Cited by 126Non-Invasive Vital Sign MonitoringCardiovascular Health and Disease PreventionHeart Rate Variability and Autonomic Control

The analysis of PPG morphology: Investigating the effects of aging on arterial compliance

Open access
Yousef, Q., Reaz, M. B. I., Ali, M. A. M.·2012·Measurement Science Review

Abstract

This study presents the variations of photoplethysmogram (PPG) morphology with age. PPG measurement is done noninvasively at the index finger on both right and left hands for a sample of erectile dysfunction (ED) subjects. Some parameters are derived from the analysis of PPG contour showed in association with age. The age is found to be an important factor that affects the contour of PPG signals which accelerates the disappearance of PPG’s dicrotic notch and PPG’s inflection point as well. Arterial compliance is found to be degraded with age due to the fall of arterial elasticity. This study approaches the establishment of usefulness of PPG’s contour analysis as an investigator to the changes in the elastic properties of the vascular system, and as a detector of early sub-clinical atherosclerosis.

Integrity signals

Registry

Crossref · 10.2478/v10048-012-0036-3

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Yousef et al. found that there is no significant increase in pulse magnitude measured at the index finger with an increase in age.

    “In a study with participants ranging in age from 30 to 60+, Yousef et al. found that there is no significant increase in pulse magnitude measured at the index finger with an increase in age.”
  • This work suggests that the decrease in vessel compliance will contribute more to variations in a PPG waveform than other effects of aging.

    “This work suggests that the decrease in vessel compliance will contribute more to variations in a PPG waveform than other effects of aging [88].”

Cites

Flagged first, then by citations

1 of the 21 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Yousef, Q., Reaz, M. B. I., & Ali, M. A. M.
Affiliations
  • Taibah University (SA)
  • National University of Malaysia (MY)
Venue
Measurement Science Review
Published
2012-01-01
Volume
12
Issue
6
ISSN
1335-8871 (ISSN-L)
OpenAlex
W2014822627
Cited by
126
References
21
Citations by year
2026: 4 · 2025: 11 · 2024: 11 · 2023: 20 · 2022: 23 · 2021: 17 · 2020: 8 · 2019: 9 · 2018: 9 · 2017: 5 · 2016: 3 · 2015: 6
FWCI
1.09
Type
journal article
Language
en
Open access
Licence
cc-by-nc-nd
Locations
Measurement Science Review (publishedVersion, cc-by-nc-nd)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
photoplethysmogram, aging, arterial compliance, arterial elasticity, dicrotic notch, inflection point, erectile dysfunction, subclinical atherosclerosis, vascular elasticity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review