A Defined Methodology for Reliable Quantification of Western Blot Data
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Chemiluminescent western blotting has been in common practice for over three decades, but its use as a quantitative method for measuring the relative expression of the target proteins is still debatable. This is mainly due to the various steps, techniques, reagents, and detection methods that are used to obtain the associated data. In order to have confidence in densitometric data from western blots, researchers should be able to demonstrate statistically significant fold differences in protein expression. This entails a necessary evolution of the procedures, controls, and the analysis methods. We describe a methodology to obtain reliable quantitative data from chemiluminescent western blots using standardization procedures coupled with the updated reagents and detection methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Towbin, H., Staehelin, T., & Gordon, J. (1979) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.76.9.4350 · Cited by 53,385
Reversible Ponceau staining as a loading control alternative to actin in Western blots
Romero-Calvo, I., Ocón, B., Martínez-Moya, P., Suárez, M. D., Zarzuelo, A., Martínez-Augustin, O., & de Medina, F. S. (2010) · Analytical Biochemistry · doi:10.1016/j.ab.2010.02.036 · Cited by 771
Aldridge, G. M., Podrebarac, D. M., Greenough, W. T., & Weiler, I. J. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.05.003 · Cited by 476 · cited 1×
“However, these proteins are generally highly expressed in samples and are frequently overloaded in the gel lane with the target protein such that they would not serve to normalize the loading [12, 13].”
BackgroundCoomassie staining as loading control in Western blot analysis
Welinder, C., & Ekblad, L. (2011) · Journal of Proteome Research · doi:10.1021/pr1011476 · Cited by 463 · cited 1×
“In order to avoid these issues, the total lane density of transferred protein on the membrane is being used for the normalization in lieu of the traditional loading controls [18–22].”
MethodKURIEN, B., & SCOFIELD, R. (2006) · Methods · doi:10.1016/j.ymeth.2005.11.007 · Cited by 456
Stain-Free technology as a normalization tool in Western blot analysis
Gürtler, A., Kunz, N., Gomolka, M., Hornhardt, S., Friedl, A. A., McDonald, K., Kohn, J. E., & Posch, A. (2013) · Analytical Biochemistry · doi:10.1016/j.ab.2012.10.010 · Cited by 366
Ferguson, R. E., Carroll, H. P., Harris, A., Maher, E. R., Selby, P. J., & Banks, R. E. (2005) · PROTEOMICS · doi:10.1002/pmic.200400941 · Cited by 260
β‐Actin is not a reliable loading control in Western blot analysis
Dittmer, A., & Dittmer, J. (2006) · ELECTROPHORESIS · doi:10.1002/elps.200500785 · Cited by 168
Comparison of Stain-Free gels with traditional immunoblot loading control methodology
Colella, A. D., Chegeni, N., Tea, M. N., Gibbins, I. L., Williams, K. A., & Chataway, T. (2012) · Analytical Biochemistry · doi:10.1016/j.ab.2012.08.015 · Cited by 140
Housekeeping genes; expression levels may change with density of cultured cells
Greer, S. N., Honeywell, R., Geletu, M., Arulanandam, R., & Raptis, L. H. (2010) · Journal of Immunological Methods · doi:10.1016/j.jim.2010.02.006 · Cited by 128
Cited by
The Design of a Quantitative Western Blot Experiment
Taylor, S. C., & Posch, A. (2014) · BioMed Research International · doi:10.1155/2014/361590 · Cited by 408
Self-citationA systematic approach to quantitative Western blot analysis
Pillai-Kastoori, L., Schutz-Geschwender, A. R., & Harford, J. A. (2020) · Analytical Biochemistry · doi:10.1016/j.ab.2020.113608 · Cited by 407
An overview of technical considerations for Western blotting applications to physiological research
Bass, J. J., Wilkinson, D. J., Rankin, D., Phillips, B. E., Szewczyk, N. J., Smith, K., & Atherton, P. J. (2017) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.12702 · Cited by 404
The necessity of and strategies for improving confidence in the accuracy of western blots
Ghosh, R., Gilda, J. E., & Gomes, A. V. (2014) · Expert Review of Proteomics · doi:10.1586/14789450.2014.939635 · Cited by 305
Protein purification and analysis: next generation Western blotting techniques
Mishra, M., Tiwari, S., & Gomes, A. V. (2017) · Expert Review of Proteomics · doi:10.1080/14789450.2017.1388167 · Cited by 301
An analysis of critical factors for quantitative immunoblotting
Janes, K. A. (2015) · Science Signaling · doi:10.1126/scisignal.2005966 · Cited by 206
“Surprisingly, there are few objective studies on quantitative immunoblotting in the primary literature (2, 3).”
Western Blotting (immunoblotting): History, Theory, Uses, Protocol and Problems
Sule, R., Rivera, G., & Gomes, A. V. (2023) · BioTechniques · doi:10.2144/btn-2022-0034 · Cited by 180
Tubulin or Not Tubulin: Heading Toward Total Protein Staining as Loading Control in Western Blots
Moritz, C. P. (2017) · PROTEOMICS · doi:10.1002/pmic.201600189 · Cited by 158
“[53] Sypro Ruby was shown to be more accurate in reflecting the differences in protein concentration than GAPDH and β-actin, and was therefore suggested as an appropriate loading control (Table 1 [20]).”
BackgroundMethodInfluentialTaylor, S. C., Carbonneau, J., Shelton, D. N., & Boivin, G. (2015) · Journal of Virological Methods · doi:10.1016/j.jviromet.2015.08.014 · Cited by 142
Self-citationXu, J., Wang, X., Chen, J., Chen, S., Li, Z., Liu, H., Bai, Y., & Zhi, F. (2020) · Theranostics · doi:10.7150/thno.47683 · Cited by 109
“Western blotting was performed as described in a previously reported protocol [22].”
MethodMultiplex quantitative assays indicate a need for reevaluating reported small-molecule TrkB agonists
Boltaev, U., Meyer, Y., Tolibzoda, F., Jacques, T., Gassaway, M., Xu, Q., Wagner, F., Zhang, Y.-L., Palmer, M., Holson, E., et al. (2017) · Science Signaling · doi:10.1126/scisignal.aal1670 · Cited by 94
Narayan, N., Mandhair, H., Smyth, E., Dakin, S. G., Kiriakidis, S., Wells, L., Owen, D., Sabokbar, A., & Taylor, P. (2017) · PLOS ONE · doi:10.1371/journal.pone.0185767 · Cited by 79
Effective Top-Down LC/MS+ Method for Assessing Actin Isoforms as a Potential Cardiac Disease Marker
Chen, Y.-C., Ayaz-Guner, S., Peng, Y., Lane, N. M., Locher, M. R., Kohmoto, T., Larsson, L., Moss, R. L., & Ge, Y. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01745 · Cited by 31
Des Marteaux, L. E., Kullik, S. A., Habash, M., & Schmidt, J. M. (2020) · Microbial Ecology · doi:10.1007/s00248-020-01527-4 · Cited by 15
González-Santana, A., Marrero-Hernández, S., Dorta, I., Hernández, M., Pinto, F. M., Báez, D., Bello, A. R., Candenas, L., & Almeida, T. A. (2016) · Fertility and Sterility · doi:10.1016/j.fertnstert.2016.07.007 · Cited by 11
Ferreira, S. R., Goyeneche, A. A., Heber, M. F., Abruzzese, G. A., Ferrer, M. J., Telleria, C. M., & Motta, A. B. (2021) · Molecular and Cellular Endocrinology · doi:10.1016/j.mce.2020.111045 · Cited by 8
Metadata
- Authors
- Taylor, S. C., Berkelman, T., Yadav, G., & Hammond, M.
- Venue
- Molecular Biotechnology
- Published
- 2013-05-25
- Volume
- 55
- Issue
- 3
- Pages
- 217-226
- ISSN
- 1073-6085 (ISSN-L)
- 1559-0305
- OpenAlex
- W2069697511
- Cited by
- 397
- References
- 17
- FWCI
- 7.93
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.