Vascularization in Bone Tissue Engineering Constructs
Open accessThe DOI matches its Crossref record; 113 of the 113 references it cites were found in a registry or an index.
Abstract
Vascularization of large bone grafts is one of the main challenges of bone tissue engineering (BTE), and has held back the clinical translation of engineered bone constructs for two decades so far. The ultimate goal of vascularized BTE constructs is to provide a bone environment rich in functional vascular networks to achieve efficient osseointegration and accelerate restoration of function after implantation. To attain both structural and vascular integration of the grafts, a large number of biomaterials, cells, and biological cues have been evaluated. This review will present biological considerations for bone function restoration, contemporary approaches for clinical salvage of large bone defects and their limitations, state-of-the-art research on the development of vascularized bone constructs, and perspectives on evaluating and implementing novel BTE grafts in clinical practice. Success will depend on achieving full graft integration at multiple hierarchical levels, both between the individual graft components as well as between the implanted constructs and their surrounding host tissues. The paradigm of vascularized tissue constructs could not only revolutionize the progress of BTE, but could also be readily applied to other fields in regenerative medicine for the development of new innovative vascularized tissue designs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
American society for testing and materials
Mather, B., & Etris, S. F. (2006) · Encyclopedia of Earth Science · doi:10.1007/0-387-30720-6_5 · Cited by 5,558
Hydrogels for tissue engineering: scaffold design variables and applications
Drury, J. L., & Mooney, D. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00340-5 · Cited by 5,136
Magnesium and its alloys as orthopedic biomaterials: A review
Staiger, M. P., Pietak, A. M., Huadmai, J., & Dias, G. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.003 · Cited by 4,452
The conflicts between strength and toughness
Ritchie, R. O. (2011) · Nature Materials · doi:10.1038/nmat3115 · Cited by 3,989
Rapid casting of patterned vascular networks for perfusable engineered three-dimensional tissues
Miller, J. S., Stevens, K. R., Yang, M. T., Baker, B. M., Nguyen, D.-H. T., Cohen, D. M., Toro, E., Chen, A. A., Galie, P. A., Yu, X., et al. (2012) · Nature Materials · doi:10.1038/nmat3357 · Cited by 1,917
Osteoinduction, osteoconduction and osseointegration
T., A., & C., J. (2001) · European Spine Journal · doi:10.1007/s005860100282 · Cited by 1,751
The role of pericytes in blood-vessel formation and maintenance
Bergers, G., & Song, S. (2005) · Neuro-Oncology · doi:10.1215/s1152851705000232 · Cited by 1,584
Kumar, G., & Narayan, B. (2014) · Classic Papers in Orthopaedics · doi:10.1007/978-1-4471-5451-8_137 · Cited by 1,454
A completely biological tissue-engineered human blood vessel
L'heureux, N., Pâquet, S., Labbé, R., Germain, L., & Auger, F. A. (1998) · The FASEB Journal · doi:10.1096/fasebj.12.1.47 · Cited by 1,402
ILIZAROV, G. A. (1989) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198902000-00029 · Cited by 1,263
Cited by
Scaffold Fabrication Technologies and Structure/Function Properties in Bone Tissue Engineering
Collins, M. N., Ren, G., Young, K., Pina, S., Reis, R. L., & Oliveira, J. M. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202010609 · Cited by 867
Biofabrication of bone tissue: approaches, challenges and translation for bone regeneration
Tang, D., Tare, R. S., Yang, L.-Y., Williams, D. F., Ou, K.-L., & Oreffo, R. O. C. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.024 · Cited by 613
“1), bioreactors to provide perfusion and mechanical stimuli, the microfabrication of microchannels using AM methods, and biomaterials and growth factors to direct cell behaviour, are being studied [52,53].”
MethodThe role of vasculature in bone development, regeneration and proper systemic functioning
Filipowska, J., Tomaszewski, K. A., Niedźwiedzki, Ł., Walocha, J. A., & Niedźwiedzki, T. (2017) · Angiogenesis · doi:10.1007/s10456-017-9541-1 · Cited by 559
Treatment of critical-sized bone defects: clinical and tissue engineering perspectives
Roddy, E., DeBaun, M. R., Daoud-Gray, A., Yang, Y. P., & Gardner, M. J. (2018) · European Journal of Orthopaedic Surgery & Traumatology · doi:10.1007/s00590-017-2063-0 · Cited by 459
Self-citationBone physiology as inspiration for tissue regenerative therapies
Lopes, D., Martins-Cruz, C., Oliveira, M. B., & Mano, J. F. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.09.028 · Cited by 421
3D Bioprinting for Cartilage and Osteochondral Tissue Engineering
Daly, A. C., Freeman, F. E., Gonzalez‐Fernandez, T., Critchley, S. E., Nulty, J., & Kelly, D. J. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700298 · Cited by 334
Engineering vascularized and innervated bone biomaterials for improved skeletal tissue regeneration
Marrella, A., Lee, T. Y., Lee, D. H., Karuthedom, S., Syla, D., Chawla, A., Khademhosseini, A., & Jang, H. L. (2018) · Materials Today · doi:10.1016/j.mattod.2017.10.005 · Cited by 311
Functional Biomaterials for Bone Regeneration: A Lesson in Complex Biology
Armiento, A. R., Hatt, L. P., Sanchez Rosenberg, G., Thompson, K., & Stoddart, M. J. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201909874 · Cited by 273
Vidal, L., Kampleitner, C., Brennan, M. Á., Hoornaert, A., & Layrolle, P. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00061 · Cited by 239
“Insufficient vascularity of the fracture site reduces the exchange of gas, nutrients and waste between the tissue and the blood system, as well as the delivery of cells to the site of injury, leading to inner graft necrosis (Mercado-Pagan et al., 2015; Fernandez de Grado et al., 2018).”
BackgroundPark, J. Y., Shim, J.-H., Choi, S.-A., Jang, J., Kim, M., Lee, S. H., & Cho, D.-W. (2015) · Journal of Materials Chemistry B · doi:10.1039/c5tb00637f · Cited by 188
Cui, H., Zhu, W., Nowicki, M., Zhou, X., Khademhosseini, A., & Zhang, L. G. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600505 · Cited by 185
Heo, D. N., Hospodiuk, M., & Ozbolat, I. T. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.02.046 · Cited by 175
Regenerative Approaches for the Treatment of Large Bone Defects
Stahl, A., & Yang, Y. P. (2021) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2020.0281 · Cited by 173
Self-citation
Metadata
- Authors
- Mercado-Pagán, Á. E., Stahl, A. M., Shanjani, Y., & Yang, Y.
- Venue
- Annals of Biomedical Engineering
- Published
- 2015-01-24
- Volume
- 43
- Issue
- 3
- Pages
- 718-729
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W1970383231
- Cited by
- 288
- References
- 113
- FWCI
- 12.27
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.