Terahertz-Based Porosity Measurement of Pharmaceutical Tablets: a Tutorial
Open accessThe DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index; 8 of the 17 sources its claims cite were checked for support.
Abstract
Porosity, one of the important quality attributes of pharmaceutical tablets, directly affects the mechanical properties, the mass transport and hence tablet disintegration, dissolution and ultimately the bioavailability of an orally administered drug. The ability to accurately and quickly monitor the porosity of tablets during manufacture or during the manufacturing process will enable a greater assurance of product quality. This tutorial systematically outlines the steps involved in the terahertz-based measurement method that can be used to quantify the porosity of a tablet within seconds in a non-destructive and non-invasive manner. The terahertz-based porosity measurement can be performed using one of the three main methods, which are (i) the zero-porosity approximation (ZPA); (ii) the traditional Bruggeman effective medium approximation (TB-EMA); and (iii) the anisotropic Bruggeman effective medium approximation (AB-EMA). By using a set of batches of flat-faced and biconvex tablets as a case study, the three main methods are compared and contrasted. Overall, frequency-domain signal processing coupled with the AB-EMA method was found to be most suitable approach in terms of accuracy and robustness when predicting the porosity of tablets over a range of complexities and geometries. This tutorial aims to concisely outline all the necessary steps, precautions and unique advantages associated with the terahertz-based porosity measurement method.
Overview
CoChat Summary
## TL;DR
This tutorial explains how to use THz-TDS to measure pharmaceutical tablet porosity quickly and non-destructively, using flat-faced and biconvex ibuprofen tablets as a case study. It concludes that frequency-domain processing combined with the anisotropic Bruggeman effective medium approximation (AB-EMA) is the most accurate and robust approach.
## Key findings
- The case study used five batches each of flat-faced and biconvex tablets containing 10% ibuprofen, with porosity ranges reported as 7–23% in the conclusions and 6–25% during compaction.
- Frequency-domain (FD) signal processing was judged superior to time-domain (TD) processing because it is insensitive to dispersion-based errors and gives consistent effective refractive index extraction across samples.
- Among the three porosity models compared—ZPA, TB-EMA, and AB-EMA—the paper recommends AB-EMA because it accounts for non-spherical inclusions and was described as more robust across tablet sizes and geometries.
- For the flat-faced tablets, the three methods agreed closely; for the biconvex tablets, AB-EMA outperformed the others, with the paper reporting for biconvex tablets an RMSE of 0.0055 and slope of 1.004 for AB-EMA, versus RMSE 0.0067 and slope 1.207 for ZPA and slope 1.204 for TB-EMA.
## Methods
- Tutorial-style case study using THz time-domain spectroscopy (THz-TDS) in transmission geometry on two tablet geometries: flat-faced and biconvex.
- Sample set: five batches each of flat-faced and biconvex ibuprofen tablets; each batch contained 15 tablets, and nominal porosity was measured from tablet weight, dimensions, and true density.
- Main analysis compared TD vs FD extraction of effective refractive index, then compared three porosity models (ZPA, TB-EMA, AB-EMA) using the measured effective refractive index and nominal porosity as inputs.
## Limitations
- The paper states that TD processing is prone to errors from dispersion and absorption that broaden the terahertz pulse; FD processing is technically more cumbersome and requires expertise.
- The text makes evident that biconvex tablets introduce additional measurement challenges, including thickness variation, beam centering, Gouy phase shift, and possible lensing effects; this is explicitly stated in the paper.
- The text also makes evident that the tutorial’s conclusions are based on a specific ibuprofen formulation and on only two tablet geometries; generalization beyond these cases is not directly demonstrated in the provided text.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
8 Valid · 9 Not valid · 7 Not checked · 68 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“Porosity, a potential critical quality attribute (CQA) of tablets, is one of the most important contributors to tablet disintegration and dissolution characteristics [46].”
What the sources say
- Supportedcites [46] 46. D. Markl, A. Strobel, R. Schlossnikl, J. Bøtker, P. Bawuah, C. Ridgway, J. Rantanen, T. Rades, P. Gane, K.E. Peiponen, J.A. Zeitler, Characterisation of Pore Structures of Pharmaceutical Tablets: A Review, Int. J. Pharm. 538 (2018) 188 -214. doi:https://doi.org/10.1016/j.ijpharm.2018.01.017. source
The Introduction (page unavailable) calls total porosity a commonly used descriptor of tablets and links pore structure to dosage-form performance. The Conclusion (page unavailable) frames the properties measured by the reviewed techniques as potential critical material and quality attributes. Together, these support the qualified claim that tablet porosity may be a CQA, although the paper does not use that exact phrase for porosity. (LLM, conf=0.84)
hedged- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Porosity, a potential critical quality attribute (CQA) of tablets, is one of the most important contributors to tablet disintegration and dissolution characteristics [46].”
What the sources say
- Supportedcites [46] 46. D. Markl, A. Strobel, R. Schlossnikl, J. Bøtker, P. Bawuah, C. Ridgway, J. Rantanen, T. Rades, P. Gane, K.E. Peiponen, J.A. Zeitler, Characterisation of Pore Structures of Pharmaceutical Tablets: A Review, Int. J. Pharm. 538 (2018) 188 -214. doi:https://doi.org/10.1016/j.ijpharm.2018.01.017. source
The Introduction (page unavailable) describes tablet void space as controlling liquid transport and liquid uptake as often rate-determining for disintegration. Section 7.2 (page unavailable) says porosity/density controls disintegration behaviour in immediate-release tablets and reports a correlation with the amount of API dissolved after 15 minutes. (LLM, conf=0.88)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The work demonstrated that there is a linear correlation between the bulk refractive index and the porosity of pharmaceutical tablets, which can be exploited through the so-called zero-porosity approximation (ZPA) as a method for measuring tablet porosity.”
What the sources say
- Partly supportedcites [35] 35. M. Juuti, H. Tuononen, T. Prykäri, V . Kontturi, M. Kuosmanen, E. Alarousu, J. Ketolainen, R. Myllylä, K.E. Peiponen, Optical and terahertz measurement techniques for flat-faced pharmaceutical tablets: a case study of gloss, surface roughness and bulk properties of starch acetate tablets, Meas. Sci. Technol. 20 (2009) 015301. doi:https://doi.org/10.1088/0957-0233/20/1/015301. sourceExperimental — accuracy not yet measured
The Results (page unavailable) say that effective refractive index rises as tablet porosity falls, and the Conclusions say a THz pulse can monitor porosity. The paper does not describe the zero-porosity approximation (ZPA) or establish a linear refractive-index–porosity relationship, so those specific parts of the claim are unsupported. (LLM, conf=0.86)
boostedstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Since porosity is a volumetric property, the use of the THz-TDS method, which is conducted in the transmission configuration, has been demonstrated to accurately measure porosity of homogenous tablets compared to conventional methods like mercury porosimetry [46].”
What the sources say
- Supportedcites [46] 46. D. Markl, A. Strobel, R. Schlossnikl, J. Bøtker, P. Bawuah, C. Ridgway, J. Rantanen, T. Rades, P. Gane, K.E. Peiponen, J.A. Zeitler, Characterisation of Pore Structures of Pharmaceutical Tablets: A Review, Int. J. Pharm. 538 (2018) 188 -214. doi:https://doi.org/10.1016/j.ijpharm.2018.01.017. source
Section 7.1 says tablet porosity is typically analysed using terahertz transmission measurements. The Discussion says porosity values from THz-TDS and conventional techniques, including mercury porosimetry, are typically in good agreement for pharmaceutical tablets, while noting that the methods can differ because mercury porosimetry accesses only open pores. (LLM, conf=0.88)
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The selected frequency range, as shown by the rectangular shaded portion in Fig. 3, was observed to be a dispersion free region for all the batches.”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
27 more claims
Create a free account to see all 92 claims and every source verdict.
- Not yet classified. 37
- Probably not a substantial claim. 14
- It may state two separate claims as one. 12
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“Based on the excellent results of both flat-faced and biconvex tablets in conjunction with the relatively long Rayleigh range of the used terahertz beam as we have extensively discussed in 34 , we can infer that curvature, lensing effect and thickness of the tablets have negligible impact on the measured porosity.”
From A Fast and Non-destructive Terahertz Dissolution Assay for Immediate Release Tablets (2021) · cites this paper as [34]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe cited source doesn’t support the claim as written.
In the citing paper
“Examples of common EMTs include Maxwell-Garnett, which typically assumes spherical inclusions and works well for low-to-moderate inclusion concentrations, and Bruggeman, which is often preferred for higher concentrations or more symmetric mixtures [49, 55, 64, 65].”
From Tutorial: Accurate Determination of Refractive Index and Absorption Coefficient in Terahertz Time-Domain Spectroscopy (2025) · cites this paper as [55]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“However, it should be noted that other published reports using differing sample preparation methods will almost certainly produce varying results, largely because of varying porosity [22].”
From Unveiling the Origin of Spurious Features in THz-TDS of Powder Compacts (2025) · cites this paper as [22]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Sample porosity must be minimised as it affects the accuracy of the RI obtained from terahertz measurements [1,9,10,14,20,21].”
From Polymer Pellet Fabrication for Accurate THz-TDS Measurements (2022) · cites this paper as [21]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Examples of common EMTs include Maxwell-Garnett, which typically assumes spherical inclusions and works well for low-to-moderate inclusion concentrations, and Bruggeman, which is often preferred for higher concentrations or more symmetric mixtures [49, 55, 64, 65].”
From Tutorial: Accurate Determination of Refractive Index and Absorption Coefficient in Terahertz Time-Domain Spectroscopy (2025) · cites this paper as [55]
Experimental — accuracy not yet measured
Citations
Cites
Bruggeman, D. A. G. (1935) · Annalen der Physik · doi:10.1002/andp.19354160705 · Cited by 8,645
Terahertz spectroscopy and imaging - Modern techniques and applications
Jepsen, P. U., Cooke, D. G., & Koch, M. (2011) · Laser & Photonics Reviews · doi:10.1002/lpor.201000011 · Cited by 2,091
THz imaging and sensing for security applications—explosives, weapons and drugs
Federici, J. F., Schulkin, B., Huang, F., Gary, D., Barat, R., Oliveira, F., & Zimdars, D. (2005) · Semiconductor Science and Technology · doi:10.1088/0268-1242/20/7/018 · Cited by 1,756
VII. Colours in metal glasses, in metallic films, and in metallic solutions.—II
Garnett, J. C. M. (1906) · Philosophical Transactions of the Royal Society of London. Series A, Containing Papers of a Mathematical or Physical Character · doi:10.1098/rsta.1906.0007 · Cited by 1,246 · cited 3×
“The general form of the Br-EMA follows naturally from the Maxwell Garnett’s EMA [61] as”
BackgroundInfluentialTerahertz time-domain spectroscopy of water vapor
van Exter, M., Fattinger, C., & Grischkowsky, D. (1989) · Optics Letters · doi:10.1364/ol.14.001128 · Cited by 862
Material parameter estimation with terahertz time-domain spectroscopy
Dorney, T. D., Baraniuk, R. G., & Mittleman, D. M. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.001562 · Cited by 807
Far-infrared vibrational modes of DNA components studied by terahertz time-domain spectroscopy
Fischer, B. M., Walther, M., & Jepsen, P. U. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/21/319 · Cited by 588
Using Terahertz Pulsed Spectroscopy to Quantify Pharmaceutical Polymorphism and Crystallinity
Strachan, C. J., Taday, P. F., Newnham, D. A., Gordon, K. C., Zeitler, J. A., Pepper, M., & Rades, T. (2005) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20281 · Cited by 378
Self-citationNoncovalent intermolecular forces in polycrystalline and amorphous saccharides in the far infrared
Walther, M., Fischer, B. M., & Uhd Jepsen, P. (2003) · Chemical Physics · doi:10.1016/s0301-0104(03)00031-4 · Cited by 369
Walther, M., Fischer, B., Schall, M., Helm, H., & Jepsen, P. U. (2000) · Chemical Physics Letters · doi:10.1016/s0009-2614(00)01271-9 · Cited by 320
Taday, P. F., Bradley, I. V., Arnone, D. D., & Pepper, M. (2003) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.10358 · Cited by 318
Nondestructive analysis of tablet coating thicknesses using terahertz pulsed imaging
Fitzgerald, A. J., Cole, B. E., & Taday, P. F. (2005) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20225 · Cited by 289
Fundamentals of Measurement in Terahertz Time-Domain Spectroscopy
Withayachumnankul, W., & Naftaly, M. (2014) · Journal of Infrared, Millimeter, and Terahertz Waves · doi:10.1007/s10762-013-0042-z · Cited by 288
Using terahertz pulsed spectroscopy to study crystallinity of pharmaceutical materials
Strachan, C. J., Rades, T., Newnham, D. A., Gordon, K. C., Pepper, M., & Taday, P. F. (2004) · Chemical Physics Letters · doi:10.1016/j.cplett.2004.03.117 · Cited by 230
Zeitler, J. A., Shen, Y., Baker, C., Taday, P. F., Pepper, M., & Rades, T. (2007) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20789 · Cited by 208 · cited 1×
“industrial implementations, for example, in automotive [4], paper [5] and pharmaceutical [6, 7] Journal of Infrared, Millimeter, and Terahertz Waves https://doi.”
BackgroundSelf-citationSinka, I. C., Cunningham, J. C., & Zavaliangos, A. (2003) · Powder Technology · doi:10.1016/s0032-5910(03)00094-9 · Cited by 201 · cited 1×
“compaction yields biconvex tablets with high density distribution along the centre [62], which may partly explain the higher neff values obtained for the biconvex tablets compared with the flat-faced tablets (Fig.”
ResultTemperature-dependent low-frequency vibrational spectra of purine and adenine
Shen, Y. C., Upadhya, P. C., Linfield, E. H., & Davies, A. G. (2003) · Applied Physics Letters · doi:10.1063/1.1565680 · Cited by 182
Shen, Y.-C., & Taday, P. F. (2008) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2007.911309 · Cited by 181
Next generation 15 µm terahertz antennas: mesa-structuring of InGaAs/InAlAs photoconductive layers
Roehle, H., Dietz, R. J. B., Hensel, H. J., Böttcher, J., Künzel, H., Stanze, D., Schell, M., & Sartorius, B. (2010) · Optics Express · doi:10.1364/oe.18.002296 · Cited by 181
In-vitro tomography and non-destructive imaging at depth of pharmaceutical solid dosage forms
ZEITLER, J., & GLADDEN, L. (2009) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2008.08.012 · Cited by 177
Self-citationDie theorie des Mischkörpers für das Feld der stationären Strömung
Wiener, O. (1912) · Cited by 169
May, R. K., Evans, M. J., Zhong, S., Warr, I., Gladden, L. F., Shen, Y., & Zeitler, J. A. (2011) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22359 · Cited by 160
Self-citationZeitler, J. A., Newnham, D. A., Taday, P. F., Threlfall, T. L., Lancaster, R. W., Berg, R. W., Strachan, C. J., Pepper, M., Gordon, K. C., & Rades, T. (2006) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20719 · Cited by 157
Self-citationCharacterisation of pore structures of pharmaceutical tablets: A review
Markl, D., Strobel, A., Schlossnikl, R., Bøtker, J., Bawuah, P., Ridgway, C., Rantanen, J., Rades, T., Gane, P., Peiponen, K.-E., et al. (2018) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2018.01.017 · Cited by 154
Self-citationA COMPACT MONOPOLE MIMO ARRAY FOR THE 5–6-GHz BAND
Mathew, K. T., Anil, L., Paul, B., et al. (2007) · Hispana · doi:10.1002/mop · Cited by 148
Phase Retrieval in Terahertz Time-Domain Measurements: a 'how to' Tutorial
Jepsen, P. U. (2019) · Journal of Infrared, Millimeter and Terahertz Waves · doi:10.1007/s10762-019-00578-0 · Cited by 114 · cited 1×
“The frequency-dependent effective refractive index of the tablet is then accurately extracted from the phase information by, firstly, unwrapping and correcting the phase and, secondly, determining the phase difference between the reference and the sample signals similar to the routine extensively discussed by Jepsen […”
MethodParrott, E. P. J., Zeitler, J. A., Friščić, T., Pepper, M., Jones, W., Day, G. M., & Gladden, L. F. (2009) · Crystal Growth & Design · doi:10.1021/cg8008893 · Cited by 111
Self-citationKužel, P., Němec, H., Kadlec, F., & Kadlec, C. (2010) · Optics Express · doi:10.1364/oe.18.015338 · Cited by 111
Analytical Techniques in the Pharmaceutical Sciences
Rades, T., Perrie, Y., & Müllertz, A. (2016) · Advances in delivery science and technology · doi:10.1007/978-1-4939-4029-5 · Cited by 107
Suzuki, M., & Tonouchi, M. (2005) · Applied Physics Letters · doi:10.1063/1.1901817 · Cited by 106
Ho, L., Müller, R., Gordon, K. C., Kleinebudde, P., Pepper, M., Rades, T., Shen, Y., Taday, P. F., & Zeitler, J. A. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.01.002 · Cited by 98
Self-citationHardness and Density Distributions of Pharmaceutical Tablets Measured by Terahertz Pulsed Imaging
May, R. K., Su, K., Han, L., Shuncong Zhong, A., Elliott, J. A., Gladden, L. F., Evans, M. J., Shen, Y., & Zeitler, J. A. (2013) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23560 · Cited by 86
Self-citationDelayed Release Tablet Dissolution Related to Coating Thickness by Terahertz Pulsed Image Mapping
Spencer, J. A., Gao, Z., Moore, T. W., Buhse, L. F., Taday, P. F., Newnham, D. A., Shen, Y., Portieri, A., & Husain, A. (2007) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21051 · Cited by 84
Self-citationCrystallization and Phase Changes in Paracetamol from the Amorphous Solid to the Liquid Phase
Šibík, J., Sargent, M. J., Franklin, M., & Zeitler, J. A. (2014) · Molecular Pharmaceutics · doi:10.1021/mp400768m · Cited by 83
Self-citationData Extraction from Terahertz Time Domain Spectroscopy Measurements
Scheller, M. (2014) · Journal of Infrared Millimeter and Terahertz Waves · doi:10.1007/s10762-014-0053-4 · Cited by 81
Li, R., Zeitler, J. A., Tomerini, D., Parrott, E. P. J., Gladden, L. F., & Day, G. M. (2010) · Physical Chemistry Chemical Physics · doi:10.1039/b926536h · Cited by 79
Self-citationMarkl, D., Wang, P., Ridgway, C., Karttunen, A.-P., Chakraborty, M., Bawuah, P., Pääkkönen, P., Gane, P., Ketolainen, J., Peiponen, K.-E., et al. (2017) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2017.02.028 · Cited by 77
Self-citationPr 0.5 Sr 0.5 CoO 3 の温度変化と電子線照射により引起された磁区構造の変化
Uchida, M., Mahendiran, R., Tomioka, Y., et al. (2005) · Applied Physics Letters · Cited by 75
Bawuah, P., Pierotic Mendia, A., Silfsten, P., Pääkkönen, P., Ervasti, T., Ketolainen, J., Zeitler, J. A., & Peiponen, K.-E. (2014) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2014.02.011 · Cited by 70 · cited 2×
“[40] successfully demonstrated that THz-TDS in conjunction with the Bruggeman effective medium approximation can be used to nondestructively and non-invasively measure the porosity of pharmaceutical tablets.”
MethodSelf-citationTerahertz Pulse Spectroscopy of Biological Materials: L-Glutamic Acid
Taday, P. F., Bradley, I. V., & Arnone, D. D. (2003) · Journal of Biological Physics · doi:10.1023/a:1024424205309 · Cited by 65
Relaxation and Crystallization of Amorphous Carbamazepine Studied by Terahertz Pulsed Spectroscopy
Zeitler, J. A., Taday, P. F., Pepper, M., & Rades, T. (2007) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20908 · Cited by 63
Self-citationChemical mapping using reflection terahertz pulsed imaging
Shen, Y. C., Taday, P. F., Newnham, D. A., & Pepper, M. (2005) · Semiconductor Science and Technology · doi:10.1088/0268-1242/20/7/016 · Cited by 61
Solid‐State Transition Mechanism in Carbamazepine Polymorphs by Time‐Resolved Terahertz Spectroscopy
Zeitler, J. A., Taday, P. F., Gordon, K. C., Pepper, M., & Rades, T. (2007) · ChemPhysChem · doi:10.1002/cphc.200700261 · Cited by 55
Self-citationJuuti, M., Tuononen, H., Prykäri, T., Kontturi, V, Kuosmanen, M., Alarousu, E., Ketolainen, J., Myllylä, R., & Peiponen, K.-E. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/1/015301 · Cited by 55
Ho, L., Müller, R., Gordon, K. C., Kleinebudde, P., Pepper, M., Rades, T., Shen, Y., Taday, P. F., & Zeitler, J. A. (2009) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21766 · Cited by 51
Self-citationParrott, E. P., Zeitler, J. A., & Gladden, L. F. (2009) · Optics Letters · doi:10.1364/ol.34.003722 · Cited by 47
Self-citationBawuah, P., Tan, N., Tweneboah, S. N. A., Ervasti, T., Axel Zeitler, J., Ketolainen, J., & Peiponen, K.-E. (2016) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2016.06.007 · Cited by 42 · cited 7×
“[44] showed that the assumption of the spherical inclusion in the Bruggeman effective medium approximation (from now onwards known as the traditional Bruggeman effective medium approximation, TB-EMA) can limit the accurate prediction of the effective refractive index when tablets containing API and those composed of a…”
BackgroundSelf-citationFast and non-destructive pore structure analysis using terahertz time-domain spectroscopy
Markl, D., Bawuah, P., Ridgway, C., van den Ban, S., Goodwin, D. J., Ketolainen, J., Gane, P., Peiponen, K.-E., & Zeitler, J. A. (2018) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.12.029 · Cited by 42
Self-citationPalermo, R. N., Cogdill, R. P., Short, S. M., Drennen, J. K., & Taday, P. F. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.10.023 · Cited by 40
Pharmaceutical Terahertz Spectroscopy and Imaging
Zeitler, J. A. (2016) · Advances in delivery science and technology · doi:10.1007/978-1-4939-4029-5_5 · Cited by 40
Self-citationBawuah, P., Silfsten, P., Ervasti, T., Ketolainen, J., Zeitler, J. A., & Peiponen∥, K.-E. (2014) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2014.09.027 · Cited by 38
Self-citationProbing Phase Transitions in Simvastatin with Terahertz Time-Domain Spectroscopy
Tan, N. Y., & Zeitler, J. A. (2015) · Molecular Pharmaceutics · doi:10.1021/mp500649q · Cited by 36
Self-citationNoninvasive porosity measurement of biconvex tablets using terahertz pulses
Bawuah, P., Ervasti, T., Tan, N., Zeitler, J. A., Ketolainen, J., & Peiponen, K.-E. (2016) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2016.06.023 · Cited by 29 · cited 1×
“an active pharmaceutical ingredient, API) [41] and shapes [42, 43].”
BackgroundSelf-citationTuononen, H., Fukunaga, K., Kuosmanen, M., Ketolainen, J., & Peiponen, K.-E. (2010) · Applied Spectroscopy · doi:10.1366/000370210792966170 · Cited by 25
Characterization of Poly-Amorphous Indomethacin by Terahertz Spectroscopy
Otsuka, M., Nishizawa, J., Fukura, N., & Sasaki, T. (2012) · Journal of Infrared Millimeter and Terahertz Waves · doi:10.1007/s10762-012-9910-1 · Cited by 25
Ridgway, C., Bawuah, P., Markl, D., Zeitler, J. A., Ketolainen, J., Peiponen, K.-E., & Gane, P. (2017) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.04.038 · Cited by 22
Self-citationKawase, M., Yamamoto, K., Takagi, K., Yasuda, R., Ogawa, M., Hatsuda, Y., Kawanishi, S., Hirotani, Y., Myotoku, M., Urashima, Y., et al. (2013) · Journal of Infrared, Millimeter, and Terahertz Waves · doi:10.1007/s10762-013-9994-2 · Cited by 17
Experimental Gouy phase shift compensation in Terahertz time-domain spectroscopy
Koleják, P., Postava, K., Mičica, M., Kužel, P., Kadlec, F., & Pištora, J. (2018) · Photonics and Nanostructures - Fundamentals and Applications · doi:10.1016/j.photonics.2018.06.011 · Cited by 17
Handheld terahertz spectrometer for the detection of liquid explosives
Krumbholz, N., Jansen, C., Scheller, M., Müller-Wirts, T., Lübbecke, S., Holzwarth, R., Scheunemann, R., Wilk, R., Sartorius, B., Roehle, H., et al. (2009) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.830381 · Cited by 16
Calibration independent estimation of optical constants using terahertz time‐domain spectroscopy
Singh, S. P., Akhter, Z., & Akhtar, M. J. (2015) · Microwave and Optical Technology Letters · doi:10.1002/mop.29207 · Cited by 13
Optical Constants of Harmful and Highly Energetic Liquids for Application to THz Screening Systems
Beckmann, J., Marchetti, B., von Chrzanowski, L. S., Ritter, E., Puškar, L., Aziz, E. F., & Schade, U. (2016) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2016.2547319 · Cited by 12
Dong, Y., Zhang, J., Shen, Y., Su, K., & Zeitler, J. A. (2015) · International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz) · doi:10.1109/irmmw-thz.2015.7327452 · Cited by 12
Self-citationTerahertz absorption spectra of commonly used antimalarial drugs
Bawuah, P., Zeitler, J. A., Ketolainen, J., & Peiponen, K.-E. (2018) · Optical Review · doi:10.1007/s10043-018-0423-6 · Cited by 9
Self-citationPaper Parameter Estimation Using Terahertz Time-Domain Spectroscopy
Dodge, J. S., Mousavi, P., Bushfield, I., Savard, S., Jez, D., & Haran, F. (2014) · 2014 International Symposium on Optomechatronic Technologies · doi:10.1109/isot.2014.36 · Cited by 3
Hirose, M., Toyota, S., & Tsumura, N. (2017) · Optical Review · doi:10.1007/s10043-017-0368-1 · Cited by 3
Using terahertz time-domain spectroscopy to identify pharmaceutical cocrystals
Parrott, E. P. J., Nguyen, K. L., Friščić, T., et al. (2007) · doi:10.1109/icimw.2007.4516670 · Cited by 2
Self-citationPaper Parameter Estimation Using Time-domain Terahertz Spectroscopy
Dodge, J. S., Mousavi, P., Bushfield, I., Savard, S., Jez, D., & Haran, F. M. (2014) · Imaging and Applied Optics · doi:10.1364/aio.2014.aw1a.1 · Cited by 2
Barbero (2014) · doi:10.1016/j · Cited by 1
Cited by
Nsengiyumva, W., Zhong, S., Zheng, L., Liang, W., Wang, B., Huang, Y., Chen, X., & Shen, Y. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3318676 · Cited by 154
Advances in terahertz time-domain spectroscopy of pharmaceutical solids: A review
Bawuah, P., & Zeitler, J. A. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116272 · Cited by 128
Self-citationBanks, P. A., Kleist, E. M., & Ruggiero, M. T. (2023) · Nature Reviews Chemistry · doi:10.1038/s41570-023-00487-w · Cited by 130
Advancing non-destructive analysis of 3D printed medicines
Jørgensen, A. K., Ong, J. J., Parhizkar, M., Goyanes, Á., & Basit, A. W. (2023) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2023.03.006 · Cited by 59
A Fast and Non-destructive Terahertz Dissolution Assay for Immediate Release Tablets
Bawuah, P., Markl, D., Turner, A., Evans, M., Portieri, A., Farrell, D., Lucas, R., Anderson, A., Goodwin, D. J., & Zeitler, J. A. (2021) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2020.11.041 · Cited by 45
Self-citation
Metadata
- Authors
- Bawuah, P., Markl, D., Farrell, D., Evans, M., Portieri, A., Anderson, A., Goodwin, D., Lucas, R., & Zeitler, J. A.
- Affiliations
- University of Cambridge (GB)
- Engineering and Physical Sciences Research Council (GB)
- TeraView (United Kingdom) (GB)
- GlaxoSmithKline (United Kingdom) (GB)
- Corresponding author
- Zeitler, J. Axel
- Venue
- Journal of Infrared Millimeter and Terahertz Waves
- Published
- 2020-01-11
- Volume
- 41
- Issue
- 4
- Pages
- 450-469
- ISSN
- 1866-6892 (ISSN-L)
- 1866-6906
- OpenAlex
- W2997386037
- Cited by
- 92
- References
- 66
- Citations by year
- 2026: 12 · 2025: 19 · 2024: 13 · 2023: 16 · 2022: 13 · 2021: 10 · 2020: 8
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Journal of Infrared Millimeter and Terahertz Waves (publishedVersion, cc-by)
- Strathprints: The University of Strathclyde institutional repository (University of Strathclyde) (submittedVersion)
- Apollo (University of Cambridge) (submittedVersion)
- Apollo (University of Cambridge) (submittedVersion, cc-by)
- Apollo
- Apollo (cc-by)
- Funders
- Innovate UK (104196)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Microwave and Dielectric Measurement Techniques
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Pharmaceutical Quality and Counterfeiting
- Keywords
- terahertz spectroscopy, tablet porosity, tablets, Bruggeman effective medium approximation, frequency-domain signal processing, non-destructive quality control, tablet geometry, tablet disintegration
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-08, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-08 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.





