Vascular Dynamics of a Shape Memory Polymer Foam Aneurysm Treatment Technique
The DOI matches its Crossref record; 82 of the 84 references it cites were found in a registry or an index.
Abstract
The vascular dynamics of a shape memory polymer foam aneurysm treatment technique are assessed through the simulated treatment of a generic basilar aneurysm using coupled fluid dynamics and heat transfer calculations. The shape memory polymer foam, which expands to fill the aneurysm when heated, is modeled at three discrete stages of the treatment procedure. To estimate an upper bound for the maximum amount of thermal damage due to foam heating, a steady velocity is specified through the basilar artery, corresponding to a minimum physiological flow velocity over a cardiac cycle. During expansion, the foam alters the flow patterns within the aneurysm by shielding the aneurysm dome from a confined jet that issues from the basilar artery. The time scales for thermal damage to the artery walls and surrounding blood flow are computed from the temperature field. The flow through the post-treatment bifurcation is comprised of two counter-rotating vortex tubes that are located beneath the aneurysm neck and extend downstream into the outlet arteries. Beneath the aneurysm neck, a marked increase in the wall shear stress is observed due to the close proximity of the counter-rotating vortex tubes to the artery wall.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Fundamentals of heat and mass transfer
Hewitt, G. F. (2008) · Begellhouse eBooks · Cited by 12,932
Fundamentals of heat and mass transfer
Larkin, A. V. (2018) · BSU Digital Library (Belarusian State University) · Cited by 8,034
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Biodegradable, Elastic Shape-Memory Polymers for Potential Biomedical Applications
Lendlein, A., & Langer, R. (2002) · Science · doi:10.1126/science.1066102 · Cited by 2,146
Fung, Y.-C. (1993) · Springer eBooks · doi:10.1007/978-1-4757-2257-4 · Cited by 2,051
Optical-Thermal Response of Laser-Irradiated Tissue
(2011) · Springer eBooks · doi:10.1007/978-90-481-8831-4 · Cited by 1,424
Elementary Numerical Analysis.
G., W., & Atkinson, K. (1994) · Mathematics of Computation · doi:10.2307/2153423 · Cited by 1,253
Acute Vascular Endothelial Changes Associated with Increased Blood Velocity Gradients
FRY, D. L. (1968) · Circulation Research · doi:10.1161/01.res.22.2.165 · Cited by 1,238
Balloon catheterization and occlusion of major cerebral vessels
Serbinenko, F. A. (1974) · Journal of Neurosurgery · doi:10.3171/jns.1974.41.2.0125 · Cited by 955
Viñuela, F., Duckwiler, G., & Mawad, M. (1997) · Journal of Neurosurgery · doi:10.3171/jns.1997.86.3.0475 · Cited by 875
Cho, Y. I., & Kensey, K. R. (1991) · Biorheology · doi:10.3233/bir-1991-283-415 · Cited by 823
On coherent-vortex identification in turbulence
Dubief †, Y., & Delcayre ‡, F. (2000) · Journal of Turbulence · doi:10.1088/1468-5248/1/1/011 · Cited by 787
Biomechanics: Mechanical Properties of Living Tissues, 2nd ed.
Fung, Y. C., & Cowin, S. C. (1994) · Journal of Applied Mechanics · doi:10.1115/1.2901550 · Cited by 745
Non-Newtonian blood flow in human right coronary arteries: steady state simulations
Johnston, B. M., Johnston, P. R., Corney, S., & Kilpatrick, D. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.09.016 · Cited by 689
Real-time 3D image registration for functional MRI
Cox, R. W., & Jesmanowicz, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199912)42:6<1014::aid-mrm4>3.0.co;2-f · Cited by 663
PATHOLOGIC ANALYSIS OF PHOTOTHERMAL AND PHOTOMECHANICAL EFFECTS OF LASER–TISSUE INTERACTIONS
Thomsen, S. (1991) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1991.tb09897.x · Cited by 585
Fernández‐Zubillaga, A., Guglielmi, G., Viñuela, F., & Duckwiler, G. (1994) · PubMed Central · Cited by 530
Perktold, K., & Rappitsch, G. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)95273-8 · Cited by 493
Er:YAG laser ablation of tissue: Effect of pulse duration and tissue type on thermal damage
Walsh, J. T., Flotte, T. J., & Deutsch, T. F. (1989) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900090403 · Cited by 478
Physical factors in the initiation, growth, and rupture of human intracranial saccular aneurysms
Ferguson, G. G. (1972) · Journal of Neurosurgery · doi:10.3171/jns.1972.37.6.0666 · Cited by 442
Treatment of 54 traumatic carotid-cavernous fistulas
Debrun, G., Lacour, P., Vinuela, F., Fox, A., Drake, C. G., & Caron, J. P. (1981) · Journal of Neurosurgery · doi:10.3171/jns.1981.55.5.0678 · Cited by 410
Viscosity of normal human blood under normothermic and hypothermic conditions
Rand, P. W., Lacombe, E., Hunt, H. E., & Austin, W. H. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.1.117 · Cited by 334
Cold hibernated elastic memory foams for endovascular interventions
Metcalfe, A., Desfaits, A.-C., Salazkin, I., Yahia, L., Sokolowski, W. M., & Raymond, J. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00362-9 · Cited by 307
Intracranial berry aneurysms: angiographic and clinical results after endovascular treatment.
Cognard, C., Weill, A., Castaings, L., Rey, A., & Moret, J. (1998) · Radiology · doi:10.1148/radiology.206.2.9457205 · Cited by 296
Zhao, S. Z., Xu, X. Y., Hughes, A. D., Thom, S. A., Stanton, A. V., Ariff, B., & Long, Q. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00043-9 · Cited by 289
Turbulent structures in accelerating boundary layers
Piomelli †, U., Balaras, E., & Pascarelli, A. (2000) · Journal of Turbulence · doi:10.1088/1468-5248/1/1/001 · Cited by 277
Topology of fine-scale motions in turbulent channel flow
Blackburn, H. M., Mansour, N. N., & Cantwell, B. J. (1996) · Journal of Fluid Mechanics · doi:10.1017/s0022112096001802 · Cited by 273
Rate Process Analysis of Thermal Damage
Pearce, J., & Thomsen, S. (1995) · Optical-Thermal Response of Laser-Irradiated Tissue · doi:10.1007/978-1-4757-6092-7_17 · Cited by 270
Rheology of Human Blood, near and at Zero Flow
Merrill, E. W., Gilliland, E. R., Cokelet, G., Shin, H., Britten, A., & Wells, R. E. (1963) · Biophysical Journal · doi:10.1016/s0006-3495(63)86816-2 · Cited by 237
Impact of nonlinear heat transfer on temperature control in regional hyperthermia
Lang, J., Erdmann, B., & Seebass, M. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.784145 · Cited by 233
Simulation of non-Newtonian blood flow in an end-to-side anastomosis
Ballyk, P. D., Steinman, D. A., & Ethier, C. R. (1994) · Biorheology · doi:10.3233/bir-1994-31505 · Cited by 202
Hematocrit, Volume Expander, Temperature, and Shear Rate Effects on Blood Viscosity
Eckmann, D. M., Bowers, S., Stecker, M. M., & Cheung, A. T. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200009000-00007 · Cited by 199
Blood viscosity and blood pressure: role of temperature and hyperglycemia
Çinar, Y. (2001) · American Journal of Hypertension · doi:10.1016/s0895-7061(00)01260-7 · Cited by 190
Elastodynamics and Arterial Wall Stress
Humphrey, J. D., & Na, S. (2002) · Annals of Biomedical Engineering · doi:10.1114/1.1467676 · Cited by 190
Bammer, R., Hope, T. A., Aksoy, M., & Alley, M. T. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21109 · Cited by 169
Thermal Conductivity and Thermal Diffusivity of Biomaterials: A Simultaneous Measurement Technique
Balasubramaniam, T. A., & Bowman, H. F. (1977) · Journal of Biomechanical Engineering · doi:10.1115/1.3426282 · Cited by 156
Comparative hemorheology—Hematological implications of species differences in blood viscosity
Chien, S., Usami, S., Dellenback, R. J., & Bryant, C. A. (1971) · Biorheology · doi:10.3233/bir-1971-8106 · Cited by 145
Analysis of changes in MR properties of tissues after heat treatment
Graham, S. J., Stanisz, G. J., Kecojević, A., Bronskill, M. J., & Henkelman, R. M. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199912)42:6<1061::aid-mrm10>3.0.co;2-t · Cited by 142
Cokelet, G. R. (1963) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 141
Raftopoulos, C., Mathurin, P., Boscherini, D., Billa, R. F., Boven, M. V., & Hantson, P. E. (2000) · Journal of neurosurgery · doi:10.3171/jns.2000.93.2.0175 · Cited by 130
Enlargement of basilar artery aneurysms following balloon occlusion — “water-hammer effect”
Kwan, E. S. K., Heilman, C. B., Shucart, W. A., & Klucznik, R. (1991) · Journal of neurosurgery · doi:10.3171/jns.1991.75.6.0963 · Cited by 129
Small, W., Buckley, P. R., Wilson, T. S., Benett, W. J., Hartman, J., Saloner, D., & Maitland, D. J. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889771 · Cited by 124
Self-citationMurayama, Y., Viñuela, F., Tateshima, S., Viñuela, F., & Akiba, Y. (2000) · PubMed Central · Cited by 123
Cloft, H. J., Joseph, G. J., Tong, F. C., Goldstein, J. H., & Dion, J. E. (2000) · PubMed Central · Cited by 122
Rate process model for arterial tissue thermal damage: Implications on vessel photocoagulation
Agah, R., Pearce, J. A., Welch, A. J., & Motamedi, M. (1994) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900150205 · Cited by 118
Fluid-Structure Interaction Effects on Sac-Blood Pressure and Wall Stress in a Stented Aneurysm
Li, Z., & Kleinstreuer, C. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.1934040 · Cited by 106
Topology of flow patterns in vortex motions and turbulence
Perry, A. E., & Chong, M. S. (1994) · Flow Turbulence and Combustion · doi:10.1007/bf00849110 · Cited by 106
An analysis of the geometry of saccular intracranial aneurysms.
Parlea, L., Fahrig, R., Holdsworth, D. W., & Lownie, S. P. (1999) · PubMed Central · Cited by 103
Directional Wall Strength in Saccular Brain Aneurysms from Polarized Light Microscopy
MacDonald, D. J., Finlay, H. M., & Canham, P. B. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.292 · Cited by 97
The Effect of Compliance on Wall Shear in Casts of a Human Aortic Bifurcation
Duncan, D. D., Bargeron, C. B., Borchardt, S. E., Deters, O. J., Gearhart, S. A., Mark, F. F., & Friedman, M. H. (1990) · Journal of Biomechanical Engineering · doi:10.1115/1.2891170 · Cited by 92
Topology of Flow Patterns in Vortex Motions and Turbulence
Perry, A. E., & Chong, M. S. (1993) · Fluid mechanics and its applications · doi:10.1007/978-94-011-2098-2_29 · Cited by 87
Detailed Characteristics of the Flow of Blood In Vitro
Bugliarello, G., & Hayden, J. W. (1963) · Transactions of the Society of Rheology · doi:10.1122/1.548964 · Cited by 84 · cited 1×
“Estimates of the time scales for thermal damage to the surrounding blood flow can be obtained by using Eq. ( 12 ), in which the values of Af and Ea are taken to be 7.6 · 10 66 s -1 and 4.48 · 10 5 J/mol, respectively, for whole human blood.”
BackgroundInfluentialGroden, C., Laudan, J., Gatchell, S., & Zeumer, H. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200112000-00011 · Cited by 82
Kallmes, D. F., Williams, A. D., Cloft, H. J., Lopes, M. B. S., Hankins, G. R., & Helm, G. A. (1998) · Radiology · doi:10.1148/radiology.207.2.9577504 · Cited by 82
Hemodynamic stress in lateral saccular aneurysms
Liepsch, D. W., Steiger, H. J., Poll, A., & Reulen, H.-J. (1987) · Biorheology · doi:10.3233/bir-1987-24621 · Cited by 82
Changes in Optical Properties of Human Whole Blood in vitro Due to Slow Heating
Nilsson, A. M. K., Lucassen, G. W., Verkruysse, W., Andersson‐Engels, S., & van Gemert, M. J. C. (1997) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1997.tb08572.x · Cited by 73
Murayama, Y., Viñuela, F. V., Suzuki, Y., Akiba, Y., Ulihoa, A., Duckwiler, G., Gobin, Y. P., Vinters, H. V., Iwaki, M., & Abe, T. (1999) · PubMed Central · Cited by 72
Platinum coil coatings to increase thrombogenicity: a preliminary study in rabbits.
Ahuja, A., Hergenrother, R. W., Strother, C. M., Rappe, A. H., Cooper, S. L., & GRAVES, V. B. (1993) · PubMed Central · Cited by 63
Small, W., Wilson, T. S., Buckley, P. R., Benett, W. J., Loge, J. M., Hartman, J., & Maitland, D. J. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.892921 · Cited by 61
Self-citationPulsed Laser-Induced Thermal Damage in Whole Blood
Pfefer, T. J., Choi, B., Vargas, G., McNally, K. M., & Welch, A. J. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.429642 · Cited by 56
The effect of temperature on the relative viscosity of human blood
Barbee, J. H. (1973) · Biorheology · doi:10.3233/bir-1973-10101 · Cited by 53
Haemodynamic stress in lateral saccular aneurysms
Steiger, H. J., Poll, A., Liepsch, D. W., & Reulen, H.-J. (1987) · Acta Neurochirurgica · doi:10.1007/bf01402292 · Cited by 52
Tamatani, S., Ozawa, T., Minakawa, T., Takeuchi, S., Koike, T., & Tanaka, R. (1997) · Journal of neurosurgery · doi:10.3171/jns.1997.86.1.0109 · Cited by 49
Boecher-Schwarz, H. G., Ringel, K., Kopacz, L., Heimann, A., & Kempski, O. S. (2000) · PubMed Central · Cited by 48
Radiopaque solidifying liquids for releasable balloon technique: a technical note.
Taki, W., Handa, H., Yamagata, S., Ishikawa, M., Iwata, H., & Ikada, Y. (1980) · PubMed · Cited by 47
Kallmes, D. F., Borland, M., Cloft, H. J., Altes, T. A., Dion, J. E., Jensen, M. E., Hankins, G. R., & Helm, G. A. (1998) · Radiology · doi:10.1148/radiology.206.1.9423678 · Cited by 46
In vitro effects of argon laser radiation on blood: Quantitative and morphologic analysis
Abela, G. S., Crea, F., Smith, W. B., Pepine, C. J., & Conti, C. R. (1985) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(85)80042-5 · Cited by 45
Horowitz, M., Samson, D. S., & Purdy, P. D. (1997) · PubMed Central · Cited by 42
Electromagnetic and heat transfer computations for non-ionizing radiation dosimetry
Samaras, T., Regli, P., & Kuster, N. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/8/312 · Cited by 37
Balloon embolization of a giant aneurysm using a newly developed catheter.
Taki, W., Handa, H., Yamagata, S., Matsuda, I., Yonekawa, Y., Ikada, Y., & Iwata, H. (1979) · PubMed · Cited by 35
Therapeutic embolization for vascular trauma of the head and neck.
Mehringer, C. M., Hieshima, G. B., Grinnell, V. S., Tsai, F. Y., Bentson, J. R., Hasso, A. N., Thompson, J. R., Strother, C. M., & Pribram, H. F. W. (1983) · PubMed Central · Cited by 34
Volume and density changes of biological fluids with temperature
Hinghofer-Szalkay, H. G. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.59.6.1686 · Cited by 31
(2007) · PubMed Central · Cited by 24
Self-citationLaser surgery in enclosed spaces: A review
Macruz, R., Ribeiro, M. P., Brum, J. M., Pasqualucci, C. A., Mnitentag, J., Bozinis, D. G., Marques, E., Jatene, A. D., Décourt, L. V., & ARMELIN, E. (1985) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900050303 · Cited by 24
Tong, F. C., Cloft, H. J., & Dion, J. E. (2000) · Journal of Clinical Neuroscience · doi:10.1054/jocn.1999.0211 · Cited by 22
Evolution of endovascular therapy for aneurysm treatment
Kanaan, Y., Kaneshiro, D., Fraser, K., Wang, D., & Lanzino, G. S. (2005) · Neurosurgical FOCUS · doi:10.3171/foc.2005.18.2.3 · Cited by 15
Detachable coils to treat intracranial aneurysms.
Willinsky, R. A. (1999) · Europe PMC (PubMed Central) · Cited by 10
Deflation of metrizamide-filled balloon used to occlude a carotid-cavernous fistula
Leipzig, T. J., & Mullan, S. F. (1983) · Journal of neurosurgery · doi:10.3171/jns.1983.59.3.0524 · Cited by 7
Thermal-perfusion balloon coronary angioplasty: In vivo evaluation
Buller, C. E. H., Culp, S. C., Sketch, M. H., Phillips, H. R., Virmani, R., & Stack, R. S. (1993) · American Heart Journal · doi:10.1016/0002-8703(93)90079-o · Cited by 7
Heat-induced changes in optical properties of human whole blood in vitro
Baranov, V. Y., Chekhov, D. I., Leonov, A. G., Leonov, P. G., Ryaboshapka, O. M., Semenov, S. Y., Splinter, R., Svenson, R. H., & Tatsis, G. P. (1999) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.348378 · Cited by 6
Matrix: new bio-absorbable polymeric coils for the treatment of intracranial aneurysms
Murayama, Y., Viñuela, F. V., & Tateshima, S. (2002) · International Congress Series · doi:10.1016/s0531-5131(02)01039-7 · Cited by 4
Neumann, F.-J., Schmid-Schönbein, H., & Malotta, H. (1987) · Biorheology · doi:10.3233/bir-1987-24504 · Cited by 2
Research works printed but not linked: 5
- Azuma T. (1964) The flow through blood vessels. Biorheology 2:159-161
- Nicoud, F. Hemodynamic changes induced by stenting in elastic arteries. Center for Turbulence Research. Ann. Res. Briefs, pp. 335–347
- Stuhne, G. R., and D. A. Steinman. Mesh resolution requirements for the numerical simulation of flow through stented aneurysms. Summer Bioengineering Conference, June 25–29, Sonesta Beach Resort, Key Biscayne, Florida, 2003
- Sundukov A. N., Postnikova M. A., Zvereva K. V., Ivanov P. A. (1978) Thermal factors involved in rheology of blood of healthy persons and of persons suffering from myocardial infarcts. Heat Transfer–Soviet Res. 10:94–97
- Valvano J. W., Chitsabesan B. (1987) Thermal conductivity and diffusivity of arterial wall and atherosclerotic plaque. Lasers Life Sci. 1(3):219–229
Cited by
A Review of Shape Memory Polymers and Composites: Mechanisms, Materials, and Applications
Xia, Y., He, Y., Zhang, F., Liu, Y., & Leng, J. (2021) · Advanced Materials · doi:10.1002/adma.202000713 · Cited by 1,281
Shape-memory polymers as a technology platform for biomedical applications
Lendlein, A., Behl, M., Hiebl, B., & Wischke, C. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.8 · Cited by 469
Biomedical applications of thermally activated shape memory polymers
Small, IV, Singhal, P., Wilson, T. S., & Maitland, D. J. (2010) · Journal of Materials Chemistry · doi:10.1039/b923717h · Cited by 450
Self-citationZhang, D., George, O. J., Petersen, K. M., Jimenez-Vergara, A. C., Hahn, M. S., & Grunlan, M. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.020 · Cited by 217
A Review on Additive Manufacturing of Shape-Memory Materials for Biomedical Applications
Sabahi, N., Chen, W., Wang, C.-H., Kruzic, J. J., & Li, X. (2020) · JOM · doi:10.1007/s11837-020-04013-x · Cited by 195
Metadata
- Authors
- Ortega, J., Maitland, D., Wilson, T., Tsai, W., Savaş, Ö., & Saloner, D.
- Affiliations
- Lawrence Livermore National Laboratory (US)
- University of California, Berkeley (US)
- University of California, San Francisco (US)
- Corresponding author
- Ortega, Jason
- Venue
- Annals of Biomedical Engineering
- Published
- 2007-08-04
- Volume
- 35
- Issue
- 11
- Pages
- 1870-1884
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2029134564
- Cited by
- 57
- References
- 84
- Citations by year
- 2025: 2 · 2024: 2 · 2023: 1 · 2022: 4 · 2021: 3 · 2020: 4 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 5 · 2015: 3 · 2014: 4 · 2013: 5 · 2012: 5
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Annals of Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Biomedical Imaging and Bioengineering (R01EB000462)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Intracranial Aneurysms: Treatment and Complications
- Health Sciences › Medicine › Surgery › Aortic aneurysm repair treatments
- Health Sciences › Medicine › Surgery › Abdominal vascular conditions and treatments
- Keywords
- shape memory polymer foam, aneurysm treatment, basilar artery aneurysm, vascular dynamics, thermal damage, heat transfer, fluid-structure interaction, wall shear stress, jet flow, bifurcation flow
- MeSH terms
- Basilar Artery, Blood Flow Velocity, Intracranial Aneurysm, Computer Simulation, Humans, Models, Cardiovascular, Polymers, Stress, Mechanical, Temperature
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.