Seprafilm® adhesion barrier: (2) a review of the clinical literature on intraabdominal use
Open accessThe DOI matches its Crossref record.
Abstract
This study seeks to provide a review of the clinical data published as of July 2011 concerning the postsurgical adhesion barrier, Seprafilm (chemically modified hyaluronic acid and carboxymethylcelulose; Genzyme Corporation, Cambridge, MA). Included articles detail the application of Seprafilm for intraabdominal uses that have been approved (on-label) and those considered investigational (off-label) by the FDA. Medline and EMBASE Drugs and Pharmaceuticals databases were searched for all original clinical Seprafilm research published as of July 2011. All human Seprafilm intraabdominal clinical reports and studies, excluding those related to prosthetic mesh were included. Data extraction involved the systematic review of each article. The data synthesis is the summary of Seprafilm human intraabdominal clinical reports and studies describing safety and/or efficacy. The safety and efficacy of Seprafilm in reducing postoperative adhesions has been clearly demonstrated in abdominal and pelvic laparotomy. While reports have described the safe and successful use of Seprafilm following laparoscopy, pediatric laparotomy, and in patients with malignancy and/or infection, the safety and efficacy of Seprafilm use in these procedures has not been definitively established in randomized controlled trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nam, S., & Mooney, D. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00798 · Cited by 764
Peritoneal adhesions: Occurrence, prevention and experimental models
Tang, J., Xiang, Z., Bernards, M. T., & Chen, S. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.08.036 · Cited by 211
Advancement of Biomaterial-Based Postoperative Adhesion Barriers
Chandel, A. K. S., Shimizu, A., Hasegawa, K., & Ito, T. (2021) · Macromolecular Bioscience · doi:10.1002/mabi.202000395 · Cited by 138
Erdi, M., Rozyyev, S., Balabhadrapatruni, M., Saruwatari, M. S., Daristotle, J. L., Ayyub, O. B., Sandler, A. D., & Kofinas, P. (2023) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10335 · Cited by 25
“However, these cellulose-derived dressings are inherently brittle prior to swelling due to their crystallinity, and lose significant adhesive and cohesive strength after swelling.(19,20) In addition, Seprafilm and other synthetic hydrogel-based materials may impede wound healing and are especially difficult to use in…”
BackgroundEvaluation of the effectiveness of alginate-based hydrogels in preventing peritoneal adhesions
Meng, Z., Wang, H., Liu, Y., Yang, M., Zeng, H., & Han, Q. (2023) · Regenerative Biomaterials · doi:10.1093/rb/rbad017 · Cited by 15
Erdi, M., Saruwatari, M. S., Rozyyev, S., Acha, C., Ayyub, O. B., Sandler, A. D., & Kofinas, P. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c00283 · Cited by 15
Physical and biological properties of a novel anti-adhesive punctate uneven gelatin film
Ozamoto, Y., Horii, T., Morita, S., Tsujimoto, H., Oe, Y., Minato, H., Ueda, J., Ichikawa, H., Kawauchi, A., Hagiwara, A., et al. (2025) · PLOS ONE · doi:10.1371/journal.pone.0314159 · Cited by 2
Metadata
- Authors
- Diamond, M. P., Burns, E. L., Accomando, B., Mian, S., & Holmdahl, L.
- Venue
- Gynecological Surgery
- Published
- 2012-04-15
- Volume
- 9
- Issue
- 3
- Pages
- 247-257
- ISSN
- 1613-2076 (ISSN-L)
- 1613-2084
- OpenAlex
- W1972390139
- Cited by
- 85
- References
- 0
- Type
- book review
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.