Cited by 25Pituitary Gland Disorders and TreatmentsAdrenal Hormones and DisordersClinical Laboratory Practices and Quality Control

Reference ranges of late-night salivary cortisol and cortisone measured by LC-MS/MS and accuracy for the diagnosis of cushing's syndrome

Ponzetto, F., Settanni, F., Parasiliti-Caprino, M., Rumbolo, F., Nonnato, A., Ricciardo, M., Amante, E., Priolo, G. +6 more·2020·Journal of Endocrinological Investigation

Abstract

Purpose International guidelines recommend salivary cortisol for the diagnosis of Cushing's syndrome. Despite mass spectrometry-based assays are considered the analytical gold-standard, there is still the need to define reference intervals and diagnostic accuracy of such methodology.Methods 100 healthy volunteers and 50 consecutive patients were enrolled to compare LC-MS/MS and electrochemiluminescence assay for the determination of late-night salivary cortisol and cortisone. Moreover, we aimed to determine reference intervals of salivary steroids in a population of healthy individuals and diagnostic accuracy in patients with suspected hypercortisolism and in a population including also healthy individuals.Results Method comparison highlighted a positive bias (51.8%) of immunoassay over LC-MS/MS. Reference intervals of salivary cortisol (0.17-0.97 µg/L), cortisone (0.84-4.85 µg/L) and ratio (0.08-0.30) were obtained. The most accurate thresholds of salivary cortisol for the diagnosis of hypercortisolism were 1.15 µg/L in the population with suspected hypercortisolism (AUC 1) and 1.30 µg/L in the population including also healthy individuals (AUC 1). Cut-off values of salivary cortisone (7.23 µg/L; Se 92.9%, Sp 97.2%, AUC 0.960 and Se 92.9%, Sp 99.1%, AUC 0.985 in suspected hypercortisolism and in overall population, respectively) and cortisol-to-cortisone ratio (0.20; Se 85.7%, Sp 80.6%, AUC 0.820 and Se 85.7%, Sp 85.5%, AUC 0.855 in suspected hypercortisolism and in overall population, respectively) were accurate and similar in both populations.Conclusion LC-MS/MS is the most accurate analytical platform for measuring salivary steroids. Obtained reference intervals are coherent with previously published data and diagnostic accuracy for diagnosis of overt hypercortisolism proved highly satisfactory.

Integrity signals

Registry

Crossref · 10.1007/s40618-020-01388-1

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ponzetto, F., Settanni, F., Parasiliti-Caprino, M., Rumbolo, F., Nonnato, A., Ricciardo, M., Amante, E., Priolo, G., Vitali, S., Anfossi, L., Arvat, E., Ghigo, E., Giordano, R., & Mengozzi, G.
Affiliations
  • University of Turin (IT)
  • Azienda Ospedaliera Citta' della Salute e della Scienza di Torino (IT)
Venue
Journal of Endocrinological Investigation
Published
2020-08-09
Volume
43
Issue
12
Pages
1797-1806
ISSN
  • 0391-4097 (ISSN-L)
  • 1720-8386
OpenAlex
W3048270531
Cited by
25
References
45
Citations by year
2026: 4 · 2025: 3 · 2024: 4 · 2023: 4 · 2022: 4 · 2021: 5 · 2020: 1
FWCI
2.65
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Endocrinological Investigation (publishedVersion)
  • PubMed (publishedVersion)
  • Institutional Research Information System University of Turin (University of Turin) (submittedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pituitary Gland Disorders and Treatments
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
Keywords
Cushing's syndrome, salivary cortisol, salivary cortisone, reference values, LC-MS/MS assay, electrochemiluminescence immunoassay, method comparison, diagnostic accuracy
MeSH terms
Adolescent, Adult, Chromatography, Liquid, Circadian Rhythm, Cortisone, Cushing Syndrome, Female, Humans, Hydrocortisone, Male, Middle Aged, Pituitary-Adrenal Function Tests, Predictive Value of Tests, Reference Values, Saliva, Reproducibility of Results, Case-Control Studies, Tandem Mass Spectrometry, Young Adult, Healthy Volunteers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review