Factors to consider when interrogating 3D culture models with plate readers or automated microscopes
Open accessAbstract
Along with the increased use of more physiologically relevant three-dimensional cell culture models comes the responsibility of researchers to validate new assay methods that measure events in structures that are physically larger and more complex compared to monolayers of cells. It should not be assumed that assays designed using monolayers of cells will work for cells cultured as larger three-dimensional masses. The size and barriers for penetration of molecules through the layers of cells result in a different microenvironment for the cells in the outer layer compared to the center of three-dimensional structures. Diffusion rates for nutrients and oxygen may limit metabolic activity which is often measured as a marker for cell viability. For assays that lyse cells, the penetration of reagents to achieve uniform cell lysis must be considered. For live cell fluorescent imaging assays, the diffusion of fluorescent probes and penetration of photons of light for probe excitation and fluorescent emission must be considered. This review will provide an overview of factors to consider when implementing assays to interrogate three dimensional cell culture models.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Both physical sectioning and optical sectioning face limitations when imaging spheroids exceeding several hundred micrometers in diameter due to scattering and absorption of excitation and emission light within intact tissue.
“both techniques face limitations when imaging spheroids exceeding several hundred micrometers in diameter due to scattering and absorption of excitation and emission light within intact tissue [249].”
From Modeling Tumor Microenvironment Complexity In Vitro: Spheroids as Physiologically Relevant Tumor Models and Strategies for Their Analysis (2025) · cites this paper as [249]
The “Imaging 3D cell models” section says absorption and scattering of excitation and emission light affect imaging, and Table 2 in “Reagents and probes for 3D cell imaging” gives limited light-penetration depths for live and fixed samples. The paper does not establish a several-hundred-micrometer spheroid diameter as a general cutoff, or say that physical sectioning faces the same light-limitation as optical sectioning. (LLM, conf=0.85)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Edmondson, R., Broglie, J. J., Adcock, A. F., & Yang, L. (2014) · ASSAY and Drug Development Technologies · doi:10.1089/adt.2014.573 · Cited by 2,515 · cited 4× · see citing works
“As a result of numerous published reports (Rimann and Graf-Hausner 2012; Edmondson et al. 2014; Fu et al. 2017) demonstrating that 3D culture models more accurately represent the in vivo situation, there has been a rapid adoption of a broad spectrum of simple to complex 3D models to study…”
BackgroundInfluentialTumor Evolution and Drug Response in Patient-Derived Organoid Models of Bladder Cancer
Lee, S. H., Hu, W., Matulay, J. T., Silva, M. V., Owczarek, T. B., Kim, K., Chua, C. W., Barlow, L. J., Kandoth, C., Williams, A. B., et al. (2018) · Cell · doi:10.1016/j.cell.2018.03.017 · Cited by 873 · see citing works
Multi-cell type human liver microtissues for hepatotoxicity testing
Messner, S., Agarkova, I., Moritz, W., & Kelm, J. M. (2013) · Archives of Toxicology · doi:10.1007/s00204-012-0968-2 · Cited by 319 · see citing works
Routine Optical Clearing of 3D-Cell Cultures: Simplicity Forward
Nürnberg, E., Vitacolonna, M., Klicks, J., von Molitor, E., Cesetti, T., Keller, F., Bruch, R., Ertongur-Fauth, T., Riedel, K., Scholz, P., et al. (2020) · Frontiers in Molecular Biosciences · doi:10.3389/fmolb.2020.00020 · Cited by 93 · see citing works
Flagged first, then by citations
Research works printed but not linked: 66
- Abbe E Beiträge zur Theorie des Mikroskops und der mikroskopischen Wahrnehmung Arch Mikrosk Anat 1873 9 413 468 10.1007/BF02956173 · DOI
- Aboulkheyr Es H Montazeri L Aref AR Vosough M Baharvand H Personalized cancer medicine: an organoid approach Trends Biotechnol 2018 36 358 371 10.1016/j.tibtech.2017.12.005 29366522 · DOI
- Artegiani B Clevers H Use and application of 3D-organoid technology Hum Mol Genet 2018 27 R99 R107 10.1093/hmg/ddy187 29796608 · DOI
- Auld DS, Coassin P, Coussens NP, Hensley P, Michael S, Sittampalam GS, Trask O, Wagner BK, Weidner JR, Wildey MJ, Dahlin JL (2020) Microplate selection and recommended practices in high-throughput screening and quantitative biology. In: Sittampalam GS, Grossman A, Brimacombe K, et al., editors. Assay Guidance Manual [Internet]. Bethesda (MD): Eli Lilly & Company and the National Center for Advancing Translational Sciences; 2004- Available from: https://www.ncbi.nlm.nih.gov/books/NBK558077/ 32520474
- Auld DS, Inglese J (2016) Interferences with luciferase reporter enzymes. In: Sittampalam GS, Grossman A, Brimacombe K, et al, editors. Assay guidance manual [internet]. Bethesda: Eli Lilly & Company and the National Center for Advancing Translational Sciences; 2004- Available from: https://www.ncbi.nlm.nih.gov/books/NBK374281/ 27478246
- Bhattacharya M Malinen MM Lauren P Lou YR Kuisma SW Kanninen L Lille M Corlu A GuGuen-Guillouzo C Ikkala O Laukkanen A Urtti A Yliperttula M Nanofibrillar cellulose hydrogel promotes three-dimensional liver cell culture J Control Release 2012 164 291 298 10.1016/j.jconrel.2012.06.039 22776290 · DOI
- Bissell MJ Rizki A Mian IS Tissue architecture: the ultimate regulator of breast epithelial function Curr Opin Cell Biol 2003 15 753 762 10.1016/j.ceb.2003.10.016 14644202 PMC2933200 · DOI
- Boutin ME Hoffman-Kim D Application and assessment of optical clearing methods for imaging of tissue-engineered neural stem cell spheres Tissue Eng C Methods 2015 21 292 302 10.1089/ten.tec.2014.0296 PMC4346659 25128373 · DOI
- Boutin ME Voss TC Titus SA Cruz-Gutierrez K Michael S Ferrer M A high-throughput imaging and nuclear segmentation analysis protocol for cleared 3D culture models Sci Rep 2018 8 11135 10.1038/s41598-018-29169-0 30042482 PMC6057966 · DOI
- Buchberger AR DeLaney K Johnson J Li L Mass spectrometry imaging: a review of emerging advancements and future insights Anal Chem 2018 90 240 265 10.1021/acs.analchem.7b04733 29155564 PMC5959842 · DOI
- Buchser W, Collins M, Garyantes T, Guha R, Haney S, Lemmon V, Li Z, Trask OJ (2004) Assay development guidelines for image-based high content screening, high content analysis and high content imaging. In: Sittampalam GS, Grossman a, Brimacombe K, et al., editors. Assay guidance manual [internet]. Bethesda (MD): Eli Lilly & Company and the National Center for Advancing Translational Sciences; 2004- Available from: https://www.ncbi.nlm.nih.gov/books/NBK100913/ 23035272
- Carragher N Piccinini F Tesei A Trask OJ Jr Bickle M Horvath P Concerns, challenges and promises of high-content analysis of 3D cellular models Nat Rev Drug Discov 2018 17 606 10.1038/nrd.2018.99 29977053 · DOI
- Cavo M Caria M Pulsoni I Beltrame F Fato M Scaglione S A new cell-laden 3D Alginate-Matrigel hydrogel resembles human breast cancer cell malignant morphology, spread and invasion capability observed “in vivo” Sci Rep 2018 8 5333 10.1038/s41598-018-23250-4 29593247 PMC5871779 · DOI
- Chen BC Legant WR Wang K Shao L Milkie DE Davidson MW Janetopoulos C Wu XS Hammer JA 3rd Liu Z English BP Mimori-Kiyosue Y Romero DP Ritter AT Lippincott-Schwartz J Fritz-Laylin L Mullins RD Mitchell DM Bembenek JN Reymann AC Bohme R Grill SW Wang JT Seydoux G Tulu US Kiehart DP Betzig E Lattice light-sheet microscopy: imaging molecules to embryos at high spatiotemporal resolution Science 2014 346 1257998 10.1126/science.1257998 25342811 PMC4336192 · DOI
- Eglen RM Reisine T Human iPS cell-derived patient tissues and 3D cell culture part 2: spheroids, organoids, and disease modeling SLAS Technol 2019 24 18 27 30798678
- Fu J Fernandez D Ferrer M Titus SA Buehler E Lal-Nag MA RNAi high-throughput screening of single- and multi-cell-type tumor spheroids: a comprehensive analysis in two and three dimensions SLAS Discov 2017 22 525 536 28277887
- Grist SM Nasseri SS Laplatine L Schmok JC Yao D Hua J Chrostowski L Cheung KC Long-term monitoring in a microfluidic system to study tumour spheroid response to chronic and cycling hypoxia Sci Rep 2019 9 17782 10.1038/s41598-019-54001-8 31780697 PMC6883080 · DOI
- Hall MP, Gruber MG, Hannah RR, Jennens-Clough ML, Wood KV (1998) Stabilization of firefly luciferase using directed evolution; Roda, a., et al., Eds. In bioluminescence and chemiluminescence: perspectives for the 21st century; Wiley; Chichester; pp. 392–395
- Hou S Tiriac H Sridharan BP Scampavia L Madoux F Seldin J Souza GR Watson D Tuveson D Spicer TP Advanced development of primary pancreatic organoid tumor models for high-throughput phenotypic drug screening SLAS Discov 2018 23 574 584 29673279 PMC6013403
- Hughes CS Postovit LM Lajoie GA Matrigel: a complex protein mixture required for optimal growth of cell culture Proteomics 2010 10 1886 1890 10.1002/pmic.200900758 20162561 · DOI · Paper page
- Huh D Matthews BD Mammoto A Montoya-Zavala M Hsin HY Ingber DE Reconstituting organ-level lung functions on a chip Science 2010 328 1662 1668 10.1126/science.1188302 20576885 PMC8335790 · DOI · Paper page
- Huisken J Swoger J Del Bene F Wittbrodt J Stelzer EH Optical sectioning deep inside live embryos by selective plane illumination microscopy Science 2004 305 1007 1009 10.1126/science.1100035 15310904 · DOI
- Idrees A Chiono V Ciardelli G Shah S Viebahn R Zhang X Salber J Validation of in vitro assays in three-dimensional human dermal constructs Int J Artif Organs 2018 41 779 788 10.1177/0391398818775519 29843544 PMC6210574 · DOI
- Kenny PA Lee GY Myers CA Neve RM Semeiks JR Spellman PT Lorenz K Lee EH Barcellos-Hoff MH Petersen OW Gray JW Bissell MJ The morphologies of breast cancer cell lines in three-dimensional assays correlate with their profiles of gene expression Mol Oncol 2007 1 84 96 10.1016/j.molonc.2007.02.004 18516279 PMC2391005 · DOI · Paper page
- Lancaster MA Knoblich JA Organogenesis in a dish: modeling development and disease using organoid technologies Science 2014 345 6194 1247125 12471-9 10.1126/science.1247125 25035496 · DOI · Paper page
- Lauterbur PC (1989) Image formation by induced local interactions. Examples employing nuclear magnetic resonance. 1973. Clin Orthop Relat Res:3–6 2663289
- Li L Zhou Q Voss TC Quick KL LaBarbera DV High-throughput imaging: focusing in on drug discovery in 3D Methods 2016 96 97 102 10.1016/j.ymeth.2015.11.013 26608110 PMC4766031 · DOI
- Li Z Xiao Y Peng J Locke D Holmes D Li L Hamilton S Cook E Myer L Vanderwall D Cloutier N Siddiqui AM Whitehead P Bishop R Zhao L Cvijic ME Quantifying drug tissue biodistribution by integrating high content screening with deep-learning analysis Sci Rep 2020 10 14408 10.1038/s41598-020-71347-6 32873881 PMC7463244 · DOI
- Liu TL Upadhyayula S Milkie DE Singh V Wang K Swinburne IA Mosaliganti KR Collins ZM Hiscock TW Shea J Kohrman AQ Medwig TN Dambournet D Forster R Cunniff B Ruan Y Yashiro H Scholpp S Meyerowitz EM Hockemeyer D Drubin DG Martin BL Matus DQ Koyama M Megason SG Long F Zhou J Peng H Visualization and analysis of 3D microscopic images PLoS Comput Biol 2012 8 e1002519 10.1371/journal.pcbi.1002519 22719236 PMC3375219 · DOI
- Long F, Zhou J, Peng H (2012) Visualization and analysis of 3D microscopic images. PLoS Comput Biol 8:e1002519 PMC3375219 22719236
- Madoux F Tanner A Vessels M Willetts L Hou S Scampavia L Spicer TP A 1536-well 3D viability assay to assess the cytotoxic effect of drugs on spheroids SLAS Discov 2017 22 516 524 28346088
- Nguyen EH Daly WT Le NNT Farnoodian M Belair DG Schwartz MP Lebakken CS Ananiev GE Saghiri MA Knudsen TB Sheibani N Murphy WL Versatile synthetic alternatives to Matrigel for vascular toxicity screening and stem cell expansion Nat Biomed Eng 2017 1 0096 10.1038/s41551-017-0096 29104816 PMC5667681 · DOI · Paper page
- Niles WD Coassin PJ Cyclic olefin polymers: innovative materials for high-density multiwell plates Assay Drug Dev Technol 2008 6 577 590 10.1089/adt.2008.134 18537466 · DOI
- North AJ Seeing is believing? A beginners' guide to practical pitfalls in image acquisition J Cell Biol 2006 172 9 18 10.1083/jcb.200507103 16390995 PMC2063524 · DOI
- Pamies D Barreras P Block K Makri G Kumar A Wiersma D Smirnova L Zang C Bressler J Christian KM Harris G Ming GL Berlinicke CJ Kyro K Song H Pardo CA Hartung T Hogberg HT A human brain microphysiological system derived from induced pluripotent stem cells to study neurological diseases and toxicity ALTEX 2017 34 362 376 10.14573/altex.1609122 27883356 PMC6047513 · DOI
- Peel S Corrigan AM Ehrhardt B Jang KJ Caetano-Pinto P Boeckeler M Rubins JE Kodella K Petropolis DB Ronxhi J Kulkarni G Foster AJ Williams D Hamilton GA Ewart L Introducing an automated high content confocal imaging approach for organs-on-chips Lab Chip 2019 19 410 421 10.1039/C8LC00829A 30663729 · DOI
- Phan N Hong JJ Tofig B Mapua M Elashoff D Moatamed NA Huang J Memarzadeh S Damoiseaux R Soragni A A simple high-throughput approach identifies actionable drug sensitivities in patient-derived tumor organoids Commun Biol 2019 2 78 10.1038/s42003-019-0305-x 30820473 PMC6389967 · DOI · Paper page
- Piston DW Choosing objective lenses: the importance of numerical aperture and magnification in digital optical microscopy Biol Bull 1998 195 1 4 10.2307/1542768 9739546 · DOI
- Polini A Del Mercato LL Barra A Zhang YS Calabi F Gigli G Towards the development of human immune-system-on-a-chip platforms Drug Discov Today 2019 24 517 525 10.1016/j.drudis.2018.10.003 30312743 PMC6440212 · DOI
- Quereda V Hou S Madoux F Scampavia L Spicer TP Duckett D A cytotoxic three-dimensional-spheroid, high-throughput assay using patient-derived Glioma stem cells SLAS Discov 2018 23 842 849 29750582 PMC6102052
- Richardson DS Lichtman JW Clarifying tissue clearing Cell 2015 162 246 257 10.1016/j.cell.2015.06.067 26186186 PMC4537058 · DOI · Paper page
- Rimann M Graf-Hausner U Synthetic 3D multicellular systems for drug development Curr Opin Biotechnol 2012 23 803 809 10.1016/j.copbio.2012.01.011 22326911 · DOI
- Riss TL, Moravec RA, Niles AL, Duellman S, Benink HA, Worzella TJ, Minor L (2016) Cell viability assays. In: Sittampalam GS, Grossman a, Brimacombe K, et al., editors. Assay guidance manual [internet]. Bethesda (MD): Eli Lilly & Company and the National Center for Advancing Translational Sciences; 2004- Available from: https://www.ncbi.nlm.nih.gov/books/NBK144065/
- Roerink SF Sasaki N Lee-Six H Young MD Alexandrov LB Behjati S Mitchell TJ Grossmann S Lightfoot H Egan DA Pronk A Smakman N van Gorp J Anderson E Gamble SJ Alder C van de Wetering M Campbell PJ Stratton MR Clevers H Intra-tumour diversification in colorectal cancer at the single-cell level Nature 2018 556 457 462 10.1038/s41586-018-0024-3 29643510 · DOI
- Scheeder C Heigwer F Boutros M Machine learning and image-based profiling in drug discovery Curr Opin Syst Biol 2018 10 43 52 10.1016/j.coisb.2018.05.004 30159406 PMC6109111 · DOI
- Seeley EH Caprioli RM 3D imaging by mass spectrometry: a new frontier Anal Chem 2012 84 2105 2110 10.1021/ac2032707 22276611 PMC3296907 · DOI
- Shan F Close DA Camarco DP Johnston PA High-content screening comparison of cancer drug accumulation and distribution in two-dimensional and three-dimensional culture models of head and neck cancer Assay Drug Dev Technol 2018 16 27 50 10.1089/adt.2017.812 29215913 PMC5775115 · DOI
- Shi W Kwon J Huang Y Tan J Uhl CG He R Zhou C Liu Y Facile tumor spheroids formation in Large quantity with controllable size and high uniformity Sci Rep 2018 8 6837 10.1038/s41598-018-25203-3 29717201 PMC5931581 · DOI
- Siedentopf H Zsigmondy R Uber Sichtbarmachung und Größenbestimmung ultramikoskopischer Teilchen, mit besonderer Anwendung auf Goldrubingläser Ann Phys 1902 315 1 39 10.1002/andp.19023150102 · DOI
- Simian M Bissell MJ Organoids: a historical perspective of thinking in three dimensions J Cell Biol 2017 216 31 40 10.1083/jcb.201610056 28031422 PMC5223613 · DOI · Paper page
- Sirenko O Mitlo T Hesley J Luke S Owens W Cromwell EF High-content assays for characterizing the viability and morphology of 3D cancer spheroid cultures Assay Drug Dev Technol 2015 13 402 414 10.1089/adt.2015.655 26317884 PMC4556086 · DOI
- Swinehart DF The Beer-Lambert Law J Chem Educ 1962 39 333 10.1021/ed039p333 · DOI · Paper page
- Talbot NC Caperna TJ Proteome array identification of bioactive soluble proteins/peptides in Matrigel: relevance to stem cell responses Cytotechnology 2015 67 873 883 10.1007/s10616-014-9727-y 24744128 PMC4545444 · DOI
- Tapias LF Ott HC Decellularized scaffolds as a platform for bioengineered organs Curr Opin Organ Transplant 2014 19 145 152 10.1097/MOT.0000000000000051 24480969 PMC4568185 · DOI
- Thurber GM Wittrup KD Quantitative spatiotemporal analysis of antibody fragment diffusion and endocytic consumption in tumor spheroids Cancer Res 2008 68 3334 3341 10.1158/0008-5472.CAN-07-3018 18451160 PMC2831542 · DOI
- Tibbitt MW Anseth KS Hydrogels as extracellular matrix mimics for 3D cell culture Biotechnol Bioeng 2009 103 655 663 10.1002/bit.22361 19472329 PMC2997742 · DOI · Paper page
- Trask OJ Jr Moore A LeCluyse EL A micropatterned hepatocyte coculture model for assessment of liver toxicity using high-content imaging analysis Assay Drug Dev Technol 2014 12 16 27 10.1089/adt.2013.525 24444127 · DOI
- van den Brand D Massuger LF Brock R Verdurmen WP Mimicking tumors: toward more predictive in vitro models for peptide- and protein-conjugated drugs Bioconjug Chem 2017 28 846 856 10.1021/acs.bioconjchem.6b00699 28122451 PMC5355905 · DOI
- Voie AH Burns DH Spelman FA Orthogonal-plane fluorescence optical sectioning: three-dimensional imaging of macroscopic biological specimens J Microsc 1993 170 229 236 10.1111/j.1365-2818.1993.tb03346.x 8371260 · DOI
- Vukicevic S Kleinman HK Luyten FP Roberts AB Roche NS Reddi AH Identification of multiple active growth factors in basement membrane Matrigel suggests caution in interpretation of cellular activity related to extracellular matrix components Exp Cell Res 1992 202 1 8 10.1016/0014-4827(92)90397-Q 1511725 · DOI · Paper page
- Wallis JW Miller TR Lerner CA Kleerup EC Three-dimensional display in nuclear medicine IEEE Trans Med Imaging 1989 8 297 230 10.1109/42.41482 18230529 · DOI
- Wenzel C Riefke B Grundemann S Krebs A Christian S Prinz F Osterland M Golfier S Rase S Ansari N Esner M Bickle M Pampaloni F Mattheyer C Stelzer EH Parczyk K Prechtl S Steigemann P 3D high-content screening for the identification of compounds that target cells in dormant tumor spheroid regions Exp Cell Res 2014 323 131 143 10.1016/j.yexcr.2014.01.017 24480576 · DOI
- Wiener N (1964) Extrapolation, interpolation, and smoothing of stationary time series. MIT press; Cambridge, mass
- Wilson KM Mathews-Griner LA Williamson T Guha R Chen L Shinn P McKnight C Michael S Klumpp-Thomas C Binder ZA Ferrer M Gallia GL Thomas CJ Riggins GJ Mutation profiles in Glioblastoma 3D Oncospheres modulate drug efficacy SLAS Technol 2019 24 28 40 30289729 PMC7058093
- Zhang B Radisic M Organ-on-a-chip devices advance to market Lab Chip 2017 17 2395 2420 10.1039/C6LC01554A 28617487 · DOI · Paper page
- Zhu X Huang L Zheng Y Song Y Xu Q Wang J Si K Duan S Gong W Ultrafast optical clearing method for three-dimensional imaging with cellular resolution Proc Natl Acad Sci 2019 116 11480 11489 10.1073/pnas.1819583116 31101714 PMC6561250 · DOI
Cited by
Sorted by citations
Shah, S., & D’Souza, G. G. M. (2025) · Cells · doi:10.3390/cells14100732 · Cited by 66 · see citing works
“Nevertheless, both techniques face limitations when imaging spheroids exceeding several hundred micrometers in diameter due to scattering and absorption of excitation and emission light within intact tissue [249].”
- Authors
- Riss, T., & Trask, O. J.
- Affiliations
- Promega (United States) (US)
- PerkinElmer (United States) (US)
- Corresponding author
- Riss, Terry
- ORCID
- Riss, Terry
- Venue
- In Vitro Cellular & Developmental Biology - Animal
- Published
- 2021-02
- Volume
- 57
- Issue
- 2
- Pages
- 238-256
- ISSN
- 1071-2690 (ISSN-L)
- 1543-706X
- PMC
- PMC7946695
- OpenAlex
- W3128104053
- Cited by
- 26
- References
- 4
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 5 · 2023: 6 · 2022: 5 · 2021: 4
- FWCI
- 0.42
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- In Vitro Cellular & Developmental Biology - Animal (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Health Sciences › Medicine › Oncology › Cancer Cells and Metastasis
- Keywords
- 3D cell culture, assay validation, plate reader, automated microscope, cell viability, cell lysis, light penetration, live-cell imaging
- MeSH terms
- Animals, Automation, Humans, Microscopy, Models, Biological, Cell Culture Techniques, Microfluidics, Tissue Scaffolds
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review