A microfluidic platform for 3-dimensional cell culture and cell-based assays
The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
This paper reports a novel microfluidic platform introducing peptide hydrogel to make biocompatible microenvironment as well as realizing in situ cell-based assays. Collagen composite, OPLA and Puramatrix scaffolds are compared to select good environment for human hepatocellular carcinoma cells (HepG2) by albumin measurement. The selected biocompatible self-assembling peptide hydrogel, Puramatrix, is hydrodynamically focused in the middle of main channel of a microfluidic device, and at the same time the cells are 3-dimensionally immobilized and encapsulated without any additional surface treatment. HepG2 cells have been 3-dimensionally cultured in a poly(dimethylsiloxane) (PDMS) microfluidic device for 4 days. The cells cultured in micro peptide scaffold are compared with those cultured by conventional petri dish in morphology and the rate of albumin secretion. By injection of different reagents into either side of the peptide scaffold, the microfluidic device also forms a linear concentration gradient profile across the peptide scaffold due to molecular diffusion. Based on this characteristic, toxicity tests are performed by Triton X-100. As the higher toxicant concentration gradient forms, the wider dead zone of cells in the peptide scaffold represents. This microfluidic platform facilitates in vivo-like 3-dimensional microenvironment, and have a potential for the applications of reliable cell-based screening and assays including cytotoxicity test, real-time cell viability…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Collagen, collagen-chitosan, Matrigel, and fibrinogen matrices, alginate, Puramatrix scaffolds, and polyethylene glycol matrices have been used to fabricate 3D cell culture biosensors using various cell lines for drug screening, toxicology assays, and cell-biomaterial interaction screening, and for the identification of unknown pathogens and toxins. 80,86,87”
From Three-dimensional cell culture systems and their applications in drug discovery and cell-based biosensors (2014) · cites this paper as [87]
In the citing paper
“This shows that although the relative albumin secreted per cell decreased overtime, the level was sustained within the range (0.6-80 pg/cell/day) reported in the literature for albumin production per cell by HepG2 cells/ spheroids [63,64].”
From A liver-on-a-chip platform with bioprinted hepatic spheroids (2016) · cites this paper as [64]
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Spontaneous assembly of a self-complementary oligopeptide to form a stable macroscopic membrane.
Zhang, S., Holmes, T., Lockshin, C., & Rich, A. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.8.3334 · Cited by 1,304
Abbott, A. (2003) · Nature · doi:10.1038/424870a · Cited by 1,234
Extensive neurite outgrowth and active synapse formation on self-assembling peptide scaffolds
Holmes, T. C., de Lacalle, S., Su, X., Liu, G., Rich, A., & Zhang, S. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.12.6728 · Cited by 1,124
Biomaterials in Tissue Engineering
Hubbell, J. A. (1995) · Nature Biotechnology · doi:10.1038/nbt0695-565 · Cited by 1,060
Li Jeon, N., Baskaran, H., Dertinger, S. K. W., Whitesides, G. M., Van De Water, L., & Toner, M. (2002) · Nature Biotechnology · doi:10.1038/nbt712 · Cited by 917
Generation of Gradients Having Complex Shapes Using Microfluidic Networks
Dertinger, S. K. W., Chiu, D. T., Jeon, N. L., & Whitesides, G. M. (2001) · Analytical Chemistry · doi:10.1021/ac001132d · Cited by 839
Self-complementary oligopeptide matrices support mammalian cell attachment
Zhang, S., Holmes, T. C., DiPersio, C. M., Hynes, R. O., Su, X., & Rich, A. (1995) · Biomaterials · doi:10.1016/0142-9612(95)96874-y · Cited by 680
Dynamic reassembly of peptide RADA16 nanofiber scaffold
Yokoi, H., Kinoshita, T., & Zhang, S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0407843102 · Cited by 679
Human neural stem cell growth and differentiation in a gradient-generating microfluidic device
Chung, B. G., Flanagan, L. A., Rhee, S. W., Schwartz, P. H., Lee, A. P., Monuki, E. S., & Jeon, N. L. (2005) · Lab on a Chip · doi:10.1039/b417651k · Cited by 556
Dynamics of Drosophila embryonic patterning network perturbed in space and time using microfluidics
Lucchetta, E. M., Lee, J. H., Fu, L. A., Patel, N. H., & Ismagilov, R. F. (2005) · Nature · doi:10.1038/nature03509 · Cited by 449
Three-Dimensional Photopatterning of Hydrogels Containing Living Cells
Liu, V. A., & Bhatia, S. N. (2002) · Biomedical Microdevices · doi:10.1023/a:1020932105236 · Cited by 399
Hepatocyte behavior within three-dimensional porous alginate scaffolds
Glicklis, R., Shapiro, L., Agbaria, R., Merchuk, J. C., & Cohen, S. (2000) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(20000205)67:3<283::aid-bit4>3.0.co;2-h · Cited by 391
Hepatocyte behavior within three-dimensional porous alginate scaffolds
Glicklis, R., Shapiro, L., Agbaria, R., Merchuk, J. C., & Cohen, S. (2000) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(20000205)67:3<344::aid-bit11>3.0.co;2-2 · Cited by 391
Microenvironment design considerations for cellular scale studies
Walker, G. M., Zeringue, H. C., & Beebe, D. J. (2004) · Lab on a Chip · doi:10.1039/b311214d · Cited by 388
A sensitive, versatile microfluidic assay for bacterial chemotaxis
Mao, H., Cremer, P. S., & Manson, M. D. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0931258100 · Cited by 332
Cell Culture in 3-Dimensional Microfluidic Structure of PDMS (polydimethylsiloxane)
Leclerc, E., Sakai, Y., & Fujii, T. (2003) · Biomedical Microdevices · doi:10.1023/a:1024583026925 · Cited by 324
Semino, C. E., Merok, J. R., Crane, G. G., Panagiotakos, G., & Zhang, S. (2003) · Differentiation · doi:10.1046/j.1432-0436.2003.7104503.x · Cited by 321
Stability of hydrogels used in cell encapsulation: An in vitro comparison of alginate and agarose
Shoichet, M. S., Li, R. H., White, M. L., & Winn, S. R. (1996) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19960520)50:4<374::aid-bit4>3.0.co;2-i · Cited by 296
Three‐Dimensional Microfluidic Tissue‐Engineering Scaffolds Using a Flexible Biodegradable Polymer
Bettinger, C. J., Weinberg, E. J., Kulig, K. M., Vacanti, J. P., Wang, Y., Borenstein, J. T., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200500438 · Cited by 291
Hung, P. J., Lee, P. J., Sabounchi, P., Aghdam, N., Lin, R., & Lee, L. P. (2005) · Lab on a Chip · doi:10.1039/b410743h · Cited by 259
Bokhari, M. A., Akay, G., Zhang, S., & Birch, M. A. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.01.040 · Cited by 250
Microfluidic PDMS (Polydimethylsiloxane) Bioreactor for Large-Scale Culture of Hepatocytes
Leclerc, E., Sakai, Y., & Fujii, T. (2004) · Biotechnology Progress · doi:10.1021/bp0300568 · Cited by 234
Layer-by-layer microfluidics for biomimetic three-dimensional structures
Tan, W., & Desai, T. A. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.021 · Cited by 193
Mammalian electrophysiology on a microfluidic platform
Ionescu-Zanetti, C., Shaw, R. M., Seo, J., Jan, Y.-N., Jan, L. Y., & Lee, L. P. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503418102 · Cited by 178
Study of osteoblastic cells in a microfluidic environment
Leclerc, E., David, B., Griscom, L., Lepioufle, B., Fujii, T., Layrolle, P., & Legallaisa, C. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.06.002 · Cited by 166
Generating fixed concentration arrays in a microfluidic device
Holden, M. A., Kumar, S., Castellana, E. T., Beskok, A., & Cremer, P. S. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00129-1 · Cited by 161
Combinatorial mixing of microfluidic streams
Neils, C., Tyree, Z., Finlayson, B., & Folch, A. (2004) · Lab Chip · doi:10.1039/b314962e · Cited by 154
Plasma protein adsorption and platelet adhesion onto comb-like PEO gradient surfaces
Lee, J. H., Jeong, B. J., & Lee, H. B. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199701)34:1<105::aid-jbm14>3.0.co;2-j · Cited by 152
Tan, W., & Desai, T. A. (2003) · Tissue Engineering · doi:10.1089/107632703764664729 · Cited by 138
Microfluidic Gradient-Generating Device for Pharmacological Profiling
Pihl, J., Sinclair, J., Sahlin, E., Karlsson, M., Petterson, F., Olofsson, J., & Orwar, O. (2005) · Analytical Chemistry · doi:10.1021/ac050218+ · Cited by 135
Anders, M., Hansen, R., Ding, R.-X., Rauen, K. A., Bissell, M. J., & Korn, W. M. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0337599100 · Cited by 113
Retinal pigment epithelium cells cultured on synthetic biodegradable polymers
Giordano, G. G., Thomson, R. C., Ishaug, S. L., Mikos, A. G., Cumber, S., GARCIA, C. A., & Lahiri-Munir, D. (1997) · Journal of Biomedical Materials Research · Cited by 103
Microscale multilayer cocultures for biomimetic blood vessels
Tan, W., & Desai, T. A. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30182 · Cited by 98
Gentle cell trapping and release on a microfluidic chip by in situ alginate hydrogel formation
Braschler, T., Johann, R., Heule, M., Metref, L., & Renaud, P. (2005) · Lab on a Chip · doi:10.1039/b417604a · Cited by 97
Localized delivery of epidermal growth factor improves the survival of transplanted hepatocytes
Mooney, D. J., Kaufmann, P. M., Sano, K., Schwendeman, S. P., Majahod, K., Schloo, B. L., Vacanti, J. P., & Langer, R. (1996) · Biotechnology and Bioengineering · Cited by 94
Yeon, J. H., & Park, J. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2005.03.047 · Cited by 92
Self-citationCell infection within a microfluidic device using virus gradients
Walker, G. M. (2003) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2003.10.014 · Cited by 90
Moghe, P. V., Coger, R. N., Toner, M., & Yarmush, M. L. (1997) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19971220)56:6<706::aid-bit14>3.0.co;2-5 · Cited by 73
An organic–inorganic hybrid scaffold for the culture of HepG2 cells in a bioreactor
Kataoka, K., Nagao, Y., Nukui, T., Akiyama, I., Tsuru, K., Hayakawa, S., Osaka, A., & Huh, N.-H. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.012 · Cited by 69
Park, T. G. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1224 · Cited by 68
Yang, M., Yang, J., Li, C., & Zhao, J. (2002) · Lab on a Chip · doi:10.1039/b201021f · Cited by 38
Electrokinetic concentration gradient generation using a converging–diverging microchannel
Lee, J. S. H., Hu, Y., & Li, D. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.04.041 · Cited by 32
Kurosawa, H., Yasuda, R., Osano, Y.-K., & Amano, Y. (2001) · Cytotechnology · doi:10.1023/a:1014028617729 · Cited by 7
Research works printed but not linked: 3
- G.G. Giordano, R.C. Thomson, S.L. Ishaug, A.G. Mikos, S. Cumber, C.A. Garcia, and D. Lahiri-Munir, J. Biomed. Mater. Res. 34, 87–93 (1997). · doi:10.1002/(sici)1097-4636(199701)34:1<87::aid-jbm12>3.0.co;2-m
- J.A. Hubbell, Biotechnology 13, 565–576 (1995).
- D.J. Mooney, P.M. Kaufmann, K. Sano, S.P. Schwendeman, K. Majahod, B. Schloo, J.P. Vacanti, and R. Langer, Biotechnol. Bioeng. 50, 422–429 (1996). · doi:10.1002/(sici)1097-0290(19960520)50:4<422::aid-bit9>3.0.co;2-n
Cited by
Edmondson, R., Broglie, J. J., Adcock, A. F., & Yang, L. (2014) · ASSAY and Drug Development Technologies · doi:10.1089/adt.2014.573 · Cited by 2,515
“Collagen, collagen-chitosan, Matrigel, and fibrinogen matrices, alginate, Puramatrix scaffolds, and polyethylene glycol matrices have been used to fabricate 3D cell culture biosensors using various cell lines for drug screening, toxicology assays, and cell-biomaterial interaction screening, and for the identification…”
MethodA liver-on-a-chip platform with bioprinted hepatic spheroids
Bhise, N. S., Manoharan, V., Massa, S., Tamayol, A., Ghaderi, M., Miscuglio, M., Lang, Q., Shrike Zhang, Y., Shin, S. R., Calzone, G., et al. (2016) · Biofabrication · doi:10.1088/1758-5090/8/1/014101 · Cited by 615
A microfluidic device for a pharmacokinetic–pharmacodynamic (PK–PD) model on a chip
Sung, J. H., Kam, C., & Shuler, M. L. (2010) · Lab on a Chip · doi:10.1039/b917763a · Cited by 484
A Review of Three-Dimensional In Vitro Tissue Models for Drug Discovery and Transport Studies
Elliott, N. T., & Yuan, F. (2011) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22257 · Cited by 449
Microfluidic cell culture systems for drug research
Wu, M.-H., Huang, S.-B., & Lee, G.-B. (2010) · Lab on a Chip · doi:10.1039/b921695b · Cited by 432
Metadata
- Authors
- Kim, M. S., Yeon, J. H., & Park, J.-K.
- Affiliations
- Korea Advanced Institute of Science and Technology (KR)
- Corresponding author
- Park, Je-Kyun
- Venue
- Biomedical Microdevices
- Published
- 2006-11-11
- Volume
- 9
- Issue
- 1
- Pages
- 25-34
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W2074854692
- Cited by
- 166
- References
- 41
- Citations by year
- 2026: 1 · 2025: 2 · 2023: 1 · 2022: 2 · 2021: 4 · 2020: 1 · 2019: 4 · 2018: 4 · 2017: 9 · 2016: 10 · 2015: 10 · 2014: 8 · 2013: 13 · 2012: 10
- FWCI
- 9.20
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Biomedical Microdevices (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
- Keywords
- microfluidic platform, 3D cell culture, self-assembling peptide hydrogel, PuraMatrix, cell-based assays, hepatocellular carcinoma cells, HepG2 cells, albumin secretion, hydrodynamic focusing, concentration gradient, cytotoxicity assay, cell viability monitoring, dose-response assay, PDMS microfluidic device
- MeSH terms
- Animals, Biological Assay, Cell Separation, Equipment Design, Flow Cytometry, Micromanipulation, Stress, Mechanical, Flow Injection Analysis, Cell Culture Techniques, Equipment Failure Analysis, Microfluidic Analytical Techniques, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.