyriacou, P. A. (2013) · doi:10.1109/pht.2013.6461336 · Cited by 32 · see citing works
Posture effects on the calibratability of remote pulse oximetry in visible light
Moço, A., Stuijk, S., & de Haan, G. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab051a · Cited by 6 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
A review of wearable and unobtrusive sensing technologies for chronic disease management
Guo, Y., Liu, X., Peng, S., Jiang, X., Xu, K., Chen, C., Wang, Z., Dai, C., & Chen, W. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.104163 · Cited by 137 · see citing works
Cabanas, A. M., Fuentes-Guajardo, M., Latorre, K., León, D., & Martín-Escudero, P. (2022) · Sensors · doi:10.3390/s22093402 · Cited by 124 · see citing works
An Overview of the Sensors for Heart Rate Monitoring Used in Extramural Applications
Galli, A., Montree, R. J. H., Que, S., Peri, E., & Vullings, R. (2022) · Sensors · doi:10.3390/s22114035 · Cited by 79 · see citing works
Advances in Biointegrated Wearable and Implantable Optoelectronic Devices for Cardiac Healthcare
Li, C., Bian, Y., Zhao, Z., Liu, Y., & Guo, Y. (2024) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0172 · Cited by 69 · see citing works
Non-Contact SpO2 Prediction System Based on a Digital Camera
Al-Naji, A., Khalid, G. A., Mahdi, J. F., & Chahl, J. (2021) · Applied Sciences · doi:10.3390/app11094255 · Cited by 61 · see citing works
Yu, X., Laurentius, T., Bollheimer, C., Leonhardt, S. K., & Antink, C. H. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3018394 · Cited by 60 · see citing works
Multimodal Corpus Design for Audio-Visual Speech Recognition in Vehicle Cabin
Kashevnik, A. M., Lashkov, I., Axyonov, A., Ivanko, D., Ryumin, D., Kolchin, A., & Karpov, A. A. (2021) · IEEE Access · doi:10.1109/access.2021.3062752 · Cited by 38 · see citing works
Gupta, A. R., Ravelo-García, A. G., & Morgado‐Dias, F. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.106771 · Cited by 38 · see citing works
Chen, W., Yi, Z., Lim, L. J. R., Lim, R. Q. R., Zhang, A., Qian, Z., Huang, J., He, J., & Лю, Б. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1420100 · Cited by 39 · see citing works
Hu, M., Wu, X., Wang, X., Xing, Y. T., An, N., & Shi, P. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.104487 · Cited by 34 · see citing works
Stogiannopoulos, T., Cheimariotis, G., & Mitianoudis, N. (2023) · Information · doi:10.3390/info14060301 · Cited by 28 · see citing works
LGI-rPPG-Net: A shallow encoder-decoder model for rPPG signal estimation from facial video streams
Chowdhury, M. H., Chowdhury, M. E. H., Reaz, M. B. I., Ali, S. H. M., Rakhtala, S. M., Murugappan, M., Mahmud, S., Shuzan, M. N. I., Bakar, A. A. A., Shapiai, M. I., et al. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105687 · Cited by 27 · see citing works
Bousefsaf, F., Djeldjli, D., Ouzar, Y., Maaoui, C., & Pruski, A. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104860 · Cited by 26 · see citing works
Zaunseder, S., Vehkaoja, A. T., Fleischhauer, V., & Antink, C. H. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.103538 · Cited by 26 · see citing works
Motion-Robust Atrial Fibrillation Detection Based on Remote-Photoplethysmography
Wu, B., Wu, B.-J., Cheng, S.-E., Sun, Y., & Chung, M.-L. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3172705 · Cited by 27 · see citing works
Allado, E., Poussel, M., Moussu, A., Saunier, V., Bernard, Y., Albuisson, E., & Chenuel, B. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-047896 · Cited by 22 · see citing works
Notch RGB-camera based SpO 2 estimation: a clinical trial in neonatal intensive care unit
Ye, Y., Pan, L., Yu, D., Gu, D., Lu, H., & Wang, W. (2023) · Biomedical Optics Express · doi:10.1364/boe.510925 · Cited by 21 · see citing works
ROSE-Net: Leveraging remote photoplethysmography to estimate oxygen saturation using deep learning
Chowdhury, M. H., Reaz, M. B. I., Ali, S. H. M., Khan, M. S., & Chowdhury, M. E. H. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.107105 · Cited by 20 · see citing works
Peripheral Oxygen Saturation Measurement Using an RGB Camera
Wu, B.-J., Wu, B., Dong, Y.-C., Lin, H., & Li, P. W. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3284196 · Cited by 20 · see citing works
Cabanas, A. M., Saez, N. V., Caiconte, P. C., Martín-Escudero, P., Pagán, J., Jiménez-Herranz, E., & Ayala, J. L. (2024) · Bioengineering · doi:10.3390/bioengineering11111061 · Cited by 18 · see citing works
Park, Y.-R., Shin, Y.-K., & Eom, J. B. (2023) · Biomedical Engineering Letters · doi:10.1007/s13534-023-00275-x · Cited by 18 · see citing works
Noncontact Sensing of Contagion
Khanam, F.-T.-Z., Chahl, L. A., Chahl, J. S., Al‐Naji, A., Perera, A. G., Wang, D., Lee, Y. H., Ogunwa, T., Teague, S., Nguyen, T. X. B., et al. (2021) · Journal of Imaging · doi:10.3390/jimaging7020028 · Cited by 18 · see citing works
Contactless SpO 2 with an RGB camera: experimental proof of calibrated SpO 2
van Gastel, M., & Verkruysse, W. (2022) · Biomedical Optics Express · doi:10.1364/boe.471332 · Cited by 16 · see citing works
Thermal Cameras for Continuous and Contactless Respiration Monitoring
Alves, R. B. A., van Meulen, F., Overeem, S., Zinger, S., & Stuijk, S. (2024) · Sensors · doi:10.3390/s24248118 · Cited by 16 · see citing works
Photoplethysmography in oxygenation and blood volume measurements
Abay, T. Y., & Kyriacou, P. A. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823374-0.00003-7 · Cited by 16 · see citing works
A survey of blood oxygen saturation assessment from video
Wuyart, A., Vuillaume, L. A., Maaoui, C., & Bousefsaf, F. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.108069 · Cited by 11 · see citing works
Innovative approaches in imaging photoplethysmography for remote blood oxygen monitoring
Zhu, S., Liu, S., Jing, X., Yang, Y., & She, C. (2024) · Scientific Reports · doi:10.1038/s41598-024-70192-1 · Cited by 11 · see citing works
A State‐Of‐The‐Art Survey of Remote Photoplethysmography for Contactless Health Parameters Sensing
Sakib, S., Hasan, Z., & Roy, N. (2025) · Wiley Interdisciplinary Reviews Data Mining and Knowledge Discovery · doi:10.1002/widm.70039 · Cited by 11 · see citing works
Quasi Real-time Contactless Physiological Sensing Using Consumer-Grade Cameras
Rivest‐Hénault, D., Pagiatakis, C., Bernhardt, R., Vaughan, T., Falardeau, B., Smith, M. S. D., & Jiang, D. (2021) · IEEE International Conference on Healthcare Informatics (ICHI) · doi:10.1109/ichi52183.2021.00038 · Cited by 8 · see citing works
Using Contactless Facial Image Recognition Technology to Detect Blood Oxygen Saturation
Cheng, J.-C., Pan, T.-S., Hsiao, W.-C., Lin, W.-H., Liu, Y.-L., Su, T., & Wang, S. (2023) · Bioengineering · doi:10.3390/bioengineering10050524 · Cited by 10 · see citing works
Normalization is All You Need: Robust Full-Range Contactless SpO2 Estimation Across Users
Shao, Q., Zhu, L., Ahmed, M. Y., Vatanparvar, K., Gwak, M., Rashid, N., Bae, J., Kuang, J., & Gao, A. J. (2024) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp48485.2024.10446435 · Cited by 9 · see citing works
Arefin, K. Z., Alam, K. S., Mamun, S. M., Sabith, N. U. S., Rabbani, M., Sridevi, P., & Ahamed, S. I. (2025) · Smart Health · doi:10.1016/j.smhl.2025.100542 · Cited by 8 · see citing works
Photoplethysmographic Imaging of Hemodynamics and Two-Dimensional Oximetry
Volkov, I. Y., Сагайдачный, А. А., & Фомин, А. В. (2022) · Optics and Spectroscopy · doi:10.1134/s0030400x22080057 · Cited by 7 · see citing works
Influential Factors in rPPG: Insights from a Diverse and Inclusive Empirical Study
Rivest‐Hénault, D., Proulx, C., Ho, K., Jafari, N., Yakubu, T., Torres, S., Lim, M., Pecora, L., Bernhardt, R., Auer, S., et al. (2024) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn63547.2024.10780670 · Cited by 5 · see citing works
Petersen, A. G., Kjær, M. R., & Sørensen, H. B. D. (2023) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc40787.2023.10340995 · Cited by 4 · see citing works
Pulse Rate Guided Oxygen Saturation Monitoring Using a Wearable Armband Sensor
Huang, N., Bian, D., Zhou, M., Mehta, P., Shah, M., Rajput, K. S., Majmudar, M. D., & Selvaraj, N. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871461 · Cited by 4 · see citing works
Red Blood Cells’ Area Deformation as the Origin of the Photoplethysmography Signal
Evdochim, L., Chiriac, E., Avram, M., Dobrescu, L., Dobrescu, D., Stanciu, S., & Halichidis, S. (2023) · Sensors · doi:10.3390/s23239515 · Cited by 4 · see citing works
Mathematical Modeling and Simulation of Photoplethysmography
Adhikari, L., & Pahuja, S. K. (2020) · International Conference on Communications and Signal Processing (ICCSP) · doi:10.1109/iccsp48568.2020.9182070 · Cited by 4 · see citing works
PHASE: Physiological Dynamics-Based Attention for SpO$$_2$$ Estimation
Ahmad, S., Mukherjee, S., Chanda, S., Shivakumara, P., Pal, U., & Pedersen, M. (2025) · Lecture notes in computer science · doi:10.1007/978-3-031-95911-0_3 · Cited by 3 · see citing works
Recent advancements in deep learning-based remote photoplethysmography methods
Gupta, A. R., Ravelo-García, A. G., & Morgado‐Dias, F. (2024) · Elsevier eBooks · doi:10.1016/b978-0-44-313233-9.00012-6 · Cited by 3 · see citing works
Future of magnetic sensors applications in early prediction of cardiac health status
Khan, M. S. Z., Khan, S. U., Alrumaihi, F., Alwanian, W. M., Alharbi, H. O., Alfifi, S. M., Makki, L. K., Sahli, M., Alnafjan, A. A., & Jackson, M. C. (2025) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2025.103022 · Cited by 3 · see citing works
Towards Real-Time Oxygen Sensing: From Nanomaterials to Plasma
Johny, V., Chinmaya, K., Muhammed Nihal, C. V., Kurian, V., Rao, G. M., Ghosh, M., & Ghosh, S. (2022) · Frontiers in Sensors · doi:10.3389/fsens.2021.826403 · Cited by 2 · see citing works
Borik, Š., Wu, H., Shelley, K. H., & Alian, A. A. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106574 · Cited by 2 · see citing works
Videocapillaroscopic monitoring of microcirculation in rats during photodynamic therapy
Guryleva, A. V., Machikhin, A. S., Гришачева, Т. Г., & Петрищев, Н. Н. (2023) · Biomedical Photonics · doi:10.24931/2413-9432-2023-12-2-16-23 · Cited by 2 · see citing works
Koteska, B., Ackovska, N., Bogdanova, A. M., Kostoska, M., Sidorenko, M., Lehocki, F., & Trajkovik, V. (2024) · Biomedical Engineering Applications Basis and Communications · doi:10.4015/s1016237224300049 · Cited by 1 · see citing works
Measurement of Blood Oxygen based on Remote-Photoplethysmography
Lin, H., Dong, Y.-C., Wu, B.-J., & Wu, B. (2022) · International Conference on System Science and Engineering · doi:10.1109/icsse55923.2022.9948229 · Cited by 1 · see citing works
Rosa, A. D. F. G., & Perdigão, S. F. (2024) · IEEE Instrumentation & Measurement Magazine · doi:10.1109/mim.2024.10473015 · Cited by 1 · see citing works
What Remote PPG Oximetry Tells Us about Pulsatile Volume?
Saiko, G. (2024) · Biomedicines · doi:10.3390/biomedicines12081784 · Cited by 1 · see citing works
Towards Collecting Big Data for Remote Photoplethysmography
Kalinin, K. B., Mironenko, Y., Kopeliovich, M. V., & Petrushan, M. V. (2021) · Lecture notes in networks and systems · doi:10.1007/978-3-030-80129-8_6
Impact of Body Position on Imaging Ballistocardiographic Signals
Woyczyk, A., & Zaunseder, S. (2023) · International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC) · doi:10.5220/0011659900003414
Postoperative management of patients after bilateral tonsillectomy
Toldanov, A. V., Николаевна, Н. Г., Валерьевич, С. М., Kulikova, E. D., Guryleva, A. V., Machikhin, A. S., & Свистушкин, В. М. (2025) · Consilium Medicum · doi:10.26442/20751753.2025.9.203486
Shu, H., Ye, Y. P., Pan, L., Wang, G., Huang, J., & Wang, W. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3654747
Jiao, X., Gao, Q., Qi, L., Xu, L., & Qian, W. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3664375
FRETS: Frequency-Enhanced Residual Transformer System for $$\text {SpO}_2$$ Estimation
Mukherjee, S., Ahmad, S., Padhy, R. P., Chanda, S., & Pal, U. (2026) · Lecture notes in computer science · doi:10.1007/978-3-032-31404-8_32
Bomotano, J. R., Gonzaga, R. A., Rosendo, R. L., Calimpusan, R. C. O., & Dellosa, J. T. (2026) · International Artificial Intelligence and Data Processing Symposium (IDAP) · doi:10.1109/idap71869.2026.11728024
- Authors
- Moço, A., & Verkruysse, W.
- Affiliations
- Eindhoven University of Technology (NL)
- Corresponding author
- Moço, Andreia
- Venue
- Journal of Clinical Monitoring and Computing
- Published
- 2020-01-01
- Volume
- 35
- Issue
- 1
- Pages
- 123-133
- ISSN
- 1387-1307 (ISSN-L)
- 1573-2614
- OpenAlex
- W2998583602
- Cited by
- 55
- References
- 23
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 13 · 2023: 10 · 2022: 11 · 2021: 8 · 2020: 3
- FWCI
- 2.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Clinical Monitoring and Computing (publishedVersion)
- PubMed (publishedVersion)
- TU/e Research Portal (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
- Keywords
- pulse oximetry, imaging photoplethysmography, arterial oxygen saturation, visible light, red and green light, calibration, hypoxia, facial measurements
- MeSH terms
- Adult, Hypoxia, Humans, Light, Oximetry, Oxygen, Photoplethysmography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review