3D microfilter device for viable circulating tumor cell (CTC) enrichment from blood
Open accessThe DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Detection of circulating tumor cells has emerged as a promising minimally invasive diagnostic and prognostic tool for patients with metastatic cancers. We report a novel three dimensional microfilter device that can enrich viable circulating tumor cells from blood. This device consists of two layers of parylene membrane with pores and gap precisely defined with photolithography. The positions of the pores are shifted between the top and bottom membranes. The bottom membrane supports captured cells and minimize the stress concentration on cell membrane and sustain cell viability during filtration. Viable cell capture on device was investigated with scanning electron microscopy, confocal microscopy, and immunofluorescent staining using model systems of cultured tumor cells spiked in blood or saline. The paper presents and validates this new 3D microfiltration concept for circulation tumor cell enrichment application. The device provides a highly valuable tool for assessing and characterizing viable enriched circulating tumor cells in both research and clinical settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hanahan, D., & Weinberg, R. A. (2000) · Cell · doi:10.1016/s0092-8674(00)81683-9 · Cited by 29,219
Stem cells, cancer, and cancer stem cells
Reya, T., Morrison, S. J., Clarke, M. F., & Weissman, I. L. (2001) · Nature · doi:10.1038/35102167 · Cited by 9,738
Circulating Tumor Cells, Disease Progression, and Survival in Metastatic Breast Cancer
Cristofanilli, M., Budd, G. T., Ellis, M. J., Stopeck, A., Matera, J., Miller, M. C., Reuben, J. M., Doyle, G. V., Allard, W. J., Terstappen, L. W. M. M., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa040766 · Cited by 4,593
Cancer Metastasis: Building a Framework
Gupta, G. P., & Massagué, J. (2006) · Cell · doi:10.1016/j.cell.2006.11.001 · Cited by 4,247
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Allard, W. J., Matera, J., Miller, M. C., Repollet, M., Connelly, M. C., Rao, C., Tibbe, A. G. J., Uhr, J. W., & Terstappen, L. W. M. M. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-0378 · Cited by 2,542
Stewart, B. W., & Kleihues, P. (2003) · Cited by 2,386
Tumor metastasis: mechanistic insights and clinical challenges
Steeg, P. S. (2006) · Nature Medicine · doi:10.1038/nm1469 · Cited by 2,134
Weinberg, R. A., & Weinberg, R. A. (2006) · W.W. Norton eBooks · doi:10.1201/9780203852569 · Cited by 1,751
Detection of Mutations in EGFR in Circulating Lung-Cancer Cells
Maheswaran, S., Sequist, L. V., Nagrath, S., Ulkus, L., Brannigan, B., Collura, C. V., Inserra, E., Diederichs, S., Iafrate, A. J., Bell, D. W., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0800668 · Cited by 1,617
Cited by
Acoustic separation of circulating tumor cells
Li, P., Mao, Z., Peng, Z., Zhou, L., Chen, Y., Huang, P.-H., Truica, C. I., Drabick, J. J., El-Deiry, W. S., Dao, M., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1504484112 · Cited by 782
Circulating Tumor Cells and Circulating Tumor DNA
Alix-Panabières, C., Schwarzenbach, H., & Pantel, K. (2012) · Annual Review of Medicine · doi:10.1146/annurev-med-062310-094219 · Cited by 485
Surface Modification of Polymers: Methods and Applications
Nemani, S. K., Annavarapu, R. K., Mohammadian, B., Raiyan, A., Heil, J., Haque, M. A., Abdelaal, A., & Sojoudi, H. (2018) · Advanced Materials Interfaces · doi:10.1002/admi.201801247 · Cited by 484
Liquid biopsy of cancer: a multimodal diagnostic tool in clinical oncology
Palmirotta, R., Lovero, D., Cafforio, P., Felici, C., Mannavola, F., Pellè, E., Quaresmini, D., Tucci, M., & Silvestris, F. (2018) · Therapeutic Advances in Medical Oncology · doi:10.1177/1758835918794630 · Cited by 423
Detecting Circulating Tumor Cells: Current Challenges and New Trends
Hong, B., & Zu, Y. (2013) · Theranostics · doi:10.7150/thno.5195 · Cited by 351
Rare cell isolation and analysis in microfluidics
Chen, Y., Li, P., Huang, P.-H., Xie, Y., Mai, J. D., Wang, L., Nguyen, N.-T., & Huang, T. J. (2014) · Lab on a Chip · doi:10.1039/c3lc90136j · Cited by 307
Microfluidic approaches for cancer cell detection, characterization, and separation
Chen, J., Li, J., & Sun, Y. (2012) · Lab on a Chip · doi:10.1039/c2lc21273k · Cited by 301
Double spiral microchannel for label-free tumor cell separation and enrichment
Sun, J., Li, M., Liu, C., Zhang, Y., Liu, D., Liu, W., Hu, G., & Jiang, X. (2012) · Lab on a Chip · doi:10.1039/c2lc40679a · Cited by 293
Lianidou, E. S., & Markou, A. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2011.165068 · Cited by 265
Emerging Role of Nanomaterials in Circulating Tumor Cell Isolation and Analysis
Yoon, H. J., Kozminsky, M., & Nagrath, S. (2014) · ACS Nano · doi:10.1021/nn5004277 · Cited by 245
“The membrane design was modified for inclusion in a 3D hexagonal patch which featured a second membrane layer to reduce the stress caused by interaction of captured cells with the pores (Figure 3e).(38)”
BackgroundMethodLee, M. G., Shin, J. H., Bae, C. Y., Choi, S., & Park, J.-K. (2013) · Analytical Chemistry · doi:10.1021/ac4006149 · Cited by 216
Jin, C., McFaul, S. M., Duffy, S. P., Deng, X., Tavassoli, P., Black, P. C., & Ma, H. (2014) · Lab Chip · doi:10.1039/c3lc50625h · Cited by 194
Antfolk, M., & Laurell, T. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.02.017 · Cited by 184
Hosokawa, M., Kenmotsu, H., Koh, Y., Yoshino, T., Yoshikawa, T., Naito, T., Takahashi, T., Murakami, H., Nakamura, Y., Tsuya, A., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0067466 · Cited by 178
Che, J., Yu, V., Dhar, M., Renier, C., Matsumoto, M., Heirich, K., Garon, E. B., Goldman, J., Rao, J., Sledge, G. W., et al. (2016) · Oncotarget · doi:10.18632/oncotarget.7220 · Cited by 177
“For example, the ISET [8-10] and ScreenCell [11, 12] devices make use of porous filters to separate larger CTCs from the smaller RBCs and WBCs, and more recent microfluidic approaches further refine the interaction between cells and microfabricated structures [13, 14], including the use of microchannel constrictions […”
MethodKhoo, B. L., Grenci, G., Lim, Y. B., Lee, S. C., Han, J., & Lim, C. T. (2018) · Nature Protocols · doi:10.1038/nprot.2017.125 · Cited by 172
Jackson, J. M., Witek, M. A., Kamande, J. W., & Soper, S. A. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00016b · Cited by 172
Probing circulating tumor cells in microfluidics
Li, P., Stratton, Z. S., Dao, M., Ritz, J., & Huang, T. J. (2013) · Lab on a Chip · doi:10.1039/c2lc90148j · Cited by 170
Enrichment and single-cell analysis of circulating tumor cells
Song, Y., Tian, T., Shi, Y., Liu, W., Zou, Y., Khajvand, T., Wang, S., Zhu, Z., & Yang, C. (2017) · Chemical Science · doi:10.1039/c6sc04671a · Cited by 167
Microfluidic technologies for circulating tumor cell isolation
Cho, H., Kim, J., Song, H., Sohn, K. Y., Jeon, M., & Han, K.-H. (2018) · The Analyst · doi:10.1039/c7an01979c · Cited by 167
Microfluidic: An innovative tool for efficient cell sorting
Autebert, J., Coudert, B., Bidard, F.-C., Pierga, J.-Y., Descroix, S., Malaquin, L., & Viovy, J.-L. (2012) · Methods · doi:10.1016/j.ymeth.2012.07.002 · Cited by 163
“CTC were captured using micropillars[65], [71] or using a membrane-based device[62], [72], [73].”
MethodAn integrated microfluidic chip for one-step isolation of circulating tumor cells
Lee, T. Y., Hyun, K.-A., Kim, S.-I., & Jung, H.-I. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.05.163 · Cited by 94
Micro/nanofluidic technologies for efficient isolation and detection of circulating tumor cells
Yue, W.-Q., Tan, Z., Li, X.-P., Liu, F.-F., & Wang, C. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.06.009 · Cited by 34
Chen, W., Huang, N.-T., Li, X., Yu, Z. T. F., Kurabayashi, K., & Fu, J. (2013) · Frontiers in Oncology · doi:10.3389/fonc.2013.00098 · Cited by 31
Metadata
- Authors
- Zheng, S., Lin, H. K., Lu, B., Williams, A., Datar, R., Cote, R. J., & Tai, Y.-C.
- Venue
- Biomedical Microdevices
- Published
- 2010-10-27
- Volume
- 13
- Issue
- 1
- Pages
- 203-213
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W1967625972
- Cited by
- 422
- References
- 47
- FWCI
- 17.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.