Cited by 153Cardiovascular Syncope and Autonomic DisordersHeart Rate Variability and Autonomic ControlBlood Pressure and Hypertension Studies

Use of lower abdominal compression to combat orthostatic hypotension in patients with autonomic dysfunction

Smit, AdrianusA.J., Wieling, Wouter, Fujimura, Jiro, Denq, JongC., Opfer-Gehrking, TonetteL., Akarriou, Mohammed, Karemaker, JohnM., Low, PhillipA.·2004·Clinical Autonomic Research

Abstract

The aim of this study was to investigate in patients with neurogenic orthostatic hypotension the mechanism and usefulness of abdominal compression to increase standing blood pressure. In three protocols, 23 patients underwent abdominal compression. Protocol 1 evaluated in a 40-60 degrees head-up-tilt position, the effect of abdominal compression on caval vein and femoral diameter, arterial blood pressure and hemodynamics. Protocol 2 documented the relationship between the level of compression and the arterial pressure response. Protocol 3 investigated the ability to maintain standing blood pressure by an elastic binder. During head-up-tilt, compression (40 mm Hg) resulted in a reduction in diameter of the caval vein (mean -2.6mm, range -1.4 to 0.6), without a change in femoral vein diameter. Stroke volume increased by 14 % (range -1 to 23) and blood pressure (systolic/diastolic) by 30/14 mmHg (range 7/2 to 69/36), both p < 0.05; 40 mmHg compression was associated with a higher pressure response than 20 mmHg (mean 18/8 mmHg, range 6/2 to 43/20 vs. mean 9/4 mmHg, range -1/0 to 18/8, p < 0.05). Elastic abdominal binding increased standing blood pressure with 15/6 mmHg (range -3/3 to 36/14, p < 0.05). We conclude that in patients with neurogenic orthostatic hypotension, abdominal compression increases standing blood pressure to a varying degree by increasing stroke volume.

Integrity signals

Registry

Crossref · 10.1007/s10286-004-0187-x

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • These measures increase venous return and lessen orthostatic tachycardia.

    “These measures increase venous return and lessen orthostatic tachycardia (105).”

    From Postural Orthostatic Tachycardia Syndrome (2019) · cites this paper as [105]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Smit, A. J., Wieling, W., Fujimura, J., Denq, J., Opfer-Gehrking, T., Akarriou, M., Karemaker, J., & Low, P.
Affiliations
  • Amsterdam UMC Location University of Amsterdam (NL)
  • Mayo Clinic (US)
Venue
Clinical Autonomic Research
Published
2004-06
Volume
14
Issue
3
Pages
167-75
ISSN
  • 0959-9851 (ISSN-L)
  • 1619-1560
OpenAlex
W2084471340
Cited by
153
References
43
Citations by year
2026: 5 · 2025: 9 · 2024: 11 · 2023: 3 · 2022: 3 · 2021: 6 · 2020: 7 · 2019: 8 · 2018: 11 · 2017: 12 · 2016: 6 · 2015: 7 · 2014: 13 · 2013: 9 · 2012: 6
FWCI
2.85
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Autonomic Research (publishedVersion)
  • PubMed (publishedVersion)
  • Pure Amsterdam UMC (publishedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
Funders
  • National Aeronautics and Space Administration
  • Nederlandse Organisatie voor Wetenschappelijk Onderzoek
  • National Institute of Neurological Disorders and Stroke (P01 NS 32352)
Topics
  • Health Sciences › Medicine › Surgery › Cardiovascular Syncope and Autonomic Disorders
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
Keywords
orthostatic hypotension, neurogenic orthostatic hypotension, autonomic dysfunction, abdominal compression, head-up tilt, standing blood pressure, stroke volume, vein diameter, hemodynamics
MeSH terms
Abdomen, Adult, Aged, Autonomic Nervous System Diseases, Blood Pressure, Diabetic Neuropathies, Female, Gravity Suits, Heart Rate, Hemodynamics, Humans, Hypotension, Orthostatic, Male, Middle Aged, Rest, Veins, Supine Position, Blood Pressure Monitoring, Ambulatory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review