Cited by 49Non-Invasive Vital Sign MonitoringCardiovascular Health and Disease PreventionHeart Rate Variability and Autonomic Control

Investigation of peripheral photoplethysmographic morphology changes induced during a hand-elevation study

Hickey, Michelle, Phillips, Justin P., Kyriacou, Panayiotis A.·2016·Journal of Clinical Monitoring and Computing

Abstract

A hand-elevation study was carried out in the laboratory in order to alter peripheral blood flow with the aim of increasing understanding of factors affecting the morphology of peripheral photoplethysmographic signals. Photoplethysmographic (PPG) signals were recorded from twenty healthy volunteer subjects during a hand-elevation study in which the right hand was raised and lowered relative to heart level, while the left hand remained static. Red and infrared (IR) PPG signals were obtained from the right and left index fingers using a custom-made PPG processing system. PPG features were identified using a feature-detection algorithm based on the first derivative of the PPG signal. The systolic PPG amplitude, the reflection index, crest time, pulse width at half height, and delta T were calculated from 20 s IR PPG signals from three positions of the right hand with respect to heart level (-50, 0, +50 cm) in 19 volunteers. PPG features were found to change with hand elevation. On lowering the hand to 50 cm below heart level, ac systolic PPG amplitudes from the finger decreased by 68.32 %, while raising the arm increased the systolic amplitude by 69.99 %. These changes in amplitude were attributed to changes in hydrostatic pressure and the veno-arterial reflex. Other morphological variables, such as crest time, were found to be statistically significantly different across hand positions, indicating increased vascular resistance on arm elevation than on dependency. It was hypothesized that these morphological PPG changes were influenced by changes in downstream venous resistance, rather than arterial, or arteriolar, resistance. Changes in hand position relative to heart level can significantly affect the morphology of the peripheral ac PPG waveform. These alterations are due to a combination of physical effects and physiological responses to changes in hand position, which alter vascular resistance. Care should be taken when interpreting morphological data derived from PPG signals and methods should be standardized to take these effects into account.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s10877-015-9761-0

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The PPG can be affected by changes in the height of measurement relative to the heart.

    “Finally, the PPG can be affected by changes in the height of measurement relative to the heart [53].”

    From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [53]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 39 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Hickey, M., Phillips, J. P., & Kyriacou, P. A.
Affiliations
City, University of London (GB)
Corresponding author
Hickey, Michelle
Venue
Journal of Clinical Monitoring and Computing
Published
2015-08-29
Volume
30
Issue
5
Pages
727-736
ISSN
  • 1387-1307 (ISSN-L)
  • 1573-2614
OpenAlex
W1862208204
Cited by
49
References
39
Citations by year
2026: 3 · 2025: 2 · 2024: 7 · 2023: 5 · 2022: 8 · 2021: 3 · 2020: 7 · 2019: 3 · 2018: 8 · 2017: 2 · 2016: 1
FWCI
1.82
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Clinical Monitoring and Computing (publishedVersion)
  • PubMed (publishedVersion)
  • City Research Online (City University London) (acceptedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
photoplethysmography, peripheral blood flow, hydrostatic pressure, vascular resistance, venous resistance, finger PPG
MeSH terms
Adult, Algorithms, Arteries, Blood Pressure, Female, Hand, Heart Rate, Humans, Hydrostatic Pressure, Male, Systole, Vascular Resistance, Veins, Photoplethysmography, Young Adult, Healthy Volunteers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review