Measuring Head Kinematics in Football: Correlation Between the Head Impact Telemetry System and Hybrid III Headform

Open access
Beckwith, Jonathan G., Greenwald, Richard M., Chu, Jeffrey J. · 2012 · Annals of Biomedical Engineering
Cited by 204

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Abstract

Over the last decade, advances in technology have enabled researchers to evaluate concussion biomechanics through measurement of head impacts sustained during play using two primary methods: (1) laboratory reconstruction of open-field head contact, and (2) instrumented helmets. The purpose of this study was to correlate measures of head kinematics recorded by the Head Impact Telemetry (HIT) System (Simbex, NH) with those obtained from a Hybrid III (HIII) anthropometric headform under conditions that mimicked impacts occurring in the NFL. Linear regression analysis was performed to correlate peak linear acceleration, peak rotational acceleration, Gadd Severity Index (GSI), and Head Injury Criterion (HIC15) obtained from the instrumented helmet and HIII. The average absolute location error between instrumented helmet impact location and the direction of HIII head linear acceleration were also calculated. The HIT System overestimated Hybrid III peak linear acceleration by 0.9% and underestimated peak rotational acceleration by 6.1% for impact sites and velocities previously identified by the NFL as occurring during play. Acceleration measures for all impacts were correlated; however, linear was higher (r2 = 0.903) than rotational (r2 = 0.528) primarily due to lower HIT System rotational acceleration estimates at the frontal facemask test site. Severity measures GSI and HIC were also found to be correlated, albeit less than peak linear acceleration, with the overall difference between the two systems being less than 6.1% for either measure. Mean absolute impact location difference between systems was 31.2 ± 46.3° (approximately 0.038 ± 0.050 m), which was less than the diameter of the impactor surface in the test. In instances of severe helmet deflection (2.54–7.62 cm off the head), the instrumented helmet accurately measured impact location but overpredicted all severity metrics recorded by the HIII. Results from this study indicate that measurements from the two methods of study are correlated and provide a link that can be used to better interpret findings from future study using either technology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s10439-011-0422-2

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 204

Metadata

Authors
Beckwith, J. G., Greenwald, R. M., & Chu, J. J.
Venue
Annals of Biomedical Engineering
Published
2011-10-13
Volume
40
Issue
1
Pages
237-248
ISSN
  • 0090-6964 (ISSN-L)
  • 1573-9686
OpenAlex
W2088840312
Cited by
204
References
42
FWCI
10.64
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.