A microfluidic platform for 3-dimensional cell culture and cell-based assays
The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
This paper reports a novel microfluidic platform introducing peptide hydrogel to make biocompatible microenvironment as well as realizing in situ cell-based assays. Collagen composite, OPLA and Puramatrix scaffolds are compared to select good environment for human hepatocellular carcinoma cells (HepG2) by albumin measurement. The selected biocompatible self-assembling peptide hydrogel, Puramatrix, is hydrodynamically focused in the middle of main channel of a microfluidic device, and at the same time the cells are 3-dimensionally immobilized and encapsulated without any additional surface treatment. HepG2 cells have been 3-dimensionally cultured in a poly(dimethylsiloxane) (PDMS) microfluidic device for 4 days. The cells cultured in micro peptide scaffold are compared with those cultured by conventional petri dish in morphology and the rate of albumin secretion. By injection of different reagents into either side of the peptide scaffold, the microfluidic device also forms a linear concentration gradient profile across the peptide scaffold due to molecular diffusion. Based on this characteristic, toxicity tests are performed by Triton X-100. As the higher toxicant concentration gradient forms, the wider dead zone of cells in the peptide scaffold represents. This microfluidic platform facilitates in vivo-like 3-dimensional microenvironment, and have a potential for the applications of reliable cell-based screening and assays including cytotoxicity test, real-time cell viability…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Collagen, collagen-chitosan, Matrigel, and fibrinogen matrices, alginate, Puramatrix scaffolds, and polyethylene glycol matrices have been used to fabricate 3D cell culture biosensors using various cell lines for drug screening, toxicology assays, and cell-biomaterial interaction screening, and for the identification of unknown pathogens and toxins. 80,86,87”
From Three-dimensional cell culture systems and their applications in drug discovery and cell-based biosensors (2014) · cites this paper as [87]
In the citing paper
“This shows that although the relative albumin secreted per cell decreased overtime, the level was sustained within the range (0.6-80 pg/cell/day) reported in the literature for albumin production per cell by HepG2 cells/ spheroids [63,64].”
From A liver-on-a-chip platform with bioprinted hepatic spheroids (2016) · cites this paper as [64]
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Spontaneous assembly of a self-complementary oligopeptide to form a stable macroscopic membrane.
Zhang, S., Holmes, T., Lockshin, C., & Rich, A. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.8.3334 · Cited by 1,304
Abbott, A. (2003) · Nature · doi:10.1038/424870a · Cited by 1,234
Extensive neurite outgrowth and active synapse formation on self-assembling peptide scaffolds
Holmes, T. C., de Lacalle, S., Su, X., Liu, G., Rich, A., & Zhang, S. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.12.6728 · Cited by 1,124
Biomaterials in Tissue Engineering
Hubbell, J. A. (1995) · Nature Biotechnology · doi:10.1038/nbt0695-565 · Cited by 1,060
Li Jeon, N., Baskaran, H., Dertinger, S. K. W., Whitesides, G. M., Van De Water, L., & Toner, M. (2002) · Nature Biotechnology · doi:10.1038/nbt712 · Cited by 917
Generation of Gradients Having Complex Shapes Using Microfluidic Networks
Dertinger, S. K. W., Chiu, D. T., Jeon, N. L., & Whitesides, G. M. (2001) · Analytical Chemistry · doi:10.1021/ac001132d · Cited by 839
Self-complementary oligopeptide matrices support mammalian cell attachment
Zhang, S., Holmes, T. C., DiPersio, C. M., Hynes, R. O., Su, X., & Rich, A. (1995) · Biomaterials · doi:10.1016/0142-9612(95)96874-y · Cited by 680
Dynamic reassembly of peptide RADA16 nanofiber scaffold
Yokoi, H., Kinoshita, T., & Zhang, S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0407843102 · Cited by 679
Human neural stem cell growth and differentiation in a gradient-generating microfluidic device
Chung, B. G., Flanagan, L. A., Rhee, S. W., Schwartz, P. H., Lee, A. P., Monuki, E. S., & Jeon, N. L. (2005) · Lab on a Chip · doi:10.1039/b417651k · Cited by 556
Research works printed but not linked: 2
- G.G. Giordano, R.C. Thomson, S.L. Ishaug, A.G. Mikos, S. Cumber, C.A. Garcia, and D. Lahiri-Munir, J. Biomed. Mater. Res. 34, 87–93 (1997). · doi:10.1002/(sici)1097-4636(199701)34:1<87::aid-jbm12>3.0.co;2-m
- J.A. Hubbell, Biotechnology 13, 565–576 (1995).
Cited by
Edmondson, R., Broglie, J. J., Adcock, A. F., & Yang, L. (2014) · ASSAY and Drug Development Technologies · doi:10.1089/adt.2014.573 · Cited by 2,515
“Collagen, collagen-chitosan, Matrigel, and fibrinogen matrices, alginate, Puramatrix scaffolds, and polyethylene glycol matrices have been used to fabricate 3D cell culture biosensors using various cell lines for drug screening, toxicology assays, and cell-biomaterial interaction screening, and for the identification…”
MethodA liver-on-a-chip platform with bioprinted hepatic spheroids
Bhise, N. S., Manoharan, V., Massa, S., Tamayol, A., Ghaderi, M., Miscuglio, M., Lang, Q., Shrike Zhang, Y., Shin, S. R., Calzone, G., et al. (2016) · Biofabrication · doi:10.1088/1758-5090/8/1/014101 · Cited by 615
A microfluidic device for a pharmacokinetic–pharmacodynamic (PK–PD) model on a chip
Sung, J. H., Kam, C., & Shuler, M. L. (2010) · Lab on a Chip · doi:10.1039/b917763a · Cited by 484
A Review of Three-Dimensional In Vitro Tissue Models for Drug Discovery and Transport Studies
Elliott, N. T., & Yuan, F. (2011) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22257 · Cited by 449
Microfluidic cell culture systems for drug research
Wu, M.-H., Huang, S.-B., & Lee, G.-B. (2010) · Lab on a Chip · doi:10.1039/b921695b · Cited by 432
Sung, J. H., & Shuler, M. L. (2009) · Lab on a Chip · doi:10.1039/b901377f · Cited by 431
Microfluidic Devices for Drug Delivery Systems and Drug Screening
Damiati, S., Kompella, U. B., Damiati, S. A., & Kodzius, R. (2018) · Genes · doi:10.3390/genes9020103 · Cited by 383
“Several gel-supported 3D cell cultures in microfluidic devices have been designed using native ECMs such as agarose, collagen, hyaluronic acid, fibronectin, and fibrin [10,149,150].”
BackgroundCell Culture Models in Microfluidic Systems
Meyvantsson, I., & Beebe, D. J. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.113042 · Cited by 345
“created another device that employed laminar flow to create perfusion channels on either side of a gel compartment (24).”
MethodEngineering cancer microenvironments for in vitro 3-D tumor models
Asghar, W., El Assal, R., Shafiee, H., Pitteri, S., Paulmurugan, R., & Demirci, U. (2015) · Materials Today · doi:10.1016/j.mattod.2015.05.002 · Cited by 316
Lee, W., Lee, V., Polio, S., Keegan, P., Lee, J., Fischer, K., Park, J., & Yoo, S. (2010) · Biotechnology and Bioengineering · doi:10.1002/bit.22613 · Cited by 289
“The hydrogel-cell composites mimicking artificial ‘‘mini’’ organs or tissue have also been suggested for use in measuring pharmacological responses (Kim et al., 2007; Lee et al., 2008; Torisawa et al., 2005).”
BackgroundSelf-citationBiofabrication of a three-dimensional liver micro-organ as an in vitro drug metabolism model
Chang, R., Emami, K., Wu, H., & Sun, W. (2010) · Biofabrication · doi:10.1088/1758-5082/2/4/045004 · Cited by 247
Yu, L., Chen, M. C. W., & Cheung, K. C. (2010) · Lab on a Chip · doi:10.1039/c004590j · Cited by 247
3-D Tissue Culture Systems for the Evaluation and Optimization of Nanoparticle-Based Drug Carriers
Goodman, T. T., Ng, C. P., & Pun, S. H. (2008) · Bioconjugate Chemistry · doi:10.1021/bc800233a · Cited by 207
Partitioning microfluidic channels with hydrogel to construct tunable 3-D cellular microenvironments
Wong, A. P., Perez-Castillejos, R., Christopher Love, J., & Whitesides, G. M. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.044 · Cited by 192
A gel-free 3D microfluidic cell culture system
Ong, S.-M., Zhang, C., Toh, Y.-C., Kim, S. H., Foo, H. L., Tan, C. H., van Noort, D., Park, S., & Yu, H. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.022 · Cited by 172
Automated cell culture in high density tubeless microfluidic device arrays
Meyvantsson, I., Warrick, J. W., Hayes, S., Skoien, A., & Beebe, D. J. (2008) · Lab on a Chip · doi:10.1039/b715375a · Cited by 172
Riahi, R., Shaegh, S. A. M., Ghaderi, M., Zhang, Y. S., Shin, S. R., Aleman, J., Massa, S., Kim, D., Dokmeci, M. R., & Khademhosseini, A. (2016) · Scientific Reports · doi:10.1038/srep24598 · Cited by 172
“Importantly, the developed EC immunosensor could measure average TF concentrations of 5.8, 10.8, and 14.5 μg/day/10 6 cells for Days 1, 3, and 5, in agreement with the results reported in the literature for HepG2 cells (0.1–17.2 μg/day/10 6 cells) 33–36 .”
ResultInfluentialNanomaterial processing using self-assembly-bottom-up chemical and biological approaches
Thiruvengadathan, R., Korampally, V., Ghosh, A., Chanda, N., Gangopadhyay, K., & Gangopadhyay, S. (2013) · Reports on Progress in Physics · doi:10.1088/0034-4885/76/6/066501 · Cited by 166
“In the first method, the patterns produced by photolithographic means define the areas or volumes where the subsequent self-assembly processes can take place [394].”
MethodChung, S., Sudo, R., Vickerman, V., Zervantonakis, I. K., & Kamm, R. D. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-9899-3 · Cited by 154
Variation in diffusion of gases through PDMS due to plasma surface treatment and storage conditions
Markov, D. A., Lillie, E. M., Garbett, S. P., & McCawley, L. J. (2014) · Biomedical Microdevices · doi:10.1007/s10544-013-9808-2 · Cited by 144
“…electrophoresis (Effenhauser et al. 1997; Vickers et al. 2006) to cell culture (Gao et al. 2011; Leclerc et al. 2004; Saito et al. 2006; Thomas et al. 2011) and long-term organotypic cultures (Kim et al. 2007; Liu et al. 2010; Markov et al. 2012; McDonald and Whitesides 2002; Prokop et al. 2004).”
BackgroundTranslating tissue engineering technology platforms into cancer research
Hutmacher, D. W., Horch, R. E., Loessner, D., Rizzi, S., Sieh, S., Reichert, J. C., Clements, J. A., Beier, J. P., Arkudas, A., Bleiziffer, O., et al. (2009) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2009.00853.x · Cited by 135
“These matrices have been applied in a range of in vitro and in vivo studies [50, 51], and the commercially available Puramatrix, originally developed in Zhang laboratories (Boston, MA, USA), have been also used as 3D cell culture matrices in cancer research [52, 53].”
A platform for assessing chemotactic migration within a spatiotemporally defined 3D microenvironment
Abhyankar, V. V., Toepke, M. W., Cortesio, C. L., Lokuta, M. A., Huttenlocher, A., & Beebe, D. J. (2008) · Lab on a Chip · doi:10.1039/b803533d · Cited by 133
Smith, K. H., Tejeda‐Montes, E., Poch, M., & Mata, Á. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15064b · Cited by 132
Microfluidic Technology for the Generation of Cell Spheroids and Their Applications
Vadivelu, R., Kamble, H., Shiddiky, M., & Nguyen, N.-T. (2017) · Micromachines · doi:10.3390/mi8040094 · Cited by 132
“Pura matrix Hydrogel Ion reaction Increase cell attachment, proliferation and differentiation [99] Decrease the cell viability [113]”
BackgroundGoral, V. N., Hsieh, Y.-C., Petzold, O. N., Clark, J. S., Yuen, P. K., & Faris, R. A. (2010) · Lab on a Chip · doi:10.1039/c0lc00135j · Cited by 130
3D spherical microtissues and microfluidic technology for multi-tissue experiments and analysis
Kim, J.-Y., Fluri, D. A., Marchan, R., Boonen, K., Mohanty, S., Singh, P., Hammad, S., Landuyt, B., Hengstler, J. G., Kelm, J. M., et al. (2015) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2015.01.003 · Cited by 126
Microfluidics: A new cosset for neurobiology
Wang, J., Ren, L. M., Li, L., Liu, W., Zhou, J. H., Yu, W., Tong, D., & Chen, S. (2008) · Lab on a Chip · doi:10.1039/b813495b · Cited by 130
Microfluidics-assisted in vitro drug screening and carrier production
Tsui, J. H., Lee, W.-H., Pun, S. H., Kim, J., & Kim, D. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.004 · Cited by 137
“Often times a 3D culture environment is created by seeding cellswithin a hydrogel network [47–49].”
Jeong, G. S., Han, S., Shin, Y., Kwon, G. H., Kamm, R. D., Lee, S.-H., & Chung, S. (2011) · Analytical Chemistry · doi:10.1021/ac202170e · Cited by 117
Microfluidic devices for in vitro studies on liver drug metabolism and toxicity
van Midwoud, P. M., Verpoorte, E., & Groothuis, G. M. M. (2011) · Integrative Biology · doi:10.1039/c0ib00119h · Cited by 115
Development of Macroporous Poly(ethylene glycol) Hydrogel Arrays within Microfluidic Channels
Lee, A. G., Arena, C. P., Beebe, D. J., & Palecek, S. P. (2010) · Biomacromolecules · doi:10.1021/bm100792y · Cited by 125
An adaptable hydrogel array format for 3-dimensional cell culture and analysis
Jongpaiboonkit, L., King, W. J., Lyons, G. E., Paguirigan, A. L., Warrick, J. W., Beebe, D. J., & Murphy, W. L. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.040 · Cited by 128
“Previous studies in 2-D and 3-D culture work have used photolithographic techniques[31,33–35], laminar flow[36,49–52], and combinations thereof[32,53,54], to generate microarrays of photo-reactive polymers.”
BackgroundSelf-assembling Fmoc dipeptide hydrogel for in situ 3D cell culturing
Liebmann, T., Rydholm, S., Akpe, V., & Brismar, H. (2007) · BMC Biotechnology · doi:10.1186/1472-6750-7-88 · Cited by 112
Microfluidic gradient platforms for controlling cellular behavior
Chung, B. G., & Choo, J. (2010) · Electrophoresis · doi:10.1002/elps.201000137 · Cited by 111
Effects of surfactant and gentle agitation on inkjet dispensing of living cells
Parsa, S., Gupta, M., Loizeau, F., & Cheung, K. C. (2010) · Biofabrication · doi:10.1088/1758-5082/2/2/025003 · Cited by 116
“The level of albumin production is used to characterize the functional activity of liver cells, and the albumin secretion rate of Hep G2 cells cultured in a three-dimensional scaffold is higher than that of cells cultured in conventional flasks or wells [33, 34].”
BackgroundMicrofluidic Technology in Vascular Research
van der Meer, A. D., Poot, A. A., Duits, M. H. G., Feijen, J., & Vermes, I. (2009) · BioMed Research International · doi:10.1155/2009/823148 · Cited by 103
“However, using the laminar flow properties discussed earlier in this review, hydrogels can also be formed in situ and even be patterned and confined to certain regions of the microfluidic device [48].”
MethodLee, S. A., Chung, S. E., Park, W., Lee, S. H., & Kwon, S. (2009) · Lab on a Chip · doi:10.1039/b819999j · Cited by 111
Um, E., Lee, D.-S., Pyo, H., & Park, J. (2008) · Microfluidics and Nanofluidics · doi:10.1007/s10404-008-0268-6 · Cited by 98
“However, because of the low pH (*3) of the sol material, long pretreatment time of cells in the sol-state Puramatrix will decrease the cell viability ( Kim et al. 2007 ).”
BackgroundInfluentialSelf-citationThe Multi-organ Chip - A Microfluidic Platform for Long-term Multi-tissue Coculture
Materne, E.-M., Maschmeyer, I., Lorenz, A. K., Horland, R., Schimek, K. M. S., Busek, M., Sonntag, F., Lauster, R., & Marx, U. (2015) · Journal of Visualized Experiments · doi:10.3791/52526 · Cited by 95
Surface‐Treatment‐Induced Three‐Dimensional Capillary Morphogenesis in a Microfluidic Platform
Chung, S., Sudo, R., Zervantonakis, I. K., Rimchala, T., & Kamm, R. D. (2009) · Advanced Materials · doi:10.1002/adma.200901727 · Cited by 93
Yan, C., Ren, Y., Sun, X., Jin, L., Liu, X., Chen, H., Wang, K., Yu, M., & Zhao, Y. (2019) · Journal of Photochemistry and Photobiology B Biology · doi:10.1016/j.jphotobiol.2019.111680 · Cited by 91
Breast Cancer Diagnosis Using a Microfluidic Multiplexed Immunohistochemistry Platform
Kim, M. S., Kim, T., Kong, S., Kwon, S., Bae, C. Y., Choi, J., Kim, C. H., Lee, E. S., & Park, J. (2010) · PLoS ONE · doi:10.1371/journal.pone.0010441 · Cited by 90
“Since microfluidics enables the formation of a well-confined microenvironment [24,25], with fast and easy fluidic control [26] and the precise manipulation of fluids [27230], not only the variation of immunohistochemical staining, the amount of time and labor required can be reduced via automation, but also multiple b…”
Self-citationProteinaceous Hydrogels for Bioengineering Advanced 3D Tumor Models
Blanco‐Fernandez, B., Gaspar, V. M., Engel, E., & Mano, J. F. (2021) · Advanced Science · doi:10.1002/advs.202003129 · Cited by 78
Applications of Microfluidics in Stem Cell Biology
Zhang, Q., & Austin, R. H. (2012) · BioNanoScience · doi:10.1007/s12668-012-0051-8 · Cited by 88
“channel of a microfluidic device, and at the same time, the cells are 3-dimensionally immobilized and encapsulated without any additional surface treatment [68].”
BackgroundIn vitro microscale systems for systematic drug toxicity study
Sung, J. H., & Shuler, M. L. (2009) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-009-0369-y · Cited by 82
“Kim et al. reported a 3-D microfluidic platform for a cell-based assay (Fig. 2d) [44, 45 ].”
MethodTenje, M., Cantoni, F., Hernández, A. M. P., Searle, S. S., Johansson, S., Barbe, L., Antfolk, M., & Pohlit, H. (2020) · Organs-on-a-Chip · doi:10.1016/j.ooc.2020.100003 · Cited by 86
Designer Self‐Assembling Peptide Nanofiber Scaffolds for Study of 3‐D Cell Biology and Beyond
Zhang, S. (2007) · Advances in cancer research · doi:10.1016/s0065-230x(07)99005-3 · Cited by 75
Wang, Y., Feng, L., Xu, L., Li, Y., Wang, D., Hou, J., Zhou, K., Jin, Q., Ge, G., Cui, J., et al. (2016) · Chemical Communications · doi:10.1039/c6cc00119j · Cited by 69
Biosensing with Quantum Dots: A Microfluidic Approach
Vannoy, C. H., Tavares, A. J., Noor, M. O., Uddayasankar, U., & Krull, U. J. (2011) · Sensors · doi:10.3390/s111009732 · Cited by 71
“variety of cellular responses, including cell differentiation [115], chemotaxis [116], and gene expression [117].”
BackgroundDrifka, C. R., Eliceiri, K. W., Weber, S. M., & Kao, W. J. (2013) · Lab on a Chip · doi:10.1039/c3lc50487e · Cited by 64
Controlled protein adsorption on microfluidic channels with engineered roughness and wettability
Tsougeni, K., Petrou, P. S., Papageorgiou, D. P., Kakabakos, S. E., Tserepi, A. D., & Gogolides, Ε. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.10.022 · Cited by 64
Use of intrinsic clearance for prediction of human hepatic clearance
Chao, P., Uss, A. S., & Cheng, K. (2010) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1517/17425250903405622 · Cited by 62
“For years, great efforts have been made to incorporate the flow parameter to the in vitro cell culture systems for various applications [14,16,17,30-35].”
BackgroundLatex micro-balloon pumping in centrifugal microfluidic platforms
Aeinehvand, M. M., Ibrahim, F., Harun, S. W., Al-Faqheri, W., Thio, T. H. G., Kazemzadeh, A., & Madou, M. J. (2013) · Lab on a Chip · doi:10.1039/c3lc51116b · Cited by 61
The Envirostat – a new bioreactor concept
Kortmann, H., Chasanis, P., Blank, L. M., Franzke, J., Kenig, E. Y., & Schmid, A. (2008) · Lab on a Chip · doi:10.1039/b809150a · Cited by 61
Responsive Microgrooves for the Formation of Harvestable Tissue Constructs
Tekin, H., İnce, G. Ö., Tsinman, T. K., Gleason, K. K., Langer, R., Khademhosseini, A., & Demirel, M. C. (2011) · Langmuir · doi:10.1021/la200183x · Cited by 59
Choi, J., Kim, S., Jung, J.-S., Lim, Y., Kang, K., Park, S., & Kang, S. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.05.090 · Cited by 56
“Microfluidic cell culture systems have been used for 2-dimensional (2D) and 3-dimensional (3D) cell culture, as well as co-culture [8].”
BackgroundMethodChen, X., & Thibeault, S. L. (2012) · Tissue Engineering Part A · doi:10.1089/ten.tea.2012.0094 · Cited by 61
“Cell concentration was calculated such that a cell concentration of 1 · 10(6) cells/mL in 3D is equivalent to a plating density of 1 · 10(4) cells/cm(2) with respect to maintenance of constant cell-to-cell distance.(29,30) To characterize the cellular response to TGF-b1, cells were treated with various dosages of reco…”
MethodWu, Y., Ren, Y., Tao, Y., Hou, L., & Jiang, H. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03413 · Cited by 54
Ma, D., Chen, H., Shi, D., Li, Z., & Wang, J. (2009) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2008.12.046 · Cited by 54
Biomaterials-based microfluidics for engineered tissue constructs
Bettinger, C. J., & Borenstein, J. T. (2010) · Soft Matter · doi:10.1039/c0sm00247j · Cited by 55
Replication of the 3D architecture of tissues
Perez‐Castillejos, R. (2010) · Materials Today · doi:10.1016/s1369-7021(10)70015-8 · Cited by 53
Cancer immunotherapy μ-environment LabChip: taking advantage of optoelectronic tweezers
Ke, L.-Y., Kuo, Z.-K., Chen, Y.-S., Yeh, T.-Y., Dong, M., Tseng, H.-W., & Liu, C.-H. (2018) · Lab on a Chip · doi:10.1039/c7lc00963a · Cited by 50
Screening applications in drug discovery based on microfluidic technology
Eribol, P., Uğuz, A. K., & Ülgen, K. Ö. (2016) · Biomicrofluidics · doi:10.1063/1.4940886 · Cited by 53
Microfluidics for Antibiotic Susceptibility and Toxicity Testing
Dai, J. H., Hamon, M., & Jambovane, S. R. (2016) · Bioengineering · doi:10.3390/bioengineering3040025 · Cited by 50
“Different strategies have been developed to create an on-chip 3D culture system that will improve cell phenotype, including by injection of a cell-loaded hydrogel into the microfluidic chip [87] and by the formation of cell spheroids on-chip when higher cell density models are required, e.”
MethodAutomation of Three-Dimensional Cell Culture in Arrayed Microfluidic Devices
Montanez-Sauri, S. I., Sung, K. E., Puccinelli, J. P., Pehlke, C., & Beebe, D. J. (2011) · JALA: Journal of the Association for Laboratory Automation · doi:10.1016/j.jala.2011.02.003 · Cited by 49
“Moreover, microfluidic valved arrays are compatible with both 2D and 3D cell cultures to mimic in vivo-like environments.(25,26) However, 3D cell culture is more difficult as the matrix can clog the network.”
Self-Assembling Peptide Nanofibrous Hydrogel on Immediate Hemostasis and Accelerative Osteosis
Wu, M. C., Ye, Z., Zhu, H., & Zhao, X. (2015) · Biomacromolecules · doi:10.1021/acs.biomac.5b00493 · Cited by 47
Choudhury, D., Mo, X., Iliescu, C., Tan, L. L., Tong, W. H., & Yu, H. (2011) · Biomicrofluidics · doi:10.1063/1.3593407 · Cited by 45
Miniaturized pre-clinical cancer models as research and diagnostic tools
Håkanson, M., Cukierman, E., & Charnley, M. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.11.010 · Cited by 45
“within a protein 3D gel inside a microchannel had a higher viability compared to cells grown in the gel under static conditions [63].”
BackgroundA high‐discernment microflow cytometer with microweir structure
Fu, L., Tsai, C., & Lin, C. (2008) · Electrophoresis · doi:10.1002/elps.200700630 · Cited by 44
Nakatsuji, T., Shi, Y., Zhu, W., Huang, C., Chen, Y., Lee, D., Smith, J. W., Zouboulis, C. C., Gallo, R. L., & Huang, C. (2008) · PROTEOMICS · doi:10.1002/pmic.200800044 · Cited by 42
“Unlike other types of cell trappers such as PuraMatrixTM (chemical-based extracellular matrix) [30] and Gelfoam® (a gelatin derived from porcine skin) [31], DBCTS provided an nontoxic and nonimmunogenic cell scaffold because dead dermis used in DBCTS was prepared from the animal that was the same strain for implantati…”
BackgroundHsieh, C., Chen, Y.-D., Huang, S., Wang, H., & Wu, M. (2015) · BioMed Research International · doi:10.1155/2015/470283 · Cited by 46
Biomimetic Approaches to Control Soluble Concentration Gradients in Biomaterials
Nguyen, E. H., Schwartz, M. P., & Murphy, W. L. (2011) · Macromolecular Bioscience · doi:10.1002/mabi.201000448 · Cited by 47
A High-Throughput Microfluidic Platform for Mammalian Cell Transfection and Culturing
Woodruff, K., & Maerkl, S. J. (2016) · Scientific Reports · doi:10.1038/srep23937 · Cited by 45
The Neutral Self-Assembling Peptide Hydrogel SPG-178 as a Topical Hemostatic Agent
Komatsu, S., Nagai, Y., Naruse, K., & Kimata, Y. (2014) · PLoS ONE · doi:10.1371/journal.pone.0102778 · Cited by 41
The future of microfluidic assays in drug development
Wen, Y., & Yang, S. (2008) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.3.10.1237 · Cited by 48
Goetsch, K. P., Myburgh, K. H., & Niesler, C. U. (2013) · Journal of Muscle Research and Cell Motility · doi:10.1007/s10974-013-9364-7 · Cited by 48
Recent development of portable imaging platforms for cell-based assays
Yang, K., Wu, J., Santos, S. C., Liu, Y., Zhu, L., & Lin, F. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.024 · Cited by 40
Dynamics of Microvalve Operations in Integrated Microfluidics
Lau, A. T. H., Yip, H.-M., Ng, K. C. J., Cui, X., & Lam, R. H. (2014) · Micromachines · doi:10.3390/mi5010050 · Cited by 34
“Multilayer soft lithography for PDMS emerged as a ground-breaking technology for numerous biological and chemical applications, such as protein crystallization [10], blood diagnostics [11], chemical synthesis [10], bio-molecular separations [12–14], enzymatic assays [15,16], immuno-hybridization reactions [17], large-…”
BackgroundIn vivo imaging and evaluation of different biomatrices for improvement of stem cell survival
Cao, F., Rafie, A. H. S., Abilez, O. J., Wang, H., Blundo, J. T., Pruitt, B. L., Zarins, C. K., & Wu, J. C. (2007) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.55 · Cited by 37
A method for patterned in situ biofunctionalization in injection-molded microfluidic devices
Schütte, J., Freudigmann, C., Benz, K., Böttger, J., Gebhardt, R., & Stelzle, M. (2010) · Lab on a Chip · doi:10.1039/c005307d · Cited by 36
Liu, C. (2010) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0615-2 · Cited by 38
“Leclerc et al. (2003) and Kim et al. (2007) reported microfluidic cell culture chips with 3D structures, which were”
BackgroundMicrosystem with micropillar array for three- (gel-embaded) and two-dimensional cardiac cell culture
Tomecka, E., Żukowski, K., Jastrzębska, E., Chudy, M., & Brzózka, Z. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.07.186 · Cited by 36
Kulsharova, G., Kurmangaliyeva, A., Darbayeva, E., Rojas–Solórzano, L., & Toxeitova, G. (2021) · Polymers · doi:10.3390/polym13193215 · Cited by 35
Fan, R., Lan, M., Gao, X., Wang, Y., Xiang, M., Zheng, Y., Tong, A., Zhang, X., Han, B. R., Zhou, L., et al. (2017) · Advanced Science · doi:10.1002/advs.201600285 · Cited by 33
Hwang, H., Park, J., Shin, C., Do, Y., & Cho, Y. (2012) · Biomedical Microdevices · doi:10.1007/s10544-012-9733-9 · Cited by 32
“For example, Kim et al. have demonstrated 3D culture of human hepatocellular carcinoma cells in peptide hydrogel scaffold immobilized in the middle of microchannel by hydrodynamic focusing of the hydrogel (Kim et al. 2007).”
MethodSelf-citationChan, C. Y., Goral, V. N., DeRosa, M. E., Huang, T. J., & Yuen, P. K. (2014) · Biomicrofluidics · doi:10.1063/1.4894409 · Cited by 31
Microfluidic Platforms for Hepatocyte Cell Culture: New Technologies and Applications
Goral, V. N., & Yuen, P. K. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0453-8 · Cited by 38
A microfluidic device mimicking acinar concentration gradients across the liver acinus
Shih, M.-C., Tseng, S., Weng, Y., Chu, I., & Liu, C. (2013) · Biomedical Microdevices · doi:10.1007/s10544-013-9762-z · Cited by 33
Lee, D., Bae, C. Y., Kwon, S., & Park, J. (2015) · Lab on a Chip · doi:10.1039/c5lc00239g · Cited by 33
Self-citationMicrofluidic patterning of alginate hydrogels
Johann, R. M., & Renaud, P. (2007) · Biointerphases · doi:10.1116/1.2746873 · Cited by 30
Elliott, N. T., & Yuan, F. (2012) · Biotechnology and Bioengineering · doi:10.1002/bit.24397 · Cited by 29
“…involve the use of hydrogels for cell trapping, embedment, or encapsulation to provide 3D structures (Bauer et al., 2010; Chen et al., 2010; Elliott and Yuan, 2011; Kim et al., 2007; Ng and Pun, 2008; Sung et al., 2011; Toh et al., 2005, 2007; Wlodkowic and Darzynkiewicz, 2010; Wong et al., 2008).”
Colorimetric Schirmer strip for tear glucose detection
Kang, B., Park, M., & Jeong, K. (2017) · BioChip Journal · doi:10.1007/s13206-017-1405-7 · Cited by 27
Wen, Y., Zhang, X., & Yang, S. (2010) · Biotechnology Progress · doi:10.1002/btpr.423 · Cited by 28
Promises, challenges and future directions of μCCAs
Esch, M. B., Sung, J. H., & Shuler, M. L. (2010) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2010.02.020 · Cited by 30
“One of the earliest attempts was made by Leclerc et al. (2003), who cultured the hepatoma cell line HepG2 in a microfluidic device made of two stacked layers of PDMS.”
BackgroundA multilayer microdevice for cell-based high-throughput drug screening
Liu, C., Wang, L., Xu, Z., Li, J., Ding, X., Wang, Q., & Chunyu, L. (2012) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/22/6/065008 · Cited by 25
Mahto, S. K., Yoon, T. H., Shin, H., & Rhee, S. W. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9246-8 · Cited by 25
A vertical-flow bioreactor array compacts hepatocytes for enhanced polarity and functions
Zhu, L., Xia, H., Wang, Z., Fong, E. L. S., Fan, J., Tong, W. H., Seah, Y. P. D., Zhang, W., Li, Q., & Yu, H. (2016) · Lab on a Chip · doi:10.1039/c6lc00811a · Cited by 23
Sayah, A., Thivolle, P.-A., Parashar, V. K., & Gijs, M. A. M. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/8/085024 · Cited by 24
“To overcome such limitations, one of the proposed solutions is to generate 3D microfluidic structures with complex geometries [12] [13] [14] [15].”
Lobsiger, N., & Stark, W. J. (2019) · Analytical Sciences · doi:10.2116/analsci.19r004 · Cited by 24
Shen, X., Zhang, H., Li, X., Li, P., Zhao, Y., Wang, Y., & Wang, J. (2022) · Regenerative Biomaterials · doi:10.1093/rb/rbac068 · Cited by 21
“In addition, the PDMS has been widely used to make microfluidic chips for cell culture due to its good biocompatibility [47, 48].”
Method
Metadata
- Authors
- Kim, M. S., Yeon, J. H., & Park, J.-K.
- Affiliations
- Korea Advanced Institute of Science and Technology (KR)
- Corresponding author
- Park, Je-Kyun
- Venue
- Biomedical Microdevices
- Published
- 2006-11-11
- Volume
- 9
- Issue
- 1
- Pages
- 25-34
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W2074854692
- Cited by
- 166
- References
- 41
- Citations by year
- 2026: 1 · 2025: 2 · 2023: 1 · 2022: 2 · 2021: 4 · 2020: 1 · 2019: 4 · 2018: 4 · 2017: 9 · 2016: 10 · 2015: 10 · 2014: 8 · 2013: 13 · 2012: 10
- FWCI
- 9.20
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Biomedical Microdevices (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
- Keywords
- microfluidic platform, 3D cell culture, self-assembling peptide hydrogel, PuraMatrix, cell-based assays, hepatocellular carcinoma cells, HepG2 cells, albumin secretion, hydrodynamic focusing, concentration gradient, cytotoxicity assay, cell viability monitoring, dose-response assay, PDMS microfluidic device
- MeSH terms
- Animals, Biological Assay, Cell Separation, Equipment Design, Flow Cytometry, Micromanipulation, Stress, Mechanical, Flow Injection Analysis, Cell Culture Techniques, Equipment Failure Analysis, Microfluidic Analytical Techniques, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.