Isothermal nucleic acid amplification and its uses in modern diagnostic technologies
Open accessThe DOI matches its Crossref record; 129 of the 129 references it cites were found in a registry or an index.
Abstract
Nucleic acids are prominent biomarkers for diagnosing infectious pathogens using nucleic acid amplification techniques (NAATs). PCR, a gold standard technique for amplifying nucleic acids, is widely used in scientific research and diagnosis. Efficient pathogen detection is a key to adequate food safety and hygiene. However, using bulky thermal cyclers and costly laboratory setup limits its uses in developing countries, including India. The isothermal amplification methods are exploited to develop miniaturized sensors against viruses, bacteria, fungi and other pathogenic organisms and have been applied for in situ diagnosis. Isothermal amplification techniques have been found suitable for POC techniques and follow WHO’s ASSURED criteria. LAMP, NASBA, SDA, RCA and RPA are some of the isothermal amplification techniques which are preferable for POC diagnostics. Furthermore, methods such as WGA, CPA, HDA, EXPAR, SMART, SPIA and DAMP were introduced for even more accuracy and robustness. Using recombinant polymerases and other nucleic acid-modifying enzymes has dramatically broadened the detection range of target pathogens under the scanner. The coupling of isothermal amplification methods with advanced technologies such as CRISPR/Cas systems, fluorescence-based chemistries, microfluidics and paper-based sensors has significantly influenced the biosensing and diagnosis field. This review comprehensively analyzed isothermal nucleic acid amplification methods, emphasizing their advantages, disadvantages and limitations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805 · cited 3×
“(II) Cycling amplification of the dumbbellshaped structure results in a stem–loop structure, which then (III) forms a cauliflower-like structure in the elongation and recycling step, resulting in different sizes of DNA amplicons producing a ladder pattern in agarose gel electrophoresis (reproduced with permission by N…”
BackgroundMethodInfluentialMultiplexed and portable nucleic acid detection platform with Cas13, Cas12a, and Csm6
Gootenberg, J. S., Abudayyeh, O. O., Kellner, M. J., Joung, J., Collins, J. J., & Zhang, F. (2018) · Science · doi:10.1126/science.aaq0179 · Cited by 2,638
DNA Detection Using Recombination Proteins
Piepenburg, O., Williams, C. H., Stemple, D. L., & Armes, N. A. (2006) · PLoS Biology · doi:10.1371/journal.pbio.0040204 · Cited by 2,482 · cited 1×
“RPA 103–106 DNA 1 h Recombinase protein, SSB protein, DNA pol 2 37°-42° C Piepenburg et al. (2006)”
BackgroundAccelerated reaction by loop-mediated isothermal amplification using loop primers
Nagamine, K., Hase, T., & Notomi, T. (2002) · Molecular and Cellular Probes · doi:10.1006/mcpr.2002.0415 · Cited by 2,045
Isothermal Amplification of Nucleic Acids
Zhao, Y., Chen, F., Li, Q., Wang, L., & Fan, C. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00428 · Cited by 1,775 · cited 1×
“These IAT use strand displacement activity to carry out NAA without thermocyclers, thus eliminating the temperature cycling step (Zhao et al. 2015).”
MethodNucleic acid sequence-based amplification
Compton, J. (1991) · Nature · doi:10.1038/350091a0 · Cited by 1,344 · cited 2×
“…types of techniques such as the dideoxy method which includes reverse transcriptase and a labeled oligonucleotide primer, enzyme-linked gel assay (ELGA), electrochemiluminescent detection, molecular beacon detection, southern hybridization and fluorescent correlation spectroscopy (Compton 1991).”
BackgroundMethodRolling circle amplification: a versatile tool for chemical biology, materials science and medicine
Ali, M. M., Li, F., Zhang, Z., Zhang, K., Kang, D.-K., Ankrum, J. A., Le, X. C., & Zhao, W. (2014) · Chemical Society Reviews · doi:10.1039/c3cs60439j · Cited by 1,124
Loop-mediated isothermal amplification (LAMP): principle, features, and future prospects
Notomi, T., Mori, Y., Tomita, N., & Kanda, H. (2015) · Journal of Microbiology · doi:10.1007/s12275-015-4656-9 · Cited by 889
Helicase‐dependent isothermal DNA amplification
Vincent, M., Xu, Y., & Kong, H. (2004) · EMBO reports · doi:10.1038/sj.embor.7400200 · Cited by 877
Strand displacement amplification—an isothermal,in vitro DNA amplification technique
Walker, G. T., Fraiser, M. S., Schram, J. L., Little, M. C., Nadeau, J. G., & Malinowski, D. P. (1992) · Nucleic Acids Research · doi:10.1093/nar/20.7.1691 · Cited by 850
Point-of-care nucleic acid testing for infectious diseases
Niemz, A., Ferguson, T. M., & Boyle, D. S. (2011) · Trends in Biotechnology · doi:10.1016/j.tibtech.2011.01.007 · Cited by 838 · cited 1×
“IATs are expanded to detect different targets, including proteins, cells, small molecules and ions (Niemz et al. 2011).”
BackgroundIsothermal nucleic acid amplification technologies for point-of-care diagnostics: a critical review
Craw, P., & Balachandran, W. (2012) · Lab on a Chip · doi:10.1039/c2lc40100b · Cited by 766 · cited 3×
“Various RPA kits have also been commercialized by Twist Dx, Cambridge, UK (Craw and Balachandran 2012).”
BackgroundMethodInfluentialReal-time turbidimetry of LAMP reaction for quantifying template DNA
Mori, Y., Kitao, M., Tomita, N., & Notomi, T. (2004) · Journal of Biochemical and Biophysical Methods · doi:10.1016/j.jbbm.2003.12.005 · Cited by 627 · cited 1×
“2021), magnesium pyrophosphate precipitation (Mori et al. 2004), Cu(OH)2 precipitation (Kanchanaphum 2018 etc.”
BackgroundIsothermal reactions for the amplification of oligonucleotides
Van Ness, J., Van Ness, L. K., & Galas, D. J. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0730811100 · Cited by 542
Isothermal in vitro amplification of DNA by a restriction enzyme/DNA polymerase system.
Walker, G. T., Little, M. C., Nadeau, J. G., & Shank, D. D. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.392 · Cited by 539
Signal amplification of padlock probes by rolling circle replication
Baner, J., Nilsson, M., Mendel-Hartvig, M., & Landegren, U. (1998) · Nucleic Acids Research · doi:10.1093/nar/26.22.5073 · Cited by 539
Nucleic Acid Isothermal Amplification Technologies—A Review
Gill, P., & Ghaemi, A. (2008) · Nucleosides, Nucleotides and Nucleic Acids · doi:10.1080/15257770701845204 · Cited by 534 · cited 1×
“It can produce billion-fold copies of nucleic acid with the help of enzymatic reactions carried out in a thermocycler (Gill and Ghaemi 2008; Prasad et al.”
BackgroundYu, L., Wu, S., Hao, X., Dong, X., Mao, L., Pelechano, V., Chen, W.-H., & Yin, X. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvaa102 · Cited by 477
Zhu, X., Wang, X., Han, L., Chen, T., Wang, L., Li, H., Li, S., He, L., Fu, X., Chen, S., et al. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112437 · Cited by 454
Isothermal amplified detection of DNA and RNA
Yan, L., Zhou, J., Zheng, Y., Gamson, A. S., Roembke, B. T., Nakayama, S., & Sintim, H. O. (2014) · Molecular BioSystems · doi:10.1039/c3mb70304e · Cited by 446
Becherer, L., Borst, N., Bakheit, M., Frischmann, S., Zengerle, R., & von Stetten, F. (2020) · Analytical Methods · doi:10.1039/c9ay02246e · Cited by 429
Kievits, T., van Gemen, B., van Strijp, D., Schukkink, R., Dircks, M., Adriaanse, H., Malek, L., Sooknanan, R., & Lens, P. (1991) · Journal of Virological Methods · doi:10.1016/0166-0934(91)90069-c · Cited by 408
Park, G.-S., Ku, K., Baek, S.-H., Kim, S.-J., Kim, S. I., Kim, B.-T., & Maeng, J.-S. (2020) · The Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2020.03.006 · Cited by 404
Reboud, J., Xu, G., Garrett, A., Adriko, M., Yang, Z., Tukahebwa, E. M., Rowell, C., & Cooper, J. M. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1812296116 · Cited by 351
“Paper Machine” for Molecular Diagnostics
Connelly, J. T., Rolland, J. P., & Whitesides, G. M. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00411 · Cited by 289
Loop-mediated isothermal amplification for the rapid detection of Salmonella
Hara‐Kudo, Y., Yoshino, M., Kojima, T., & Ikedo, M. (2005) · FEMS Microbiology Letters · doi:10.1016/j.femsle.2005.09.032 · Cited by 266
Isothermal Amplification Methods for the Detection of Nucleic Acids in Microfluidic Devices
Zanoli, L., & Spoto, G. (2012) · Biosensors · doi:10.3390/bios3010018 · Cited by 265
Nucleic acid amplification: Alternative methods of polymerase chain reaction
Fakruddin, M., Mannan, K. S. B., Chowdhury, A., Mazumdar, R. M., Hossain, M. N., Islam, S. A., & Chowdhury, M. (2013) · Journal of Pharmacy And Bioallied Sciences · doi:10.4103/0975-7406.120066 · Cited by 245 · cited 2×
“PCR has limitations in resource-compromised settings, such as requiring trained technicians, costly equipment and sample transportation to the laboratory (Fakruddin et al. 2013).”
BackgroundLAMP-on-a-chip: Revising microfluidic platforms for loop-mediated DNA amplification
Zhang, H., Xu, Y., Fohlerova, Z., Chang, H., Iliescu, C., & Neuzil, P. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.01.015 · Cited by 232
Cross Priming Amplification: Mechanism and Optimization for Isothermal DNA Amplification
Xu, G., Hu, L., Zhong, H., Wang, H., Yusa, S.-I., Weiss, T. C., Romaniuk, P. J., Pickerill, S., & You, Q. (2012) · Scientific Reports · doi:10.1038/srep00246 · Cited by 217
Novel Isothermal, Linear Nucleic Acid Amplification Systems for Highly Multiplexed Applications
Kurn, N., Chen, P., Heath, J. D., Kopf-Sill, A., Stephens, K. M., & Wang, S. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.053694 · Cited by 202 · cited 1×
“SPIA 107–109 DNA, RNA 30–90 min DNA pol, RNase H 1 47° C Kurn et al. (2005)”
Exponential Strand-Displacement Amplification for Detection of MicroRNAs
Shi, C., Liu, Q., Ma, C., & Zhong, W. (2014) · Analytical Chemistry · doi:10.1021/ac4038043 · Cited by 193
Digital LAMP in a sample self-digitization (SD) chip
Gansen, A., Herrick, A. M., Dimov, I. K., Lee, L. P., & Chiu, D. T. (2012) · Lab on a Chip · doi:10.1039/c2lc21247a · Cited by 187
Liu, C., Geva, E., Mauk, M. G., Qiu, X., Abrams, W. R., Malamud, D., Curtis, K. A., Owen, S. M., & Bau, H. H. (2011) · The Analyst · doi:10.1039/c1an00007a · Cited by 187 · cited 3×
“LFD-LAMP SVCV Lateral flow dipstick-hybrid probe-labeled fluorescein amidite 860 fg/μL Liu et al. (2018)”
InfluentialSayad, A. A., Ibrahim, F., Uddin, S. M., Cho, J., Madou, M. J., & Thong, K. L. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.08.060 · Cited by 187
Oh, S. J., Park, B. H., Jung, J. H., Choi, G., Lee, D. C., Kim, D. H., & Seo, T. S. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.052 · Cited by 182
Nzelu, C. O., Kato, H., & Peters, N. C. (2019) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0007698 · Cited by 174
Wang, Y., Wang, Y., Ma, A., Li, D.-X., Luo, L., Liu, D., Jin, D., Liu, K., & Ye, C. (2015) · Scientific Reports · doi:10.1038/srep11902 · Cited by 168
Sun, W., Qin, P., Gao, H., Li, G., & Jiao, K. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.10.011 · Cited by 165
Ohtsuka, K., Yanagawa, K., Takatori, K., & Hara‐Kudo, Y. (2005) · Applied and Environmental Microbiology · doi:10.1128/aem.71.11.6730-6735.2005 · Cited by 163 · cited 1×
“Since then, many LAMP assays have been developed and employed with different primer designs for the detection of non-typhoidal Salmonella in various applications as well as the detection of other different pathogens by designing specific primers (Table 4) (Ohtsuka et al. 2005; Zhong and Zhao 2017).”
MethodPaper‐Origami‐Based Multiplexed Malaria Diagnostics from Whole Blood
Xu, G., Nolder, D., Reboud, J., Oguike, M. C., van Schalkwyk, D. A., Sutherland, C. J., & Cooper, J. M. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201606060 · Cited by 160
Tian, B., Gao, F., Fock, J., Dufva, M., & Hansen, M. F. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112356 · Cited by 159
Fang, X., Chen, H., Yu, S., Jiang, X., & Kong, J. (2010) · Analytical Chemistry · doi:10.1021/ac102858j · Cited by 155
Yang, Q., Domesle, K. J., & Ge, B. (2018) · Foodborne Pathogens and Disease · doi:10.1089/fpd.2018.2445 · Cited by 143
Ge, J., Hu, Y. F., Deng, R., Li, Z., Zhang, K., Shi, M., Yang, D., Cai, R., & Tan, W. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03405 · Cited by 139
Nucleic acid sequence-based amplification (NASBA) for the identification of mycobacteria
Gabrielle, M. E., van der, V., Schukkink, R. A. F., van Gemen, B., y Schepers, & y Klatser (1993) · Journal of General Microbiology · doi:10.1099/00221287-139-10-2423 · Cited by 132
Digital Loop-Mediated Isothermal Amplification on a Commercial Membrane
Lin, X., Huang, X. H., Urmann, K., Xie, X., & Hoffmann, M. R. (2019) · ACS Sensors · doi:10.1021/acssensors.8b01419 · Cited by 122 · cited 3×
“Liu et al. in (2018) compared three assays of LAMP technology for the detection of the SVCV virus. The three assays (SYBR dye, lateral flow dipstick and agarose gel electrophoresis) were used to conclude which assay was better. The result concluded that the LFD-LAMP assay could be employed for the detection of SVCV vi…”
MethodInfluentialLee, S. H., Baek, Y. H., Kim, Y.-H., Choi, Y. K., Song, M., & Ahn, J. (2017) · Frontiers in Microbiology · doi:10.3389/fmicb.2016.02166 · Cited by 121
Quyen, T. L., Ngo, T. A., Bang, D. D., Madsen, M., & Wolff, A. (2019) · Frontiers in Microbiology · doi:10.3389/fmicb.2019.02234 · Cited by 119
Nucleic Acid Sequence-Based Amplification of Aspergillus RNA in Blood Samples
Loeffler, J., Hebart, H. F., Cox, P., Flues, N., Schumacher, U., & Einsele, H. (2001) · Journal of Clinical Microbiology · doi:10.1128/jcm.39.4.1626-1629.2001 · Cited by 118
Loop-mediated isothermal amplification-based microfluidic chip for pathogen detection
Shang, Y., Sun, J., Ye, Y., Zhang, J., Zhang, Y., & Sun, X. (2018) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2018.1518897 · Cited by 115
Thermostable Bst DNA polymerase I lacks a 3′ → 5′ proofreading exonuclease activity
Aliotta, J. M., Pelletier, J. J., Ware, J., et al. (1996) · Genetic Analysis Biomolecular Engineering · doi:10.1016/s1050-3862(96)80005-2 · Cited by 114
Kurosaki, Y., Magassouba, N., Oloniniyi, O. K., Chérif, M. S., Sakabe, S., Takada, A., Hirayama, K., & Yasuda, J. (2016) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0004472 · Cited by 113 · cited 1×
“9 Zaire ebolavirus 15–20 min Real-time instrument OptiGene, UK Kurosaki et al. (2016)”
Fowler, V. L., Armson, B., Gonzáles, J. L., Wise, E. L., Howson, E. L. A., Vincent‐Mistiaen, Z. I., Fouch, S., Maltby, C. J., Grippon, S., Munro, S., et al. (2020) · Journal of Infection · doi:10.1016/j.jinf.2020.10.039 · Cited by 110
Wang, C., Lien, K.-Y., Wang, T., Chen, T.-Y., & Lee, G. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.08.083 · Cited by 108
Multiple displacement amplification to create a long-lasting source of DNA for genetic studies
Lovmar, L., & Syvänen, A. (2006) · Human Mutation · doi:10.1002/humu.20341 · Cited by 101 · cited 1×
“Multiple displacement amplification technique requires multiple primers for strand displacement replication of nucleic acids (Lovmar and Syvanen 2006).”
Droplet and Microchamber‐Based Digital Loop‐Mediated Isothermal Amplification (dLAMP)
Yuan, H., Chao, Y., & Shum, H. C. (2020) · Small · doi:10.1002/smll.201904469 · Cited by 99
Oriero, E. C., Jacobs, J. A., Geertruyden, J. V., Nwakanma, D. C., & D’Alessandro, U. (2014) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dku343 · Cited by 97 · cited 1×
“These techniques are fast, reliable and performed in a thermostat water bath/dry bath with minimum expenditure (Oriero et al. 2015).”
BackgroundVisual and modular detection of pathogen nucleic acids with enzyme–DNA molecular complexes
Ho, N. R. Y., Lim, G. S., Sundah, N. R., Lim, D. G. S., Loh, T. P., & Shao, H. (2018) · Nature Communications · doi:10.1038/s41467-018-05733-0 · Cited by 89
Colorimetric LAMP microfluidic chip for detecting three allergens: peanut, sesame and soybean
Yuan, D., Kong, J., Li, X., Fang, X., & Chen, Q. (2018) · Scientific Reports · doi:10.1038/s41598-018-26982-5 · Cited by 88
Mei, X., Zhai, X., Lei, C., Ye, X., Kang, Z.-Z., Wu, X., Xiang, R., Wang, Y., & Wang, H. (2019) · Food Control · doi:10.1016/j.foodcont.2019.04.014 · Cited by 87
Jang, W. S., Lim, D. H., Yoon, J., Kim, A., Lim, M., Nam, J., Yanagihara, R. T., Ryu, S.-W., Jung, B. K., Ryoo, N. H., et al. (2021) · PLoS ONE · doi:10.1371/journal.pone.0248042 · Cited by 83 · cited 1×
“Other techniques used for detection include multiplex analysis (Jang et al. 2021), droplet digital LAMP (Fan et al.”
MethodDuan, Y., Ge, C., Zhang, X., Wang, J., & Zhou, M. (2013) · Australasian Plant Pathology · doi:10.1007/s13313-013-0239-6 · Cited by 82
Isothermal Amplification Technologies for the Detection of Foodborne Pathogens
Zhong, J., & Zhao, X. (2018) · Food Analytical Methods · doi:10.1007/s12161-018-1177-2 · Cited by 81 · cited 5×
“Since then, many LAMP assays have been developed and employed with different primer designs for the detection of non-typhoidal Salmonella in various applications as well as the detection of other different pathogens by designing specific primers (Table 4) (Ohtsuka et al. 2005; Zhong and Zhao 2017).”
MethodInfluentialPang, B., Fu, K., Liu, Y., Ding, X., Hu, J., Wu, W., Xu, K., Song, X., Wang, J., Mu, Y., et al. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.07.024 · Cited by 81
Martzy, R., Kolm, C., Krska, R., Mach, R. L., Farnleitner, A. H., & Reischer, G. H. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1553-1 · Cited by 78 · cited 2×
“Many molecular diagnostic methods have drastically evolved to sense nucleic acids in past decades (Martzy et al. 2019).”
BackgroundComparison of whole genome amplification techniques for human single cell exome sequencing
Borgström, E., Paterlini, M., Mold, J. E., Frisen, J., & Lundeberg, J. (2017) · PLOS ONE · doi:10.1371/journal.pone.0171566 · Cited by 77
Diego, J. G.-B., Fernández‐Soto, P., Crego-Vicente, B., Alonso-Castrillejo, S., Febrer‐Sendra, B., Gómez-Sánchez, A., Vicente, B., López‐Abán, J., & Muro, A. (2019) · Scientific Reports · doi:10.1038/s41598-019-51342-2 · Cited by 77
Deleye, L., Tilleman, L., Plaetsen, A. V., Cornelis, S., Deforce, D. L. D., & Nieuwerburgh, F. V. (2017) · Scientific Reports · doi:10.1038/s41598-017-03711-y · Cited by 76
Rapid Detection of Candida auris Based on Loop-Mediated Isothermal Amplification (LAMP)
Yamamoto, M., Alshahni, M. M., Tamura, T., Satoh, K., Iguchi, S., Kikuchi, K., Mimaki, M., & Makimura, K. (2018) · Journal of Clinical Microbiology · doi:10.1128/jcm.00591-18 · Cited by 72
Quantitative analysis of zeptomole microRNAs based on isothermal ramification amplification
Yao, B., Li, J., Huang, H., Sun, C., Wang, Z., Fan, Y., Chang, Q., Li, S., & Xi, J. (2009) · RNA · doi:10.1261/rna.1555209 · Cited by 72
Hellyer, T. J., DesJardin, L. E., Teixeira, L. D. O., Perkins, M. D., Cave, M. D., & Eisenach, K. D. (1999) · Journal of Clinical Microbiology · doi:10.1128/jcm.37.3.518-523.1999 · Cited by 71
Mathematical model to reduce loop mediated isothermal amplification (LAMP) false‐positive diagnosis
Schneider, L., Blakely, H., & Tripathi, A. (2019) · Electrophoresis · doi:10.1002/elps.201900167 · Cited by 67
Huang, X. H., Lin, X., Urmann, K., Li, L., Xie, X., Jiang, S. C., & Hoffmann, M. R. (2018) · Environmental Science & Technology · doi:10.1021/acs.est.8b00241 · Cited by 65
Detection of enterovirus RNA in cerebrospinal fluid (CSF) using NucliSens EasyQ Enterovirus assay
Capaul, S., & Gorgievski-Hrisoho, M. (2004) · Journal of Clinical Virology · doi:10.1016/j.jcv.2004.08.006 · Cited by 62 · cited 1×
“0 NASBA 95/100 HIV 1 h Automated assay Biomeriux Capaul and Gorgievski-Hrisoho (2005)”
Cui, Y., Feng, X., Wang, Y., Pan, H.-Y., Pan, H., & Kong, D. (2018) · Chemical Science · doi:10.1039/c8sc05102j · Cited by 60
Zhang, J., Cao, J., Zhu, M., Xu, M., & Shi, F. (2019) · World Journal of Microbiology and Biotechnology · doi:10.1007/s11274-019-2601-5 · Cited by 58
Chen, C., Zhao, Q., Jianwei, G., Li, Y., & Chen, Q. (2017) · Current Microbiology · doi:10.1007/s00284-017-1274-2 · Cited by 56
Kim, S. H., Kim, J. H., Kim, S., Park, J. S., Cha, B. S., Lee, E. S., Han, J., Shin, J., Jang, Y., & Park, K. S. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.339781 · Cited by 56
Selection of fluorescent DNA dyes for real-time LAMP with portable and simple optics
Seyrig, G., Stedtfeld, R. D., Tourlousse, D. M., Ahmad, F. J., Towery, K., Cupples, A. M., Tiedje, J. M., & Hashsham, S. A. (2015) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2015.11.004 · Cited by 54
Ultrasensitive loop mediated isothermal amplification (US-LAMP) to detect malaria for elimination
Mohon, A. N., Getie, S., Jahan, N., Alam, M. S., & Pillai, D. R. (2019) · Malaria Journal · doi:10.1186/s12936-019-2979-4 · Cited by 53 · cited 1×
“US-LAMP Plasmodium falciparum Fluorescent dyes 50 parasites/mL Mohon et al. (2019)”
Tong, Y., Lemieux, B., & Kong, H. (2011) · BMC Biotechnology · doi:10.1186/1472-6750-11-50 · Cited by 52
Mashooq, M., Kumar, D., Niranjan, A. K., Agarwal, R. K., & Rathore, R. (2016) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2016.04.014 · Cited by 50
Primase-based whole genome amplification
Li, Y., Kim, H., Zheng, C. Y., Chow, W. H. A., Lim, J., Keenan, B. T., Pan, X., Lemieux, B., & Kong, H. (2008) · Nucleic Acids Research · doi:10.1093/nar/gkn377 · Cited by 48 · cited 1×
“WGA 103–107 DNA 1 h T7 gp4 primase, Phi 29 DNA pol – 37° C Li et al. (2008)”
Digital Rolling Circle Amplification–Based Detection of Ebola and Other Tropical Viruses
Ciftci, S., Neumann, F., Abdurahman, S., Appelberg, K. S., Mirazimi, A., Nilsson, M. F., & Madaboosi, N. (2019) · Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2019.10.014 · Cited by 46
Teixeira, A., Paris, J. L., Roumani, F., Diéguez, L., Prado, M., Espiña, B., Abalde‐Cela, S., Garrido‐Maestu, A., & Rodríguez‐Lorenzo, L. (2020) · Materials · doi:10.3390/ma13081934 · Cited by 46
Saetiew, C., Limpaiboon, T., Jearanaikoon, P., Daduang, S., Pientong, C., Kerdsin, A., & Daduang, J. (2011) · Journal of Virological Methods · doi:10.1016/j.jviromet.2011.08.007 · Cited by 45 · cited 1×
“For HPV 16 and 18 subtypes, they used already established primers (Saetiew et al. 2011).”
MethodUse of Signal-Mediated Amplification of RNA Technology (SMART) to Detect Marine Cyanophage DNA
Hall, M. J., Wharam, S. D., Weston, A., Cardy, D. L. N., & Wilson, W. H. (2002) · BioTechniques · doi:10.2144/02323rr02 · Cited by 45
Gaydos, C. A., Schwebke, J. R., Dombrowski, J., Marrazzo, J. M., Coleman, J. S., Silver, B., Barnes, M., Crane, L., & Fine, P. M. (2017) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2017.1282823 · Cited by 44
Ding, X., Wu, W., Zhu, Q., Zhang, T., Jin, W., & Mu, Y. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02112 · Cited by 44
Loop-mediated isothermal amplification (LAMP) shield for Arduino DNA detection
Velders, A. H., Schoen, C. D., & Saggiomo, V. (2018) · BMC Research Notes · doi:10.1186/s13104-018-3197-9 · Cited by 43
He, Z., Su, Y.-T., Li, S., Long, P., Zhang, P., & Chen, Z. (2019) · Frontiers in Microbiology · doi:10.3389/fmicb.2019.01523 · Cited by 42
Ding, X., Xu, Z., Yin, K., Sfeir, M. M., & Liu, C. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02582 · Cited by 41
RNA detection with high specificity and sensitivity using nested fluorogenic Mango NASBA
Abdolahzadeh, A., Dolgosheina, E. V., & Unrau, P. J. (2019) · RNA · doi:10.1261/rna.072629.119 · Cited by 41
Saad, A. A., Ahmed, N. G., Osman, O. S., Al‐Basheer, A. A., Hamad, A., Deborggraeve, S., Büscher, P., Schoone, G. J., Schallig, H. D. F. H., Laurent, T., et al. (2010) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0000776 · Cited by 41
Wang, Y., Wang, Y., Jiao, W., Li, J., Quan, S., Sun, L., Wang, Y., Qi, X., Wang, X., & Shen, A. (2019) · AMB Express · doi:10.1186/s13568-019-0921-3 · Cited by 38
Akduman, D., Ehret, J. M., Messina, K., Ragsdale, S., & Judson, F. N. (2002) · Journal of Clinical Microbiology · doi:10.1128/jcm.40.1.281-283.2002 · Cited by 38
Hu, J., Wang, Y., Su, H., Ding, H., Sun, X., Gao, H., Geng, Y., & Wang, Z. (2019) · Molecular and Cellular Probes · doi:10.1016/j.mcp.2019.101501 · Cited by 38
Ordonez, N., Salacinas, M., Mendes, O., Seidl, M. F., Meijer, H. J. G., Schoen, C. D., & Kema, G. H. J. (2019) · Plant Pathology · doi:10.1111/ppa.13093 · Cited by 38
Rohatensky, M. G., Livingstone, D. M., Mintchev, P., Barnes, H. K., Nakoneshny, S. C., Demetrick, D. J., Dort, J. C., & van Marle, G. (2018) · BMC Cancer · doi:10.1186/s12885-018-4087-1 · Cited by 37
Priya, G. B., Agrawal, R. K., Milton, A. A. P., Mishra, M., Mendiratta, S. K., Luke, A., Inbaraj, S., Singh, B. R., Kumar, D., Kumar, G. R., et al. (2020) · LWT · doi:10.1016/j.lwt.2020.109262 · Cited by 37
Wang, T., Peng, Q., Guo, B., Zhang, D., Zhao, M., Que, H., Wu, H., & Yan, Y. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111954 · Cited by 36
Takano, C., Seki, M., Kim, D. W., Gardner, H., McLaughlin, R. E., Kilgore, P. E., Kumasaka, K., & Hayakawa, S. (2019) · Frontiers in Microbiology · doi:10.3389/fmicb.2019.00025 · Cited by 35
Yang, X., Al-Attala, M. N., Zhang, Y., Zhang, A., Zang, H.-Y., Gu, C., Gao, T., Chen, Y., Al-Attala, M. N., Ali, F., et al. (2018) · Plant Disease · doi:10.1094/pdis-01-18-0065-re · Cited by 32
Panek, J., & Frąc, M. (2019) · Scientific Reports · doi:10.1038/s41598-019-42275-x · Cited by 30 · cited 2×
“Panek and Frąc (2019) designed a LAMP technique for detection of Talaromyces flavus, a soilborne fungus, which is responsible for contamination of fruits.”
MethodLee, J. W., Nguyen, V. D., & Seo, T. S. (2019) · BioChip Journal · doi:10.1007/s13206-019-3310-8 · Cited by 27
Quantification of Colorimetric Loop-mediated Isothermal Amplification Process
Nguyen, V. D., Nguyen, V. H., & Seo, T. S. (2019) · BioChip Journal · doi:10.1007/s13206-019-3206-7 · Cited by 27
Liu, M., Li, C., Luo, X., Ma, F., & Zhang, C. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04382 · Cited by 26
Feng, S., Mao, S., Dou, J., Li, W., Li, H., & Lin, J. (2019) · Chemical Science · doi:10.1039/c9sc02974e · Cited by 26
Zheng, F., Su-fang, L., Wang, S., Feng, T., Jiang, Z., & Pan, J. (2020) · Analytical Biochemistry · doi:10.1016/j.ab.2020.113672 · Cited by 26
Marciniak, J. Y., Kummel, A. C., Esener, S. C., Heller, M. J., & Messmer, B. T. (2008) · BioTechniques · doi:10.2144/000112910 · Cited by 26
de Avelar, D. M., Carvalho, D. M., & Rabello, A. (2019) · BioMed Research International · doi:10.1155/2019/8240784 · Cited by 25 · cited 6×
“Avelar et al. (2019) was able to develop a novel LAMP technology for detection of visceral leishmaniasis, a tropical disease. They targeted the K-26 antigen-coding gene of the L. donovani complex. They collected 219 blood samples which included VL and non-VL samples, which are tested with parasitological and serologic…”
BackgroundMethodInfluentialElectric LAMP: Virtual Loop-Mediated Isothermal AMPlification
Salinas, N. R., & Little, D. P. (2012) · ISRN Bioinformatics · doi:10.5402/2012/696758 · Cited by 24 · cited 1×
“Manuscript for digitization of LAMP for easy prediction of target sequence amplification – Salinas and Little (2012)”
MethodRapid on-site detection of Acidovorax citrulli by cross-priming amplification
Zhang, J., Tian, Q., Zhu, S., Zhao, W., & Liu, F. (2012) · Molecular and Cellular Probes · doi:10.1016/j.mcp.2012.03.010 · Cited by 24 · cited 6×
“LAMP technique is currently used in different ways for the detection of LAMP amplicons such as gel electrophoresis, naked eye detection, turbidimetric, colorimetric, bioluminescence, fluorescence, electrochemical sensors/ chips, ELISA and lateral flow dipstick (LFD) (Zhong and Zhao 2017). Shang et al. in (2018) classi…”
MethodInfluentialWang, L., Chen, G., Zhang, C., Wang, Y., & Sun, R. X. (2019) · Environmental Science and Pollution Research · doi:10.1007/s11356-019-06889-y · Cited by 22
Deng, Y., Liu, Y., Jiang, Z., Wang, J., Zhang, Q., Qian, Y., Yuan, Y., Zhou, X., Fan, G., & Li, Y. (2019) · BioScience Trends · doi:10.5582/bst.2019.01267 · Cited by 21
Sudarsan, S., Prabhu, A., Prasad, D., & Mani, N. K. (2023) · The Analyst · doi:10.1039/d3an00102d · Cited by 19
Self-citationNorén, T., Unemo, M., Magnusson, C., Eiserman, M., & Matussek, A. (2013) · Apmis · doi:10.1111/apm.12121 · Cited by 19
Gong, L., Tang, F., Liu, E., Liu, X., Xu, H., Wang, Y., Song, Y., & Liang, J. (2021) · PLoS ONE · doi:10.1371/journal.pone.0249582 · Cited by 18
A mechanism for ramified rolling circle amplification
Beals, T. P., Smith, J. H., Nietupski, R. M., & Lane, D. J. (2010) · BMC Molecular Biology · doi:10.1186/1471-2199-11-94 · Cited by 18
Rapid Detection of Bacillus cereus Using Cross-Priming Amplification
Zhang, J., Di, B., Shan, H., Liu, J., Zhou, Y. K., Chen, H., Hu, L., Wu, X., & Bai, Z. (2019) · Journal of Food Protection · doi:10.4315/0362-028x.jfp-19-156 · Cited by 16
Wang, X., Liu, W., Yin, B., Sang, Y., Liu, Z., Dai, Y., Duan, X., Zhang, G., Ding, S., & Tao, Z. (2017) · Microchimica Acta · doi:10.1007/s00604-017-2158-7 · Cited by 14
Isothermal Amplification of Rabies Virus Gene
Sugiyama, M., Ito, N., & Minamoto, N. (2003) · Journal of Veterinary Medical Science · doi:10.1292/jvms.65.1063 · Cited by 14
Yang, D., Guo, Z., Wang, J., Jin, Y., Mei, Q., & Miao, P. (2019) · Particle & Particle Systems Characterization · doi:10.1002/ppsc.201900273 · Cited by 12
Self-Assembled Inkjet Printer for Droplet Digital Loop-Mediated Isothermal Amplification
Fan, Z., Sun, Y., & Lin, J. (2022) · Chemosensors · doi:10.3390/chemosensors10070247 · Cited by 11
Yang, Q., Zhang, Y., Li, C., Zhao, Y., Ma, X., Zhang, W., & Zhang, S. (2018) · Food Analytical Methods · doi:10.1007/s12161-018-1294-y · Cited by 10
Fluorescent S1 nuclease assay utilizing exponential strand displacement amplification
Lee, C. Y., Kim, H., Kim, H. Y., Park, K. S., & Park, H. G. (2019) · The Analyst · doi:10.1039/c9an00300b · Cited by 7
Rapid detection of Pseudomonas aeruginosa by cross priming amplification
Xiang, Y., Yan, L., Zheng, X., Li, L.-Z., Liu, P., & Cao, W. (2020) · Journal of Integrative Agriculture · doi:10.1016/s2095-3119(20)63187-2 · Cited by 6
Habiburrahman, M., Ariq, H., & Handayani, D. (2021) · The Journal of Infection in Developing Countries · doi:10.3855/jidc.15188 · Cited by 5
Cited by
Laxminarayan, R., Impalli, I., Rangarajan, R., Cohn, J., Ramjeet, K., Trainor, B. W., Strathdee, S., Sumpradit, N., Berman, D., Wertheim, H., et al. (2024) · The Lancet · doi:10.1016/s0140-6736(24)00878-x · Cited by 111
Metadata
- Authors
- Srivastava, P., & Prasad, D.
- Venue
- 3 Biotech
- Published
- 2023-05-18
- Volume
- 13
- Issue
- 6
- Pages
- 200-200
- ISSN
- 2190-572X (ISSN-L)
- 2190-5738
- OpenAlex
- W4377028779
- Cited by
- 222
- References
- 129
- FWCI
- 16.28
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.