The value of Bayesian penalized likelihood reconstruction for improving lesion conspicuity of malignant lung tumors on 18F-FDG PET/CT: comparison with ordered subset expectation maximization reconstruction incorporating time-of-flight model and point spread function correction
Open accessAbstract
Objective To evaluate the value of Bayesian penalized likelihood (BPL) reconstruction for improving lesion conspicuity of malignant lung tumors on 18 F-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography computed tomography (PET/CT) as compared with the ordered subset expectation maximization (OSEM) reconstruction incorporating time-of-flight (TOF) model and point-spread-function (PSF) correction. Methods Twenty-nine patients with primary or metastatic lung cancers who underwent 18 F-FDG PET/CT were retrospectively studied. PET images were reconstructed with OSEM + TOF, OSEM + TOF + PSF, and BPL with noise penalty strength β-value of 200, 400, 600, and 800. The signal-to-noise ratio (SNR) was determined in normal liver parenchyma. Lung lesion conspicuity was evaluated in 50 lung lesions by using a 4-point scale (0, no visible; 1, poor; 2, good; 3, excellent conspicuity). Two observers were independently asked to choose the most preferred reconstruction for detecting the lung lesions on a per-patient level. The maximum standardized uptake value (SUV max) was measured in each of the 50 lung lesions. Results Liver SNR on the images reconstructed by BPL with β-value of 600 and 800 (17.8 ± 3.7 and 22.5 ± 4.6, respectively) was significantly higher than that by OSEM + TOF + PSF (15.0 ± 3.4, p < 0.0001). BPL with β-value of 600 was chosen most frequently as the preferred reconstruction algorithm for lung lesion assessment by both observers. The conspicuity score of the lung lesions < 10 mm in diameter on images reconstructed by BPL with β-value of 600 was significantly greater than that with OSEM + TOF + PSF (2.2 ± 0.8 vs 1.6 ± 0.9, p < 0.0001), while the conspicuity score of the lesions ≥ 10 mm in diameter was not significantly different between BPL with β-value of 600 and OSEM + TOF + PSF. The mean SUV max was increased by BPL with β-value of 600 for the lung lesions with < 10 mm in diameter, compared to OSEM + TOF + PSF (3.4 ± 3.1 to 4.2 ± 3.5, p = 0.001). In contrast, BPL with β-value of 600 did not provide increased SUV max for the lesions ≥ 10 mm in diameter. Conclusion BPL reconstruction significantly improves the detection of small inconspicuous malignant tumors in the lung, improving the diagnostic performance of PET/CT.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Conflicting results were reported by other authors who did not find higher lesion conspicuity or detection rates with PSF in small patient samples.
“Conflicting results were reported by other authors who did not find higher lesion conspicuity or detection rates with PSF in small patient samples [162,164,165].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [164]
The Methods passage (page unavailable) describes a small sample of 29 patients. The Results passage reports greater conspicuity for small lesions with BPL than with OSEM + TOF + PSF, but it does not report whether adding PSF improved conspicuity or detection over reconstruction without PSF. That central comparison is therefore not established by our copy. (LLM, conf=0.78)
Experimental — accuracy not yet measuredPL reconstruction has repeatedly been shown to increase conspicuity and detection rates of pulmonary lesions, even compared to OSEM with PSF and/or TOF.
“PL reconstruction has repeatedly been shown to increase conspicuity and detection rates of pulmonary lesions, even compared to OSEM with PSF and/or TOF [112,113,164,173,174].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [164]
The Results report greater conspicuity for malignant lung lesions under 10 mm with BPL than with OSEM + TOF + PSF, and the Conclusion says BPL improves detection of small, inconspicuous lung tumors. The Results found no significant conspicuity difference for lesions at least 10 mm, and the copy does not report a measured increase in detection rates. Section labels are present, but page numbers are unavailable. (LLM, conf=0.86)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Accuracy of Positron Emission Tomography for Diagnosis of Pulmonary Nodules and Mass Lesions
Gould, M. K., Maclean, C. C., Kuschner, W. G., Rydzak, C. E., & Owens, D. K. (2001) · JAMA · doi:10.1001/jama.285.7.914 · Cited by 1,092 · see citing works
van Tinteren, H., Hoekstra, O. S., Smit, E. F., van den Bergh, J. H. A. M., Schreurs, A. J. M., Stallaert, R. A. L. M., Velthoven, P. C. M. V., Comans, E. F. I., Diepenhorst, F. W., Verboom, P., et al. (2002) · The Lancet · doi:10.1016/s0140-6736(02)08352-6 · Cited by 851 · see citing works
A Systematic Review of the Factors Affecting Accuracy of SUV Measurements
Adams, M. C., Turkington, T. G., Wilson, J. M., & Wong, T. Z. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.10.4923 · Cited by 662 · see citing works
Physical Performance of the new hybrid PET/CT Discovery-690
Bettinardi, V., Presotto, L., Rapisarda, E., Picchio, M., Gianolli, L., & Gilardi, M. C. (2011) · Medical Physics · doi:10.1118/1.3635220 · Cited by 377 · see citing works
Teoh, E. J., McGowan, D. R., Macpherson, R. E., Bradley, K. M., & Gleeson, F. V. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.159301 · Cited by 265 · see citing works
An Assessment of the Impact of Incorporating Time-of-Flight Information into Clinical PET/CT Imaging
Lois, C., Jakoby, B., Long, M. J., Hübner, K. F., Barker, D. W., Casey, M., Conti, M., Panin, V., Kadrmas, D. J., & Townsend, D. W. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.068098 · Cited by 263 · see citing works
Application and Evaluation of a Measured Spatially Variant System Model for PET Image Reconstruction
Alessio, A. M., Stearns, C. W., Tong, S., Ross, S. G., Kohlmyer, S. G., Ganin, A., & Kinahan, P. E. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2040188 · Cited by 214 · see citing works
Varrone, A., Sjöholm, N., Eriksson, L., Gulyás, B. Z., Halldin, C., & Farde, L. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1156-3 · Cited by 204 · see citing works
Boellaard, R., van Lingen, A., & Lammertsma, A. A. (2001) · PubMed · Cited by 195 · see citing works
Tong, S., Alessio, A. M., & Kinahan, P. E. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/5/013 · Cited by 188 · see citing works
Ahn, S., Ross, S. G., Asma, E., Miao, J., Jin, X. H., Cheng, L., Wollenweber, S. D., & Manjeshwar, R. M. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/15/5733 · Cited by 154 · see citing works
Image reconstruction for PET/CT scanners: past achievements and future challenges
Tong, S., Alessio, A. M., & Kinahan, P. E. (2010) · Imaging in Medicine · doi:10.2217/iim.10.49 · Cited by 142 · see citing works
Teoh, E. J., McGowan, D. R., Bradley, K. M., Belcher, E., Black, E., & Gleeson, F. V. (2016) · European Radiology · doi:10.1007/s00330-015-3832-y · Cited by 109 · see citing works
Akamatsu, G., Mitsumoto, K., Taniguchi, T., Tsutsui, Y., Baba, S., & Sasaki, M. (2014) · European Journal of Radiology · doi:10.1016/j.ejrad.2013.09.030 · Cited by 96 · see citing works
Parvizi, N., Franklin, J. M., McGowan, D. R., Teoh, E., Bradley, K. M., & Gleeson, F. V. (2015) · European Journal of Radiology · doi:10.1016/j.ejrad.2015.06.025 · Cited by 91 · see citing works
Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 2.0
Fukukita, H., Suzuki, K., Matsumoto, K., Terauchi, T., Daisaki, H., Ikari, Y., Shimada, N., & Senda, M. (2014) · Annals of Nuclear Medicine · doi:10.1007/s12149-014-0849-2 · Cited by 90 · see citing works
Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 1.0
Fukukita, H., Senda, M., Terauchi, T., Suzuki, K., Daisaki, H., Matsumoto, K., Ikari, Y., & Hayashi, M. (2010) · Annals of Nuclear Medicine · doi:10.1007/s12149-010-0377-7 · Cited by 83 · see citing works
Impact of Time-of-Flight and Point-Spread-Function in SUV Quantification for Oncological PET
Prieto, E., Domínguez‐Prado, I., García‐Velloso, M. J., Peñuelas, I., Richter, J. Á., & Martí-Climent, J. M. (2013) · Clinical Nuclear Medicine · doi:10.1097/rlu.0b013e318279b9df · Cited by 75 · see citing works
Howard, B. A., Morgan, R., Thorpe, M. P., Turkington, T. G., Oldan, J., James, O. G., & Borges-Neto, S. (2017) · Annals of Nuclear Medicine · doi:10.1007/s12149-017-1192-1 · Cited by 70 · see citing works
Teoh, E., McGowan, D. R., Bradley, K. M., Belcher, E., Black, E., Moore, A., Sykes, A., & Gleeson, F. V. (2016) · European Radiology · doi:10.1007/s00330-016-4253-2 · Cited by 55 · see citing works
Molecular Imaging of Pulmonary Nodules
Maffione, A. M., Grassetto, G., Rampin, L., Chondrogiannis, S., Marzola, M. C., Ambrosini, V., & Rubello, D. (2014) · American Journal of Roentgenology · doi:10.2214/ajr.13.11733 · Cited by 21 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Recent Breakthroughs in PET-CT Multimodality Imaging: Innovations and Clinical Impact
Hussain, D., Abbas, N., & Khan, J. (2024) · Bioengineering · doi:10.3390/bioengineering11121213 · Cited by 59 · see citing works
Language Analysis of Speakers with Dementia of the Alzheimer’s Type
Guinn, C. I., & Habash, A. (2012) · National Conference on Artificial Intelligence · Cited by 53 · see citing works
Influences on PET Quantification and Interpretation
Rogasch, J. M. M., Hofheinz, F., van Heek, L., Voltin, C.-A., Boellaard, R., & Kobe, C. (2022) · Diagnostics · doi:10.3390/diagnostics12020451 · Cited by 50 · see citing works
Miwa, K., Yoshii, T., Wagatsuma, K., Nezu, S., Kamitaka, Y., Yamao, T., Kobayashi, R., Fukuda, S., Yakushiji, Y., Miyaji, N., et al. (2023) · EJNMMI Physics · doi:10.1186/s40658-023-00527-w · Cited by 34 · see citing works
Yoshii, T., Miwa, K., Yamaguchi, M., Shimada, K., Wagatsuma, K., Yamao, T., Kamitaka, Y., Hiratsuka, S., Kobayashi, R., Ichikawa, H., et al. (2020) · EJNMMI Physics · doi:10.1186/s40658-020-00325-8 · Cited by 31 · see citing works
Tian, D., Yang, H., Li, Y., Cui, B., & Lu, J. (2022) · EJNMMI Physics · doi:10.1186/s40658-021-00428-w · Cited by 30 · see citing works
Moving the goalposts while scoring―the dilemma posed by new PET technologies
Rogasch, J. M. M., Boellaard, R., Pike, L., Borchmann, P., Johnson, P., Wolf, J., Barrington, S. F., & Kobe, C. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05403-2 · Cited by 20 · see citing works
Xu, L., Cui, C., Li, R., Yang, R., Liu, R., Meng, Q., & Wang, F. (2022) · EJNMMI Research · doi:10.1186/s13550-022-00945-4 · Cited by 12 · see citing works
Liu, L., Liu, H., Xu, S., Zhang, S., Yi, T., Mok, G. S. P., & Chen, Y. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.845806 · Cited by 10 · see citing works
Dwivedi, P., Sawant, V., Vajarkar, V., Vatsa, R., Choudhury, S., Jha, A. K., & Rangarajan, V. (2022) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000001631 · Cited by 6 · see citing works
Tanaka, T., Nakajo, M., Kawakami, H., Motomura, E., Fujisaka, T., Ojima, S., Saigo, Y., & Yoshiura, T. (2022) · EJNMMI Research · doi:10.1186/s13550-022-00933-8 · Cited by 5 · see citing works
Effect of Bayesian penalty likelihood algorithm on 18F-FDG PET/CT image of lymphoma
Wang, Y., Lin, L., Quan, W., Li, J., & Li, W. (2021) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000001516 · Cited by 5 · see citing works
Tatsumi, M., Soeda, F., Kamiya, T., Ueda, J., Katayama, D., Matsunaga, K., Watabe, T., Kato, H., & Tomiyama, N. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.707023 · Cited by 4 · see citing works
Inukai, J. I., Nogami, M., Tachibana, M., Zeng, F., Nishitani, T., Kubo, K., & Murakami, T. (2023) · Diagnostics · doi:10.3390/diagnostics13111871 · Cited by 4 · see citing works
Young, J. R., Mugu, V. K., Johnson, G. B., Ehman, E. C., Packard, A. T., Homb, A. C., Nathan, M. A., Thanarajasingam, G., & Kemp, B. J. (2023) · Medicine · doi:10.1097/md.0000000000032665 · Cited by 3 · see citing works
Fukai, S., Daisaki, H., Shimada, N., Ishiyama, M., Umeda, T., Yamashita, K., Miyaji, N., Takiguchi, T., Kawakami, H., & Terauchi, T. (2022) · Biomedical engineering and physics express · doi:10.1088/2057-1976/aca90d · Cited by 2 · see citing works
Verification of the effect of data-driven brain motion correction on PET imaging
Odagiri, H., Watabe, H., Takanami, K., Akimoto, K., Usui, A., Kawakami, H., Katsuki, A., Uetake, N., Dendo, Y., Tanaka, Y., et al. (2024) · PLoS ONE · doi:10.1371/journal.pone.0301919 · Cited by 2 · see citing works
Sato, H., Odagiri, H., Yamaguchi, N., Kodama, H., Takeuchi, T., Tanaka, Y., Takanami, K., Usui, A., & Kaneta, T. (2025) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.25-1560 · Cited by 1 · see citing works
Hussain, A. A., Forssell-Aronsson, E., Rosholm, T., & Mehrara, E. (2024) · Brazilian Journal of Radiation Sciences · doi:10.15392/2319-0612.2024.2487 · Cited by 1 · see citing works
Digitale SPECT und PET: Klinische Konsequenzen
Rogasch, J. M. M. (2022) · Angewandte Nuklearmedizin · doi:10.1055/a-1715-5305 · Cited by 1 · see citing works
Transverse momentum distribution of secondary $pi$$sup 0$ mesons in air jet
Nishio, A. (1973) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)
PARTIAL VOLUME EFFECT CORRECTION IN PET/CT WITH 11C-METHIONINE FOR THE PATIENTS WITH LUNG LESIONS
Ms, T., & Чипига, Л. А. (2021) · Russian Electronic Journal of Radiology · doi:10.21569/2222-7415-2021-11-3-107-119
Liu, H., Liu, L., Xu, S., Zhonglin, L. U., Mok, G. S. P., Wang, Y., Yi, T., & Chen, Y. (2022) · The Quarterly Journal of Nuclear Medicine and Molecular Imaging · doi:10.23736/s1824-4785.22.03409-4
Digitale SPECT und PET: Klinische Konsequenzen
Rogasch, J. M. M. (2023) · Radiopraxis · doi:10.1055/a-1993-7420
Odagiri, H., Takanami, K., Kaneta, T., Usui, A., Kojima, I., Kodama, H., Saitou, S., Tanaka, Y., Dendo, Y., & Takase, K. (2023) · The Tohoku Journal of Experimental Medicine · doi:10.1620/tjem.2023.j026
Bilateral Low-Accumulation Bladder Artifacts Due to High Radioactivity of Urine on 18 F-FDG PET/CT
Ichikawa, Y., Tomita, Y., Hashizume, K., & Sakuma, H. (2025) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.125.270294
Self-citationXu, L., Cui, C., Li, R., Yang, R., Liu, R., Meng, Q., & Wang, F. (2023) · Figshare · doi:10.6084/m9.figshare.22602265
Wang, B., Cui, B., Ma, J., Yang, H., Yang, Y., Yao, C., Wang, J., Zhang, C., & Lu, J. (2026) · Nuclear Medicine and Molecular Imaging · doi:10.1007/s13139-025-00981-7
Short breath-hold PET imaging in hypermetabolic pulmonary nodules
Yang, Y., Wang, L., Li, J., Zhang, Q., Zeng, L., Li, Y., Wei, X., & Huang, J. (2026) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000002205
- Authors
- Kurita, Y., Ichikawa, Y., Nakanishi, T., Tomita, Y., Hasegawa, D., Murashima, S., Hirano, T., & Sakuma, H.
- Affiliations
- Mie University Hospital (JP)
- Corresponding author
- Ichikawa, Yasutaka
- Venue
- Annals of Nuclear Medicine
- Published
- 2020-02-14
- Volume
- 34
- Issue
- 4
- Pages
- 272-279
- ISSN
- 0914-7187 (ISSN-L)
- 1864-6433
- OpenAlex
- W3006367772
- Cited by
- 29
- References
- 21
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 3 · 2023: 6 · 2022: 9 · 2021: 4 · 2020: 1 · 2012: 1
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- green
- mie-u.repo.nii.ac.jp
- Licence
- Locations
- Annals of Nuclear Medicine (publishedVersion)
- PubMed (publishedVersion)
- Institutional Repositories DataBase (IRDB) (submittedVersion, cc-by-nc-nd)
- Institutional Repositories DataBase (IRDB) (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Keywords
- Bayesian penalized likelihood reconstruction, OSEM, 18F-FDG PET, lung cancer, lesion conspicuity, point spread function correction, signal-to-noise ratio, standardized uptake value, image quality, lung metastasis, primary lung tumor, observer preference, lung nodule detection
- MeSH terms
- Positron Emission Tomography Computed Tomography, Aged, Aged, 80 and over, Algorithms, Bayes Theorem, Female, Humans, Image Processing, Computer-Assisted, Lung Neoplasms, Male, Middle Aged, Neoplasm Staging, Retrospective Studies, Risk Factors, Likelihood Functions, Phantoms, Imaging, Radiopharmaceuticals, Fluorodeoxyglucose F18, Signal-To-Noise Ratio, Multimodal Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review