Generation of stable concentration gradients in 2D and 3D environments using a microfluidic ladder chamber
The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Crank, J. (1956) · CERN Document Server (European Organization for Nuclear Research) · Cited by 18,978
Diffusion, mass transfer in fluid systems
(1997) · Choice Reviews Online · doi:10.5860/choice.35-0927 · Cited by 4,930
Physical chemistry of macromolecules
(2007) · Choice Reviews Online · doi:10.5860/choice.45-2038 · Cited by 3,765
THE CHEMOTACTIC EFFECT OF MIXTURES OF ANTIBODY AND ANTIGEN ON POLYMORPHONUCLEAR LEUCOCYTES
Boyden, S. (1962) · The Journal of Experimental Medicine · doi:10.1084/jem.115.3.453 · Cited by 2,733 · cited 2×
“The Boyden chamber measures chemotaxis as the number of cells that migrate across a filter between two compartments containing soluble factors (Boyden 1962).”
BackgroundMethodSoft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607 · cited 1×
“2.1 Fabrication of Ladder Chamber Ladder Chambers were fabricated using soft lithography and rapid prototyping (Whitesides et al. 2001).”
MethodInfluentialNelson, R. D., Quie, P. G., & Simmons, R. L. (1975) · The Journal of Immunology · doi:10.4049/jimmunol.115.6.1650 · Cited by 1,170 · cited 2×
“In the under-agarose assay, cells migrate on a glass coverslip, underneath an agarose gel, with wells for cells and chemoattractants punched into the agarose (Nelson et al. 1975).”
MethodNi, W.-M. (2011) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9781611971972 · Cited by 1,064
Generation of Solution and Surface Gradients Using Microfluidic Systems
Jeon, N. L., Dertinger, S. K. W., Chiu, D. T., Choi, I. S., Stroock, A. D., & Whitesides, G. M. (2000) · Langmuir · doi:10.1021/la000600b · Cited by 963 · cited 2×
“(Dertinger et al. 2001; Jeon et al. 2000) Because the height of main channel was much higher (10– 30 times) than those of bridge channels the fluorescence signal in the bridge channels was significantly weaker than the main source channel.”
BackgroundMethodSelf-citationLi Jeon, N., Baskaran, H., Dertinger, S. K. W., Whitesides, G. M., Van De Water, L., & Toner, M. (2002) · Nature Biotechnology · doi:10.1038/nbt712 · Cited by 917 · cited 1×
“This microfluidic assay has been successfully applied to study the chemotaxis of neutrophils (Jeon et al. 2002; Lin et al. 2004a,b, 2005) and breast cancer cells (Saadi et al. 2006; Wang et al. 2004), as well as the proliferation and differentiation of human neural stem cells (Chung et al. 2005).”
MethodAbility of polymorphonuclear leukocytes to orient in gradients of chemotactic factors.
Zigmond, S. H. (1977) · The Journal of cell biology · doi:10.1083/jcb.75.2.606 · Cited by 907
Cited by
Biomolecular gradients in cell culture systems
Keenan, T. M., & Folch, A. (2008) · Lab Chip · doi:10.1039/b711887b · Cited by 596
Cell migration into scaffolds under co-culture conditions in a microfluidic platform
Chung, S., Sudo, R., Mack, P. J., Wan, C.-R., Vickerman, V., & Kamm, R. D. (2009) · Lab Chip · doi:10.1039/b807585a · Cited by 519
Microfluidic cell culture systems for drug research
Wu, M.-H., Huang, S.-B., & Lee, G.-B. (2010) · Lab on a Chip · doi:10.1039/b921695b · Cited by 432
Engineering microscale cellular niches for three-dimensional multicellular co-cultures
Huang, C. P., Lu, J., Seon, H., Lee, A. P., Flanagan, L. A., Kim, H.-Y., Putnam, A. J., & Jeon, N. L. (2009) · Lab on a Chip · doi:10.1039/b818401a · Cited by 384
Self-citationBiological applications of microfluidic gradient devices
Kim, S., Kim, H. J., & Jeon, N. L. (2010) · Integrative Biology · doi:10.1039/c0ib00055h · Cited by 366
Self-citationMicrofluidic tools for cell biological research
Velve-Casquillas, G., Le Berre, M., Piel, M., & Tran, P. T. (2010) · Nano Today · doi:10.1016/j.nantod.2009.12.001 · Cited by 359
Vickerman, V., Blundo, J., Chung, S., & Kamm, R. (2008) · Lab on a Chip · doi:10.1039/b802395f · Cited by 340
Concentration gradient generation methods based on microfluidic systems
Wang, X., Liu, Z., & Pang, Y. (2017) · RSC Advances · doi:10.1039/c7ra04494a · Cited by 219
Endothelial cell polarization and chemotaxis in a microfluidic device
Shamloo, A., Ma, N., Poo, M.-M., Sohn, L. L., & Heilshorn, S. C. (2008) · Lab on a Chip · doi:10.1039/b719788h · Cited by 209
Microfluidic devices for cell cultivation and proliferation
Tehranirokh, M., Kouzani, A. Z., Francis, P. S., & Kanwar, J. R. (2013) · Biomicrofluidics · doi:10.1063/1.4826935 · Cited by 202
Yeon, J. H., Ryu, H. R., Chung, M., Hu, Q. P., & Jeon, N. L. (2012) · Lab on a Chip · doi:10.1039/c2lc40131b · Cited by 179
Self-citationBacterial Chemotaxis in Linear and Nonlinear Steady Microfluidic Gradients
Ahmed, T., Shimizu, T. S., & Stocker, R. (2010) · Nano Letters · doi:10.1021/nl101204e · Cited by 162
Buchanan, C. F., Voigt, E. E., Szot, C. S., Freeman, J. W., Vlachos, P. P., & Rylander, M. N. (2014) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2012.0731 · Cited by 143
“17,35,36,65,78,83,84 While these systems provide dynamic 3D cell culture environments with complex planar geometries, the low cell density and scaffold thickness limitations inherent to silicon microfabricated devices severely restrict dynamic cellular processes and prevent downstream molecular…”
Simultaneous or Sequential Orthogonal Gradient Formation in a 3D Cell Culture Microfluidic Platform
Uzel, S. G. M., Amadi, O. C., Pearl, T. M., Lee, R. T., So, P. T. C., & Kamm, R. D. (2016) · Small · doi:10.1002/smll.201501905 · Cited by 100
Zou, H., Yue, W., Yu, W.-K., Liu, D., Fong, C.-C., Zhao, J., & Yang, M. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00873 · Cited by 47
Modulating chemotaxis of lung cancer cells by using electric fields in a microfluidic device
Kao, Y.-C., Hsieh, M.-H., Liu, C.-C., Pan, H.-J., Liao, W.-Y., Cheng, J.-Y., Kuo, P.-L., & Lee, C.-H. (2014) · Biomicrofluidics · doi:10.1063/1.4870401 · Cited by 19
Metadata
- Authors
- Saadi, W., Rhee, S. W., Lin, F., Vahidi, B., Chung, B. G., & Jeon, N. L.
- Venue
- Biomedical Microdevices
- Published
- 2007-05-25
- Volume
- 9
- Issue
- 5
- Pages
- 627-635
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W2091677691
- Cited by
- 194
- References
- 43
- FWCI
- 11.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.