Terahertz-Based Porosity Measurement of Pharmaceutical Tablets: a Tutorial

Open access
Bawuah, Prince, Markl, Daniel, Farrell, Daniel, Evans, Mike, Portieri, Alessia, Anderson, Andrew, Goodwin, Daniel, Lucas, Ralph, Zeitler, J. Axel · 2020 · Journal of Infrared Millimeter and Terahertz Waves

Abstract

Porosity, one of the important quality attributes of pharmaceutical tablets, directly affects the mechanical properties, the mass transport and hence tablet disintegration, dissolution and ultimately the bioavailability of an orally administered drug. The ability to accurately and quickly monitor the porosity of tablets during manufacture or during the manufacturing process will enable a greater assurance of product quality. This tutorial systematically outlines the steps involved in the terahertz-based measurement method that can be used to quantify the porosity of a tablet within seconds in a non-destructive and non-invasive manner. The terahertz-based porosity measurement can be performed using one of the three main methods, which are (i) the zero-porosity approximation (ZPA); (ii) the traditional Bruggeman effective medium approximation (TB-EMA); and (iii) the anisotropic Bruggeman effective medium approximation (AB-EMA). By using a set of batches of flat-faced and biconvex tablets as a case study, the three main methods are compared and contrasted. Overall, frequency-domain signal processing coupled with the AB-EMA method was found to be most suitable approach in terms of accuracy and robustness when predicting the porosity of tablets over a range of complexities and geometries. This tutorial aims to concisely outline all the necessary steps, precautions and unique advantages associated with the terahertz-based porosity measurement method.

Overview

CoChat Summary

## TL;DR

This tutorial explains how to use THz-TDS to measure pharmaceutical tablet porosity quickly and non-destructively, using flat-faced and biconvex ibuprofen tablets as a case study. It concludes that frequency-domain processing combined with the anisotropic Bruggeman effective medium approximation (AB-EMA) is the most accurate and robust approach.

## Key findings

  • The case study used five batches each of flat-faced and biconvex tablets containing 10% ibuprofen, with porosity ranges reported as 7–23% in the conclusions and 6–25% during compaction.
  • Frequency-domain (FD) signal processing was judged superior to time-domain (TD) processing because it is insensitive to dispersion-based errors and gives consistent effective refractive index extraction across samples.
  • Among the three porosity models compared—ZPA, TB-EMA, and AB-EMA—the paper recommends AB-EMA because it accounts for non-spherical inclusions and was described as more robust across tablet sizes and geometries.
  • For the flat-faced tablets, the three methods agreed closely; for the biconvex tablets, AB-EMA outperformed the others, with the paper reporting for biconvex tablets an RMSE of 0.0055 and slope of 1.004 for AB-EMA, versus RMSE 0.0067 and slope 1.207 for ZPA and slope 1.204 for TB-EMA.

## Methods

  • Tutorial-style case study using THz time-domain spectroscopy (THz-TDS) in transmission geometry on two tablet geometries: flat-faced and biconvex.
  • Sample set: five batches each of flat-faced and biconvex ibuprofen tablets; each batch contained 15 tablets, and nominal porosity was measured from tablet weight, dimensions, and true density.
  • Main analysis compared TD vs FD extraction of effective refractive index, then compared three porosity models (ZPA, TB-EMA, AB-EMA) using the measured effective refractive index and nominal porosity as inputs.

## Limitations

  • The paper states that TD processing is prone to errors from dispersion and absorption that broaden the terahertz pulse; FD processing is technically more cumbersome and requires expertise.
  • The text makes evident that biconvex tablets introduce additional measurement challenges, including thickness variation, beam centering, Gouy phase shift, and possible lensing effects; this is explicitly stated in the paper.
  • The text also makes evident that the tutorial’s conclusions are based on a specific ibuprofen formulation and on only two tablet geometries; generalization beyond these cases is not directly demonstrated in the provided text.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1007/s10762-019-00659-0

Cites

67 of 68 references verified0 citation errors · 1 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

8 Valid · 9 Not valid · 7 Not checked · 68 Own results and interpretations

27 more claims

Create a free account to see all 92 claims and every source verdict.

See all claims — free account
  • Not yet classified. 37
  • Probably not a substantial claim. 14
  • It may state two separate claims as one. 12

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 66 references

Cited by

See all 92

Metadata

Authors
Bawuah, P., Markl, D., Farrell, D., Evans, M., Portieri, A., Anderson, A., Goodwin, D., Lucas, R., & Zeitler, J. A.
Affiliations
  • University of Cambridge (GB)
  • Engineering and Physical Sciences Research Council (GB)
  • TeraView (United Kingdom) (GB)
  • GlaxoSmithKline (United Kingdom) (GB)
Corresponding author
Zeitler, J. Axel
Venue
Journal of Infrared Millimeter and Terahertz Waves
Published
2020-01-11
Volume
41
Issue
4
Pages
450-469
ISSN
  • 1866-6892 (ISSN-L)
  • 1866-6906
OpenAlex
W2997386037
Cited by
92
References
66
Citations by year
2026: 12 · 2025: 19 · 2024: 13 · 2023: 16 · 2022: 13 · 2021: 10 · 2020: 8
FWCI
4.04
Type
journal article
Language
en
Open access
Licence
Locations
  • Journal of Infrared Millimeter and Terahertz Waves (publishedVersion, cc-by)
  • Strathprints: The University of Strathclyde institutional repository (University of Strathclyde) (submittedVersion)
  • Apollo (University of Cambridge) (submittedVersion)
  • Apollo (University of Cambridge) (submittedVersion, cc-by)
  • Apollo
  • Apollo (cc-by)
Funders
Innovate UK (104196)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Microwave and Dielectric Measurement Techniques
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Pharmaceutical Quality and Counterfeiting
Keywords
terahertz spectroscopy, tablet porosity, tablets, Bruggeman effective medium approximation, frequency-domain signal processing, non-destructive quality control, tablet geometry, tablet disintegration

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-08, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-08 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Terahertz-Based Porosity Measurement of Pharmaceutical Tablets: a Tutorial. https://app.cochat.ai/papers/10.1007/s10762-019-00659-0
The paper
Bawuah, P., Markl, D., Farrell, D., Evans, M., Portieri, A., Anderson, A., Goodwin, D., Lucas, R., & Zeitler, J. A. (2020). Terahertz-Based Porosity Measurement of Pharmaceutical Tablets: a Tutorial. Journal of Infrared Millimeter and Terahertz Waves. https://doi.org/10.1007/s10762-019-00659-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.