3D printing of soft lithography mold for rapid production of polydimethylsiloxane-based microfluidic devices for cell stimulation with concentration gradients
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Three-dimensional (3D) printing is advantageous over conventional technologies for the fabrication of sophisticated structures such as 3D micro-channels for future applications in tissue engineering and drug screening. We aimed to apply this technology to cell-based assays using polydimethylsiloxane (PDMS), the most commonly used material for fabrication of micro-channels used for cell culture experiments. Useful properties of PDMS include biocompatibility, gas permeability and transparency. We developed a simple and robust protocol to generate PDMS-based devices using a soft lithography mold produced by 3D printing. 3D chemical gradients were then generated to stimulate cells confined to a micro-channel. We demonstrate that concentration gradients of growth factors, important regulators of cell/tissue functions in vivo, influence the survival and growth of human embryonic stem cells. Thus, this approach for generation of 3D concentration gradients could have strong implications for tissue engineering and drug screening.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Immune cells were shown to both enhance and inhibit malignant cells proliferation, migration, and metastasis [125-128].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [126]
In the citing paper
“By observing cell behavior in these devices, it was found that different types of cancer cells may react differently to the same chemical stimuli.”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [198]
Citations
Cites
Induction of Pluripotent Stem Cells from Adult Human Fibroblasts by Defined Factors
Takahashi, K., Tanabe, K., Ohnuki, M., Narita, M., Ichisaka, T., Tomoda, K., & Yamanaka, S. (2007) · Cell · doi:10.1016/j.cell.2007.11.019 · Cited by 20,221
Embryonic Stem Cell Lines Derived from Human Blastocysts
Thomson, J. A., Itskovitz-Eldor, J., Shapiro, S. S., Waknitz, M. A., Swiergiel, J. J., Marshall, V. S., & Jones, J. M. (1998) · Science · doi:10.1126/science.282.5391.1145 · Cited by 15,926
Induced Pluripotent Stem Cell Lines Derived from Human Somatic Cells
Yu, J., Vodyanik, M. A., Smuga-Otto, K., Antosiewicz-Bourget, J., Frane, J. L., Tian, S., Nie, J., Jonsdottir, G. A., Ruotti, V., Stewart, R., et al. (2007) · Science · doi:10.1126/science.1151526 · Cited by 10,310
Angiogenesis in cancer and other diseases
Carmeliet, P., & Jain, R. K. (2000) · Nature · doi:10.1038/35025220 · Cited by 9,070
Involvement of chemokine receptors in breast cancer metastasis
Müller, A., Homey, B., Soto, H., Ge, N., Catron, D., Buchanan, M. E., McClanahan, T., Murphy, E., Yuan, W., Wagner, S. N., et al. (2001) · Nature · doi:10.1038/35065016 · Cited by 5,340
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Generation of human induced pluripotent stem cells from dermal fibroblasts
Lowry, W. E., Richter, L., Yachechko, R., Pyle, A. D., Tchieu, J., Sridharan, R., Clark, A. T., & Plath, K. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0711983105 · Cited by 1,041
Integrated 3D-printed reactionware for chemical synthesis and analysis
Symes, M. D., Kitson, P. J., Yan, J., Richmond, C. J., Cooper, G. J. T., Bowman, R. W., Vilbrandt, T., & Cronin, L. (2012) · Nature Chemistry · doi:10.1038/nchem.1313 · Cited by 617
Biomolecular gradients in cell culture systems
Keenan, T. M., & Folch, A. (2008) · Lab Chip · doi:10.1039/b711887b · Cited by 596
Diffusion of Macromolecules in Agarose Gels: Comparison of Linear and Globular Configurations
Pluen, A., Netti, P. A., Jain, R. K., & Berk, D. A. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)76911-0 · Cited by 573
THE GREAT ESCAPE: When Cancer Cells Hijack the Genes for Chemotaxis and Motility
Condeelis, J., Singer, R. H., & Segall, J. E. (2005) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cellbio.21.122303.120306 · Cited by 391
3D printed microfluidic devices with integrated versatile and reusable electrodes
Erkal, J. L., Selimovic, A., Gross, B. C., Lockwood, S. Y., Walton, E. L., McNamara, S., Martin, R. S., & Spence, D. M. (2014) · Lab Chip · doi:10.1039/c4lc00171k · Cited by 287
An agarose-based microfluidic platform with a gradient buffer for 3D chemotaxis studies
Haessler, U., Kalinin, Y., Swartz, M. A., & Wu, M. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9299-3 · Cited by 180
Kihara, T., Ito, J., & Miyake, J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0082382 · Cited by 116
Hyperbaric Oxygen, Vasculogenic Stem Cells, and Wound Healing
Fosen, K. M., & Thom, S. R. (2014) · Antioxidants and Redox Signaling · doi:10.1089/ars.2014.5940 · Cited by 115
A Synthetic Hydrogel with Thermoreversible Gelation. I. Preparation and Rheological Properties
Yoshioka, H., Mikami, M., Mori, Y., & Tsuchida, E. (1994) · Journal of Macromolecular Science Part A · doi:10.1080/10601329409349722 · Cited by 110
An integrated microfluidic culture device for quantitative analysis of human embryonic stem cells
Kamei, K.-I., Guo, S., Yu, Z. T. F., Takahashi, H., Gschweng, E., Suh, C., Wang, X., Tang, J., McLaughlin, J., Witte, O. N., et al. (2009) · Lab Chip · doi:10.1039/b809105f · Cited by 99
Self-citationEom, D. S., Amarnath, S., Fogel, J. L., & Agarwala, S. (2011) · Development · doi:10.1242/dev.058602 · Cited by 83
Diffusion of Insulin-Like Growth Factor-I and Ribonuclease through Fibrin Gels
Nauman, J. V., Campbell, P. G., Lanni, F., & Anderson, J. L. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.102699 · Cited by 83
Micro- and nanoengineering for stem cell biology: the promise with a caution
Kshitiz, Kim, D.-H., Beebe, D. J., & Levchenko, A. (2011) · Trends in Biotechnology · doi:10.1016/j.tibtech.2011.03.006 · Cited by 81
Probing Embryonic Stem Cell Autocrine and Paracrine Signaling Using Microfluidics
Przybyla, L., & Voldman, J. (2012) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062011-143122 · Cited by 76
Probing Embryonic Stem Cell Autocrine and Paracrine Signaling Using Microfluidics
Joel Voldman, B., & Przybyla, L. (2012) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 71
Gradient generation platforms: new directions for an established microfluidic technology
Berthier, E., & Beebe, D. J. (2014) · Lab Chip · doi:10.1039/c4lc00448e · Cited by 63
Microfluidic Technologies for Temporal Perturbations of Chemotaxis
Irimia, D. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105241 · Cited by 61
A Synthetic Hydrogel with Thermoreversible Gelation. Ii. Effect of Added Salts
Yoshioka, H., Mikami, M., Mori, Y., & Tsuchida, E. (1994) · Journal of Macromolecular Science Part A · doi:10.1080/10601329409349723 · Cited by 31
Implication of Cancer Stem Cells in Cancer Drug Development and Drug Delivery
Chow, E. K. (2013) · SLAS TECHNOLOGY · doi:10.1177/2211068212454739 · Cited by 16
Lab on a chip and circulating tumor cells
Fan, Z. H., & Beebe, D. J. (2013) · Lab on a Chip · doi:10.1039/c3lc90125d · Cited by 13
Cutting-Edge Microfabricated Biomedical Tools for Human Pluripotent Stem Cell Research
Kamei, K. (2013) · SLAS TECHNOLOGY · doi:10.1177/2211068213495394 · Cited by 11
Self-citationA Synthetic Hydrogel' with Thermoreversible Gelation. Ii. Effect of Added Salts
Yoshioka, H., Mikami, M., Mori, Y., et al. (1994) · Journal of Macromolecular Science Part A · doi:10.1080/10601329408545253 · Cited by 10
(2006) · Nature Biotechnology · doi:10.1038/nbt0106-2 · Cited by 8
Evanko, D. S. (2005) · Nature Methods · doi:10.1038/nmeth0106-8b · Cited by 4
Withers, N. D. (2011) · Nature Chemistry · doi:10.1038/nchem.1238 · Cited by 2
Research works printed but not linked: 6
- E. Cukierman, K.E. Sung, X. Su, E. Berthier, C. Pehlke, A. Friedl, D.J. Beebe, PLoS One 10, e76373 (2013)
- D.S. Eom, S. Amarnath, J.L. Fogel, S. Agarwala, Development 138, 15 (2011)
- B.J. Kim, M. Wu, Ann. Biomed. Eng. 40, 6 (2012)
- D.B. Kolesky, R.L. Truby, A.S. Gladman, T.A. Busbee, K.A. Homan, J.A. Lewis, Adv. Mater. 26, 19 (2014)
- T. Ludwig, V. Bergendahl, M. Levenstein, J. Yu, M.D. Probasco, J. Thomson, Nat. Meth. 3, 8 (2006a)
- J. Yu, M.A. Vodyanik, K. Smuga-Otto, J. Antosiewicz-Bourget, J.L. Frane, S. Tian, J. Nie, G.A. Jonsdottir, V. Ruotti, R. Stewart, I.I. Slukvin, J.A. Thomson, Science 318, 5858 (2007)
Cited by
3D printed microfluidic devices: enablers and barriers
Waheed, S., Cabot, J. M., Macdonald, N. P., Lewis, T., Guijt, R. M., Paull, B., & Breadmore, M. C. (2016) · Lab on a Chip · doi:10.1039/c6lc00284f · Cited by 1,039
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
Advances in healthcare wearable devices
Iqbal, S. M. A., Mahgoub, I., Du, E., Leavitt, M. A., & Asghar, W. (2021) · npj Flexible Electronics · doi:10.1038/s41528-021-00107-x · Cited by 714
3D-printed microfluidic devices
Amin, R., Knowlton, S., Hart, A., Yenilmez, B., Ghaderinezhad, F., Katebifar, S., Messina, M., Khademhosseini, A., & Tasoglu, S. (2016) · Biofabrication · doi:10.1088/1758-5090/8/2/022001 · Cited by 349
Recent Advances in Analytical Chemistry by 3D Printing
Gross, B., Lockwood, S. Y., & Spence, D. M. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04344 · Cited by 359
Metadata
- Authors
- Kamei, K.-I., Mashimo, Y., Koyama, Y., Fockenberg, C., Nakashima, M., Nakajima, M., Li, J., & Chen, Y.
- Affiliations
- Kyoto University (JP)
- Tokyo Institute of Technology (JP)
- Centre National de la Recherche Scientifique (FR)
- Corresponding author
- Kamei, Ken-ichiro
- Chen, Yong
- Venue
- Biomedical Microdevices
- Published
- 2015-02-17
- Volume
- 17
- Issue
- 2
- Pages
- 36-36
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W2048971561
- Semantic Scholar
- 125cade83ddbd3244638523bd8ab7ca2877d4543
- Cited by
- 196
- References
- 31
- Citations by year
- 2026: 7 · 2025: 12 · 2024: 13 · 2023: 23 · 2022: 21 · 2021: 20 · 2020: 17 · 2019: 19 · 2018: 27 · 2017: 13 · 2016: 17 · 2015: 7
- FWCI
- 10.60
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Biomedical Microdevices (publishedVersion)
- PubMed (publishedVersion)
- Institutional Repositories DataBase (IRDB) (submittedVersion)
- Funders
- Japan Society for the Promotion of Science (14F04046)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Keywords
- 3D printing, polydimethylsiloxane, microfluidics, concentration gradient, growth factor gradients, human embryonic stem cells, cell stimulation, microchannels, tissue engineering, drug screening
- MeSH terms
- Animals, Dimethylpolysiloxanes, Equipment Design, Female, Fibroblasts, Humans, Mice, Inbred ICR, Pregnancy, Cell Culture Techniques, Hydrogels, Intercellular Signaling Peptides and Proteins, Embryonic Stem Cells, Lab-On-A-Chip Devices, Printing, Three-Dimensional
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.