The role of fabric in the quasi-static compressive mechanical properties of human trabecular bone from various anatomical locations
The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Osteoporosis leads to an increased risk of bone fracture. While bone density and architecture can be assessed in vivo with increasing accuracy using CT and MRI, their relationship with the critical mechanical properties at various anatomical sites remain unclear. The objective of this study was to quantify the quasi-static compressive mechanical properties of human trabecular bone among different skeletal sites and compare their relationships with bone volume fraction and a measure of microstructural anisotropy called fabric. Over 600 trabecular bone samples from six skeletal sites were assessed by microCT and tested in uniaxial compression. Bone volume fraction correlated positively with elastic modulus, yield stress, ultimate stress, and the relationships depended strongly on skeletal site. The account of fabric improved these correlations substantially, especially when the data of all sites were pooled together, but the fabric-mechanical property relationships remained somewhat distinct among the anatomical sites. The study confirms that, beyond volume fraction, fabric plays an important role in determining the mechanical properties of trabecular bone and should be exploited in mechanical analysis of clinically relevant sites of the human skeleton.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“More recent research has indicated that the fabric–mechanical property relationships may depend on anatomic site (130).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [130]
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209 · cited 1×
“A more recent study reported that there is no single, universal relationship between elastic properties and density across anatomic site for on-axis loading ( Morgan et al. 2003 ).”
BackgroundZysset, P. K., Edward Guo, X., Edward Hoffler, C., Moore, K. E., & Goldstein, S. A. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00111-6 · Cited by 1,006
Self-citationElastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924
The relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705 · cited 1×
“Morgan and Keaveny (2001) measured yield strains inthesamerangeatfouranatomicallocationsandfound significant differences between sites with the lowest value at the femoral trochanter.”
BackgroundCharacterization of microstructural anisotropy in orthotropic materials using a second rank tensor
Harrigan, T. P., & Mann, R. W. (1984) · Journal of Materials Science · doi:10.1007/bf00540446 · Cited by 603
The relationship between the elasticity tensor and the fabric tensor
Cowin, S. C. (1985) · Mechanics of Materials · doi:10.1016/0167-6636(85)90012-2 · Cited by 570
Research works printed but not linked: 3
- Curnier A (2004) Mécanique des Solides Déformables. Presses Polytechniques et Universitaires Romandes, Lausanne
- Kabel J, van Rietbergen B, Odgaard A, Huiskes R (1997) Fabric and volume fraction can accurately predict mechanical properties for a wide range of trabecular architectures. In: Transactions of the 43rd annual meeting of the ORS San Francisco, vol 2, p 800
- Zysset PhK, Curnier A (1995) An alternative model for anisotropic elasticity of trabecular bone. In: Bioengineering conference of the ASME, Beaver Creek, Colorado, p 359
Cited by
Bone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
“More recent research has indicated that the fabric–mechanical property relationships may depend on anatomic site (130).”
Maquer, G., Musy, S. N., Wandel, J., Gross, T., & Zysset, P. K. (2015) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2437 · Cited by 199
“Alternatively, accounting for trabecular fabric anisotropy enhances the high correlations between BV/TV and stiffness.((22)) In fact, with only these two variables (BV/TV and fabric anisotropy), morphology-elasticity relationships can already explain more than 95% of the variation in elastic properties of trabecular b…”
BackgroundSelf-citationDall’Ara, E., Pahr, D., Varga, P., Kainberger, F., & Zysset, P. (2012) · Osteoporosis International · doi:10.1007/s00198-011-1568-3 · Cited by 181
“Experimental studies have recently shown that bone strength is affected both by BMD, that remain the primary factor, and by bone quality [17–20], that includes several parameters like cortical thickness and porosity [21–23], trabecular bone morphology [24–27], microdamage [20, 28, 29], and properties of the matrix [30…”
BackgroundSelf-citationMulti-axial mechanical properties of human trabecular bone
Rincón-Kohli, L., & Zysset, P. K. (2009) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-008-0128-z · Cited by 177
Self-citationAdvances in osteoporosis imaging
Bauer, J. S., & Link, T. M. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2008.04.064 · Cited by 179
“[78] Matsuura M, Eckstein F, Lochmüller EM, Zysset PK.”
Standardizing compression testing for measuring the stiffness of human bone
Zhao, S., Arnold, M. C. A., Ma, S., Abel, R. L., Cobb, J. P., Hansen, U. N., & Boughton, O. R. (2018) · Bone and Joint Research · doi:10.1302/2046-3758.78.bjr-2018-0025.r1 · Cited by 151
Density and mechanical properties of vertebral trabecular bone—A review
Öhman‐Mägi, C., Holub, O., Wu, D., Hall, R. M., & Persson, C. (2021) · JOR Spine · doi:10.1002/jsp2.1176 · Cited by 135
“…(inferior-superior) direction, ML (mediolateral) direction, or AP (anteroposterior) direction. f NS is short for not significant. g ρ is the volume fraction and m = 0.00069. structure not only vary between anatomical sites, 34,35,59-61 but also between different regions in the same anatomical site.”
BackgroundInfluentialSensini, A., Massafra, G., Gotti, C., Zucchelli, A., & Cristofolini, L. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.645544 · Cited by 95
Damage accumulation in vertebral trabecular bone depends on loading mode and direction
Wolfram, U., Wilke, H., & Zysset, P. K. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.01.018 · Cited by 84
Self-citationSchwiedrzik, J. J., Wolfram, U., & Zysset, P. K. (2013) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-013-0472-5 · Cited by 77
“In the particular case of the Zysset– Curnier model (Zysset and Curnier 1995), the influence of these two factors on its homogenized mechanical properties is governed by two exponents p and q that need to be determined experimentally (Matsuura et al. 2008; Rincón-Kohli and Zysset 2009; Zysset and Rincón 2006; Wolfram…”
BackgroundSelf-citationAnisotropy of the fatigue behaviour of cancellous bone
Dendorfer, S., Maier, H. J., Taylor, D., & Hammer, J. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.037 · Cited by 76
Empirical relationships between bone density and ultimate strength: A literature review
Fleps, I., Bahaloo, H., Zysset, P. K., Ferguson, S. J., Pálsson, H., & Helgason, B. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103866 · Cited by 85
Self-citationX-ray vector radiography for bone micro-architecture diagnostics
Potdevin, G., Malecki, A., Biernath, T., Bech, M., Jensen, T. H., Feidenhans’l, R., Zanette, I., Weitkamp, T., Kenntner, J., Mohr, J., et al. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/11/3451 · Cited by 76
Fabric-based Tsai–Wu yield criteria for vertebral trabecular bone in stress and strain space
Wolfram, U., Gross, T. J., Pahr, D. H., Schwiedrzik, J. J., Wilke, H., & Zysset, P. K. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.07.005 · Cited by 78
Self-citationFollet, H., Viguet‐Carrin, S., Burt‐Pichat, B., Dépalle, B., Bala, Y., Gineyts, É., Munoz, F., ARLOT, M. E., Boivin, G., Chapurlat, R. D., et al. (2010) · Journal of Orthopaedic Research® · doi:10.1002/jor.21275 · Cited by 90
“Several studies have shown that the mechanical properties of trabecular bone are influenced by bone volume fraction (BV/TV) and microarchitecture.(1,2) However, additional factors, such as degree of mineralization, preexisting microdamage, and collagen cross-link profile may also play a role, yet the contribution of t…”
BackgroundChevalier, Y., Pahr, D. H., & Zysset, P. K. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.3212097 · Cited by 79
Self-citationRettler, E., Hoeppener, S., Sigusch, B. W., & Schubert, U. S. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb20120a · Cited by 68
Gross, T. J., Pahr, D. H., Peyrin, F., & Zysset, P. K. (2012) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2011.581236 · Cited by 67
“Experimental tests and micromechanical finite element (mFE) simulations are commonly used to investigate the stiffness and strength of cancellous bone specimens (van Rietbergen et al. 1995; Niebur et al. 2000; Keaveny et al. 2001; Matsuura et al. 2008; Rincon-Kohli and Zysset 2009).”
BackgroundSelf-citationMusy, S. N., Maquer, G., Panyasantisuk, J., Wandel, J., & Zysset, P. K. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.10.004 · Cited by 63
Self-citationSchwiedrzik, J. J., Gross, T., Bina, M., Pretterklieber, M. L., Zysset, P. K., & Pahr, D. H. (2015) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2739 · Cited by 64
Self-citationVolume to density relation in adult human bone tissue
Tassani, S., Öhman‐Mägi, C., Baruffaldi, F., Baleani, M., & Viceconti, M. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.08.032 · Cited by 55
Fabric dependence of wave propagation in anisotropic porous media
Cowin, S. C., & Cardoso, L. (2010) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-010-0217-7 · Cited by 53
“Fabric is a quantitative stereological measure of the degree of structural anisotropy in the pore architecture of a porous medium (Hilliard 1967; Whitehouse 1974a; Whitehouse and Dyson 1974b; Oda 1976; Oda et al. 1980, 1985; Cowin and Satake 1978; Satake 1982; Kanatani 1983, 1984a,b, 1985; Harrigan and Mann 1984; Odga…”
A nonlocal constitutive model for trabecular bone softening in compression
Charlebois, M., Jirásek, M., & Zysset, P. K. (2010) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-010-0200-3 · Cited by 61
“In the literature, data for elasticity and yield criterion are already available (Matsuura et al. 2008; Rincón-Kohli and Zysset 2009; Chevalier et al. 2008a), while the hardening and softening parameters remain to be determined and thus require an experimental study.”
BackgroundSelf-citationMoesen, M., Cardoso, L., & Cowin, S. C. (2012) · Mechanics of Materials · doi:10.1016/j.mechmat.2012.07.004 · Cited by 49
“The work of these authors, and (Odgaard et al., 1997; van Rietbergen et al., 1998; van Rietbergen et al., 1996; Matsuura et al., 2008) others, has shown that the fabric tensor is a good measure of the pore structure anisotropy in cancellous bone tissue (Cowin, 1997).”
BackgroundHaïat, G., Padilla, F. R., Svrcekova, M., Chevalier, Y., Pahr, D. H., Peyrin, F., Laugier, P., & Zysset, P. K. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.06.008 · Cited by 51
Self-citationTassani, S., Öhman‐Mägi, C., Baleani, M., Baruffaldi, F., & Viceconti, M. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.11.034 · Cited by 54
“…have shown that the loading direction and the micro-architecture anisotropy, together with BV/TV, are the most relevant parameters for the description of the mechanical behaviour of the cancellous bone tissue (Turner et al., 1990; Goulet et al., 1994; Matsuura et al., 2007; Öhman et al., 2007).”
BackgroundMethodResultInfluentialLevrero-Florencio, F., Margetts, L., Sales, E., Xie, S., Manda, K., & Pankaj, P. (2016) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2016.04.008 · Cited by 46
“Multilinear regressions suggest that uniaxial yield strains are not correlated with BV/TV and fabric (Matsuura et al., 2008; Morgan and Keaveny, 2001; Panyasantisuk et al., 2015).”
InfluentialMicroindentation can discriminate between damaged and intact human bone tissue
Dall’Ara, E., Schmidt, R., & Zysset, P. K. (2012) · Bone · doi:10.1016/j.bone.2012.01.002 · Cited by 55
“[6] M.”
BackgroundSelf-citationEberle, S., Göttlinger, M., & Augat, P. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.06.035 · Cited by 52
The Role of Fabric in the Large Strain Compressive Behavior of Human Trabecular Bone
Charlebois, M., Pretterklieber, M. L., & Zysset, P. K. (2010) · Journal of Biomechanical Engineering · doi:10.1115/1.4001361 · Cited by 41
Self-citationEffect of boundary conditions on yield properties of human femoral trabecular bone
Panyasantisuk, J., Pahr, D. H., & Zysset, P. K. (2015) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-015-0741-6 · Cited by 46
“Currently available experimental results on human bone include only uniaxial, torsion and a few combined load cases (Morgan and Keaveny 2001; Rincón-Kohli and Zysset 2008; Matsuura et al. 2008).”
BackgroundSelf-citationHazrati, J., Ito, K., & van Rietbergen, B. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.08.022 · Cited by 44
“First, most bone morphology–stiffness relationships have already been well validated by comparing elastic properties calculated from the morphology parameters with those measured in experiments or from micro-FE analyses of the same specimens (Matsuura et al., 2008; Rincon-Kohli and Zysset, 2009).”
BackgroundRole of structural anisotropy of biological tissues in poroelastic wave propagation
Cardoso, L., & Cowin, S. C. (2011) · Mechanics of Materials · doi:10.1016/j.mechmat.2011.08.007 · Cited by 40
“…of structural anisotropy in the pore architecture of a porous medium (Hilliard, 1967; Whitehouse 1974a; Whitehouse and Dyson, 1974b; Cowin and Satake, 1978; Satake, 1982; Kanatani, 1983, 1984a&b, 1985; Harrigan and Mann, 1984; Odgaard, 1997a, 2001; Odgaard et al., 1997b, Matsuura et al., 2008).”
BackgroundLarsson, D., Luisier, B., Kersh, M. E., Dall’Ara, E., Zysset, P. K., Pandy, M. G., & Pahr, D. H. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-0983-y · Cited by 43
Self-citationMixture theory-based poroelasticity as a model of interstitial tissue growth
Cowin, S. C., & Cardoso, L. (2011) · Mechanics of Materials · doi:10.1016/j.mechmat.2011.07.005 · Cited by 39
Biomechanical properties and clinical significance of cancellous bone in proximal femur: A review
Wang, H., Zhang, Y., Ren, C., Ding, K., Zhang, Q., Zhu, Y., & Chen, W. (2023) · Injury · doi:10.1016/j.injury.2023.03.010 · Cited by 43
Enns-Bray, W. S., Ariza, O., Gilchrist, S. E., Widmer, R. P., Vogt, P. J., Pálsson, H., Boyd, S. K., Guy, P., Cripton, P. A., Ferguson, S. J., et al. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.08.010 · Cited by 38
Ergun, A., Yu, X., Valdevit, A. D. C., Ritter, A., & Kalyon, D. M. (2012) · Tissue Engineering Part A · doi:10.1089/ten.tea.2011.0625 · Cited by 35
“location.(8,49) Furthermore, the compressive modulus of the bone graft substitute could be altered systematically in the axial direction (from 1.”
BackgroundAssessment of volume fraction and fabric in the distal radius using HR-pQCT
Varga, P., & Zysset, P. K. (2009) · Bone · doi:10.1016/j.bone.2009.07.001 · Cited by 40
Self-citationFabric dependence of quasi-waves in anisotropic porous media
Cardoso, L., & Cowin, S. C. (2011) · The Journal of the Acoustical Society of America · doi:10.1121/1.3557032 · Cited by 33
“The work of these authors, and Odgaard (1997, 2001), Odgaard et al. (1997), van Rietbergen et al. (1996, 1998), Matsuura et al. (2008) and others, has shown that the fabric tensor is a good measure of the structural anisotropy in cancellous bone tissue (Cowin, 1997).”
BackgroundChatterjee, S., Roy, S., Majumder, S., & Roychowdhury, A. (2020) · Journal of Biomechanical Engineering · doi:10.1115/1.4046973 · Cited by 30
Hosseini, H. S., Pahr, D. H., & Zysset, P. K. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.06.005 · Cited by 32
“…small strains, the mechanical behavior of trabecular bone is mainly governed by its tissue modulus and morphology, i.e. bone volume fraction (BV/TV) and trabecular orientation (fabric) (Matsuura et al., 2008; Goulet et al., 1994; Zysset, 2003; Rincón-Kohli and Zysset, 2009; Pahr and Zysset, 2009).”
Self-citationBiomechanics of Bone and Age-Related Fractures
Morgan, E. F., & Bouxsein, M. (2008) · Elsevier eBooks · doi:10.1016/b978-0-12-373884-4.00024-0 · Cited by 40
Ovesy, M., Aeschlimann, M., & Zysset, P. K. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2020.109844 · Cited by 35
Self-citationMetzner, F., Neupetsch, C., Fischer, J.-P., Drossel, W. G., Heyde, C.-E., & Schleifenbaum, S. (2021) · Scientific Reports · doi:10.1038/s41598-021-92685-z · Cited by 33
Bone: A Composite Natural Material
Fatima, M., Canhão, H. M., & Eurico, J. (2011) · InTech eBooks · doi:10.5772/17523 · Cited by 37
“The shape of the samples may be cubic (Diamant et al., 2007; Sun et al., 2008) or cylinder (Li & Aspden, 1997; Matsuura et al., 2008; Morgan & Keaveny, 2001).”
BackgroundMethodInfluentialMicroarchitecture and bone quality in the human calcaneus: Local variations of fabric anisotropy
Souzanchi, M. F., Palacio-Mancheno, P., Borisov, Y. A., Cardoso, L., & Cowin, S. C. (2012) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.1710 · Cited by 30
“Previous studies showed that the fabric tensor improves the prediction of the stiffness tensor.((53,66)) Whereas in the present study, all three fabric tensor components were found independent of vBMD, analysis of directional measurements of microarchitecture in the calcaneus reported inMittra and colleagues((60)) ind…”
ResultAiyangar, A. K., Vivanco, J. F., Au, A. G., Anderson, P. A., Smith, E. L., & Ploeg, H. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4027663 · Cited by 29
“In this regard, incorporating a representation of structural anisotropy, as usually derived from knowledge of the fabric tensor and attributed primarily to the trabecular structural arrangement, can substantially improve predictions of mechanical property var iations, failure [7,8] and consequently the accuracy of co…”
BackgroundMethodThe micro-structure of bone trabecular fracture: An inter-site study
Tassani, S., & Matsopoulos, G. K. (2013) · Bone · doi:10.1016/j.bone.2013.12.007 · Cited by 34
Chevalier, Y., Santos, I. I. G., Müller, P. E., & Pietschmann, M. F. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.04.003 · Cited by 23
Tassani, S., Matsopoulos, G. K., & Baruffaldi, F. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.05.019 · Cited by 23
“Numerous studies analysing the mechanical behaviour of the trabecular bone structure have been reported in the literature (Goldstein et al., 1993; Goulet et al., 1994; Ciarelli et al., 2000; Matsuura et al., 2007; Perilli et al., 2008).”
Ergun, A., Chung, R., Ward, D., Valdevit, A. D. C., Ritter, A., & Kalyon, D. M. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0484-1 · Cited by 21
Brynk, T., Hellmich, C., Fritsch, A., Zysset, P. K., & Eberhardsteiner, J. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.09.016 · Cited by 20
Self-citationBauer, J. S., Monetti, R., Krug, R., Matsuura, M., Müeller, D., Eckstein, F., Rummeny, E. J., Lochmueller, E., Raeth, C. W., & Link, T. M. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21625 · Cited by 20
“The bone marrow was removed by washing and ultrasonic cleaning (Sonorex, Bandelin Electronic, Berlin, Germany) as previously described (4).”
MethodSelf-citationLochmüller, E., Kristin, J., Matsuura, M., Kühn, V., Hudelmaier, M. I., Link, T. M., & Eckstein, F. (2008) · Calcified Tissue International · doi:10.1007/s00223-008-9172-z · Cited by 20
Self-citationExperimental validation of finite element predicted bone strain in the human metatarsal
Fung, A., Loundagin, L. L., & Edwards, W. B. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.06.010 · Cited by 26
Wood, Z., Lynn, L., Nguyen, J. T., Black, M. A., Patel, M. K., & Barak, M. M. (2019) · Bone · doi:10.1016/j.bone.2019.08.002 · Cited by 21
Bone Material Properties of Human Phalanges Using Vickers Indentation
Yin, B., Guo, J., Wang, J., Li, S., Liu, Y., & Zhang, Y. (2019) · Orthopaedic Surgery · doi:10.1111/os.12455 · Cited by 18
Cole, H., Ohba, T., Ichikawa, J., Nyman, J. S., Cates, J., Haro, H., Schwartz, H. S., & Schoenecker, J. G. (2014) · PLoS ONE · doi:10.1371/journal.pone.0097381 · Cited by 20
“Instead of using traditional test lines to determine MILs [16], the Scanco algorithm computes the distribution of MILs from surface projections [17].”
MethodA Variation of Particle Swarm Optimization for Training of Artificial Neural Networks
Zamani, M., & Sadeghi, A. (2010) · InTech eBooks · doi:10.5772/7819 · Cited by 17
Architected UHMWPE simulating trabecular bone tissue
Senatov, F. S., Niaza, K. V., Salimon, A. I., Maksimkin, A. V., & Kaloshkin, S. D. (2018) · Materials Today Communications · doi:10.1016/j.mtcomm.2018.01.001 · Cited by 17
The Mechanical Behavior of Bone
Karim, L., Hussein, A. I., Morgan, E. F., & Bouxsein, M. (2013) · Elsevier eBooks · doi:10.1016/b978-0-12-415853-5.00019-4 · Cited by 22
Smoking is a predictor of worse trabecular mechanical performance in hip fragility fracture patients
Rodrigues, A. M., Caetano‐Lopes, J., Vale, A. C., Marques‐Aleixo, I., Pena, A. S., Faustino, A., Sepriano, A. R., Pereira, J. P., Vieira‐Sousa, E., Lucas, R., et al. (2012) · Journal of Bone and Mineral Metabolism · doi:10.1007/s00774-012-0370-4 · Cited by 18
“Compressive mechanical testing represents an established method for evaluating ex vivo the mechanical competence of bone, due to its simplicity and its resemblance to natural deformation [11, 36].”
MethodRath, C. W., Baum, T. H., Monetti, R., Sidorenko, I. N., Wolf, P., Eckstein, F., Matsuura, M., Lochmüller, E., Zysset, P. K., Rummeny, E. J., et al. (2013) · Bone · doi:10.1016/j.bone.2013.09.004 · Cited by 17
Self-citationFrom Tension to Compression: Asymmetric Mechanical Behaviour of Trabecular Bone’s Organic Phase
Xie, S., Wallace, R. J., Callanan, A., & Pankaj, P. (2018) · Annals of Biomedical Engineering · doi:10.1007/s10439-018-2009-7 · Cited by 15
Chevalier, Y. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4030943 · Cited by 14
Quasi-static and ratcheting properties of trabecular bone under uniaxial and cyclic compression
Gao, L., Wei, C.-L., Zhang, C., Gao, H. X., Yang, N., & Dong, L. (2017) · Materials Science and Engineering C · doi:10.1016/j.msec.2017.03.214 · Cited by 14
Dark-field X-ray imaging for the assessment of osteoporosis in human lumbar spine specimens
Gassert, F. T., Urban, T., Kufner, A., Frank, M., Feuerriegel, G. C., Baum, T. H., Makowski, M. R., Braun, C., Pfeiffer, D., Schwaiger, B. J., et al. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1217007 · Cited by 18
“The results demonstrated that the dark-field signal was higher in the horizontal position compared to the vertical position, suggesting a higher number of trabeculae in vertical orientation compared to horizontal orientation, which is in line with previous findings (Amling et al., 1996; Homminga et al., 2004; Matsuura…”
ResultHe, L., Zhao, M., Cheung, J. P. Y., Zhang, T. G., & Ren, X. (2024) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2024.106443 · Cited by 16
Strain rate dependency of bovine trabecular bone under impact loading at sideways fall velocity
Enns-Bray, W. S., Ferguson, S. J., & Helgason, B. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.04.042 · Cited by 15
Tortuosity and the Averaging of Microvelocity Fields in Poroelasticity
Souzanchi, M. F., Cardoso, L., & Cowin, S. C. (2012) · Journal of Applied Mechanics · doi:10.1115/1.4007923 · Cited by 13
Schwiedrzik, J. J., Kh, K., Burner, U., & Zysset, P. K. (2011) · Bone · doi:10.1016/j.bone.2011.03.768 · Cited by 14
Self-citationThe effect of cement augmentation on pedicle screw fixation under various load cases
Chevalier, Y., Matsuura, M., Krüger, S., Traxler, H., Fleege, C., Rauschmann, M., & Schilling, C. (2021) · Bone and Joint Research · doi:10.1302/2046-3758.1012.bjr-2020-0533.r1 · Cited by 11
Self-citationPrediction of Vertebral Failure Load by Using X-Ray Vector Radiographic Imaging
Eggl, E., Malecki, A., Schaff, F., Potdevin, G., Noël, P. B., Bauer, J. S., Gordijenko, O., García, E. G., Burgkart, R., Rummeny, E. J., et al. (2014) · Radiology · doi:10.1148/radiol.14141317 · Cited by 12
A Method for the Evaluation of Femoral Head Trabecular Bone Compressive Properties
Aleixo, I., Vale, A. C., Lúcio, M., Amaral, P. M., Rosa, L. G., Caetano‐Lopes, J., Rodrigues, A. M., Canhão, H. M., Fonseca, J. E., & Vaz, M. F. (2012) · Materials science forum · doi:10.4028/www.scientific.net/msf.730-732.3 · Cited by 11
Sidorenko, I. N., Monetti, R., Bauer, J. S., Müeller, D., Rummeny, E. J., Eckstein, F., Matsuura, M., Lochmueller, E., Zysset, P. K., & Raeth, C. W. (2011) · Current Medicinal Chemistry · doi:10.2174/092986711796504754 · Cited by 10
Self-citationTassani, S., Particelli, F., Perilli, E., Traina, F., Baruffaldi, F., & Viceconti, M. (2011) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2011.01.010 · Cited by 17
Alexander, S. L., Gunnarsson, C. A., & Weerasooriya, T. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.04.010 · Cited by 8
Limit analysis of human proximal femur
Pisano, A. A., & Fuschi, P. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104844 · Cited by 8
Chevalier, Y., & Zysset, P. K. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4006688 · Cited by 7
“A first study of a combined axial compression and anterior bending loading case showed good correlations between axial stiffness and the coupling rigidities [3].”
BackgroundMethodResultInfluentialSelf-citationKim, W., Oravec, D. J., Divine, G., Flynn, M. J., & Yeni, Y. N. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1792-x · Cited by 8
Estimating tissue-level properties of porcine talar subchondral bone
Koria, L., Mengoni, M., & Brockett, C. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103931 · Cited by 7
The Hydration State of Bone Tissue Affects Contrast in Neutron Tomographic Images
Törnquist, E., Cann, S. L., Tengattini, A., Helfen, L., Kok, J., Hall, S. A., & Isaksson, H. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.911866 · Cited by 6
“, anisotropy and trabecular thickness, also influence the mechanical behavior of these types of specimens (Matsuura et al., 2008; Maquer et al., 2015).”
BackgroundShore, S. W., Unnikrishnan, G. U., Hussein, A. I., & Morgan, E. F. (2012) · CRC Press eBooks · doi:10.1201/b13733-3 · Cited by 8
Emerging Research on Bone Health Using High-Resolution CT and MRI
Liebl, H., Baum, T. H., Karampinos, D. C., Patsch, J., Malecki, A., Schaff, F., Eggl, E., Rummeny, E. J., Pfeiffer, F., & Bauer, J. S. (2013) · Current Radiology Reports · doi:10.1007/s40134-013-0031-y · Cited by 6
“Aside from the aforementioned morphometric parameters, additional parameters such as fabric [61], a trabecular anisotropy measurement, texture parameters derived from binarized images [62] and Minkowski functionals [63] as non-linear topological parameters evaluating volume, surface area, mean integral curvature and E…”
MethodRischewski, J., Gassert, F. T., Urban, T., Hammel, J., Kufner, A., Braun, C., Lochschmidt, M. E., Makowski, M. R., Pfeiffer, D., Gersing, A. S., et al. (2024) · European Radiology Experimental · doi:10.1186/s41747-024-00524-3 · Cited by 9
In-Silico Models of Trabecular Bone: A Sensitivity Analysis Perspective
Mengoni, M., Sikora, S. N. F., D'Otreppe, V., Wilcox, R. K., & Jones, A. C. (2015) · Studies in mechanobiology, tissue engineering and biomaterials · doi:10.1007/978-3-319-21296-8_15 · Cited by 5
The effects of force application on the compressive properties of femoral spongious bone
Metzner, F., Fischer, B., Heyde, C.-E., & Schleifenbaum, S. (2022) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2022.105866 · Cited by 5
Hesse, N., Strack, D., Rischewski, J., Gassert, F., Kufner, A., Urban, T., Lochschmidt, M., Schwaiger, B., Braun, C., Mueller, D., et al. (2025) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-025-08709-6 · Cited by 3
“In previous studies, a higher dark-field signal in horizontal position compared to the signal in vertical position suggested a higher number of trabeculae in vertical orientation [18, 20, 41–43].”
Vertebral Trabecular Bone Mechanical Properties Vary Among Functional Groups of Cetaceans
Ingle, D. N., & Porter, M. E. (2022) · Integrative Organismal Biology · doi:10.1093/iob/obab036 · Cited by 3
“6 ; Yeni and Fyhrie 2001 ; Banse et al. 2002 ; Pilcher 2004 ; Matsuura et al. 2008 ; Follet et al. 2011 ; Slyfield et al. 2012 ; Aiyanger et al. 2014 ; Ingle and Porter 2020 ).”
Integrated analysis of clinical indicators and mechanical properties in cancellous bone
He, J., Pan, Z., Zhou, G., Yu, J., & Li, D. (2024) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2024.104245 · Cited by 4
He, J., Zhou, G., Xie, Y., Cao, Z., Li, Z., Kruzic, J. J., Li, X., Li, D., & Yu, J. (2025) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2025.107211 · Cited by 4
Sidorenko, I. N., Bauer, J. S., Monetti, R., Müller, D., Rummeny, E. J., Eckstein, F., Matsuura, M., Lochmüller, E., Zysset, P. K., & Rath, C. W. (2009) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.811091 · Cited by 3
“The cylindrical specimens with a diameter of 8 mm were harvested from 73 thoracic and 78 lumbar human vertebral in vitro [6] .”
MethodSelf-citationDall’Ara, E., & Cheong, V. S. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-824481-4.00007-x · Cited by 5
Changes in subchondral bone morphology with osteoarthritis in the ankle
Koria, L., Farndon, M. A., Jones, E., Mengoni, M., & Brockett, C. (2024) · PLoS ONE · doi:10.1371/journal.pone.0290914 · Cited by 4
The mechanical behavior of bone
Karim, L., Hussein, A. I., Vaidya, R., Morgan, E. F., & Bouxsein, M. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-813073-5.00013-7 · Cited by 4
Evaluation of Human Bones Load Bearing Capacity with the Limit Analysis Theory
Pisano, A. A., & Fuschi, P. (2020) · Lecture notes in applied and computational mechanics · doi:10.1007/978-3-030-48834-5_1 · Cited by 2
Monetti, R., Bauer, J. S., Müeller, D., Rummeny, E. J., Link, T. M., Majumdar, S., Matsuura, M., Eckstein, F., Sidorenko, I. N., & Raeth, C. W. (2008) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.769161 · Cited by 2
“The importance of assessing trabecular bone architecture in conjunction with BMD has been established in several studies [1-5].”
BackgroundSelf-citationThe Role of Microarchitecture on Absorption and Scattering of Ultrasound Waves in Trabecular Bone
Cardoso, L., & Cowin, S. C. (2013) · Fifth Biot Conference on Poromechanics · doi:10.1061/9780784412992.143 · Cited by 1
Kaulinio audinio patologijos poveikio žmogaus stuburo stabilumui skaitinis tyrimas
Chabarova, O. (2020) · doi:10.20334/2020-015-m · Cited by 1
Metadata
- Authors
- Matsuura, M., Eckstein, F., Lochmüller, E.-M., & Zysset, P. K.
- Affiliations
- Anatomische Anstalt (DE)
- Paracelsus Medical University (AT)
- Ludwig-Maximilians-Universität München (DE)
- TU Wien (AT)
- Corresponding author
- Zysset, Philippe K.
- Venue
- Biomechanics and Modeling in Mechanobiology
- Published
- 2007-01-19
- Volume
- 7
- Issue
- 1
- Pages
- 27-42
- ISSN
- 1617-7940 (ISSN-L)
- 1617-7959
- OpenAlex
- W2037829287
- Cited by
- 117
- References
- 39
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 4 · 2023: 5 · 2022: 4 · 2021: 8 · 2020: 7 · 2019: 3 · 2018: 5 · 2017: 3 · 2016: 4 · 2015: 6 · 2014: 6 · 2013: 11 · 2012: 18
- FWCI
- 6.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Biomechanics and Modeling in Mechanobiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- trabecular bone, textiles, microstructural anisotropy, bone volume fraction, elastic modulus, yield stress, ultimate stress, osteoporosis, bone fracture risk, human bone
- MeSH terms
- Bone and Bones, Humans, Materials Testing, Tomography, X-Ray Computed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.