MRI for attenuation correction in PET: methods and challenges
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
In current combined PET/MR systems, PET attenuation correction is based on MRI, since the small bore inside MRI systems and the strong magnetic field do not permit a rotating PET transmission source or a CT device to be integrated. Unlike CT measurements in PET/CT scanners, the MR signal is not directly correlated to tissue density and thus cannot be converted by a simple transformation of intensity values. Various approaches have been developed based on templates, atlas information, direct segmentation of T1-weighted MR images, or segmentation of images from special MR sequences. The advantages and disadvantages of these approaches as well as additional challenges will be discussed in this review.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265 · cited 1×
“For nonlinear registration, SPM2 or a B-spline free-form deformation algorithm [17] was used.”
MethodNonlinear spatial normalization using basis functions
Ashburner, J., & Friston, K. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)7:4<254::aid-hbm4>3.0.co;2-g · Cited by 1,884 · cited 6×
“(HR?-PET) of 10 healthy subjects (females and males) via spatial normalisation to the standard brain of SPM2 [15].”
BackgroundMethodInfluentialDesign and construction of a realistic digital brain phantom
Collins, D. L., Zijdenbos, A. P., Kollokian, V., Sled, J. G., Kabani, N. J., Holmes, C. J., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712135 · Cited by 1,822 · cited 1×
“[16] composed of the BrainWeb and Zubal digital phantoms [22, 23] and man-”
Computerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
Tissue Substitutes in Radiation Dosimetry and Measurement
Cloutier, R. J. (1989) · Radiation Research · doi:10.2307/3577533 · Cited by 1,076
Martinez-Möller, A., Souvatzoglou, M., Delso, G., Bundschuh, R. A., Chefd'hotel, C., Ziegler, S. I., Navab, N., Schwaiger, M., & Nekolla, S. G. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.054726 · Cited by 712 · cited 9×
“0 [21, 36, 44, 45, 49]”
BackgroundMethodInfluentialThree‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction
Glover, G. H., & Schneider, E. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180211 · Cited by 687 · cited 1×
“[40] proposed a new UTE triple-echo (UTILE) MR sequence combining UTE for bone detection with Dixon water-fat separation [41] to distinguish four tissue classes (bone, air, soft, and adipose tissue) by postprocessing procedures.”
BackgroundHofmann, M., Steinke, F., Scheel, V., Charpiat, G., Farquhar, J., Aschoff, P., Brady, M., Schölkopf, B., & Pichler, B. J. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.049353 · Cited by 495 · cited 2×
“Small sample sizes can lead to problems in the significance of statistical results [19].”
BackgroundMethodMRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time Sequences
Keereman, V., Fierens, Y., Broux, T., De Deene, Y., Lonneux, M., & Vandenberghe, S. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.065425 · Cited by 442 · cited 6×
“70–150 ls [38]) measuring the sampled fast induction decay (FID) signal and visualises bone tissue.”
BackgroundInfluentialBurger, C., Goerres, G., Schoenes, S., Buck, A., Lonn, A., & von Schulthess, G. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-0796-3 · Cited by 428 · cited 5×
“General Electric (GE) provides a tri-modality system with a transferable patient table which can be docked onto the PET/CT and MR system installed in two different examination rooms.”
MethodInfluentialPET/MRI: Paving the Way for the Next Generation of Clinical Multimodality Imaging Applications
Pichler, B. J., Kolb, A., Nägele, T., & Schlemmer, H.-P. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.061853 · Cited by 418 · cited 1×
“More information about the technical details and challenges of hybrid systems can be found in [2, 3].”
BackgroundDesign and performance evaluation of a whole-body Ingenuity TF PET–MRI system
Zaidi, H., Ojha, N., Morich, M., Griesmer, J., Hu, Z., Maniawski, P., Ratib, O., Izquierdo-Garcia, D., Fayad, Z. A., & Shao, L. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/10/013 · Cited by 402 · cited 1×
“1 Hybrid PET/MR scanners: Philips Gemini TF PET/MR system where the PET and the MR system share a common patient table [1] (courtesy of H.”
MethodCatana, C., van der Kouwe, A., Benner, T., Michel, C. J., Hamm, M., Fenchel, M., Fischl, B., Rosen, B., Schmand, M., & Sorensen, A. G. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.069112 · Cited by 359 · cited 2×
“[24], soft tissue is masked with a morphologic closing and opening filter applied to the second echo data to segment the head and exclude voxels outside the head.”
BackgroundMethodBerker, Y., Franke, J., Salomon, A., Palmowski, M., Donker, H. C. W., Temur, Y., Mottaghy, F. M., Kuhl, C., Izquierdo-Garcia, D., Fayad, Z. A., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092577 · Cited by 344 · cited 1×
“[40] proposed a new UTE triple-echo (UTILE) MR sequence combining UTE for bone detection with Dixon water-fat separation [41] to distinguish four tissue classes (bone, air, soft, and adipose tissue) by postprocessing procedures.”
BackgroundSelf-citationTowards quantitative PET/MRI: a review of MR-based attenuation correction techniques
Hofmann, M., Pichler, B., Schölkopf, B., & Beyer, T. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-1007-7 · Cited by 343 · cited 4×
“[20] regarded 4D MR-based attenuation correction as a great advantage over CT-based attenuation correction.”
BackgroundMethodInfluentialJohansson, A., Karlsson, M., & Nyholm, T. (2011) · Medical Physics · doi:10.1118/1.3578928 · Cited by 324 · cited 2×
“[42] developed a purely”
Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data
Schulz, V., Torres-Espallardo, I., Renisch, S., Hu, Z., Ojha, N., Börnert, P., Perkuhn, M., Niendorf, T., Schäfer, W. M., Brockmann, H., et al. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1603-1 · Cited by 292 · cited 2×
“[36] presented an approach based on Laplace-weighted histograms to threshold the outer body contour and to segment the lung by restricted region growing, making use of additional size criteria to identify the correct clusters.”
BackgroundMethodSelf-citationHofmann, M., Bezrukov, I., Mantlik, F., Aschoff, P., Steinke, F., Beyer, T., Pichler, B. J., & Schölkopf, B. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.078949 · Cited by 288 · cited 4×
“[21] predicted that the limit is an error of 10 %, and smaller errors do not influence diagnosis, particularly in oncology.”
BackgroundMethodInfluentialMethod for transforming CT images for attenuation correction in PET/CT imaging
Carney, J. P. J., Townsend, D. W., Rappoport, V., & Bendriem, B. (2006) · Medical Physics · doi:10.1118/1.2174132 · Cited by 271 · cited 5×
“General Electric (GE) provides a tri-modality system with a transferable patient table which can be docked onto the PET/CT and MR system installed in two different examination rooms.”
MethodInfluentialSamarin, A., Burger, C., Wollenweber, S. D., Crook, D. W., Burger, I. A., Schmid, D. T., von Schulthess, G. K., & Kuhn, F. P. (2012) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-012-2113-0 · Cited by 251 · cited 1×
“In accordance with the results reported by Samarin for bone lesions [48], quantitative PET results obtained by Keereman et al.”
ResultTime-of-flight PET data determine the attenuation sinogram up to a constant
Defrise, M., Rezaei, A., & Nuyts, J. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/4/885 · Cited by 234 · cited 1×
“[60] suggested a new method which aims to reconstruct both attenuation and activity images from PET”
MethodZaidi, H., Montandon, M.-L., & Slosman, D. O. (2003) · Medical Physics · doi:10.1118/1.1569270 · Cited by 233 · cited 1×
“[25] developed a segmentation approach based on fuzzy clustering to segment T1-weighted MR images into air, skull, brain tissue, and nasal sinuses further refined with morphological operations.”
MethodAn outlook on future design of hybrid PET/MRI systems: Design of hybrid PET/MRI scanners
Zaidi, H., & Del Guerra, A. (2011) · Medical Physics · doi:10.1118/1.3633909 · Cited by 193 · cited 3×
“6)) are not visible in MR images but contribute considerably to the attenuation map [46].”
BackgroundEiber, M., Martinez-Möller, A., Souvatzoglou, M., Holzapfel, K., Pickhard, A., Löffelbein, D., Santi, I., Rummeny, E. J., Ziegler, S., Schwaiger, M., et al. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1842-9 · Cited by 173
Two‐point Dixon technique for water‐fat signal decomposition with B0 inhomogeneity correction
Coombs, B. D., Szumowski, J., & Coshow, W. R. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380606 · Cited by 141 · cited 1×
“Two-point Dixon sequences [43], which need only a few”
BackgroundSchreibmann, E., Nye, J. A., Schuster, D. M., Martín, D. R., Votaw, J. R., & Fox, T. H. (2010) · Medical Physics · doi:10.1118/1.3377774 · Cited by 124
A look ahead: PET/MR versus PET/CT
von Schulthess, G. K., & Schlemmer, H.-P. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0940-9 · Cited by 120
Evaluation of the attenuation properties of MR equipment for its use in a whole-body PET/MR scanner
Delso, G., Martínez-Möller, A., Bundschuh, R. A., Ladebeck, R., Candidus, Y., Faul, D. D., & Ziegler, S. I. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/15/011 · Cited by 118 · cited 1×
“[52] found that head and neck coils induce 17 % count loss in PET transmission scans and that the misregistration of coil”
BackgroundThe effect of errors in segmented attenuation maps on PET quantification
Keereman, V., Holen, R. V., Mollet, P., & Vandenberghe, S. (2011) · Medical Physics · doi:10.1118/1.3651640 · Cited by 108 · cited 5×
“Errors in the reconstructed PET images grew from less than 5 to 17 % when bone tissue was ignored in the attenuation map and up to 45 % when lung tissue was ignored [6].”
BackgroundMethodInfluentialThe effect of limited MR field of view in MR/PET attenuation correction
Delso, G., Martínez-Möller, A., Bundschuh, R. A., Nekolla, S. G., & Ziegler, S. I. (2010) · Medical Physics · doi:10.1118/1.3431576 · Cited by 102
The current state, challenges and perspectives of MR-PET
Herzog, H. R., Pietrzyk, U., Shah, N. J., & Ziemons, K. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.036 · Cited by 92 · cited 1×
“Thus, specially designed RF coils with lower attenuation and positioning strategies based on coil landmarks must be developed to reduce these problems [20, 50].”
BackgroundSelf-citationMalone, I. B., Ansorge, R. E., Williams, G. B., Nestor, P. J., Carpenter, T. A., & Fryer, T. D. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.085076 · Cited by 85 · cited 7×
“[16] found the highest variability in parts of the frontal cortex near the sinus regions, which may reduce the detection of significant changes between groups or subjects, for example, in frontotemporal dementia.”
BackgroundMethodResultInfluentialAtlas-guided non-uniform attenuation correction in cerebral 3D PET imaging
Montandon, M., & Zaidi, H. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.11.021 · Cited by 83 · cited 1×
“Template-based methods were initially suggested for situations where a transmission scan of the subject investigated is not available in PET [12].”
MethodTellmann, L., Quick, H. H., Bockisch, A., Herzog, H., & Beyer, T. (2011) · Medical Physics · doi:10.1118/1.3582699 · Cited by 82
Self-citationAlternative methods for attenuation correction for PET images in MR-PET scanners
Kops, E. R., & Herzog, H. (2007) · 2006 IEEE Nuclear Science Symposium Conference Record · doi:10.1109/nssmic.2007.4437073 · Cited by 80 · cited 3×
“[13] used BrainSuite2 [27] and the MPITool (Advanced Tomo Vision GmbH, Kerpen, Germany) to distinguish bone, cavities, brain, and soft tissue to which the corresponding attenuation coefficients were assigned”
BackgroundMethodSelf-citationPET-MRI Fusion in Head-and-Neck Oncology: Current Status and Implications for Hybrid PET/MRI
Loeffelbein, D. J., Souvatzoglou, M., Wankerl, V., Martínez-Möller, A., Dinges, J., Schwaiger, M., & Beer, A. J. (2011) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2011.02.120 · Cited by 80 · cited 1×
“fast examination protocols will be provided [4–6].”
BrainSuite: An Automated Cortical Surface Identification Tool
Shattuck, D. W., & Leahy, R. M. (2000) · Lecture notes in computer science · doi:10.1007/978-3-540-40899-4_6 · Cited by 75
Effects of MR surface coils on PET quantification
MacDonald, L. R., Kohlmyer, S. G., Liu, C., Lewellen, T. K., & Kinahan, P. E. (2011) · Medical Physics · doi:10.1118/1.3583697 · Cited by 71 · cited 1×
“[55] measured an underestimation of 19 % when the head coil is not included in the attenuation map, but a 28 % overestimation due to the overestimated high-density components within the coil in the CT.”
BackgroundMR-based attenuation correction for a whole-body sequential PET/MR system
Hu, Z., Ojha, N., Renisch, S., Schulz, V., Torres, I., Buhl, A., Pal, D., Muswick, G. J., Penatzer, J., Guo, T., et al. (2009) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2009.5401802 · Cited by 69 · cited 2×
“Postprocessing with region growing including a distance constraint and additional morphological opening was added to further improve the lung segmentation [34, 35].”
BackgroundTemplate based attenuation correction for PET in MR-PET scanners
Kops, E. R., & Herzog, H. R. (2008) · 2006 IEEE Nuclear Science Symposium Conference Record · doi:10.1109/nssmic.2008.4774281 · Cited by 65 · cited 2×
“In [14], separate female and male templates averaged over four volunteers each are generated.”
BackgroundMethodSelf-citationWhole-body hybrid PET/MRI: ready for clinical use?
Ratib, O. M., & Beyer, T. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1790-4 · Cited by 56 · cited 1×
“Further problems with accurate attenuation correction remain to be solved [5] to avoid errors in the MR-derived”
BackgroundAdvances in Attenuation Correction Techniques in PET
Zaidi, H., Montandon, M., & Alavi, A. A. (2007) · PET Clinics · doi:10.1016/j.cpet.2007.12.002 · Cited by 55 · cited 4×
“Thus, only 22 and 5.5 %, respectively, of the radiation emitted by the radiolabelled tracer in the direction of an LOR is recorded by the PET detector.”
BackgroundInfluentialCombined PET/MR systems: an overview and comparison of currently available options.
Herzog, H. R., & van den Hoff, J. (2012) · PubMed · Cited by 48
Self-citationThe effect of patient positioning aids on PET quantification in PET/MR imaging
Mantlik, F., Hofmann, M., Werner, M. K., Sauter, A. W., Kupferschläger, J., Schölkopf, B., Pichler, B. J., & Beyer, T. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1721-9 · Cited by 39 · cited 1×
“[51] analysed the deviation of PET activity values when positioning devices were disregarded for attenuation correction.”
Attenuation correction for MR table and coils for a sequential PET/MR system
Zhang, B., Pal, D., Hu, Z., Ojha, N., Guo, T., Muswick, G. J., Tung, C., & Kaste, J. (2009) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2009.5401737 · Cited by 29 · cited 2×
“Examples of a spine and a head coil (a) and a patient table (b) as well as one transaxial slice of the corresponding templates generated from PET transmission scans are shown [54] (courtesy of B.”
BackgroundMethodThe effect of inaccurate bone attenuation coefficient and segmentation on reconstructed PET images
Schleyer, P. J., Schaeffter, T., & Marsden, P. K. (2010) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e32833b0573 · Cited by 28 · cited 1×
“[47] investigated different constant patient-specific and generic attenuation coefficients for bone in whole-body imaging.”
BackgroundWagenknecht, G., Kops, E. R., Tellmann, L., & Herzog, H. R. (2009) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2009.5401751 · Cited by 28 · cited 1×
“The mastoid process consists of lamellar bone and air-filled entities and thus is segmented as a separate region to enable the assignment of a special attenuation coefficient [30].”
BackgroundSelf-citationAttenuation correction in MR-PET scanners with segmented T1-weighted MR images
Kops, E. R., Wagenknecht, G., Scheins, J. J., Tellmann, L., & Herzog, H. R. (2009) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2009.5402034 · Cited by 21 · cited 5×
“146 [13, 30–33]”
MethodSelf-citationMR-based attenuation correction for whole-body PET/MR system
Hu, Z., Renisch, S., Schweizer, B., Blaffert, T., Ojha, N., Guo, T., Tang, J., Tung, C., Kaste, J., Schulz, V., et al. (2010) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2010.5874153 · Cited by 20 · cited 2×
“Postprocessing with region growing including a distance constraint and additional morphological opening was added to further improve the lung segmentation [34, 35].”
BackgroundCompletion of a truncated attenuation image from the attenuated PET emission data
Nuyts, J. L., Michel, C. J., Fenchel, M., Bal, G., & Watson, C. (2010) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2010.5874154 · Cited by 18
CT-based evaluation of segmented head regions for attenuation correction in MR-PET systems
Wagenknecht, G., Kops, E. R., Kaffanke, J. B., Tellmann, L., Mottaghy, F. M., Piroth, M. D., & Herzog, H. (2010) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2010.5874301 · Cited by 16 · cited 2×
“4 Principles of the direct knowledge-based segmentation approach for attenuation correction in brain studies presented in [31]: The input image (top left) is classified (top middle) and postprocessed to separate the extracerebral region (top right).”
BackgroundMethodSelf-citationWagenknecht, G., Kops, E. R., Mantlik, F., Fried, E., Pilz, T., Hautzel, H., Tellmann, L., Pichler, B. J., & Herzog, H. R. (2011) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2011.6153858 · Cited by 16 · cited 1×
“attenuation correction approaches using predefined attenuation coefficients [32].”
MethodSelf-citationDesign of a realistic PET-CT-MRI phantom
Keereman, V., Mollet, P., Fierens, Y., España, S., & Vandenberghe, S. (2011) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2011.6153651 · Cited by 11 · cited 2×
“New phantoms simulating the attenuation properties of the most important tissues may help in doing so [45].”
BackgroundAkbarzadeh, A., Ay, M. R., Ahmadian, A., Alam, N. R., & Zaidi, H. (2011) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2011.6152682 · Cited by 10 · cited 1×
“[37] segmented up to four classes—soft tissue, lung, spongious, and cortical bone—using the ITK library.”
MethodInvestigation of 4D PET attenuation correction using Ultra-short Echo Time MR
Buerger, C., Aitken, A. P., Tsoumpas, C., King, A. P., Schulz, V., Marsden, P. K., & Schaeffter, T. (2011) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2011.6153668 · Cited by 8 · cited 1×
“[49] presented a 4D approach, combining a respiratory-gated UTE sequence and a short dynamic MR sequence.”
MethodRadiofrequency coil design for simultaneous PET/MR systems
Herrick, P. D. E., Ansorge, R. E., Hawkes, R. C., Sawiak, S. J., Stevick, J. W., & Carpenter, T. A. (2010) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2010.5874250 · Cited by 6 · cited 1×
“[56] mentioned that due to the increasing relative size of MR hardware compared to the size of the animal measured in preclinical applications, and the resultant attenuation effects may exceed that of soft tissue or bone.”
Background
Cited by
A review of substitute CT generation for MRI-only radiation therapy
Edmund, J. M., & Nyholm, T. (2017) · Radiation Oncology · doi:10.1186/s13014-016-0747-y · Cited by 378
Mehranian, A., Arabi, H., & Zaidi, H. (2016) · Medical Physics · doi:10.1118/1.4941014 · Cited by 152
Qualitative and Quantitative Comparison of PET/CT and PET/MR Imaging in Clinical Practice
Al-Nabhani, K. Z., Syed, R., Michopoulou, S., Alkalbani, J., Afaq, A., Panagiotidis, E., O’Meara, C., Groves, A., Ell, P., & Bomanji, J. (2014) · Journal of Nuclear Medicine · doi:10.2967/jnumed.113.123547 · Cited by 101
Rausch, I., Valladares, A., Sundar, L. K. S., Beyer, T., Hacker, M., Meyerspeer, M., & Unger, E. (2021) · EJNMMI Physics · doi:10.1186/s40658-021-00364-9 · Cited by 11
Metadata
- Authors
- Wagenknecht, G., Kaiser, H.-J., Mottaghy, F. M., & Herzog, H.
- Venue
- Magnetic Resonance Materials in Physics, Biology and Medicine
- Published
- 2012-11-21
- Volume
- 26
- Issue
- 1
- Pages
- 99-113
- ISSN
- 0968-5243 (ISSN-L)
- 1352-8661
- OpenAlex
- W1991035308
- Cited by
- 232
- References
- 56
- FWCI
- 12.46
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.