Fluorescence Lifetime Techniques in Medical Applications
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
This article presents an overview of time-resolved (lifetime) fluorescence techniques used in biomedical diagnostics. In particular, we review the development of time-resolved fluorescence spectroscopy (TRFS) and fluorescence lifetime imaging (FLIM) instrumentation and associated methodologies which allow in vivo characterization and diagnosis of biological tissues. Emphasis is placed on the translational research potential of these techniques and on evaluating whether intrinsic fluorescence signals provide useful contrast for the diagnosis of human diseases including cancer (gastrointestinal tract, lung, head and neck, and brain), skin and eye diseases, and atherosclerotic cardiovascular disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Principles of Fluorescence Spectroscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-46312-4 · Cited by 19,339
Naghavi, M., Libby, P., Falk, E., Casscells, S. W., Litovsky, S., Rumberger, J., Badimon, J. J., Stefanadis, C., Moreno, P., Pasterkamp, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000087481.55887.c9 · Cited by 2,668
Fluorescence Lifetime Measurements and Biological Imaging
Berezin, M. Y., & Achilefu, S. (2010) · Chemical Reviews · doi:10.1021/cr900343z · Cited by 2,403
Naghavi, M., Libby, P., Falk, E., Casscells, S. W., Litovsky, S., Rumberger, J., Badimon, J. J., Stefanadis, C., Moreno, P., Pasterkamp, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000087480.94275.97 · Cited by 2,270
New Strategies for Fluorescent Probe Design in Medical Diagnostic Imaging
Kobayashi, H., Ogawa, M., Alford, R., Choyke, P. L., & Urano, Y. (2010) · Chemical Reviews · doi:10.1021/cr900263j · Cited by 2,200
Zipfel, W. R., Williams, R. M., Christie, R., Nikitin, A. Y., Hyman, B. T., & Webb, W. W. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832308100 · Cited by 1,676
QUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSIS
Richards-Kortum, R., & Sevick-Muraca, E. (1996) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.47.1.555 · Cited by 1,172
In Vivo Fluorescence Spectroscopy and Imaging for Oncological Applications
Wagnieres, G. A., Star, W. M., & Wilson, B. C. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb02521.x · Cited by 942
Fluorescence assay in biology and medicine
Udenfriend, S. (1962) · Medical Entomology and Zoology · Cited by 772
Fluorescence Spectroscopy of Neoplastic and Non-Neoplastic Tissues
Ramanujam, N. (2000) · Neoplasia · doi:10.1038/sj.neo.7900077 · Cited by 654
Stabilization of atherosclerotic plaques: New mechanisms and clinical targets
Libby, P., & Aikawa, M. (2002) · Nature Medicine · doi:10.1038/nm1102-1257 · Cited by 580
Fiber optic probes for biomedical optical spectroscopy
Utzinger, U., & Richards-Kortum, R. R. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528207 · Cited by 443
Multiphoton excitation fluorescence microscopy and spectroscopy of in vivo human skin
Masters, B. R., So, P. T., & Gratton, E. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78886-6 · Cited by 439
Bigio, I. J., & Mourant, J. R. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/5/005 · Cited by 373
Deconvolution of fluorescence decay curves. A critical comparison of techniques
O'Connor, D. V., Ware, W. R., & André, J. (1979) · The Journal of Physical Chemistry · doi:10.1021/j100473a019 · Cited by 344
Clinical multiphoton tomography
König, K. (2008) · Journal of Biophotonics · doi:10.1002/jbio.200710022 · Cited by 303
In vivo assessment of human skin aging by multiphoton laser scanning tomography
Koehler, M. J., König, K., Elsner, P., Bückle, R., & Kaatz, M. (2006) · Optics Letters · doi:10.1364/ol.31.002879 · Cited by 280
Handbook of Biomedical Fluorescence
(2003) · CRC Press eBooks · doi:10.1201/9780203912096 · Cited by 265
Time-resolved fluorescence imaging in biology and medicine
Cubeddu, R., Comelli, D., D'Andrea, C., Taroni, P., & Valentini, G. (2002) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/35/9/201 · Cited by 251
In vivo fluorescence imaging for tissue diagnostics
Andersson-Engels, S., Klinteberg, C. A., Svanberg, K., & Svanberg, S. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/5/006 · Cited by 245
Dimitrow, E., Ziemer, M., Koehler, M. J., Norgauer, J., König, K., Elsner, P., & Kaatz, M. (2009) · Journal of Investigative Dermatology · doi:10.1038/jid.2008.439 · Cited by 242
In vivo Fluorescence Spectroscopy of Nonmelanoma Skin Cancer¶
Brancaleon, L., Durkin, A. J., Tu, J. H., Menaker, G. M., Fallon, J. D., & Kollias, N. (2001) · Photochemistry and Photobiology · doi:10.1562/0031-8655(2001)0730178ivfson2.0.co2 · Cited by 200
Intravascular Modalities for Detection of Vulnerable Plaque: Current Status
MacNeill, B. D., Lowe, H. C., Takano, M., Fuster, V., & Jang, I.-K. (2003) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000080948.08888.bf · Cited by 192
Chorvat, D., & Chorvatova, A. (2009) · Laser Physics Letters · doi:10.1002/lapl.200810132 · Cited by 182
Optical imaging for cervical cancer detection: solutions for a continuing global problem
Thekkek, N., & Richards-Kortum, R. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2462 · Cited by 176
Dimitrow, E., Riemann, I., Ehlers, A., Koehler, M. J., Norgauer, J., Elsner, P., König, K., & Kaatz, M. (2009) · Experimental Dermatology · doi:10.1111/j.1600-0625.2008.00815.x · Cited by 174
Confocal microscopy and multi-photon excitation microscopy of human skin in vivo
Masters, B. R., & So, P. T. C. (2001) · Optics Express · doi:10.1364/oe.8.000002 · Cited by 172
Fluorescence lifetime imaging microscopy for brain tumor image-guided surgery
Hatami, N. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3486612 · Cited by 171
Roberts, M. S., Dancik, Y., Prow, T. W., Thorling, C. A., Lin, L. L., Grice, J. E., Robertson, T. A., König, K., & Becker, W. (2011) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2010.12.023 · Cited by 170
Multispectral optical imaging device for in vivo detection of oral neoplasia
Roblyer, D., Richards-Kortum, R., Sokolov, K., El-Naggar, A. K., Williams, M. D., Kurachi, C., & Gillenwater, A. M. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2904658 · Cited by 167
Clinical two‐photon microendoscopy
König, K., Ehlers, A., Riemann, I., Schenkl, S., Bückle, R., & Kaatz, M. (2007) · Microscopy Research and Technique · doi:10.1002/jemt.20445 · Cited by 165
In vivo measurement of time-resolved autofluorescence at the human fundus
Schweitzer, D., Hammer, M., Schweitzer, F., Anders, R., Doebbecke, T., Schenke, S., Gaillard, E. R., & Gaillard, E. R. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1806833 · Cited by 152
Fluorescence spectroscopy of skin
Kollias, N., Zonios, G. I., & Stamatas, G. N. (2002) · Vibrational Spectroscopy · doi:10.1016/s0924-2031(01)00142-4 · Cited by 141
Review of Neurosurgical Fluorescence Imaging Methodologies
Pogue, B. W., Gibbs‐Strauss, S. L., Valdes, P. A., Samkoe, K. S., Roberts, D. W., & Paulsen, K. D. (2010) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2009.2034541 · Cited by 141
Fluorescence lifetime imaging microscopy: in vivo application to diagnosis of oral carcinoma
Sun, Y. H., Phipps, J. E., Elson, D. S., Stoy, H., Tinling, S. P., Meier, J. D., Poirier, B., Chuang, F. Y. S., Farwell, D. G., & Marcu, L. (2009) · Optics Letters · doi:10.1364/ol.34.002081 · Cited by 133
Self-citationSkin color independent assessment of aging using skin autofluorescence
Koetsier, M., Nur, E., Chunmao, H., Lutgers, H. L., Links, T. P., Smit, A. J., Rakhorst, G., & Graaff, R. (2010) · Optics Express · doi:10.1364/oe.18.014416 · Cited by 125
Keller, M. D., Majumder, S. K., Kelley, M. C., Meszoely, I. M., Boulos, F. I., Olivares, G. M., & Mahadevan-Jansen, A. M. (2010) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20865 · Cited by 122
Fluorescence lifetime spectroscopy for guided therapy of brain tumors
Butte, P. V., Mamelak, A. N., Nuño, M., Bannykh, S., Black, K. L., & Marcu, L. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.001 · Cited by 113
Self-citationOptical Spectroscopy and Imaging for the Noninvasive Evaluation of Engineered Tissues
Georgakoudi, I., Rice, W. L., Hronik‐Tupaj, M., & Kaplan, D. L. (2008) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2008.0248 · Cited by 113
INTRAOPERATIVE OPTICAL SPECTROSCOPY IDENTIFIES INFILTRATING GLIOMA MARGINS WITH HIGH SENSITIVITY
Toms, S. A., Lin, W., Weil, R. J., Johnson, M. D., Jansen, D., & Mahadevan-Jansen, A. M. (2007) · Neurosurgery · doi:10.1227/01.neu.0000279226.68751.21 · Cited by 106
Wide-field fluorescence lifetime imaging of cancer
McGinty, J., Galletly, N. P., Dunsby, C. W., Munro, I., Elson, D. S., Requejo‐Isidro, J., Cohen, P., Ahmad, R., Forsyth, A., Thillainayagam, A. V., et al. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000627 · Cited by 106
Optical touch pointer for fluorescence guided glioblastoma resection using 5‐aminolevulinic acid
Haj‐Hosseini, N., Richter, J., Andersson‐Engels, S., & Wårdell, K. (2010) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20868 · Cited by 100
Pilot clinical study for quantitative spectral diagnosis of non‐melanoma skin cancer
Rajaram, N., Reichenberg, J. S., Migden, M. R., Nguyen, T. H., & Tunnell, J. W. (2010) · Lasers in Surgery and Medicine · doi:10.1002/lsm.21009 · Cited by 86
Frontiers in Intravascular Imaging Technologies
Honda, Y., & Fitzgerald, P. J. (2008) · Circulation · doi:10.1161/circulationaha.105.551804 · Cited by 85
Zellweger, M., Grosjean, P., Goujon, D., Monnier, P., van den Bergh, H., & Wagnières, G. (2001) · Journal of Biomedical Optics · doi:10.1117/1.1332774 · Cited by 81
Kumar, S., Dunsby, C., Beule, P. A. A. D., Owen, D. M., Anand, U., Lanigan, P. M. P., Benninger, R. K. P., Davis, D. M., Neil, M. A. A., Anand, P., et al. (2007) · Optics Express · doi:10.1364/oe.15.012548 · Cited by 77
Fluorescence lifetime in cardiovascular diagnostics
Marcu, L. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3327279 · Cited by 60
Self-citationWilson, B. C. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2795688 · Cited by 55
Time-resolved autofluorescence spectroscopy for classifying normal and premalignant oral tissues
Chen, H., Chiang, C., You, C., Hsiao, T., & Wang, C. (2005) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20192 · Cited by 55
Fite, B. Z., Decaris, M. L., Sun, Y. H., Sun, Y., Lam, A., Ho, C., Leach, J. K., & Marcu, L. (2011) · Tissue Engineering Part C Methods · doi:10.1089/ten.tec.2010.0368 · Cited by 52
Self-citationElson, D. S., Jo, J. A., & Marcu, L. (2007) · New Journal of Physics · doi:10.1088/1367-2630/9/5/127 · Cited by 51
Self-citationSchweitzer, D., Quick, S., Schenke, S., Klemm, M., Gehlert, S., Hammer, M., Jentsch, S., & Fischer, J. (2009) · Der Ophthalmologe · doi:10.1007/s00347-009-1975-4 · Cited by 48
Hammer, M., Königsdörffer, E., Liebermann, C., Framme, C., Schuch, G., Schweitzer, D., & Strobel, J. (2007) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-007-0639-9 · Cited by 48
Cárdenas-Turanzas, M., Freeberg, J. A., Benedet, J. L., Atkinson, E. N., Cox, D. D., Richards-Kortum, R. R., MacAulay, C. E., Follen, M. M., & Cantor, S. B. (2007) · Gynecologic Oncology · doi:10.1016/j.ygyno.2007.08.082 · Cited by 47
Sun, Y. H., Sun, Y., Stephens, D. N., Xie, H., Phipps, J. E., Saroufeem, R. M. G., Southard, J. A., Elson, D. S., & Marcu, L. (2011) · Optics Express · doi:10.1364/oe.19.003890 · Cited by 44
Self-citationComparison of ALA- and ALA hexyl-ester-induced PpIX depth distribution in human skin carcinoma
Dögnitz, N., Salomon, D., Zellweger, M., Ballini, J.-P., Gabrecht, T., Lange, N., van den Bergh, H., & Wagnières, G. (2008) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/j.jphotobiol.2008.07.012 · Cited by 39
In vivo time-resolved autofluorescence measurements to test for glycation of human skin
Blackwell, J., Katika, K. M., Pilon, L., Dipple, K. M., Levin, S. R., & Nouvong, A. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2830658 · Cited by 39
Angheloiu, G. O., Arendt, J. T., Müller, M. G., Haka, A. S., Georgakoudi, I., Motz, J. T., Šćepanović, O. R., Kuban, B. D., Myles, J. L., Miller, F., et al. (2006) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/01.atv.0000225699.36212.23 · Cited by 32
Light-induced autofluorescence spectroscopy for tissue diagnosis of GI lesions
Mayinger, B., Horner, P., Jordan, M., Gerlach, C., Horbach, T., Hohenberger, W., & Hahn, E. G. (2000) · Gastrointestinal Endoscopy · doi:10.1067/mge.2000.107219 · Cited by 29
Hüttenberger, D., Gabrecht, T., Wagnières, G., Weber, B.-C., Linder, A., Foth, H. ‐., & Freitag, L. (2008) · Photodiagnosis and Photodynamic Therapy · doi:10.1016/j.pdpdt.2008.05.002 · Cited by 23
New developments in fluorescence diagnostics
Hegyi, J., Hegyi, V., Ruzicka, T., Arenberger, P., & Berking, C. (2011) · JDDG Journal der Deutschen Dermatologischen Gesellschaft · doi:10.1111/j.1610-0387.2011.07582.x · Cited by 15
Cited by
Datta, R., Heaster, T. M., Sharick, J. T., Gillette, A. A., & Skala, M. C. (2020) · Journal of Biomedical Optics · doi:10.1117/1.jbo.25.7.071203 · Cited by 880
Single-photon avalanche diode imagers in biophotonics: review and outlook
Bruschini, C., Homulle, H., Antolovic, I. M., Burri, S., & Charbon, E. (2019) · Light: Science & Applications · doi:10.1038/s41377-019-0191-5 · Cited by 512
Fluorescent labeling and modification of proteins
Toseland, C. P. (2013) · Journal of Chemical Biology · doi:10.1007/s12154-013-0094-5 · Cited by 339
Fluorescence lifetime imaging (FLIM): Basic concepts and some recent developments
Suhling, K., Hirvonen, L. M., Levitt, J. A., Chung, P.-H., Tregidgo, C., Le Marois, A., Rusakov, D. A., Zheng, K., Ameer-Beg, S., Poland, S., et al. (2015) · Medical Photonics · doi:10.1016/j.medpho.2014.12.001 · Cited by 313
Krafft, C., Schmitt, M., Schie, I. W., Cialla‐May, D., Matthäus, C., Bocklitz, T., & Popp, J. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201607604 · Cited by 234
Metadata
- Authors
- Marcu, L.
- Venue
- Annals of Biomedical Engineering
- Published
- 2012-01-25
- Volume
- 40
- Issue
- 2
- Pages
- 304-331
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2018056590
- Cited by
- 257
- References
- 62
- FWCI
- 8.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.