Noninvasive Measurement of Cerebral Blood Flow and Blood Oxygenation Using Near-Infrared and Diffuse Correlation Spectroscopies in Critically Brain-Injured Adults
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
BackgroundThis study assesses the utility of a hybrid optical instrument for noninvasive transcranial monitoring in the neurointensive care unit. The instrument is based on diffuse correlation spectroscopy (DCS) for measurement of cerebral blood flow (CBF), and near-infrared spectroscopy (NIRS) for measurement of oxy- and deoxy-hemoglobin concentration. DCS/NIRS measurements of CBF and oxygenation from frontal lobes are compared with concurrent xenon-enhanced computed tomography (XeCT) in patients during induced blood pressure changes and carbon dioxide arterial partial pressure variation.MethodsSeven neurocritical care patients were included in the study. Relative CBF measured by DCS (rCBFDCS), and changes in oxy-hemoglobin (ΔHbO2), deoxy-hemoglobin (ΔHb), and total hemoglobin concentration (ΔTHC), measured by NIRS, were continuously monitored throughout XeCT during a baseline scan and a scan after intervention. CBF from XeCT regions-of-interest (ROIs) under the optical probes were used to calculate relative XeCT CBF (rCBFXeCT) and were then compared to rCBFDCS. Spearman’s rank coefficients were employed to test for associations between rCBFDCS and rCBFXeCT, as well as between rCBF from both modalities and NIRS parameters.ResultsrCBFDCS and rCBFXeCT showed good correlation (rs = 0.73, P = 0.010) across the patient cohort. Moderate correlations between rCBFDCS and ΔHbO2/ΔTHC were also observed. Both NIRS and DCS distinguished the effects of xenon inhalation on CBF, which varied among the patients.ConclusionsDCS measurements of CBF and NIRS measurements of tissue blood oxygenation were successfully obtained in neurocritical care patients. The potential for DCS to provide continuous, noninvasive bedside monitoring for the purpose of CBF management and individualized care is demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE THEORY AND APPLICATIONS OF THE EXCHANGE OF INERT GAS AT THE LUNGS AND TISSUES
KETY, S. S. (1951) · Pharmacological Reviews · doi:10.1016/s0031-6997(25)07246-1 · Cited by 1,663
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
Pine, D. J., Weitz, D. A., Chaikin, P. M., & Herbolzheimer, E. (1988) · Physical Review Letters · doi:10.1103/physrevlett.60.1134 · Cited by 1,162
Regional Cerebral Blood Flow Estimated by 133 Xenon Inhalation
OBRIST, W. D., THOMPSON, H. K., WANG, H. S., & WILKINSON, W. E. (1975) · Stroke · doi:10.1161/01.str.6.3.245 · Cited by 859
Multiple light scattering from disordered media. The effect of brownian motion of scatterers
Maret, G., & Wolf, P. E. (1987) · Zeitschrift f�r Physik B Condensed Matter · doi:10.1007/bf01303762 · Cited by 724
Boas, D. A., & Yodh, A. G. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000192 · Cited by 606
Self-citationScattering and Imaging with Diffusing Temporal Field Correlations
Boas, D. A., Campbell, L. E., & Yodh, A. G. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.1855 · Cited by 519
Self-citationDuncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Fallon, P., Tyszczuk, L., Cope, M., & Delpy, D. T. (1996) · Pediatric Research · doi:10.1203/00006450-199605000-00025 · Cited by 469
Cullen, S. C., & Gross, E. G. (1951) · Science · doi:10.1126/science.113.2942.580 · Cited by 460
Optical brain imaging in vivo: techniques and applications from animal to man
Hillman, E. M. C. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2789693 · Cited by 436
Cited by
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Self-citationDiffuse correlation spectroscopy for non-invasive, micro-vascular cerebral blood flow measurement
Durduran, T., & Yodh, A. G. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.017 · Cited by 536
Self-citationLe Roux, P., Menon, D. K., Citerio, G., Vespa, P., Bader, M. K., Brophy, G. M., Diringer, M. N., Stocchetti, N., Videtta, W., Armonda, R., et al. (2014) · Neurocritical Care · doi:10.1007/s12028-014-0041-5 · Cited by 467
Statistical analysis of fNIRS data: A comprehensive review
Tak, S., & Ye, J. C. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.016 · Cited by 465
fNIRS Study of Walking and Walking While Talking in Young and Old Individuals
Holtzer, R., Mahoney, J. R., Izzetoglu, M., Izzetoglu, K., Onaral, B., & Verghese, J. (2011) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/glr068 · Cited by 445
Le Roux, P., Menon, D. K., Citerio, G., Vespa, P., Bader, M. K., Brophy, G. M., Diringer, M. N., Stocchetti, N., Videtta, W., Armonda, R., et al. (2014) · Intensive Care Medicine · doi:10.1007/s00134-014-3369-6 · Cited by 306
Cerebral Blood Flow Autoregulation and Dysautoregulation
Armstead, W. M. (2016) · Anesthesiology Clinics · doi:10.1016/j.anclin.2016.04.002 · Cited by 295
Modified Beer-Lambert law for blood flow
Baker, W. B., Parthasarathy, A. B., Busch, D. R., Mesquita, R. C., Greenberg, J. H., & Yodh, A. G. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.004053 · Cited by 283
Self-citationReactive hyperemia: a review of methods, mechanisms, and considerations
Rosenberry, R., & Nelson, M. D. (2020) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00339.2019 · Cited by 242
Diffuse correlation spectroscopy for measurement of cerebral blood flow: future prospects
Buckley, E. M., Parthasarathy, A. B., Grant, P. E., Yodh, A. G., & Franceschini, M. A. (2014) · Neurophotonics · doi:10.1117/1.nph.1.1.011009 · Cited by 216
“DCS has been successfully applied to monitor rCBF during clinical interventions, such as postural manipulation or blood pressure regulation in patients with ischemic stroke,(41) traumatic brain injury, and subarachnoid hemorrhage.(42,43) These works have demonstrated the need (and potential) for individualized monitor…”
MethodSelf-citationDurduran, T., Zhou, C., Buckley, E. M., Kim, M. N., Yu, G., Choe, R., Gaynor, J. W., Spray, T. L., Durning, S. M., Mason, S. E., et al. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3425884 · Cited by 196
Self-citationDirect measurement of tissue blood flow and metabolism with diffuse optics
Mesquita, R. C., Durduran, T., Yu, G., Buckley, E. M., Kim, M. N., Zhou, C., Choe, R., Sunar, U., & Yodh, A. G. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0232 · Cited by 195
Self-citationEstablishing the diffuse correlation spectroscopy signal relationship with blood flow
Boas, D. A., Sakadžic, S., Selb, J., Farzam, P., Franceschini, M. A., & Carp, S. A. (2016) · Neurophotonics · doi:10.1117/1.nph.3.3.031412 · Cited by 181
Selb, J., Boas, D. A., Chan, S.-T., Evans, K. C., Buckley, E. M., & Carp, S. A. (2014) · Neurophotonics · doi:10.1117/1.nph.1.1.015005 · Cited by 165
“assessed by other modalities such as transcranial Doppler (TCD) ultrasonography,11–13 phase-encoded velocity mapping magnetic resonance imaging (MRI),(14) and Xenon-enhanced computed tomography.(15) NIRS, and more recently and sporadi-”
MethodSelf-citationGurley, K., Shang, Y., & Yu, G. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.7.075010 · Cited by 81
Self-citationShang, Y., Gurley, K., Symons, B., Long, D., Srikuea, R., Crofford, L. J., Peterson, C. A., & Yu, G. (2012) · Arthritis Research & Therapy · doi:10.1186/ar4079 · Cited by 64
“Although this unit is different from the classical blood flow unit in biological tissues (ml/min/100 ml), its percentage changes have been found to correlate well with the blood flow changes measured by many other established modalities [32-36].”
BackgroundMethodSelf-citationKim, D. H. (2013) · Pain Physician · doi:10.36076/ppj.2013/16/117 · Cited by 24
Metadata
- Authors
- Kim, M. N., Durduran, T., Frangos, S., Edlow, B. L., Buckley, E. M., Moss, H. E., Zhou, C., Yu, G., Choe, R., Maloney-Wilensky, E., Wolf, R. L., Grady, M. S., Greenberg, J. H., Levine, J. M., Yodh, A. G., Detre, J. A., & Kofke, W. A.
- Venue
- Neurocritical Care
- Published
- 2009-11-12
- Volume
- 12
- Issue
- 2
- Pages
- 173-180
- ISSN
- 1541-6933 (ISSN-L)
- 1556-0961
- OpenAlex
- W1978299946
- Cited by
- 306
- References
- 23
- FWCI
- 12.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.