Muscle Oximetry in Sports Science: An Updated Systematic Review
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Background: In the last 5 years since our last systematic review, a significant number of articles have been published on the technical aspects of muscle near-infrared spectroscopy (NIRS), the interpretation of the signals and the benefits of using the NIRS technique to measure the physiological status of muscles and to determine the workload of working muscles. Objectives: Considering the consistent number of studies on the application of muscle oximetry in sports science published over the last 5 years, the objectives of this updated systematic review were to highlight the applications of muscle oximetry in the assessment of skeletal muscle oxidative performance in sports activities and to emphasize how this technology has been applied to exercise and training over the last 5 years. In addition, some recent instrumental developments will be briefly summarized. Methods: Preferred Reporting Items for Systematic Reviews guidelines were followed in a systematic fashion to search, appraise and synthesize existing literature on this topic. Electronic databases such as Scopus, MEDLINE/PubMed and SPORTDiscus were searched from March 2017 up to March 2023. Potential inclusions were screened against eligibility criteria relating to recreationally trained to elite athletes, with or without training programmes, who must have assessed physiological variables monitored by commercial oximeters or NIRS instrumentation. Results: Of the identified records, 191 studies regrouping 3435 participants, met the eligibility criteria. This systematic review highlighted a number of key findings in 37 domains of sport activities. Overall, NIRS information can be used as a meaningful marker of skeletal muscle oxidative capacity and can become one of the primary monitoring tools in practice in conjunction with, or in comparison with, heart rate or mechanical power indices in diverse exercise contexts and across different types of training and interventions. Conclusions: Although the feasibility and success of the use of muscle oximetry in sports science is well documented, there is still a need for further instrumental development to overcome current instrumental limitations. Longitudinal studies are urgently needed to strengthen the benefits of using muscle oximetry in sports science.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The PRISMA 2020 statement: An updated guideline for reporting systematic reviews
Page, M. J., McKenzie, J. E., Bossuyt, P. M., Boutron, I., Hoffmann, T. C., Mulrow, C. D., Shamseer, L., Tetzlaff, J. M., Akl, E. A., Brennan, S. E., et al. (2021) · BMJ · doi:10.1136/bmj.n71 · Cited by 108,283
Understanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470 · cited 4×
“…(NIRS), is able to provide, non-invasively, information about the changes in oxygenation of haemoglobin (Hb), present primarily in smal vessels ( 1 mm in diameter) such as the capillary, arteriolar and venular bed, and myo-globin (Mb), a cytoplasmic protein of the striated muscles [1–3].”
BackgroundMethodInfluentialFerrari, M., Muthalib, M., & Quaresima, V. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0230 · Cited by 450
Self-citationThe anaerobic threshold: 50+ years of controversy
Poole, D. C., Rossiter, H. B., Brooks, G. A., & Gladden, L. B. (2021) · The Journal of Physiology · doi:10.1113/jp279963 · Cited by 312 · cited 2×
“This refers to the highest exercise intensity at which a plateau in the muscle oxygen saturation rate (zero-slope) is reached [224].”
BackgroundPage, M. J., McKenzie, J. E., & Higgins, J. P. T. (2018) · BMJ Open · doi:10.1136/bmjopen-2017-019703 · Cited by 278
Muscle Oximetry in Sports Science: A Systematic Review
Perrey, S., & Ferrari, M. (2018) · Sports Medicine · doi:10.1007/s40279-017-0820-1 · Cited by 220
Self-citationValidity and reliability of the Moxy oxygen monitor during incremental cycling exercise
Crum, E. M., O'Connor, W. J., Van Loo, L., Valckx, M., & Stannard, S. R. (2017) · European Journal of Sport Science · doi:10.1080/17461391.2017.1330899 · Cited by 206 · cited 1×
“Currently, wearable NIRS measurements using either PortaMon or Moxy, demonstrated moderate-to-excellent relative reliability scores, and CV as low as 10% for SmO 2 [217, 218].”
MethodMcManus, C. J., Collison, J., & Cooper, C. E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.1.015007 · Cited by 205 · cited 1×
“A study comparing SmO 2 measurements from Moxy and PortaMon devices provided physiologically credible SmO 2 measures at rest and during exercise [206].”
ResultFeldmann, A., Schmitz, R. W., & Erlacher, D. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.11.115001 · Cited by 203 · cited 1×
“The reliability and validity of these oximeters have been reported [203–205].”
BackgroundRyan, T. E., Southern, W. M., Reynolds, M. A., & McCully, K. K. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00835.2013 · Cited by 192
Farzam, P., Starkweather, Z., & Franceschini, M. A. (2018) · Physiological Reports · doi:10.14814/phy2.13664 · Cited by 107
Craig, J. C., Broxterman, R. M., Wilcox, S. L., Chen, C., & Barstow, T. J. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00207.2017 · Cited by 95 · cited 1×
“Adipose tissue greatly attenuates the signals; correcting for its attenuation has been suggested on the basis of the strength of the relationship between NIRS-derived measurements and the adipose tissue thickness [211, 212].”
BackgroundSouthern, W. M., Ryan, T. E., Reynolds, M. A., & McCully, K. (2014) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2013-0347 · Cited by 80
Boone, J., Barstow, T. J., Celie, B., Prieur, F., & Bourgois, J. (2016) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2015-0261 · Cited by 70
Kirby, B. S., Clark, D. A., Bradley, E. M., & Wilkins, B. W. (2021) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00058.2021 · Cited by 66 · cited 1×
“It is worth noting that critical metabolic rate, determined by the balance between muscle O 2 supply and metabolic demand in quadriceps and forearm muscle sites, predicts the time of exhaustion during continuous and intermittent exercise [227].”
BackgroundBorn, D.-P., Stöggl, T., Swarén, M., & Björklund, G. (2017) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2016-0101 · Cited by 59
Sendra-Pérez, C., Sanchez-Jimenez, J. L., Marzano-Felisatti, J. M., Encarnación-Martínez, A., Salvador-Palmer, R., & Priego-Quesada, J. I. (2023) · Scientific Reports · doi:10.1038/s41598-023-39651-z · Cited by 52
Yogev, A., Arnold, J., Nelson, H., Clarke, D. C., Guenette, J. A., Sporer, B. C., & Koehle, M. S. (2023) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2023.1143393 · Cited by 49 · cited 1×
“…2 saturation measured by wearable NIRS was found to have similar reliability to O 2 uptake and heart rate, across exercise intensities, suggesting that it is suitable for daily use as a non-invasive method of monitoring internal burden alongside other regular systemic physiological variables [216].”
MethodGelabert-Rebato, M., Wiebe, J. C., Martin-Rincon, M., Galvan-Alvarez, V., Curtelin, D., Perez-Valera, M., Juan Habib, J., Pérez-López, A., Vega, T., Morales-Alamo, D., et al. (2019) · Nutrients · doi:10.3390/nu11020344 · Cited by 49 · cited 2×
“Cherry polyphenols [67] and mango leaf extract rich in mangiferin [53–55] may be useful nutritional aids for improving muscular endurance performance.”
BackgroundIannetta, D., Qahtani, A., Mattioni Maturana, F., & Murias, J. M. (2017) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2017.01.237 · Cited by 48
Jones, S., D'Silva, A., Bhuva, A., Lloyd, G., Manisty, C., Moon, J. C., Sharma, S., & Hughes, A. D. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.01018 · Cited by 47
Muscle Oxygen Saturation Breakpoints Reflect Ventilatory Thresholds in Both Cycling and Running
Feldmann, A., Ammann, L., Gächter, F., Zibung, M., & Erlacher, D. (2022) · Journal of Human Kinetics · doi:10.2478/hukin-2022-0054 · Cited by 41
Caen, K., Bourgois, J. G., Stassijns, E., & Boone, J. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-022-04942-2 · Cited by 41
Reliability of NIRS portable device for measuring intercostal muscles oxygenation during exercise
Contreras-Briceño, F., Espinosa-Ramirez, M., Hevia, G., Llambias, D., Carrasco, M., Cerda, F., López-Fuenzalida, A., García, P., Gabrielli, L., & Viscor, G. (2019) · Journal of Sports Sciences · doi:10.1080/02640414.2019.1653422 · Cited by 40
Tuesta, M., Yáñez-Sepúlveda, R., Verdugo-Marchese, H., Mateluna, C., & Alvear-Ordenes, I. (2022) · Biology · doi:10.3390/biology11071073 · Cited by 37
Yogev, A., Arnold, J., Clarke, D., Guenette, J. A., Sporer, B. C., & Koehle, M. S. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.818733 · Cited by 35 · cited 3×
“Deoxygenation breakpoint measurements [222, 228] may allow better categorization of the training stimulus into zones of exercise intensity (e.g. percentage of one-repetition maximum for the load prescription or percentage of maximum voluntary contraction) for specific muscle groups in…”
BackgroundGelabert-Rebato, M., Wiebe, J. C., Martin-Rincon, M., Gericke, N., Perez-Valera, M., Curtelin, D., Galvan-Alvarez, V., Lopez-Rios, L., Morales-Alamo, D., & Calbet, J. A. L. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00740 · Cited by 33
Determination of Second Lactate Threshold Using Near-infrared Spectroscopy in Elite Cyclists
Salas-Montoro, J.-A., Mateo-March, M., Sánchez-Muñoz, C., & Zabala, M. (2022) · International Journal of Sports Medicine · doi:10.1055/a-1738-0252 · Cited by 27
Using a Portable Near-infrared Spectroscopy Device to Estimate The Second Ventilatory Threshold
Rodrigo-Carranza, V., González-Mohíno, F., Turner, A. P., Rodriguez-Barbero, S., & González-Ravé, J. M. (2021) · International Journal of Sports Medicine · doi:10.1055/a-1343-2127 · Cited by 24 · cited 3×
“Specific physiological breakpoints have been assessed using NIRS technique in many muscle groups [73, 79, 91, 115, 145, 179] during ramp incremental exercise testing to better understand how distinct working muscles are differently affected by exercise intensity or training dose.”
BackgroundMethodResultKlusiewicz, A., Rębiś, K., Ozimek, M., & Czaplicki, A. (2021) · Biology of Sport · doi:10.5114/biolsport.2021.103571 · Cited by 24
Nybäck, L., Glännerud, C., Larsson, G., Weitzberg, E., Shannon, O. M., & McGawley, K. (2017) · Nitric Oxide · doi:10.1016/j.niox.2017.08.001 · Cited by 21
Inglis, E. C., Iannetta, D., Keir, D. A., & Murias, J. M. (2020) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2019-0046 · Cited by 21
van Hooff, M., Meijer, E. J., Scheltinga, M. R. M., Savelberg, H. H. C. M., & Schep, G. (2022) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12738 · Cited by 20
(2021) · International Journal of Exercise Science · doi:10.70252/hbra1900 · Cited by 19
Raleigh, C. J., Donne, B., & Fleming, N. (2018) · International Journal of Exercise Science · doi:10.70252/buct5185 · Cited by 19 · cited 3×
“Specific physiological breakpoints have been assessed using NIRS technique in many muscle groups [73, 79, 91, 115, 145, 179] during ramp incremental exercise testing to better understand how distinct working muscles are differently affected by exercise intensity or training dose.”
BackgroundMethodResultContreras-Briceño, F., Espinosa-Ramirez, M., Keim-Bagnara, V., Carreño-Román, M., Rodríguez-Villagra, R., Villegas-Belmar, F., Viscor, G., Gabrielli, L., Andía, M. E., Araneda, O. F., et al. (2022) · Life · doi:10.3390/life12030444 · Cited by 17
Rębiś, K., Sadowska, D., Starczewski, M., & Klusiewicz, A. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.809864 · Cited by 12
Quadriceps muscle oxygenation during a maximum stress test in middle-aged athletes
University of Murcia, U. I. F. R. I. A., Paredes-Ruiz, M.-J., Jodar-Reverte, M., University of Murcia, U. I. F. R. I. A., Ferrer-Lopez, V., University of Murcia, U. I. F. R. I. A., Martínez- González-Moro, I., & University of Murcia, U. I. F. R. I. A. (2020) · Montenegrin Journal of Sports Science and Medicine · doi:10.26773/mjssm.200908 · Cited by 8
Cited by
Arnold, J. I., Yogev, A., Nelson, H., van Hooff, M., & Koehle, M. S. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1449384 · Cited by 8
“Commercially available wearable NIRS devices have become more compact, powerful, and accessible in recent years with increasing adoption in sport science and clinical applications (Cornelis et al., 2021; Perrey et al., 2024).”
BackgroundInfluentialRębiś, K., Klusiewicz, A., Długołęcka, B., Różański, P., Kowieski, K., & Kowalski, T. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13175340 · Cited by 7
“As myoglobin oxygenation is expected to remain almost unchanged during exercise, any alteration in myoglobin and hemoglobin signals should mainly reflect changes in hemoglobin [4].”
BackgroundRębiś, K., Kowalski, T., Michalik, K., & Klusiewicz, A. (2024) · Sports · doi:10.3390/sports12120351 · Cited by 4
Metadata
- Authors
- Perrey, S., Quaresima, V., & Ferrari, M.
- Venue
- Sports Medicine
- Published
- 2024-02-12
- Volume
- 54
- Issue
- 4
- Pages
- 975-996
- ISSN
- 0112-1642 (ISSN-L)
- 1179-2035
- OpenAlex
- W4391754299
- Cited by
- 100
- References
- 38
- FWCI
- 18.77
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.