Coating flexible probes with an ultra fast degrading polymer to aid in tissue insertion
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
We report a fabrication process for coating neural probes with an ultrafast degrading polymer to create consistent and reproducible devices for neural tissue insertion. The rigid polymer coating acts as a probe insertion aid, but resorbs within hours post-implantation. Despite the feasibility for short term neural recordings from currently available neural prosthetic devices, most of these devices suffer from long term gliosis, which isolates the probes from adjacent neurons, increasing the recording impedance and stimulation threshold. The size and stiffness of implanted probes have been identified as critical factors that lead to this long term gliosis. Smaller, more flexible probes that match the mechanical properties of brain tissue could allow better long term integration by limiting the mechanical disruption of the surrounding tissue during and after probe insertion, while being flexible enough to deform with the tissue during brain movement. However, these small flexible probes inherently lack the mechanical strength to penetrate the brain on their own. In this work, we have developed a micromolding method for coating a non-functional miniaturized SU-8 probe with an ultrafast degrading tyrosine-derived polycarbonate (E5005(2K)). Coated, non-functionalized probes of varying dimensions were reproducibly fabricated with high yields. The polymer erosion/degradation profiles of the probes were characterized in vitro. The probes were also mechanically characterized in ex vivo brain tissue models by measuring buckling and insertion forces during probe insertion. The results demonstrate the ability to produce polymer coated probes of consistent quality for future in vivo use, for example to study the effects of different design parameters that may affect tissue response during long term chronic intra-cortical microelectrode neural recordings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×
“Brain computer interfaces (BCI) establish communication between the brain and external devices without transmission through peripheral neural pathways (Daly and Wolpaw 2008; Hochberg et al. 2006, 2012).”
BackgroundReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · cited 1×
“Brain computer interfaces (BCI) establish communication between the brain and external devices without transmission through peripheral neural pathways (Daly and Wolpaw 2008; Hochberg et al. 2006, 2012).”
BackgroundResponse of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 2×
“…body response, which alters the recording feasibility over time until the probes are finally no longer able to acquire stable and consistent signals (Edell et al. 1992; Kozai et al. 2012b; Lund et al. 2010; Polikov et al. 2005; Turner et al. 1999; Vetter et al. 2004; Wang and Thampatty 2008).”
BackgroundBrain–computer interfaces in neurological rehabilitation
Daly, J. J., & Wolpaw, J. R. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70223-0 · Cited by 1,149 · cited 1×
“Brain computer interfaces (BCI) establish communication between the brain and external devices without transmission through peripheral neural pathways (Daly and Wolpaw 2008; Hochberg et al. 2006, 2012).”
BackgroundBiran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721 · cited 2×
“…body response, which alters the recording feasibility over time until the probes are finally no longer able to acquire stable and consistent signals (Edell et al. 1992; Kozai et al. 2012b; Lund et al. 2010; Polikov et al. 2005; Turner et al. 1999; Vetter et al. 2004; Wang and Thampatty 2008).”
BackgroundChronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646 · cited 3×
“Despite the feasibility for short term neural recordings (~2–6 weeks) (Rousche and Normann 1998; Williams et al. 1999) from these different types of probes, most of the devices ultimately failed due to disruption of the electrode-cell interface by the foreign body response, which alters the…”
BackgroundAn Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544 · cited 1×
“…B. Damodaran :H. M. Kaplan : J. Kohn New Jersey Center for Biomaterials, Rutgers, the State University of New Jersey, Piscataway, NJ, USA and electrode size, shape, spacing and even allow multiple recording sites to be fabricated within each probe to increase the device efficacy (Wise et al. 1970).”
BackgroundNeural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462 · cited 2×
“However, a chronic foreign body response can then be observed, presumably aggravated by continual shear forces of the brain moving relative to the rigid probes (Seymour and Kipke 2007; Szarowski et al. 2003).”
BackgroundMechanically-compliant intracortical implants reduce the neuroinflammatory response
Nguyen, J. K., Park, D. J., Skousen, J. L., Hess-Dunning, A. E., Tyler, D. J., Rowan, S. J., Weder, C., & Capadona, J. R. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056014 · Cited by 274 · cited 1×
“A mechanically adaptive polymer nanocomposite probe has been fabricated via film casting (Harris et al. 2011; Nguyen et al. 2014).”
Method
Cited by
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
A review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205
“Polymer Young’s modulus Biocompatibility Main biomedical applications Degradation rate/Stiffto-soft rate Biochemical effect and drug integration Sterilization PLGA [126–128] (=PLA + PGA) 1.3–2 GPa [127, 129] ++ [129] Resorbable sutures, bone repair, vascular graft, drug delivery [130] Weeks to months (tunable) [127, 1…”
InfluentialLecomte, A., Castagnola, V, Descamps, E., Dahan, L., Blatché, M. C., Dinis, T. M., Leclerc, E., Egles, C., & Bergaud, C. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/12/125003 · Cited by 110
“Commercially available polyethylene glycol (PEG) [23–26], collagen [27], sugar [28–31], and poly(lactic-co-glycolic acid) (PLGA) [10] as well as synthesized tyrosine-derived terpolymer [32, 33], chitosan [34], and dried silk fibroin (SF) from Bombyx Mori silkworms [35, 36] benefit to some extent from common attributes…”
Background
Metadata
- Authors
- Lo, M.-C., Wang, S., Singh, S., Damodaran, V. B., Kaplan, H. M., Kohn, J., Shreiber, D. I., & Zahn, J. D.
- Venue
- Biomedical Microdevices
- Published
- 2015-02-15
- Volume
- 17
- Issue
- 2
- Pages
- 34-34
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W2083592839
- Cited by
- 53
- References
- 12
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coating flexible probes with an ultra fast degrading polymer to aid in tissue insertion. https://app.cochat.ai/papers/10.1007/s10544-015-9927-z
- The paper
- Lo, M.-C., Wang, S., Singh, S., Damodaran, V. B., Kaplan, H. M., Kohn, J., Shreiber, D. I., & Zahn, J. D. (2015). Coating flexible probes with an ultra fast degrading polymer to aid in tissue insertion. Biomedical Microdevices. https://doi.org/10.1007/s10544-015-9927-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.