The analysis of PPG morphology: Investigating the effects of aging on arterial compliance
Open accessAbstract
This study presents the variations of photoplethysmogram (PPG) morphology with age. PPG measurement is done noninvasively at the index finger on both right and left hands for a sample of erectile dysfunction (ED) subjects. Some parameters are derived from the analysis of PPG contour showed in association with age. The age is found to be an important factor that affects the contour of PPG signals which accelerates the disappearance of PPG’s dicrotic notch and PPG’s inflection point as well. Arterial compliance is found to be degraded with age due to the fall of arterial elasticity. This study approaches the establishment of usefulness of PPG’s contour analysis as an investigator to the changes in the elastic properties of the vascular system, and as a detector of early sub-clinical atherosclerosis.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Yousef et al. found that there is no significant increase in pulse magnitude measured at the index finger with an increase in age.
“In a study with participants ranging in age from 30 to 60+, Yousef et al. found that there is no significant increase in pulse magnitude measured at the index finger with an increase in age.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [88]
This work suggests that the decrease in vessel compliance will contribute more to variations in a PPG waveform than other effects of aging.
“This work suggests that the decrease in vessel compliance will contribute more to variations in a PPG waveform than other effects of aging [88].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [88]
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · see citing works
Is Pulse Pressure Useful in Predicting Risk for Coronary Heart Disease?
Franklin, S. S., Khan, S. A., Wong, N. D., Larson, M. G., & Levy, D. A. (1999) · Circulation · doi:10.1161/01.cir.100.4.354 · Cited by 1,756 · see citing works
Determination of age-related increases in large artery stiffness by digital pulse contour analysis
Millasseau, S., Kelly, R. P., Ritter, J., & Chowienczyk, P. (2002) · Clinical Science · doi:10.1042/cs1030371 · Cited by 624 · see citing works
Arterial Stiffness: A New Cardiovascular Risk Factor?
Arnett, D. K., Evans, G. W., & Riley, W. A. (1994) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a117315 · Cited by 486 · see citing works
Utility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A. T., Shaltis, P., McCombie, D. B., Asada, H. H., Warner, D. S., & Warner, M. A. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 365 · see citing works
Klocke, R., Cockcroft, J. R., Taylor, G. J., Hall, I. R., & Blake, D. R. (2003) · Annals of the Rheumatic Diseases · doi:10.1136/ard.62.5.414 · Cited by 190 · see citing works
Validation of a device to measure arterial pulse wave velocity by a photoplethysmographic method
Loukogeorgakis, S., Dawson, R., Phillips, N., Martyn, C. N., & Greenwald, S. E. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/3/309 · Cited by 164 · see citing works
Detection and Processing Techniques of FECG Signal for Fetal Monitoring
Hasan, M. A., Reaz, M. B. I., Ibrahimy, M. I., Hussain, M. S., & Uddin, J. (2009) · Biological Procedures Online · doi:10.1007/s12575-009-9006-z · Cited by 150 · see citing works
Self-citationAllen, J., Frame, J. R., & Murray, A. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/2/312 · Cited by 86 · see citing works
Zahedi, E., Chellappan, K., Ali, M. A. M., & Singh, H. (2007) · Cardiovascular Engineering An International Journal · doi:10.1007/s10558-007-9037-5 · Cited by 60 · see citing works
Self-citationPhotoplethysmography Analysis of Artery Properties in Patients with Cardiovascular Diseases
Rubīns, U., Grabovskis, A., Grūbe, J., & Kukulis, I. (2008) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-69367-3_85 · Cited by 55 · see citing works
A System for Analysis of Arterial Blood Pressure Waveforms in Humans
Karamanoglu, M. (1997) · Computers and Biomedical Research · doi:10.1006/cbmr.1997.1450 · Cited by 49 · see citing works
Adaptive linear neural network filter for fetal ECG extraction
Reaz, M. B. I., & Wei, L. S. (2004) · doi:10.1109/icisip.2004.1287675 · Cited by 49 · see citing works
Self-citationDigital pulse contour analysis: investigating age-dependent indices of arterial compliance
Brumfield, A., & Andrew, M. E. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/5/003 · Cited by 45 · see citing works
Hussain, M., & Reaz, M. B. I. (2012) · Measurement Science Review · doi:10.2478/v10048-012-0005-x · Cited by 35 · see citing works
Self-citationAortic and arterial stiffness determination by photoplethysmographic technique
Huotari, M., Yliaska, N., Lantto, V., Maatta, K. E., & Kostamovaara, J. (2009) · Procedia Chemistry · doi:10.1016/j.proche.2009.07.310 · Cited by 15 · see citing works
Photoplethysmographic Augmentation Index as a Non Invasive Indicator for Vascular Assessments
Gonzalez, R., Manzo-Martínez, A., Delgado, J., Padilla, J. M. S., Trénor, B., Ferrero, J. M., & Sáiz, J. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-89208-3_279 · Cited by 8 · see citing works
Hardware realization of an efficient fetal QRS complex detection algorithm
Ibrahimy, M. I., Reaz, M. B. I., Ali, M. A. M., Khoon, T. H., & Ismail, A. F. (2006) · WSEAS Transactions on Circuits and Systems archive · Cited by 7 · see citing works
Self-citationNeural network based ECG signal analysis for heart rate detection
Reaz, M. B. I., Ibrahimy, M. I., & Rahim, R. A. (2006) · Cited by 1 · see citing works
Self-citationAn approach to detect QRS complex using backpropagation neural network
Reaz, M. B. I., Ibrahimy, M. I., & Rahim, R. A. (2006) · The International Islamic University Malaysia Repository (The International Islamic University Malaysia) · Cited by 1 · see citing works
Self-citation
Flagged first, then by citations
1 of the 21 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945 · see citing works
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 450 · see citing works
Blood Pressure Estimation from Photoplethysmogram Using a Spectro-Temporal Deep Neural Network
Slapničar, G., Mlakar, N., & Luštrek, M. (2019) · Sensors · doi:10.3390/s19153420 · Cited by 387 · see citing works
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
Charlton, P. H., Paliakaitė, B., Pilt, K., Bachler, M., Zanelli, S., Kulin, D., Allen, J., Hallab, M., Bianchini, E., Mayer, C. C., et al. (2021) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00392.2021 · Cited by 152 · see citing works
Assessment of Non-Invasive Blood Pressure Prediction from PPG and rPPG Signals Using Deep Learning
Schrumpf, F., Frenzel, P., Aust, C., Osterhoff, G., & Fuchs, M. (2021) · Sensors · doi:10.3390/s21186022 · Cited by 146 · see citing works
Vascular ageing: moving from bench towards bedside
Climie, R. E., Alastruey, J., Mayer, C. C., Schwarz, A., Laučytė-Cibulskienė, A., Voicehovska, J., Bianchini, E., Bruno, R. M., Charlton, P. H., Grillo, A., et al. (2023) · European Journal of Preventive Cardiology · doi:10.1093/eurjpc/zwad028 · Cited by 139 · see citing works
XGBoost Regression of the Most Significant Photoplethysmogram Features for Assessing Vascular Aging
Shin, H. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3151091 · Cited by 78 · see citing works
Advanced Uses of Pulse Oximetry for Monitoring Mechanically Ventilated Patients
Tusman, G., Böhm, S. H., & Suárez-Sipmann, F. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001283 · Cited by 70 · see citing works
Prediction of vascular aging based on smartphone acquired PPG signals
Dall’Olio, L., Curti, N., Remondini, D., Harb, Y. S., Asselbergs, F. W., Castellani, G., & Uh, H. (2020) · Scientific Reports · doi:10.1038/s41598-020-76816-6 · Cited by 70 · see citing works
Yokus, M. A., & Daniele, M. A.-A. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113249 · Cited by 60 · see citing works
New aging index using signal features of both photoplethysmograms and acceleration plethysmograms
Ahn, J. M. (2017) · Healthcare Informatics Research · doi:10.4258/hir.2017.23.1.53 · Cited by 58 · see citing works
Susana, E., Ramli, K., Murfi, H., & Apriantoro, N. H. (2022) · Information · doi:10.3390/info13020059 · Cited by 59 · see citing works
Fahoum, A. S. A., Al-Haija, A. O. A., & Alshraideh, H. A. (2023) · Bioengineering · doi:10.3390/bioengineering10020249 · Cited by 59 · see citing works
Hickey, M., Phillips, J. P., & Kyriacou, P. A. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-015-9761-0 · Cited by 49 · see citing works
Moscato, S., Giudice, S. L., Massaro, G., & Chiari, L. (2022) · Sensors · doi:10.3390/s22155831 · Cited by 51 · see citing works
The effect of vascular changes on the photoplethysmographic signal at different hand elevations
Hickey, M., Phillips, J. P., & Kyriacou, P. A. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/3/425 · Cited by 43 · see citing works
Surgical pleth index monitoring in perioperative pain management: usefulness and limitations
Oh, S. K., Won, Y. J., & Lim, B. G. (2023) · Korean Journal of Anesthesiology · doi:10.4097/kja.23158 · Cited by 43 · see citing works
Photoplethysmography—new applications for an old technology: a sleep technology review
Ryals, S. M., Chiang, A. A.-P., Schutte-Rodin, S., Chandrakantan, A., Verma, N., Holfinger, S. J., Abbasi-Feinberg, F., Bandyopadhyay, A., Baron, K. G., Bhargava, S., et al. (2022) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.10300 · Cited by 43 · see citing works
Wu, J., Li, C., Ho, Y., Wu, M., Huang, P., & Lin, C. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2513899 · Cited by 41 · see citing works
Chiarelli, A. M., Bianco, F., Perpetuini, D., Bucciarelli, V., Filippini, C., Cardone, D., Zappasodi, F., Gallina, S., & Merla, A. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.07.009 · Cited by 40 · see citing works
Multitask deep label distribution learning for blood pressure prediction
Qin, K., Huang, W. X., & Zhang, T. (2023) · Information Fusion · doi:10.1016/j.inffus.2023.02.019 · Cited by 39 · see citing works
Cuff-Less Blood Pressure Prediction Based on Photoplethysmography and Modified ResNet
Qin, C., Li, Y., Liu, C., & Ma, X. (2023) · Bioengineering · doi:10.3390/bioengineering10040400 · Cited by 39 · see citing works
Li, F., Yang, L., Shi, H., & Liu, C. (2017) · Artery Research · doi:10.1016/j.artres.2017.02.003 · Cited by 38 · see citing works
Andreozzi, E., Sabbadini, R., Centracchio, J., Bifulco, P., Irace, A., Breglio, G., & Riccio, M. (2022) · Sensors · doi:10.3390/s22197566 · Cited by 36 · see citing works
Zhong, Y., Koklu, A., Villalva, D. R., Zhang, Y., Hernandez, L. H., Moser, M., Hallani, R. K., McCulloch, I. A., Baran, D., & Inal, S. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202211479 · Cited by 33 · see citing works
Photoplethysmogram based vascular aging assessment using the deep convolutional neural network
Shin, H., Noh, G., & Choi, B. (2022) · Scientific Reports · doi:10.1038/s41598-022-15240-4 · Cited by 32 · see citing works
Advances in Cuffless Continuous Blood Pressure Monitoring Technology Based on PPG Signals
Qin, C., Wang, X., Xu, G., & Ma, X. (2022) · BioMed Research International · doi:10.1155/2022/8094351 · Cited by 31 · see citing works
Dutt, D. N., & Shruthi, S. (2015) · International Conference on Communications and Signal Processing (ICCSP) · doi:10.1109/iccsp.2015.7322766 · Cited by 30 · see citing works
Advances in PPG Sensors Data Acquisition With Light-to-Digital Converters: A Review
Chettri, N., Aprile, A., Bonizzoni, E., & Malcovati, P. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3420170 · Cited by 29 · see citing works
Robust blood pressure estimation from finger photoplethysmography using age-dependent linear models
Xing, X., Ma, Z., Zhang, M., Gao, X., Li, Y., Song, M., & Dong, W. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab755d · Cited by 28 · see citing works
Scenario Adaptive Cuffless Blood Pressure Estimation by Integrating Cardiovascular Coupling Effects
Qiu, S., Zhang, Y., Lau, S.-K., & Zhao, N. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3227235 · Cited by 27 · see citing works
Perpetuini, D., Chiarelli, A. M., Maddiona, L., Rinella, S., Bianco, F., Bucciarelli, V., Gallina, S., Perciavalle, V., Vinciguerra, V., Merla, A., et al. (2019) · Sensors · doi:10.3390/s19245570 · Cited by 27 · see citing works
Enhancing the Robustness of Smartphone Photoplethysmography: A Signal Quality Index Approach
Liu, I., Ni, S., & Peng, K. (2020) · Sensors · doi:10.3390/s20071923 · Cited by 26 · see citing works
Melinosky, C., Yang, S., Hu, P., Li, H.-C., Miller, C. H. T., Khan, I. R., MacKenzie, C. R., Chang, W.-T. W., Parikh, G. Y., Stein, D. M., et al. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.00761 · Cited by 25 · see citing works
Won, Y. J., Oh, S. K., Lim, B. G., Kim, Y. S., Lee, D. Y., & Lee, J. H. (2023) · BMC Anesthesiology · doi:10.1186/s12871-023-02011-5 · Cited by 22 · see citing works
Hong, K. S., Park, K. T., & Ahn, J. M. (2015) · Healthcare Informatics Research · doi:10.4258/hir.2015.21.1.30 · Cited by 21 · see citing works
Estimation of systolic blood pressure by Random Forest using heart sounds and a ballistocardiogram
González-Landaeta, R., Ramirez, B., & Mejia, J. (2022) · Scientific Reports · doi:10.1038/s41598-022-22205-0 · Cited by 21 · see citing works
Quality Assessment and Morphological Analysis of Photoplethysmography in Daily Life
Moscato, S., Palmerini, L., Palumbo, P., & Chiari, L. (2022) · Frontiers in Digital Health · doi:10.3389/fdgth.2022.912353 · Cited by 20 · see citing works
Pal, R., Rudas, Á., Kim, S., Chiang, J. N., Barney, A. M., & Cannesson, M. P. (2024) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2024.108283 · Cited by 22 · see citing works
Deep Learning based non-invasive diabetes predictor using Photoplethysmography signals
Srinivasan, V. B., & Foroozan, F. (2021) · European Signal Processing Conference (EUSIPCO) · doi:10.23919/eusipco54536.2021.9616351 · Cited by 17 · see citing works
Wu, K.-C., Martin, A., Renna, M., Robinson, M. B., Ozana, N. N., Carp, S. A., & Franceschini, M. A. (2023) · Neurophotonics · doi:10.1117/1.nph.10.3.035008 · Cited by 17 · see citing works
Nie, G., Zhao, Q., Tang, G., Li, Y., & Hong, S. (2025) · Communications Medicine · doi:10.1038/s43856-025-01188-9 · Cited by 18 · see citing works
Thakur, S., Chao, P. C.-P., & Tsai, C.-H. (2023) · Sensors · doi:10.3390/s23136180 · Cited by 16 · see citing works
Wong, M. K. F., Hei, H., Lim, S. Z., & Ng, E. Y. K. (2022) · Mathematical Biosciences & Engineering · doi:10.3934/mbe.2023045 · Cited by 17 · see citing works
Photoplethysmography Based Arrhythmia Detection and Classification
Neha, N., Kanawade, R. V., Tewary, S., & Sardana, H. K. (2019) · International Conference on Signal Processing and Integrated Networks (SPIN) · doi:10.1109/spin.2019.8711737 · Cited by 15 · see citing works
Park, J., & Shin, H. (2022) · JMIR Medical Informatics · doi:10.2196/33439 · Cited by 15 · see citing works
The Impact of Contact Force on Signal Quality Indices in Photoplethysmography Measurements
Cause, J. L., Morillo, Á. S., Naranjo, J. C. G., Stiens, J. H., & da Silva, B. (2024) · Applied Sciences · doi:10.3390/app14135704 · Cited by 14 · see citing works
Personalized PPG Normalization Based on Subject Heartbeat in Resting State Condition
Gasparini, F., Grossi, A., Giltri, M., & Bandini, S. (2022) · Signals · doi:10.3390/signals3020016 · Cited by 13 · see citing works
Shokouhmand, A., Wen, H., Khan, S., Puma, J. A., Patel, A., Green, P., Ayazi, F., & Tavassolian, N. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3218595 · Cited by 13 · see citing works
Wu, J., Li, C., Chen, G., Ho, Y., & Lin, C. (2017) · IET Systems Biology · doi:10.1049/iet-syb.2016.0046 · Cited by 13 · see citing works
Mao, P., Li, H., Shan, X., Davis, M., Tang, T., Zhang, Y., Tong, X., Xin, Y., Cheng, J., Li, L., et al. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c04494 · Cited by 12 · see citing works
Tsiakaka, O., Gosselin, B. J., & Feruglio, S. (2020) · Sensors · doi:10.3390/s20113302 · Cited by 12 · see citing works
Hamid, H. A., & Nayan, N. A. (2020) · International Journal of Online and Biomedical Engineering (iJOE) · doi:10.3991/ijoe.v16i09.13577 · Cited by 13 · see citing works
Prada, E. J. A., & Valencia, R. M. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.104335 · Cited by 12 · see citing works
Tran, K. T., Tran, T. T. T., Huynh, D. N., Le, N. K., Le, C. D., Mai, H. X., Linh, H. Q., & Nguyen, T.-L. (2025) · Sensors · doi:10.3390/s25216708 · Cited by 12 · see citing works
Myoelectric Pattern Recognition Performance Enhancement Using Nonlinear Features
Islam, M. J., Ahmad, S., Haque, F., Reaz, M. B. I., Bhuiyan, M. A. S., Minhad, K. N., & Islam, M. R. (2022) · Computational Intelligence and Neuroscience · doi:10.1155/2022/6414664 · Cited by 9 · see citing works
Self-citationBurton, T., Saiko, G., Cao, M., & Douplik, A. (2022) · Journal of Biophotonics · doi:10.1002/jbio.202200187 · Cited by 10 · see citing works
Anesthesiologist as Physiologist: Discussion and Examples of Clinical Waveform Analysis
Alian, A. A. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001468 · Cited by 10 · see citing works
Haghi, M., Danyali, S., Thurow, K., Warnecke, J. M., Wang, J., & Deserno, T. M. (2020) · Applied Sciences · doi:10.3390/app10165470 · Cited by 9 · see citing works
Noninvasive hemodynamic indices of vascular aging: an in silico assessment
Hong, J., Nandi, M., Charlton, P. H., & Alastruey, J. (2023) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00454.2023 · Cited by 10 · see citing works
Lin, C.-N., Chang, C.-P., Lin, J., Chang, J.-N., Hung, Y.-C., & Ko, P.-Y. (2025) · Frontiers in Physiology · doi:10.3389/fphys.2025.1695391 · Cited by 9 · see citing works
Multifunctional Photoplethysmography Sensor Design for Respiratory and Cardiovascular Diagnosis
Uguz, D. U., Venema, B., Leonhardt, S. K., & Teichmann, D. (2018) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-9038-7_167 · Cited by 9 · see citing works
Kanoga, S., Hoshino, T., Kamei, S., Kobayashi, T., Ohmori, T., Uchiyama, M., & Tada, M. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105029 · Cited by 9 · see citing works
Advancing PPG-based cf-PWV estimation with an integrated CNN-BiLSTM-Attention model
Abrisham, K. P., Alipour, K., Tarvirdizadeh, B., & Ghamari, M. (2024) · Signal Image and Video Processing · doi:10.1007/s11760-024-03496-4 · Cited by 8 · see citing works
Seo, J.-W., Choi, J.-M., Lee, K. H., & Kim, J. U. (2021) · Sensors · doi:10.3390/s21237782 · Cited by 8 · see citing works
Evaluation of PPG Feature Values Toward Biometric Authentication Against Presentation Attacks
Hinatsu, S., Suzuki, D., Ishizuka, H., Ikeda, S., & Oshiro, O. (2022) · IEEE Access · doi:10.1109/access.2022.3167667 · Cited by 8 · see citing works
Data-Driven Guided Attention for Analysis of Physiological Waveforms With Deep Learning
Martinez, J., Nowroozilarki, Z., Jafari, R., & Mortazavi, B. J. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3199199 · Cited by 8 · see citing works
Eid, A.-M., Elgamal, M. H., Fiol, A. G., Shelley, K. H., Wu, H., & Alian, A. A. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acd165 · Cited by 8 · see citing works
Chu, J., Yang, W.-T., Hsieh, T., & Yang, F.-L. (2021) · Biomedical Statistics and Informatics · doi:10.11648/j.bsi.20210601.12 · Cited by 8 · see citing works
Kido, K., Chen, Z., Huang, M., TAMURA, T., Chen, W., Ono, N., Takeuchi, M., Altaf‐Ul‐Amin, M., & Kanaya, S. (2021) · Life · doi:10.3390/life12010011 · Cited by 9 · see citing works
P2E-LGAN: PPG to ECG Reconstruction Methodology using LSTM based Generative Adversarial Network
Kumari, R., Sarkar, S., Dutta, D., Das, P., & Acharyya, A. (2024) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas58744.2024.10558493 · Cited by 7 · see citing works
Mobile medical systems for equitable healthcare
Chan, J., Goel, M., Gollakota, S., & Nandakumar, R. (2025) · Nature Reviews Bioengineering · doi:10.1038/s44222-025-00330-5 · Cited by 7 · see citing works
Qian, Z., Takezawa, Y., Shimokawa, K., Kino, H., Fukushima, T., Kiyoyama, K., & Tanaka, T. (2018) · Japanese Journal of Applied Physics · doi:10.7567/jjap.57.04fm11 · Cited by 7 · see citing works
Susana, E., & Ramli, K. (2021) · International Conference on Quality in Research (QiR): International Symposium on Electrical and Computer Engineering · doi:10.1109/qir54354.2021.9716164 · Cited by 7 · see citing works
Tu, T.-Y., & Chao, P. C.-P. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2927993 · Cited by 6 · see citing works
PPGTempStitch: A MATLAB Toolbox for Augmenting Annotated Photoplethsmogram Signals
Tang, Q., Chen, Z., Menon, C., Ward, R. K., & Elgendi, M. (2021) · Sensors · doi:10.3390/s21124007 · Cited by 6 · see citing works
Zhang, Y., Jiang, Z., Qi, L., Xu, L., Sun, X., Chu, X., Liu, Y., Zhang, T., & Greenwald, S. E. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.01590 · Cited by 6 · see citing works
Toward the monitoring of the spinal cord: A feasibility study
Tsiakaka, O., & Feruglio, S. (2018) · Microelectronics Journal · doi:10.1016/j.mejo.2018.01.026 · Cited by 6 · see citing works
Optical Biosensors—Principles of Operation and Applications
Błachowicz, T., Ehrmann, G., Stepula, E., & Ehrmann, A. (2026) · Micromachines · doi:10.3390/mi17050579 · Cited by 5 · see citing works
Abrisham, K. P., Alipour, K., Tarvirdizadeh, B., & Ghamari, M. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10782553 · Cited by 5 · see citing works
Nardelli, M., Greco, A., Vanello, N., & Scilingo, E. P. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630550 · Cited by 5 · see citing works
Design of a Two-Channel Forehead PPG Sensor
Du, Y. H., Sun, C., Zhang, M., & Mai, S. (2023) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas58349.2023.10388984 · Cited by 5 · see citing works
Photoplethysmographic assessment of arterial stiffness and endothelial function
Zheng, D., Yao, Y., Morrison, I., & Greenwald, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823374-0.00007-4 · Cited by 6 · see citing works
Hypothesis Scoring for Confidence-Aware Blood Pressure Estimation With Particle Filters
Martinez, J., Passage, B., Mortazavi, B. J., & Jafari, R. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3289192 · Cited by 6 · see citing works
Vahdani-Manaf, N. (2015) · Journal of Applied Sciences · doi:10.3923/jas.2015.1312.1317 · Cited by 5 · see citing works
Vascular Markers among Young Women with CVD Risk Factors
Aminuddin, A., Ugusman, A., Salamt, N., & Muhajir, M. (2019) · Sains Malaysiana · doi:10.17576/jsm-2019-4810-17 · Cited by 4 · see citing works
Kobayashi, M., Shinohara, T., & Usuda, S. (2021) · Journal of Physical Therapy Science · doi:10.1589/jpts.33.45 · Cited by 4 · see citing works
Přibil, J., Přibilová, A., & Frollo, I. (2023) · Measurement Science Review · doi:10.2478/msr-2023-0028 · Cited by 4 · see citing works
An Underscreen Fingerprint Sensor for Measurement of PPG and Blood Pressure Estimation
Nguyen, D. H., Chao, P. C.-P., Ngo, D. T., Huang, S., Huang, Y. T., Huang, M.-L., Chen, Y., & Huang, T.-W. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3541447 · Cited by 4 · see citing works
Photoplethysmogram analysis and applications: An Integrative Review (Preprint)
Shin, H., Park, J., Seok, H. S., & Kim, S. (2020) · JMIR Biomedical Engineering · doi:10.2196/25567 · Cited by 4 · see citing works
He, Z., Zhang, H., Chen, X., Shi, J., Bai, L., Fang, Z., & Wang, R. (2022) · Scientific Reports · doi:10.1038/s41598-022-22719-7 · Cited by 5 · see citing works
Abrisham, K. P., Alipour, K., Tarvirdizadeh, B., & Ghamari, M. (2023) · RSI International Conference on Robotics and Mechatronics (ICRoM) · doi:10.1109/icrom60803.2023.10412455 · Cited by 4 · see citing works
Wu, J., Lin, C., Kan, C., & Chen, W. (2019) · IET Science Measurement & Technology · doi:10.1049/iet-smt.2018.5330 · Cited by 4 · see citing works
Indexing cerebrovascular health using near-infrared spectroscopy
Afkhami, R. G., Walker, F. R., Ramadan, S. A., Wong, R. H. X., & Johnson, S. J. (2021) · Scientific Reports · doi:10.1038/s41598-021-94348-5 · Cited by 4 · see citing works
Clustered photoplethysmogram pulse wave shapes and their associations with clinical data
Zanelli, S., Eveilleau, K., Charlton, P. H., Ammi, M., Hallab, M., & El‐Yacoubi, M. A. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1176753 · Cited by 3 · see citing works
Vascular Age Prediction with PPG-Based LSTM Model
Abrisham, K. P., Alipour, K., Tarvirdizadeh, B., & Ghamari, M. (2023) · International Conference on Control, Instrumentation, and Automation · doi:10.1109/iccia61416.2023.10506360 · Cited by 3 · see citing works
Algorithm To Calculate Heart Rate By Removing Touch Errors And Algorithm Analysis
Chatterjee, A., & Roy, U. K. (2018) · International Conference on Circuits and Systems in Digital Enterprise Technology (ICCSDET) · doi:10.1109/iccsdet.2018.8821182 · Cited by 3 · see citing works
Edge computing design space exploration for heart rate monitoring
Miranda, J., Canabal, M. F., Gutiérrez-Martín, L., Lanza-Gutiérrez, J. M., & López-Ongil, C. (2022) · Integration · doi:10.1016/j.vlsi.2022.02.003 · Cited by 3 · see citing works
Smartphone-based measurement of cardiovascular healthcare: Advances and applications
Chen, X., Chen, J., Xu, H., He, T., Fridenfalk, M., & Lv, Z. (2025) · Measurement · doi:10.1016/j.measurement.2025.117347 · Cited by 2 · see citing works
- Authors
- Yousef, Q., Reaz, M. B. I., & Ali, M. A. M.
- Affiliations
- Taibah University (SA)
- National University of Malaysia (MY)
- Venue
- Measurement Science Review
- Publisher
- Walter de Gruyter GmbH
- Published
- 2012-01-01
- Volume
- 12
- Issue
- 6
- ISSN
- 1335-8871 (ISSN-L)
- OpenAlex
- W2014822627
- Cited by
- 126
- References
- 21
- Citations by year
- 2026: 4 · 2025: 11 · 2024: 11 · 2023: 20 · 2022: 23 · 2021: 17 · 2020: 8 · 2019: 9 · 2018: 9 · 2017: 5 · 2016: 3 · 2015: 6
- FWCI
- 1.09
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- Measurement Science Review (publishedVersion, cc-by-nc-nd)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- photoplethysmogram, aging, arterial compliance, arterial elasticity, dicrotic notch, inflection point, erectile dysfunction, subclinical atherosclerosis, vascular elasticity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review